Soft, Skin‐Interfaced Microfluidic Systems with Wireless, Battery‐Free Electronics for Digital, Real‐Time Tracking of Sweat Loss and Electrolyte Composition
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Sweat excretion is a dynamic physiological process that varies with body position, activity level, environmental factors, and health status. Conventional means for measuring the properties of sweat yield accurate results but their requirements for sampling and analytics do not allow for use in the field. Emerging wearable devices offer significant advantages over existing approaches, but each has significant drawbacks associated with bulk and weight, inability to quantify volumetric sweat rate and loss, robustness, and/or inadequate accuracy in biochemical analysis. This paper presents a thin, miniaturized, skin‐interfaced microfluidic technology that includes a reusable, battery‐free electronics module for measuring sweat conductivity and rate in real‐time using wireless power from and data communication to electronic devices with capabilities in near field communications (NFC), including most smartphones. The platform exploits ultrathin electrodes integrated within a collection of microchannels as interfaces to circuits that leverage NFC protocols. The resulting capabilities are complementary to those of previously reported colorimetric strategies. Systematic studies of these combined microfluidic/electronic systems, accurate correlations of measurements performed with them to those of laboratory standard instrumentation, and field tests on human subjects exercising and at rest establish the key operational features and their utility in sweat analytics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
Self-citationA Wearable Electrochemical Platform for Noninvasive Simultaneous Monitoring of Ca2+ and pH
Nyein, H. Y. Y., Gao, W., Shahpar, Z., Emaminejad, S., Challa, S., Chen, K., Fahad, H. M., Tai, L.-C., Ota, H., Davis, R. W., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b04005 · Cited by 669
Taylor, N. A., & Machado-Moreira, C. A. (2013) · Extreme Physiology & Medicine · doi:10.1186/2046-7648-2-4 · Cited by 490
Skin-interfaced systems for sweat collection and analytics
Choi, J., Ghaffari, R., Baker, L. B., & Rogers, J. A. (2018) · Science Advances · doi:10.1126/sciadv.aar3921 · Cited by 433
Self-citationBaker, L. B. (2017) · Sports Medicine · doi:10.1007/s40279-017-0691-5 · Cited by 403
Role of Dehydration in Heat Stress-Induced Variations in Mental Performance
Gopinathan, P. M., Pichan, G., & Sharma, V. M. (1988) · Archives of Environmental Health: An International Journal · doi:10.1080/00039896.1988.9934367 · Cited by 388
Body mapping of sweating patterns in male athletes in mild exercise-induced hyperthermia
Smith, C. J., & Havenith, G. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1744-8 · Cited by 375
Non‐invasive Analyte Access and Sensing through Eccrine Sweat: Challenges and Outlook circa 2016
Heikenfeld, J. (2016) · Electroanalysis · doi:10.1002/elan.201600018 · Cited by 294
Differences in composition of sweat induced by thermal exposure and by running exercise
Fukumoto, T., Tanaka, T., Fujioka, H., Yoshihara, S., Ochi, T., & Kuroiwa, A. (1988) · Clinical Cardiology · doi:10.1002/clc.4960111010 · Cited by 41
Cited by
Hong, Y. J., Jeong, H., Cho, K. W., Lu, N., & Kim, D. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808247 · Cited by 559
Wen, F., Sun, Z., He, T., Shi, Q., Zhu, M., Zhang, Z., Li, L., Zhang, T., & Lee, C. (2020) · Advanced Science · doi:10.1002/advs.202000261 · Cited by 478
Yang, Y., Guo, X., Zhu, M., Sun, Z., Zhang, Z., He, T., & Lee, C. (2023) · Advanced Energy Materials · doi:10.1002/aenm.202203040 · Cited by 337
Wireless battery-free body sensor networks using near-field-enabled clothing
Lin, R., Kim, H.-J., Achavananthadith, S., Kurt, S. A., Tan, S. C. C., Yao, H., Tee, B. C. K., Lee, J. K. W., & Ho, J. S. (2020) · Nature Communications · doi:10.1038/s41467-020-14311-2 · Cited by 331
Flexible and Stretchable Antennas for Biointegrated Electronics
Xie, Z., Avila, R., Huang, Y., & Rogers, J. A. (2020) · Advanced Materials · doi:10.1002/adma.201902767 · Cited by 262
Self-citation
Metadata
- Authors
- Kim, S. B., Lee, K., Raj, M. S., Lee, B., Reeder, J. T., Koo, J., Hourlier‐Fargette, A., Bandodkar, A. J., Won, S. M., Sekine, Y., Choi, J., Zhang, Y., Yoon, J., Kim, B. H., Yun, Y., Lee, S., Shin, J., Kim, J., Ghaffari, R., & Rogers, J. A.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2018-10-09
- Volume
- 14
- Issue
- 45
- Pages
- e1802876-e1802876
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2897486950
- Cited by
- 115
- References
- 10
- FWCI
- 5.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Soft, Skin‐Interfaced Microfluidic Systems with Wireless, Battery‐Free Electronics for Digital, Real‐Time Tracking of Sweat Loss and Electrolyte Composition. https://app.cochat.ai/papers/10.1002/smll.201802876
- The paper
- Kim, S. B., Lee, K., Raj, M. S., Lee, B., Reeder, J. T., Koo, J., Hourlier‐Fargette, A., Bandodkar, A. J., Won, S. M., Sekine, Y., Choi, J., Zhang, Y., Yoon, J., Kim, B. H., Yun, Y., Lee, S., Shin, J., Kim, J., Ghaffari, R., & Rogers, J. A. (2018). Soft, Skin‐Interfaced Microfluidic Systems with Wireless, Battery‐Free Electronics for Digital, Real‐Time Tracking of Sweat Loss and Electrolyte Composition. Small. https://doi.org/10.1002/smll.201802876
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.