CoChat

Carbonate clumped isotope analyses with the long‐integration dual‐inlet (LIDI) workflow: scratching at the lower sample weight boundaries

Müller, Inigo A., Fernandez, Alvaro, Radke, Jens, van Dijk, Joep, Bowen, Devon, Schwieters, Johannes, Bernasconi, Stefano M. · 2017 · Rapid Communications in Mass Spectrometry
Cited by 131

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.

Abstract

Rationale: Clumped isotope analyses ( Δ 47 ) of carbonates by dual inlet (DI) mass spectrometry require long integration times to reach the necessary high precision due to the low abundance of the rare isotopologue 13 C 18 O 16 O. Traditional DI protocols reach this only with large amounts of sample and/or a large number of replicates as a large portion of the analyte gas is wasted. We tested an improved analytical workflow that significantly reduces the sample sizes and total analysis time per sample while preserving precision and accuracy. Methods: We implemented the LIDI (long‐integration dual‐inlet) protocol to measure carbonates in micro‐volume mode using a Kiel IV carbonate device coupled to a Thermo Scientific 253 Plus isotope ratio mass spectrometer without the new 10 13 ohm amplifier technology. The LIDI protocol includes a single measurement of the sample gas (600 s integration) followed by a single measurement of the working gas (WG) with the same integration time. Results: The Δ 47 measurements of four calcite standards over a period of 5 weeks demonstrate excellent long‐term stability with a standard deviation of ±0.021 to ±0.025 ‰ for the final values of the individual aliquots. The Δ 47 analyses of a coral, four foraminifera and a calcite precipitated in the laboratory demonstrate that 14 replicates of 90 to 120 μg are sufficient to achieve an external precision of ±0.007 ‰ (1SE) or of ±0.013 ‰ at the 95% confidence level. Conclusions: This study demonstrates that by using a Kiel IV–253 Plus system with LIDI it is possible to achieve the same analytical precision as conventional DI measurements with at least a factor of 40 less sample material. With the new 10 13 ohm resistor technology there is the potential to reduce the required sample material even more. This opens new avenues of research in paleoceanography, paleoclimatology, low‐temperature diagenesis and other currently sample size limited applications. Copyright © 2017 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rcm.7878

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 17

  1. 10.1038/nature13472 · DOI
  2. 10.1016/j.quascirev.2015.06.015 · DOI
  3. 10.1016/j.epsl.2016.01.001 · DOI
  4. 10.1016/j.tecto.2015.02.019 · DOI · Paper page
  5. 10.2110/jsr.2011.51 · DOI · Paper page
  6. Bergman S. C., 2013, Tracing paleofluid sources using clumped isotope thermometry of diagenetic cements along the MOAB fault, Utah, Am. J. Sci., 313, 490, 10.2475/05.2013.03 · DOI · Paper page
  7. 10.2110/jsr.2016.6 · DOI · Paper page
  8. 10.1111/sed.12337 · DOI
  9. 10.1002/rcm.6909 · DOI · Paper page
  10. 10.1016/j.chemgeo.2016.11.030 · DOI · Paper page
  11. 10.1002/rcm.6634 · DOI · Paper page
  12. 10.1002/rcm.6436 · DOI · Paper page
  13. 10.1038/nmeth.3091 · DOI · Paper page
  14. 10.1038/nmeth.2974 · DOI
  15. IUPAC, 1997, Compendium of Chemical Terminology
  16. 10.1016/j.gca.2016.01.023 · DOI · Paper page
  17. 10.1016/1044-0305(94)85054-2 · DOI

Cited by

See all 131

Metadata

Authors
Müller, I. A., Fernandez, A., Radke, J., van Dijk, J., Bowen, D., Schwieters, J., & Bernasconi, S. M.
Venue
Rapid Communications in Mass Spectrometry
Publisher
Wiley
Published
2017-05-21
Volume
31
Issue
12
Pages
1057-1066
ISSN
  • 0951-4198 (ISSN-L)
  • 1097-0231
OpenAlex
W2605884431
Cited by
131
References
27
FWCI
6.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.