CoChat

Feasibility and reproducibility of an image‐scoring method for quality control of fetal biometry in the second trimester

Open access
Salomon, L. J., Bernard, J. P., Duyme, M., Doris, B., Mas, N., Ville, Y. · 2006 · Ultrasound in Obstetrics & Gynecology
Cited by 146

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Objectives: The need for training programs and certification processes in fetal ultrasound has become obvious. The purpose of this study was to evaluate the feasibility of a score‐based quality control system for fetal biometry in the second trimester. Methods: Standard measurements of biparietal diameter and head circumference, abdominal circumference, and femur length at 20–24 weeks had been made by four operators using the same ultrasound machine. Twenty‐five of each of the cephalic, abdominal and femoral images with the calipers in place were selected arbitrarily from each operator's ultrasound database and anonymized. These 300 images were analyzed by three experienced reviewers blinded to the operator's identity. Each image was first evaluated subjectively and then scored according to six criteria for abdominal and cephalic measurements and four criteria for femur length making a six‐point score for abdominal and cephalic biometry and a four‐point score for femur length. For subjective evaluation, inter‐reviewer differences were analyzed using percentage agreement and adjusted kappa. For objective evaluation, a difference in scoring of one point or less among reviewers was considered good agreement. Intrareviewer variability was assessed using 40 images of each type of examination selected arbitrarily. Results: The distribution of scores was similar between reviewers. One operator obtained significantly lower scores whereas the other three had good and comparable results. There was no statistical difference in the mean score attributed by each reviewer and agreement was good in 84–90% of the cases. Intrareviewer agreement was good in 90–100% of the cases, with similar scores for each reviewer. Conclusion: A quality control policy based on image scoring is feasible and allows for fair to good inter‐ and intrareviewer reproducibility. The potential contribution of this approach to assess the quality of routine ultrasound examinations should be tested on a larger scale. Copyright © 2005 ISUOG. Published by John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.2665

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 146

Metadata

Authors
Salomon, L. J., Bernard, J. P., Duyme, M., Doris, B., Mas, N., & Ville, Y.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2005-12-22
Volume
27
Issue
1
Pages
34-40
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2132061786
Cited by
146
References
3
FWCI
3.70
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.