Polydopamine‐Decorated PLCL Conduit to Induce Synergetic Effect of Electrical Stimulation and Topological Morphology for Peripheral Nerve Regeneration
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Due to the limited self‐repairing capacity after peripheral nerve injuries (PNI), artificial nerve conduits are widely applied to facilitate neural regeneration. Exogenous electrical stimulation (ES) that is carried out by the conductive conduit regulates the biological behavior of Schwann cells (SCs). Meanwhile, a longitudinal surface structure counts to guide axonal growth to accelerate the end‐to‐end connection. Currently, there are no conduits equipped with both electrical conduction and axon‐guiding surface structure. Herein, a biodegradable, conductive poly(l‐lactide‐co‐caprolactone)/graphene (PLCL/GN) composite conduit is designed. The conduit with 20.96 ± 1.26 MPa tensile strength has a micropatterned surface of 20 µm groove fabricated by microimprint technology and self‐assembled polydopamine (PDA). In vitro evaluation shows that the conduits with ES effectively stimulate the directional cell migration, adhesion, and elongation, and enhance neuronal expression of SCs. The rat sciatic nerve crush model demonstrates that the conductive micropatterned conduit with ES promotes the growth of myelin sheath, faster nerve regeneration, and 20‐fold functional recovery in vivo. These discoveries prove that the PLCL(G)/PDA/GN composite conduit is a promising tool for PNI treatment by providing the functional integration of physical guidance, biomimetic biological regulation, and bioelectrical stimulation, which inspires a novel therapeutic approach for nerve regeneration in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Liu, Y., Ai, K., & Lu, L. (2014) · Chemical Reviews · doi:10.1021/cr400407a · Cited by 4,794
Self-citationNeural tissue engineering options for peripheral nerve regeneration
Gu, X., Ding, F., & Williams, D. F. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.04.064 · Cited by 630
Myelin plasticity and nervous system function
Monje, M. (2018) · Annual Review of Neuroscience · doi:10.1146/annurev-neuro-080317-061853 · Cited by 274
Wu, S., Dong, T., Li, Y., Sun, M., Qi, Y., Liu, J., Kuss, M. A., Chen, S., & Duan, B. (2022) · Applied Materials Today · doi:10.1016/j.apmt.2022.101473 · Cited by 250
Self-citation
Cited by
Polydopamine Applications in Biomedicine and Environmental Science
Omidian, H., & Wilson, R. L. (2024) · Materials · doi:10.3390/ma17163916 · Cited by 47
Application of PLCL as a biodegradable polymer in biomedical engineering
Zhao, Y., & Liu, H. (2026) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-026-07016-3 · Cited by 7
Metadata
- Authors
- Lu, S., Chen, W., Wang, J., Guo, Z., Xiao, L., Wei, L., Yu, J., Yuan, Y., Chen, W., Bian, M., Huang, L., Liu, Y., Zhang, J., Li, Y., & Jiang, L.
- Venue
- Small Methods
- Publisher
- Wiley
- Published
- 2023-01-03
- Volume
- 7
- Issue
- 2
- Pages
- e2200883-e2200883
- ISSN
- 2366-9608 (ISSN-L)
- OpenAlex
- W4313487976
- Cited by
- 82
- References
- 4
- FWCI
- 8.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Polydopamine‐Decorated PLCL Conduit to Induce Synergetic Effect of Electrical Stimulation and Topological Morphology for Peripheral Nerve Regeneration. https://app.cochat.ai/papers/10.1002/smtd.202200883
- The paper
- Lu, S., Chen, W., Wang, J., Guo, Z., Xiao, L., Wei, L., Yu, J., Yuan, Y., Chen, W., Bian, M., Huang, L., Liu, Y., Zhang, J., Li, Y., & Jiang, L. (2023). Polydopamine‐Decorated PLCL Conduit to Induce Synergetic Effect of Electrical Stimulation and Topological Morphology for Peripheral Nerve Regeneration. Small Methods. https://doi.org/10.1002/smtd.202200883
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.