A mixture model of nuchal translucency thickness in screening for chromosomal defects

Open access
Wright, D., Kagan, K. O., Molina, F. S., Gazzoni, A., Nicolaides, K. H.·2008·Ultrasound in Obstetrics & Gynecology

Abstract

Objective: Fetal nuchal translucency (NT) thickness increases with crown–rump length (CRL). In screening for chromosomal defects patient‐specific risks are derived by multiplying the a priori maternal age‐related risk by a likelihood ratio, determined from the deviation of the measured NT from the expected median. To quantify this deviation the measured NT is either subtracted (delta NT) or divided by the expected median (multiple of the median method, MoM). This study examines the validity of these methods. Methods: NT was prospectively measured at 11 + 0 to 13 + 6 weeks in screening for chromosomal defects. The distribution of NT in euploid and chromosomally abnormal fetuses was examined. Results: There were 37 078 normal pregnancies and 264 with trisomy 21, 81 with trisomy 18, 38 with trisomy 13 and 27 with Turner syndrome. We found that firstly, contrary to the assumption underlying the delta NT method, the distribution of delta NT changes with CRL and secondly, contrary to the assumption underlying the MoM method the distribution of NT was not Gaussian. Fetal NT followed two distributions, one that was dependent on CRL and one that was independent of CRL. The distribution in which NT increases with CRL was observed in about 95% of euploid fetuses, 5% with trisomy 21, 30% with trisomy 18, 15% with trisomy 13 and 10% with Turner syndrome. The median CRL‐independent NT was 2.0 mm for the euploid group and 3.4, 5.5, 4.0 and 7.8 mm for trisomies 21, 18, 13 and Turner syndrome, respectively. Conclusions: The NT thickness in chromosomally normal and abnormal fetuses follows a mixture of a gestation‐dependent and gestation‐independent distribution. Copyright © 2008 ISUOG. Published by John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.5299

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

See all 257

Metadata

Authors
Wright, D., Kagan, K. O., Molina, F. S., Gazzoni, A., & Nicolaides, K. H.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2008-03-28
Volume
31
Issue
4
Pages
376-383
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2122622674
Cited by
257
References
21
FWCI
20.84
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A mixture model of nuchal translucency thickness in screening for chromosomal defects. https://app.cochat.ai/papers/10.1002/uog.5299
The paper
Wright, D., Kagan, K. O., Molina, F. S., Gazzoni, A., & Nicolaides, K. H. (2008). A mixture model of nuchal translucency thickness in screening for chromosomal defects. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.5299

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.