CoChat

The impact of choice of reference charts and equations on the assessment of fetal biometry

Open access
Salomon, L. J., Bernard, J. P., Duyme, M., Buvat, I., Ville, Y. · 2005 · Ultrasound in Obstetrics & Gynecology
Cited by 111

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Objectives: The assessment of fetal biometry is usually based on the comparison of measured values with predicted values derived from reference charts or equations in a normal population. This study was undertaken to assess the impact of the choice of reference charts and to develop a Z‐score‐based tool that could help sonographers to choose the reference charts that best fit their practice. Methods: Fetal biparietal diameter, head circumference, abdominal circumference and femur diaphysis length measurements were made at 20–24 and 30–34 weeks' gestation by four experienced sonographers. All measurements were transformed into Z‐scores calculated according to three prediction equations (Snijders and Nicolaides, 1994; Chitty et al., 1994 and Kurmanavicius et al., 1999). Distributions of Z‐scores were compared to the expected standard normal distribution based on mean, SD and Kolmogorov–Smirnov test. Simulations were made to assess sensitivity (Se), specificity (Sp) and Youden's index (Se + Sp − 1) of each reference equation, reflecting their ability to identify fetuses with abnormal biometry in our population. The reference that best fitted our practice was determined based on these results. Results: The Z‐scores of all biometric parameters were significantly different (P < 0.001) when using any of the three reference equations, and none of the Z‐score distributions could be considered similar to the standard normal distribution. The number of measurements that would be considered as abnormal according to these references ranged from 2.6% to 23.6%. Se and Sp ranged from 39.59% to 67.12% and 90.14% to 99.69%, respectively. Conclusion: Assessment of fetal biometry is largely dependent on the choice of reference charts. We suggest that the choice of reference charts for fetal biometry could be controlled using Z‐scores in each institution and that this could be the first step towards any quality assessment policy. The method we describe for the choice of the most appropriate fetal biometry reference chart might be used for all size charts. Copyright © 2005 ISUOG. Published by John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.1901

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Salomon, L. J., Bernard, J. P., Duyme, M., Buvat, I., & Ville, Y.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2005-05-23
Volume
25
Issue
6
Pages
559-565
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2020572841
Cited by
111
References
1
FWCI
4.23
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.