The DOI matches its Crossref record; 45 of the 46 references it cites were found in a registry or an index.
Optical Coherence Tomography (OCT): Principle and Technical Realization
Open accessAbstract
Optical coherence tomography (OCT) is a non-invasive technique for cross-sectional tissue imaging. It typically uses light in the near-infrared spectral range which has a penetration depth of several hundred microns in tissue. The backscattered light is measured with an interferometric set-up to reconstruct the depth profile of the sample at the selected location. A scanning OCT beam allows for acquisition of cross-sectional images of the tissue structure. Different technical methods are introduced and compared regarding their properties like sensitivity, imaging speed and penetration depth. Regardless of the technical realization, axial resolution and imaging range of an OCT system are determined by light source and detector characteristics. Combining retinal OCT with a confocal scanning laser ophthalmoscope allows for motion tracking during acquisition and to examine the exact same position at any time again. Segmentation of features is the basis for automatic depth measurements and standardized measurements to be compared with normative databases. New trends show the ability of functional OCT to image flow, polarizing properties of tissue and even mechanical properties like elasticity. Recent approaches to improve the resolution and the acquisition speed show the ongoing research interest in OCT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“OCT imaging at depth is negatively affected by absorption with light absorption and attenuation in upper tissue layers leading to less light reaching lower layers.”
From Effect of skin color on optical properties and the implications for medical optical technologies: a review (2024) · cites this paper as [85]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K. W., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 14,001
Optical coherence tomography - principles and applications
FERCHER, A. F., Drexler, W., Hitzenberger, C. K. F., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,871
Performance of fourier domain vs time domain optical coherence tomography
Leitgeb, R. A., Hitzenberger, C. K. F., & FERCHER, A. F. (2003) · Optics Express · doi:10.1364/oe.11.000889 · Cited by 1,859
Sensitivity advantage of swept source and Fourier domain optical coherence tomography
Choma, M. A., Šarunic, M. V., Yang, C., & Izatt, J. A. (2003) · Optics Express · doi:10.1364/oe.11.002183 · Cited by 1,789
de Boer, J. F., Cense, B., Park, B. H., Pierce, M. C., Tearney, G. J., & Bouma, B. E. (2003) · Optics Letters · doi:10.1364/ol.28.002067 · Cited by 1,245
Measurement of intraocular distances by backscattering spectral interferometry
FERCHER, A. F., Hitzenberger, C. K. F., Kamp, G., & El-Zaiat, S. Y. (1995) · Optics Communications · doi:10.1016/0030-4018(95)00119-s · Cited by 1,208
von Braunmühl, T. (2015) · Der Hautarzt · doi:10.1007/s00105-015-3607-z · Cited by 1,036
Huber, R. A., Wojtkowski, M., & Fujimoto, J. G. (2006) · Optics Express · doi:10.1364/oe.14.003225 · Cited by 982
Refractive indices of water and ice in the 065- to 25-μm spectral range
Kou, L., Labrie, D., & Chýlek, P. (1993) · Applied Optics · doi:10.1364/ao.32.003531 · Cited by 804
Optical coherence tomography using a frequency-tunable optical source
Chinn, S. R., Swanson, E. A., & Fujimoto, J. G. (1997) · Optics Letters · doi:10.1364/ol.22.000340 · Cited by 666
Flagged first, then by citations
1 of the 46 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Items 201–300 of 449
MAPI-Net: A context and location fusion network for multi-lesion segmentation in intravascular OCT
Su, W., Huang, Z., Wang, Z., Li, Q., & Li, J. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106559 · Cited by 4
Wheeler, T. W., Hunter, K., Garcia, P., Li, H. H., Thomson, A. C., Hunter, A. A., & Mehanian, C. (2024) · PLOS Digital Health · doi:10.1371/journal.pdig.0000411 · Cited by 4
All-optical platform for ultrasound transmission matrix measurements
Moisseev, R., & Rosenthal, A. (2024) · APL Photonics · doi:10.1063/5.0199554 · Cited by 4
Akbari, F., Zibaii, M. I., Chavoshinezhad, S., Layeghi, A., Dargahi, L., & Frazão, O. (2024) · Optical Fiber Technology · doi:10.1016/j.yofte.2024.104024 · Cited by 4
Vision Transformers for Retinal Disease Classification using Optical Coherence Tomography Images
Kakumani, A. K., Tanuja, K., & Yetukuri, J. S. (2025) · International Conference on Computer, Electrical & Communication Engineering (ICCECE) · doi:10.1109/iccece61355.2025.10941428 · Cited by 4
Muangsopa, P., Yong, G. Y., Thathong, Y., Kampaengsri, S., Chansaenpak, K., Saetiew, J., Khrootkaew, T., Jantasin, A., Meemon, P., Sukwattanasinitt, M., et al. (2025) · ACS Applied Bio Materials · doi:10.1021/acsabm.5c00878 · Cited by 4
Athira Nair, K., Siva Kumar, B., Reddy, S. G., & Kugabalasooriar, S. (2026) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2025.2612631 · Cited by 5
Near-infrared metalens for high-resolution and deep focus optical coherence tomography
Haerinia, M., Zheng, B., Hutchins, A., Tang, H., Li, H., Dong, Y., Guo, W., & Zhang, H. (2022) · AIP Advances · doi:10.1063/5.0131170 · Cited by 4
Imaging of intracranial aneurysms in animals: a systematic review of modalities
Cayron, A. F., Morel, S., Allémann, É., Bijlenga, P., & Kwak, B. R. (2023) · Neurosurgical Review · doi:10.1007/s10143-023-01953-1 · Cited by 4
An Assessment of Contemporary Methods and Data-Enabled Approaches for Early Cataract Detection
Muchibwa, C., Eldaw, M. H. S., Mu, M., & Agyeman, M. O. (2023) · F1000Research · doi:10.12688/f1000research.138294.1 · Cited by 6
Liao, J., Zhang, T., Shepherd, S. D., Macluskey, M., Li, C., & Huang, Z. (2024) · Biomedical Optics Express · doi:10.1364/boe.545377 · Cited by 4
Sturm, B., Zang, A.-L., Stingl, J., Hasseli-Fräbel, R., Fanouriakis, A., Schwarting, A., Geber, C., Weinmann‐Menke, J., Alhaddad, M., & Triantafyllias, K. (2025) · Frontiers in Immunology · doi:10.3389/fimmu.2025.1543157 · Cited by 5
Multimodal Imaging in Stem Cell Therapy for Retinal Disease
Zheng, M., & Paulus, Y. M. (2025) · Photonics · doi:10.3390/photonics12050413 · Cited by 4
Identification of organs inside hard tick body using spectral-domain optical coherence tomography
Lee, J., Ryu, J., Han, S., Ravichandran, N. K., Seong, D., Lee, J., Wijesinghe, R. E., Kim, P., Lee, S., Jung, H., et al. (2021) · Infrared Physics & Technology · doi:10.1016/j.infrared.2020.103611 · Cited by 4
Patil, M. A., & Kompella, U. B. (2021) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2021.120887 · Cited by 4
Multi-axis modulated compact fiber-based Fabry–Perot interferometric probe
Shabahang, F., & Smith, S. T. (2022) · Applied Optics · doi:10.1364/ao.453951 · Cited by 4
Elmers, J., Colzato, L. S., Ziemssen, F., Ziemssen, T., & Beste, C. (2024) · Ageing Research Reviews · doi:10.1016/j.arr.2024.102280 · Cited by 4
Ultrashort chirp pulses for Kundu–Eckhaus equation in nonlinear optics
El‐Shiekh, R. M., & Gaballah, M. (2024) · Optical and Quantum Electronics · doi:10.1007/s11082-024-07222-9 · Cited by 4
Żmijewska, M. A., Wawrzyniak, Z. M., Janiszewski, M., & Zaleska-Żmijewska, A. (2024) · Diagnostics · doi:10.3390/diagnostics14070710 · Cited by 3
A Novel Small Form-Factor Handheld Optical Coherence Tomography Probe for Oral Soft Tissue Imaging
Kushwaha, A. K., Ji, M., Sethi, S., Jamieson, L., McLaughlin, R. A., & Li, J. (2024) · Micromachines · doi:10.3390/mi15060742 · Cited by 3
Automatic Detection and Characterization of Human Veins Using Infra-Red Image Processing
Ndoumbe, J., Akoa, B. E., Talotsing, G. P., Kounga, F. F., Kaïssassou, S., & Njo, B. C. (2024) · Journal of Computer and Communications · doi:10.4236/jcc.2024.129009 · Cited by 3
Keim, A., Pandit, P. P., Sotelo, L. D., & McClain, M. S. (2025) · Virtual and Physical Prototyping · doi:10.1080/17452759.2025.2569544 · Cited by 3
Haga, K., Kamimura, Y., Yamazaki, M., Funayama, A., Saito, Y., Kida, M., Tanuma, J., & Izumi, K. (2025) · Scientific Reports · doi:10.1038/s41598-025-28471-y · Cited by 3
A Framework for Healthcare from the Eye
Weinreb, R. N., Keane, P. A., Cooley, A., CHAGLASIAN, M. A., Lee, A., McConnell, M. V., Leng, T., Hashemi, Z., Ferrara, D., & Rhew, D. C. (2026) · Ophthalmology · doi:10.1016/j.ophtha.2026.01.018 · Cited by 3
Advances in the application of optical coherence elastography in ophthalmology
Wang, L., Zhu, Y., Huang, H., Huang, L., Zhang, Z., Luo, N., Álvarez-Arenas, T. E. G., Shi, J. S. J., & He, X. (2026) · Journal of Innovative Optical Health Sciences · doi:10.1142/s179354582630003x · Cited by 3
Retinal Thinning in People With Well-Controlled HIV Infection
Geannopoulos, K., McMahan, C. C., Maldonado, R. S., Abbott, A. B., Knickelbein, J. E., Agrón, E., Wu, T., Snow, J., Nair, G., Horne, E. F., et al. (2022) · JAIDS Journal of Acquired Immune Deficiency Syndromes · doi:10.1097/qai.0000000000003048 · Cited by 3
An innovative multi-modal retinal imaging system for in vivo retinal detection in small animals
Tang, Z., Zhao, T., Ji, R., Zhang, K., Yin, Q., Zhang, T., Zhang, H., Dong, T., Zhang, P., & Zhang, J. (2023) · Frontiers in Ophthalmology · doi:10.3389/fopht.2023.1251328 · Cited by 3
Varshney, A. S., & Bhattacharjee, D. (2025) · IP International Journal of Ocular Oncology and Oculoplasty · doi:10.18231/j.ijooo.2025.005 · Cited by 3
Memmi, B., Wu, Q., Borderie, V. M., & Allain, J. (2026) · Journal of Refractive Surgery · doi:10.3928/1081597x-20251202-03 · Cited by 3
Mackenbrock, L. H. B., Weindler, J. N., Łabuz, G., Baur, I. D., Auffarth, G. U., & Khoramnia, R. (2023) · Klinische Monatsblätter für Augenheilkunde · doi:10.1055/a-2120-7415 · Cited by 3
Yojana, K., & Rani, L. T. (2023) · ACTA IMEKO · doi:10.21014/actaimeko.v12i3.1345 · Cited by 3
Scuderi, L., Fragiotta, S., Ciancimino, C., Mafrici, M., Mazzola, M., Varano, M., Rossi, T., & Parravano, M. (2024) · Photonics · doi:10.3390/photonics11100991 · Cited by 3
Advances in Corneal Diagnostics Using Machine Learning
Al-Sharify, N. T., Yussof, S., Ghaeb, N. H., Al-Sharify, Z. T., Nser, H. Y., Ahmed, S. M., See, O. H., & Weng, L. Y. (2024) · Bioengineering · doi:10.3390/bioengineering11121198 · Cited by 3
Qadri, J., Jothi, J. A. A., & Jain, M. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.108319 · Cited by 3
Fernandes, J. R., dos Santos, L. C. F., & Lamers, M. L. (2022) · Photodiagnosis and Photodynamic Therapy · doi:10.1016/j.pdpdt.2022.103238 · Cited by 3
Optical coherence tomography in multiple sclerosis
Krajnc, N., & Bsteh, G. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-95739-7.00008-3 · Cited by 3
Suzuki, T., Ueno, T., Oishi, N., & Fukuyama, H. (2020) · Scientific Reports · doi:10.1038/s41598-020-76468-6 · Cited by 2
Multicriteria assessment of optical coherence tomography using non‐raster trajectories
Osinde, N. O., & Andreff, N. (2024) · Journal of Microscopy · doi:10.1111/jmi.13383 · Cited by 2
Xing, J., Jiang, S., Xu, J., Guo, D., Zhang, J., Li, P., Zhang, H., Xue, L., Tuchin, V. V., Gu, X., et al. (2025) · Neurocomputing · doi:10.1016/j.neucom.2025.130113 · Cited by 2
Aghdam, K. A., Katiraee, A., Chaibakhsh, S., Sanjari, M. S., Miraftabi, A., Nadjafi, F., Sadeghi, A., Hosseinabadi, V. Z., & Zand, A. (2025) · BMC Ophthalmology · doi:10.1186/s12886-025-04205-6 · Cited by 2
Gu, J., Liao, J., Zhang, T., Zhang, Y., Shepherd, S. D., Macluskey, M., Huang, Z., & Li, C. (2025) · Journal of Biophotonics · doi:10.1002/jbio.202500252 · Cited by 2
Dong, L., Gao, W., Niu, L., Deng, Z., Gong, Z., Li, H., Fang, L.-J., Shao, L., Zhang, R., Zhou, W., et al. (2025) · British Journal of Ophthalmology · doi:10.1136/bjo-2025-327189 · Cited by 2
From Molecules to Modules: Advanced Characterization of Membrane Systems
Zhu, Y., Booth, A. J., Eatman, J. G., Kim, M. A., Liu, Y., Sarkar, B., Sengupta, B., Yue, X., Amanchukwu, C. V., Darling, S. B., et al. (2025) · Advanced Materials · doi:10.1002/adma.202513056 · Cited by 2
Lens opacity as a predictor of retinal vasculature change following cataract surgery
Mackenbrock, L. H. B., Xu, A. T. L., Łabuz, G., Augustin, V. A., Yildirim, T. M., Auffarth, G. U., & Khoramnia, R. (2025) · Scientific Reports · doi:10.1038/s41598-025-19037-z · Cited by 2
Optical strategies for in vivo retinal ganglion cell imaging
Chen, J., Fang, R., Liu, X., & Zhang, H. F. (2025) · Med-X · doi:10.1007/s44258-025-00066-2 · Cited by 2
Lim, K. S. A., Tng, W. X. A., Theng, W. D. B., Lee, B. T. K., Chin, C. F., Li, K. Z., & Moss, H. E. (2026) · Frontiers in Ophthalmology · doi:10.3389/fopht.2025.1691582 · Cited by 2
Quantifying Dehydration Effects of Porcine Vocal Fold Attenuation With Optical Coherence Tomography
Wischhoff, O. P., Kuang, M., Prosser, B. D., Holm, J. R., & Jiang, J. (2026) · The Laryngoscope · doi:10.1002/lary.70529 · Cited by 2
Artificial intelligence applications in OCT and OCTA for diabetic retinopathy: A systematic review
Tavakoli, M., & Ramezanzadeh, E. (2026) · Experimental Eye Research · doi:10.1016/j.exer.2026.111046 · Cited by 2
Extended measuring depth dual-wavelength Fourier domain optical coherence tomography
Al‐Mohamedi, H., Kelly‐Pérez, I., Oltrup, T., Cayless, A., & Bende, T. (2021) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2020-0350 · Cited by 2
Unsupervised Region-Based Denoising for Optical Coherence Tomography Framework
Ahmed, H., Zhang, Q., Donnan, R. S., & Alomainy, A. (2022) · International Conference on Computational Intelligence and Applications (ICCIA) · doi:10.1109/iccia55271.2022.9828454 · Cited by 2
Mun, D. H., Chung, P., Woo, S. H., & Eom, J. B. (2022) · Lasers in Surgery and Medicine · doi:10.1002/lsm.23616 · Cited by 2
Attention Based Speckle Reduction for Optical Coherence Tomography in Ophthalmology and Dentistry
Ahmed, H., Zhang, Q., Donnan, R. S., & Alomainy, A. (2022) · International Congress on Image and Signal Processing (CISP) · doi:10.1109/cisp-bmei56279.2022.9979980 · Cited by 2
Cheung, R., Ly, A., Wang, H., Kalloniatis, M., & Nivison‐Smith, L. (2023) · BMJ Open · doi:10.1136/bmjopen-2023-077874 · Cited by 2
The application of functional imaging in visual field defects: a brief review
Cheng, W., Liu, J., Jiang, T., & Li, M. (2024) · Frontiers in Neurology · doi:10.3389/fneur.2024.1333021 · Cited by 2
Goswami, N., Anastasio, M. A., & Popescu, G. (2024) · Journal of Biomedical Optics · doi:10.1117/1.jbo.29.s2.s22714 · Cited by 2
Zhang, J., Zhou, M., Chen, Y., Chen, Z., Wang, H., Li, C., & He, Y. (2024) · IJC Heart & Vasculature · doi:10.1016/j.ijcha.2024.101513 · Cited by 2
An Efficient OCT Fingerprint Antispoofing Method Based on ResMamba
Xu, M., Chen, M., Lu, Z. H., Yang, S.-K., Lan, G., Huang, Y., Qin, J., An, L., Xu, J., & Cai, J. (2024) · Symmetry · doi:10.3390/sym16121603 · Cited by 2
Prabhu, V., Gandhi, P., Kathare, R., Godani, K., Hande, P., Yadav, N. K., Chhablani, J. K., & Venkatesh, R. (2024) · International Journal of Retina and Vitreous · doi:10.1186/s40942-024-00614-9 · Cited by 2
Dodoo, S., Ibrahim, S., Osman, A., Balaji, N., Salih, R., Kilaru, V., Ampadu, D. K., Dodoo, A. S., Egolum, U. O., Toleva, O., et al. (2024) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.31353 · Cited by 2
Intraoperative evaluation of the intestinal wall viability
Adamenkov, N. A., Mamoshin, A. V., Владимирович, Д. В., Potapova, E., Шуплецов, В. В., Ivanov, Y. V., Panchenkov, D. N., & Dunaev, A. (2024) · Journal of clinical practice · doi:10.17816/clinpract633149 · Cited by 2
Contextual Self-Attention Based UNet Architecture for Fluid Segmentation in Retinal OCT B-scans
Kalita, H., Dandapat, S., & Bora, P. K. (2024) · Indian Conference on Computer Vision, Graphics and Image Processing · doi:10.1145/3702250.3702291 · Cited by 2
Lefebvre, A. T., Steiner, N., Rodriguez, C. L., Angelo, J. P., Bar-Kochba, E., Mathur, R., Mirski, M. A., & Blodgett, D. W. (2025) · Neurotherapeutics · doi:10.1016/j.neurot.2024.e00520 · Cited by 2
Li, X., Lei, C. S., Ning, R., Liu, L., Chen, A., Yang, X., Savini, G., Schiano‐Lomoriello, D., Zhou, X., & Huang, J. (2025) · Eye and Vision · doi:10.1186/s40662-024-00422-0 · Cited by 2
Biochemical state in tissue can be detected through ultrasound signal
Ito, K., Iijima, Y., Misumi, T., Hayase, G., Tamura, K., Ikushima, K., & Yoshino, D. (2025) · npj Biomedical Innovations. · doi:10.1038/s44385-025-00026-w · Cited by 2
Netzhautsprechstunde im Jahr 2030
Kern, C., & Kortuem, K. (2020) · Der Ophthalmologe · doi:10.1007/s00347-020-01111-8 · Cited by 2
Jung, J. J., Chan, X., Lim, S. Y., Lee, S. S., Rofagha, S., & Hoang, Q. V. (2023) · Translational Vision Science & Technology · doi:10.1167/tvst.12.3.30 · Cited by 2
Maloca, P. M., Zarranz‐Ventura, J., Valmaggia, P., Faludi, B., Żelechowski, M., Tufail, A., Zentai, N., Scholl, H. P. N., & Cattin, P. C. (2023) · Scientific Reports · doi:10.1038/s41598-023-37267-x · Cited by 2
Ma, Y., Dong, R., Song, T., Zhou, M., Bai, J., Wang, S., Bell, B. A., & Zhang, P. (2024) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ad89cc · Cited by 2
Jacobs, F. J. C., Groenhuis, V., de Jong, I. M., Nagtegaal, I. D., Rovers, M. M., Bulte, G. J., & Fütterer, J. J. (2024) · Surgical Endoscopy · doi:10.1007/s00464-024-11353-1 · Cited by 2
Brais-Brunet, S., Boudoux, C., & Dehaes, M. (2025) · Experimental Eye Research · doi:10.1016/j.exer.2024.110229 · Cited by 2
Angelsky, O. V., Zenkova, C. Y., Ivanskyi, D. I., & Ursuliak, Y. (2025) · Optical Memory and Neural Networks · doi:10.3103/s1060992x24602045 · Cited by 2
Sood, A., Paliwal, R. O., & Mishra, R. Y. (2021) · Galician Medical Journal · doi:10.21802/gmj.2021.4.7 · Cited by 2
Optical Coherence Tomography in Diabetic Retinopathy
Ruia, S., & Tripathy, K. (2022) · IntechOpen eBooks · doi:10.5772/intechopen.100587 · Cited by 2
Changes in retinal structures as markers of multiple sclerosis progression
Poplyak, M. O., Trufanov, A. G., Temniy, A. V., Maltsev, D. S., Chakchir, O. B., Miheev, A. V., Skulyabin, D. I., Бисага, Г. Н., Litvinenko, I., & Odinak, M. M. (2021) · Neurology neuropsychiatry Psychosomatics · doi:10.14412/2074-2711-2021-6-55-61 · Cited by 2
Polarization-Enabled Optical Spectroscopy and Microscopic Techniques for Cancer Diagnosis
Divya, M., Hegde, M., Hegde, M., Roy, S., Raju, G., Nikolaev, V. V., Kistenev, Y. V., & Mazumder, N. (2023) · Biological and medical physics, biomedical engineering · doi:10.1007/978-3-031-31852-8_12 · Cited by 2
Zhang, T., Liao, J., Zhang, Y., Huang, Z., & Li, C. (2024) · Diagnostics · doi:10.3390/diagnostics14141509 · Cited by 2
Novel Method to Measure Volumes of Retinal Specific Entities
Lippera, M., Ferrara, M., Spiess, K., Alnafisee, N., Ally, N., Jalil, A., Ivanova, T., & Moussa, G. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13164620 · Cited by 2
Abaxi, S. M. D., Nawaz, M., Shi, P., Hao, W., Abbasi, S. A., & Yuan, W. (2023) · doi:10.36227/techrxiv.22308655 · Cited by 2
Bioinspired fluidic design for additive manufacturingPreprint
Shaqfeh, E. S. G., Lipkowitz, G., Krishna, N., Coates, I. A., & DeSimone, J. M. (2023) · Research Square · doi:10.21203/rs.3.rs-3483118/v1 · Cited by 2
Liu, Y., Li, W., Zhang, X., Lin, H., Li, D., & Li, Z. (2024) · Journal of Biophotonics · doi:10.1002/jbio.202400116 · Cited by 1
Aoun, S. B., Sassi, H., Mzoughi, K., Saidane, S., Ferchichi, M., Fekih, K., & Cheour, M. (2024) · European Journal of Ophthalmology · doi:10.1177/11206721241262838 · Cited by 1
Kerna, N. A., Ngwu, D. C., Kadivi, K., Carsrud, N. D. V., Pruitt, K. D., Flores, J. V., Holets, H. M., Jomsky, B. M., Chawla, S., Azi, C. I., et al. (2024) · European Journal of Medical and Health Research · doi:10.59324/ejmhr.2024.2(5).16 · Cited by 1
Explainable AI For Retinal Pathology Detection In OCT Images
Haddad, Z., Zgolli, H., Désiré Sidibé, A., Tabia, H., & Khlifa, N. (2024) · International Conference on Control, Decision and Information Technologies (CoDIT) · doi:10.1109/codit62066.2024.10708276 · Cited by 1
Arun, P. S., Francis, B., & Gopi, V. P. (2024) · IEEE Transactions on Artificial Intelligence · doi:10.1109/tai.2024.3491935 · Cited by 1
An optical coherence tomography study of a photoactive Pt( iv ) prodrug in oesophageal tissue
Shi, H., Mohan, M., Singh, K., & Sadler, P. J. (2025) · RSC Advances · doi:10.1039/d4ra08693g · Cited by 1
Optomechanical Properties of Swine Skin Tissue Treated With a Nontoxic Optical Clearing Agent
Correa, N., Suh, M., Mohizin, A., Sudhakaran, J., Lee, K. S., & Kim, J. K. (2025) · Journal of Biophotonics · doi:10.1002/jbio.70007 · Cited by 1
Wong, M. S., Wu, C., Chang, Y.-C., & Chen, H. (2025) · Diagnostics · doi:10.3390/diagnostics15101256 · Cited by 1
Clouston, S., Jonas, K. G., Lyketsos, C. G., Lian, W. X., Yang, Y., Harvey, P. D., Bromet, E. J., & Kotov, R. (2025) · Schizophrenia Bulletin · doi:10.1093/schbul/sbaf080 · Cited by 1
Bhat, M. A., & Goyal, S. (2025) · Stem Cell Reviews and Reports · doi:10.1007/s12015-025-10927-3 · Cited by 1
Optical Imaging of Articular Cartilage: Current Status and Clinical Applications
Gopinatth, V., Ashford, A., Lake, S. P., Smith, M. V., & Knapik, D. M. (2025) · Journal of Orthopaedic Research® · doi:10.1002/jor.70074 · Cited by 1
Controllable Acoustofluidic Rotation and Three-Dimensional Reconstruction of Single Cells
Li, L. L., Zhu, B., Bai, C., Chen, Z., Li, Y., Liu, F., Huang, Q., Arai, T., & Liu, X. (2025) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems67320.2025.11169924 · Cited by 1
Lin, K.-M., Shih, M.-K., Liang, Y.-X., & Hsiao, W.-T. (2025) · International Symposium on Communications and Information Technologies · doi:10.1109/iscit67082.2025.11231578 · Cited by 1
Real-time and non-invasive monitoring of plant signaling by means of optical coherence tomography
Chauvet, A. A. P., & Matcher, S. J. (2025) · Frontiers in Plant Science · doi:10.3389/fpls.2025.1702810 · Cited by 1
Tate, A. J., Mouradian, G. C., & Lipinski, D. M. (2025) · Biomedical Optics Express · doi:10.1364/boe.575278 · Cited by 1
Matteson, A., Helms, M., Fraley, L., Hurt, A., Andrews, A., White, E., Yang, P. G., Everett, L. A., & Chen, S. (2026) · Scientific Reports · doi:10.1038/s41598-025-32728-x · Cited by 1
Madariaga, A., Lohr, M. J., Lin, C.-Y., Fuhg, J. N., Tepole, A. B., & Rausch, M. K. (2026) · Experimental Mechanics · doi:10.1007/s11340-026-01267-5 · Cited by 1
Le, V., El-Mulki, O. S., Zhang, Y., Pan, H., Kumar, S., Shen, M., Beqiri, S., Badla, O., Berni, A., Kastner, J. D., et al. (2026) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.67.4.43 · Cited by 1
Sag, A. T., Yazgı, H., Özülken, K., & Eroğlu, E. (2024) · International Journal of Neuroscience · doi:10.1080/00207454.2024.2358367 · Cited by 1
Krause, M., Grannonico, M., Tyler, B. P., Miller, D. A., Fan, W., Liu, M., Kuranov, R. V., Zhang, H. F., Liu, X., & Netland, P. A. (2024) · Case Reports in Ophthalmological Medicine · doi:10.1155/2024/5823455 · Cited by 1
Lee, C. N., Wafa, H. A., Murphy, G. S. P., Galloway, J. B., Mahroo, O. A., & Jackson, T. L. (2024) · BMJ Open Ophthalmology · doi:10.1136/bmjophth-2024-001898 · Cited by 1
Metadata
- Authors
- Aumann, S., Donner, S., Fischer, J., & Müller, F.
- Affiliations
- Heidelberg Engineering (Germany) (DE)
- Venue
- High Resolution Imaging in Microscopy and Ophthalmology
- Publisher
- Springer International Publishing
- Published
- 2019
- Pages
- 59-85
- OpenAlex
- W2967073593
- Cited by
- 449
- References
- 46
- Citations by year
- 2026: 41 · 2025: 112 · 2024: 109 · 2023: 71 · 2022: 70 · 2021: 31 · 2020: 15
- FWCI
- 44.32
- Type
- book chapter
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Springer eBooks (publishedVersion, cc-by)
- Funders
- Heidelberg Engineering GmbH
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Optical Coherence Tomography Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Adaptive optics and wavefront sensing
- Keywords
- optical coherence tomography, retinal imaging, near-infrared light, interferometry, axial resolution, penetration depth, confocal scanning laser ophthalmoscope, motion tracking, image segmentation, depth measurement, tissue elasticity imaging, imaging speed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review