Cited by 27Prenatal Screening and DiagnosticsUltrasound in Clinical ApplicationsUltrasound Imaging and Elastography

Narrowed beam width in newer ultrasound machines shortens measurements in the lateral direction: fetal measurement charts may be obsolete

Økland, I., Bjåstad, T. G., Johansen, T. F., Gjessing, H. K., Grøttum, P., Eik‐Nes, S. H.·2011·Ultrasound in Obstetrics & Gynecology

Abstract

Objectives: Fetal ultrasound measurements are made in axial, lateral and oblique directions. Lateral resolution is influenced by the beam width of the ultrasound system. To improve lateral resolution and image quality, the beam width has been made narrower; consequently, measurements in the lateral direction are affected and apparently made shorter, approaching the true length. The aims of this study were to explore our database to reveal time‐dependent shortening of ultrasound measurements made in the lateral direction, and to assess the extent of beam‐width changes by comparing beam‐width measurements made on old and new ultrasound machines. Methods: A total of 41 941 femur length measurements, collected during the time‐period 1987–2005, were analyzed, with time as a covariate. Using three ultrasound machines from the 1990s and three newer machines from 2007, we performed 25 series of blinded beam‐width measurements on a tissue‐mimicking phantom, measuring at depths of 3–8 cm with a 5‐MHz transducer. Results: Regression analysis showed time to be a significant covariate. At the same gestational age, femur length measurement was 1.15 (95% CI, 1.08–1.23) mm shorter in the time‐period 1999–2005 than in the time‐period 1987–1992. Overall, the beam width was 1.08 (95% CI, 0.50–1.65) mm narrower with the new machines than with the old machines. Conclusions: Technical improvements in modern ultrasound machines that have reduced the beam width affect fetal measurements in the lateral direction. This has clinical implications and new measurement charts are needed. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.

Integrity signals

Registry

Crossref · 10.1002/uog.8954

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Økland, I., Bjåstad, T. G., Johansen, T. F., Gjessing, H. K., Grøttum, P., & Eik‐Nes, S. H.
Affiliations
  • Stavanger University Hospital (NO)
  • Norwegian University of Science and Technology (NO)
  • Norwegian Institute of Public Health (NO)
  • University of Oslo (NO)
Corresponding author
Økland, I.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2011-06-28
Volume
38
Issue
1
Pages
82-87
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2030447998
Cited by
27
References
26
Citations by year
2023: 2 · 2022: 2 · 2021: 2 · 2020: 4 · 2019: 1 · 2018: 4 · 2017: 1 · 2016: 5 · 2015: 2 · 2013: 1 · 2012: 2
FWCI
1.17
Type
journal article
Language
en
Open access
closed
Locations
  • Ultrasound in Obstetrics and Gynecology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Prenatal Screening and Diagnostics
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Ultrasound in Clinical Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
Keywords
lateral resolution, fetal biometry, femur length, tissue phantoms, gestational age
MeSH terms
Analysis of Variance, Biometry, Female, Femur, Humans, Pregnancy, Pregnancy Trimester, Second, Reference Values, Regression Analysis, Databases, Factual, Ultrasonography, Prenatal, Phantoms, Imaging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review