Comparison of the LTQ‐Orbitrap Velos and the Q‐Exactive for proteomic analysis of 1–1000 ng RAW 264.7 cell lysate digests
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
RATIONALE: There is interest in extending bottom‐up proteomics to the smallest possible sample size. We investigated the performance of two modern mass spectrometers for the analysis of samples ranging from 1 ng to 1 µg of RAW 264.7 cell lysate digests. METHODS: An ultra‐performance liquid chromatography (UPLC) system coupled with either an LTQ‐Orbitrap Velos or a Q‐Exactive mass spectrometer was used for peptide separation and identification. RESULTS: For 1–1000 ng RAW 264.7 cell lysate digests, the Q‐Exactive generated 10–83% more protein groups and 11–109% more peptides than the LTQ‐Orbitrap Velos (higher‐energy collisional dissociation, HCD) with MASCOT database searching, due to its faster scan rate and higher resolution. In addition, HCD and collision‐induced dissociation (CID) modes of the LTQ‐Orbitrap Velos were compared. HCD produced higher peptide and protein group IDs than CID for 1–1000 ng RAW 264.7 cell lysate digests with MASCOT database searching. Database searching results from SEQUEST and MASCOT were also compared and comparable protein group IDs were obtained from the two search engines. CONCLUSIONS: The Q‐Exactive outperformed the LTQ‐Orbitrap Velos for shotgun proteomics analysis of 1 to 1000 ng RAW 264.7 cell lysate digests in terms of obtained peptide and protein group IDs. Copyright © 2012 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Michalski, A., Damoc, E., Hauschild, J.-P., Lange, O., Wieghaus, A., Makarov, A., Nagaraj, N., Cox, J., Mann, M., & Horning, S. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.011015 · Cited by 832 · cited 2×
“One report stated that the Q-Exactive produced about 28% more proteins and 13% more unique peptides than the LTQ-Orbitrap Velos (HCD) for tryptic digest of mammalian cell lysate [4].”
A dual pressure linear ion trap orbitrap instrument with very high sequencing speed
Olsen, J. V., Schwartz, J. C., Griep-Raming, J., Nielsen, M. L., Damoc, E., Denisov, E., Lange, O., Remes, P., Taylor, D., Splendore, M., et al. (2009) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900375-mcp200 · Cited by 464 · cited 3×
“Several reports made the comparison of CID and HCD for large-scale proteome [3, 11], phosphoproteome [12, 13] and peptidome [14, 15] analysis.”
Precision proteomics: The case for high resolution and high mass accuracy
Mann, M., & Kelleher, N. L. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0800788105 · Cited by 450 · cited 1×
“Shotgun proteomics has made great advances due to the improved sensitivity, resolution, and speed of recent generations of mass spectrometers [1, 2].”
Cited by
Kompauer, M., Heiles, S., & Spengler, B. (2017) · Nature Methods · doi:10.1038/nmeth.4071 · Cited by 600
Feist, P., & Hummon, A. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms16023537 · Cited by 288
Ultrasensitive and Fast Bottom‐up Analysis of Femtogram Amounts of Complex Proteome Digests
Sun, L., Zhu, G., Zhao, Y., Yan, X., Mou, S., & Dovichi, N. J. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201308139 · Cited by 212
Self-citationZhu, G., Sun, L., Yan, X., & Dovichi, N. J. (2013) · Analytical Chemistry · doi:10.1021/ac303750g · Cited by 103
Self-citation
Metadata
- Authors
- Sun, L., Zhu, G., & Dovichi, N. J.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2012-12-12
- Volume
- 27
- Issue
- 1
- Pages
- 157-162
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W1848204249
- Cited by
- 73
- References
- 3
- FWCI
- 2.93
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.