The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
New desorption strategies for the mass spectrometric analysis of macromolecules
Abstract
We present two new desorption strategies for the mass spectrometric analysis of macromolecules. These desorption strategies are based on the molecular design and construction of two general classes of sample ‘probe’ surfaces. The first class of surfaces is designed to enhance the desorption of intact macromolecules presented alone (neat) to the surface; we call this surface‐enhanced neat desorption (SEND). The availability of probe surfaces derivatized with, or composed of, multiple types and defined numbers of energy‐absorbing molecules will facilitate investigations of energy transfer and desorption/ionization mechanisms. The second class of probe surfaces is designed to enhance the desorption of specific macromolecules captured directly from unfractionated biological fluids and extracts; we call this surface‐enhanced affinity capture (SEAC). Use of these new probe surfaces as chemically defined solid‐phase reaction centers will facilitate protein discovery through molecular recognition in situ , and also macromolecular structure analysis through the sequential chemical and/or enzymatic modification of the adsorbed analyte in situ . Specific examples of laser‐assisted SEND and SEAC time‐of‐flight mass spectrometry are presented to illustrate the potential for increased selectivity, analyte detection sensitivity, and mass measurement accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
α‐Cyano‐4‐hydroxycinnamic acid as a matrix for matrixassisted laser desorption mass spectromtry
Beavis, R. C., Chaudhary, T., & Chait, B. T. (1992) · Organic Mass Spectrometry · doi:10.1002/oms.1210270217 · Cited by 439
Hutchens, T. W., Henry, J. F., Yip, T., et al. (1991) · Pediatric Research · doi:10.1203/00006450-199103000-00005 · Cited by 130
Self-citationYip, T., & Hutchens, T. W. (1992) · FEBS Letters · doi:10.1016/0014-5793(92)81264-m · Cited by 78
Self-citationHutchens, T. W., Henry, J. F., & Yip, T. T. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.8.2994 · Cited by 61
Self-citationHutchens, T. W., Nelson, R. W., Allen, M. H., Li, C. M., & Yip, T. (1992) · Journal of Mass Spectrometry · doi:10.1002/bms.1200210307 · Cited by 48
Self-citation
Cited by
Zhang, Z., Bast, R. C., Yu, Y., Li, J., Sokoll, L. J., Rai, A. J., Rosenzweig, J. M., Cameron, B., Wang, Y. Y., Meng, X.-Y., et al. (2004) · Cancer Research · doi:10.1158/0008-5472.can-04-0746 · Cited by 934
Li, J., Zhang, Z., Rosenzweig, J., Wang, Y. Y., & Chan, D. W. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.8.1296 · Cited by 893
Recent advancements in surface-enhanced laser desorption/ionization-time of flight-mass spectrometry
Merchant, M., & Weinberger, S. R. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000401)21:6<1164::aid-elps1164>3.0.co;2-0 · Cited by 693
Vorm, O., Roepstorff, P., & Mann, M. (1994) · Analytical Chemistry · doi:10.1021/ac00091a044 · Cited by 687
Definitions of terms relating to mass spectrometry (IUPAC Recommendations 2013)
Murray, K. K., Boyd, R. K., Eberlin, M. N., Langley, G. J., Li, L., & Naito, Y. (2013) · Pure and Applied Chemistry · doi:10.1351/pac-rec-06-04-06 · Cited by 687
The SELDI-TOF MS Approach to Proteomics: Protein Profiling and Biomarker Identification
Issaq, H. J., Veenstra, T. D., Conrads, T. P., & Felschow, D. (2002) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.2002.6678 · Cited by 538
Detection technologies in proteome analysis
Patton, W. F. (2002) · Journal of Chromatography B · doi:10.1016/s1570-0232(02)00043-0 · Cited by 476
Contribution of Human α-Defensin 1, 2, and 3 to the Anti-HIV-1 Activity of CD8 Antiviral Factor
Zhang, L., Yu, W., He, T., Yu, J., Caffrey, R. E., Dalmasso, E. A., Fu, S., Pham, T., Mei, J., Ho, J. J., et al. (2002) · Science · doi:10.1126/science.1076185 · Cited by 468
RetractedCurrent developments in SELDI affinity technology
Tang, N., Tornatore, P., & Weinberger, S. R. (2004) · Mass Spectrometry Reviews · doi:10.1002/mas.10066 · Cited by 425
Vlahou, A., Schellhammer, P. F., Mendrinos, S., Patel, K., Kondylis, F. I., Gong, L., Nasim, S., & Wright Jr., G. L. (2001) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)64100-4 · Cited by 409
Mass Spectrometry, Review of the Basics: Electrospray, MALDI, and Commonly Used Mass Analyzers
El-Aneed, A., Cohen, A., & Banoub, J. (2009) · Applied Spectroscopy Reviews · doi:10.1080/05704920902717872 · Cited by 386
MALDI TOF MS profiling of bacteria at the strain level: A review
Sandrin, T. R., Goldstein, J. E., & Schumaker, S. (2013) · Mass Spectrometry Reviews · doi:10.1002/mas.21359 · Cited by 334
Coombes, K. R., Tsavachidis, S., Morris, J. S., Baggerly, K. A., Hung, M., & Kuerer, H. M. (2005) · PROTEOMICS · doi:10.1002/pmic.200401261 · Cited by 328
The role of cholesterol in the biosynthesis of β-amyloid.
Frears, E. R., Stephens, D. J., Walters, C. E., Davies, H., & Austen, B. M. (1999) · NeuroReport · doi:10.1097/00001756-199906030-00014 · Cited by 324
The Profile of Soluble Amyloid β Protein in Cultured Cell Media
Wang, R., Sweeney, D., Gandy, S. E., & Sisodia, S. S. (1996) · Journal of Biological Chemistry · doi:10.1074/jbc.271.50.31894 · Cited by 294
High-Affinity Capture of Proteins by Diamond Nanoparticles for Mass Spectrometric Analysis
Kong, X. L., Huang, L. C. L., Hsu, C.-M., Chen, W.-H., Han, C.-C., & Chang, H.-C. (2005) · Analytical Chemistry · doi:10.1021/ac048971a · Cited by 265
High-resolution serum proteomic features for ovarian cancer detection.
Conrads, T. P., Fusaro, V. A., Ross, S., Johann, D., Rajapakse, V, Hitt, B. A., Steinberg, S. M., Kohn, E. C., Fishman, D. A., Whitely, G., et al. (2004) · Endocrine-related cancer · doi:10.1677/erc.0.0110163 · Cited by 260
Milk allergens, their characteristics and their detection in food: A review
Monaci, L., Tregoat, V., van Hengel, A. J., & Anklam, E. (2006) · European Food Research and Technology · doi:10.1007/s00217-005-0178-8 · Cited by 259
Proteomics in Early Detection of Cancer
Srinivas, P. R., Srivastava, S., Hanash, S., & Wright, G. L. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.10.1901 · Cited by 254
Applications of MALDI Mass Spectrometry in Clinical Chemistry
Duncan, M. W., Nedelkov, D., Walsh, R., & Hattan, S. J. (2016) · Clinical Chemistry · doi:10.1373/clinchem.2015.239491 · Cited by 96
Jézéquel, P., Campion, L., Spyratos, F., Loussouarn, D., Campone, M., Guérin‐Charbonnel, C., Joalland, M., André, J., Descotes, F., Grenot, C., et al. (2012) · International Journal of Cancer · doi:10.1002/ijc.26397 · Cited by 85
Metadata
- Authors
- Hutchens, T. W., & Yip, T.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 1993-07
- Volume
- 7
- Issue
- 7
- Pages
- 576-580
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2117098825
- Cited by
- 621
- References
- 7
- FWCI
- 11.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.