The DOI matches its Crossref record; 45 of the 46 references it cites were found in a registry or an index.
Optical Coherence Tomography (OCT): Principle and Technical Realization
Open accessAbstract
Optical coherence tomography (OCT) is a non-invasive technique for cross-sectional tissue imaging. It typically uses light in the near-infrared spectral range which has a penetration depth of several hundred microns in tissue. The backscattered light is measured with an interferometric set-up to reconstruct the depth profile of the sample at the selected location. A scanning OCT beam allows for acquisition of cross-sectional images of the tissue structure. Different technical methods are introduced and compared regarding their properties like sensitivity, imaging speed and penetration depth. Regardless of the technical realization, axial resolution and imaging range of an OCT system are determined by light source and detector characteristics. Combining retinal OCT with a confocal scanning laser ophthalmoscope allows for motion tracking during acquisition and to examine the exact same position at any time again. Segmentation of features is the basis for automatic depth measurements and standardized measurements to be compared with normative databases. New trends show the ability of functional OCT to image flow, polarizing properties of tissue and even mechanical properties like elasticity. Recent approaches to improve the resolution and the acquisition speed show the ongoing research interest in OCT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“OCT imaging at depth is negatively affected by absorption with light absorption and attenuation in upper tissue layers leading to less light reaching lower layers.”
From Effect of skin color on optical properties and the implications for medical optical technologies: a review (2024) · cites this paper as [85]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K. W., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 14,001
Optical coherence tomography - principles and applications
FERCHER, A. F., Drexler, W., Hitzenberger, C. K. F., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,871
Performance of fourier domain vs time domain optical coherence tomography
Leitgeb, R. A., Hitzenberger, C. K. F., & FERCHER, A. F. (2003) · Optics Express · doi:10.1364/oe.11.000889 · Cited by 1,859
Sensitivity advantage of swept source and Fourier domain optical coherence tomography
Choma, M. A., Šarunic, M. V., Yang, C., & Izatt, J. A. (2003) · Optics Express · doi:10.1364/oe.11.002183 · Cited by 1,789
de Boer, J. F., Cense, B., Park, B. H., Pierce, M. C., Tearney, G. J., & Bouma, B. E. (2003) · Optics Letters · doi:10.1364/ol.28.002067 · Cited by 1,245
Measurement of intraocular distances by backscattering spectral interferometry
FERCHER, A. F., Hitzenberger, C. K. F., Kamp, G., & El-Zaiat, S. Y. (1995) · Optics Communications · doi:10.1016/0030-4018(95)00119-s · Cited by 1,208
von Braunmühl, T. (2015) · Der Hautarzt · doi:10.1007/s00105-015-3607-z · Cited by 1,036
Huber, R. A., Wojtkowski, M., & Fujimoto, J. G. (2006) · Optics Express · doi:10.1364/oe.14.003225 · Cited by 982
Refractive indices of water and ice in the 065- to 25-μm spectral range
Kou, L., Labrie, D., & Chýlek, P. (1993) · Applied Optics · doi:10.1364/ao.32.003531 · Cited by 804
Optical coherence tomography using a frequency-tunable optical source
Chinn, S. R., Swanson, E. A., & Fujimoto, J. G. (1997) · Optics Letters · doi:10.1364/ol.22.000340 · Cited by 666
Cited by
Sorted by citations
Items 401–449 of 449
Optical Low-Coherence Tomography (OCT)
Masters, B. R. (2025) · Springer series in optical sciences/SPringer series in optical sciences · doi:10.1007/978-3-031-87711-7_18
Material Surface Analysis Based on SD-OCT
Rodrigues, V. J. C., Medeiros, E. L., Brandão, T. H., Garcia, J. M. L., Simões, F. D., & Pataca, D. M. (2025) · SBFoton International Optics and Photonics Conference (SBFoton IOPC) · doi:10.1109/sbfotoniopc66433.2025.11218392
Carvalho, R. L., Brito, F. L. C., Rocha, M. F. X., Ledbetter, E. C., Voitena, J. N., & Montiani-Ferreira, F. (2025) · Research Square · doi:10.21203/rs.3.rs-8011911/v1
Diagnosing Eosinophilic Chronic Rhinosinusitis in Excised Tissue Using Optical Coherence Tomography
Badash, I., Serafino, M. J., Correa, A. J., Oghalai, J. S., Wrobel, B., Applegate, B. E., & Hur, K. (2025) · The Laryngoscope · doi:10.1002/lary.70285
Kim, H., Bok, J., Han, S., Jeon, M., & Kim, J. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.117319
A MEMS on Fiber Multisensor Platform for Surgical Assistance
Teymoori, M., Zolfaghari, P., Ferhanoğlu, O., Tümer, M., & Yalcinkaya, A. D. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3641792
Macular thickness in children with strabismic amblyopia using optical coherence tomography (OCT)
Alnuaimy, M. E. J., Hussein, Z. R., & Alhasseny, K. F. (2025) · Ophthalmology Journal · doi:10.5603/oj.103494
Jeong, M., Kim, J., Lee, H., & Kim, C.-S. (2025) · European Conferences on Biomedical Optics (ECBO) · doi:10.1364/ecbo.2025.w3a.15
Fardha, H. R., Primitasari, Y., Yuliawati, T. H., & Abdullah, M. R. (2025) · Magna Scientia Advanced Research and Reviews · doi:10.30574/msarr.2025.15.2.0158
Advancements in Light-Sheet Fluorescence Microscopy for Three Dimensional Cellular Spheroid Imaging
Mishra, A., & Arora, V. (2025) · Tissue Engineering Part B Reviews · doi:10.1177/19373368251406951
Javed, M., Saigol, H. K., Ahmed, N. I., Rauf, A., Chauhan, K., Afzal, S., & Mahmood, U. (2025) · Pakistan Journal of Health Sciences · doi:10.54393/pjhs.v6i12.3559
Optical Coherence Tomography and Voice-Related Biomarkers
Pedersen, M. (2026) · Springer eBooks · doi:10.1007/978-3-032-03134-1_13
Pedersen, M., Nashaat, N. H., Camesasca, V., Villoria, R. H., & Das, S. (2026) · Springer eBooks · doi:10.1007/978-3-032-03134-1 · Cited by 1
Bearce, B., McNamara, S., Kinder, S., Manoharan, N., Lisker-Cervantes, A., Arguinchona, L., Marks, B., Roseto, I. C., Barrientos, L., Milner, D. C., et al. (2026) · Translational Vision Science & Technology · doi:10.1167/tvst.15.1.12
Alhamamy, M. F., Jarjees, M. S., & Hasan, W. Z. W. (2025) · NTU Journal of Engineering and Technology · doi:10.56286/v3x8ga74
¿Cómo diagnosticar Neurofibromatosis tipo 1?Preprint
Algara-Ramírez, C., Vidal-Millán, S., García-Ortega, D. Y., & Wegman-Ostrosky, T. (2026) · doi:10.1590/scielopreprints.14805
Multimodal imaging for early drusen detection: RM-SLO as a promising imaging approach
Zhang, S., Zhang, X., Wang, Z., Shi, W., Ren, Z., Wang, Y., Jia, Q., Li, Y., Guo, Y., & Li, Z. (2026) · Frontiers in Medicine · doi:10.3389/fmed.2025.1703332
TDOCT with Optical Delay Line based on Static Helicoid Mirror
Kolokoltsev, O. V., Avendaño‐Alejo, M., Gómez-Arista, I., Qureshi, N., & Mejía-Uriarte, E. V. (2025) · Journal of Applied Research and Technology · doi:10.22201/icat.24486736e.2025.23.6.2743
Microneedle-mediated Administration of Drug Nanocrystals
López-Vidal, L., Catlin, E. J., Donnelly, R. F., & Paredes, A. J. (2026) · Springer eBooks · doi:10.1007/978-3-032-10238-6_6
Quantum-locked tomography for turbulence immune 3D imaging at the micron scale
Yang, K., Huang, R., Li, Y., Liu, B., Wen, L., Liang, C., Zhao, R., Wang, C., Xue, X., & Dou, X. (2026) · Photonics Research · doi:10.1364/prj.587135
Lan, Q., Huang, J. I., Huang, C., Song, S., Shi, Y., Zhao, Z., Wu, W., Chen, H., & Liu, N. (2026) · Bioengineering · doi:10.3390/bioengineering13030332
Wu, Z., Shen, Y., Ng, E. Y. K., Huang, C., Lan, Q., Ren, L., & Li, J. (2026) · Scientific Reports · doi:10.1038/s41598-026-43601-w
Segmentation-Enhanced Deep Learning for AMD Detection from OCT Images
Haddad, Z., Elhoula, S., Désiré Sidibé, A., Tabia, H., Zeghal, I., & Khlifa, N. (2025) · IEEE International Conference on Advances in Data-Driven Analytics and Intelligent Systems (ADACIS) · doi:10.1109/adacis65663.2025.11437195
Garzozi, D., Carmel, M., Neuman, G., Lisitsky, A., Bracha, Z., Givoni, H., Brosh, K., Kratz, A., Imtirat, A., Zadok, D., et al. (2026) · Diagnostics · doi:10.3390/diagnostics16071066
Kumaran, S. L., Sri, G. K. R., Thomas, B. E., & Selvister, S. M. (2026) · SAGE Open Medical Case Reports · doi:10.1177/2050313x261436550
Diagnostic automatisé des pathologies de la rétine à l'aide des volumes OCT
Safarjalani, R. (2020) · theses.fr (ABES) · doi:10.70675/9fab8ce5z31e1z4fd0z86aez2ab2f205a18a
Développement d’outils d’analyse du remodelage matriciel par imagerie haute résolution
Zemzem, A. B. (2022) · theses.fr (ABES) · doi:10.70675/37e7a7a7z184cz4152z8e85z7e8884840ea3
Agarwal, V., & Yesha, Y. (2026) · International Conference on Artificial Intelligence, Computer, Data Sciences and Applications (ACDSA) · doi:10.1109/acdsa67686.2026.11467930
Hernández‐García, E., Burgos‐Blasco, B., Güemes-Villahoz, N., Morales‐Fernández, L., Fernández‐Vigo, J. I., Santos-Bueso, E., de Liaño, R. G., & Garcia-Feijoo, J. (2026) · Frontiers in Pediatrics · doi:10.3389/fped.2026.1792500
Aghamirsalim, M., Khabazkhoob, M., Emamian, M. H., Hashemi, H., Heydarian, S., & Fotouhi, A. (2026) · Scientific Reports · doi:10.1038/s41598-026-52064-y
Eyes on the Future: Preventing Vision Loss and Retinopathy
Sarkar, R., Ghosal, R. K., Banerjee, K., Banerjee, P., & Maiti, R. (2026) · Springer eBooks · doi:10.1007/978-981-95-8946-3_5
Douglas, B. K., Huihui, Z., & Etheresia, P. (2026) · Cardiovascular Science · doi:10.70322/cvs.2026.10005
Single-shot imaging of phase objects fully enclosed by dynamic scattering layers
Kim, Y.-S., Song, G., Kim, H., Lee, C., & Jang, M. (2026) · Optica · doi:10.1364/optica.593328
Performance Validation of Optical Coherence Tomography for Non-Destructive Plant Health Diagnosis
Sasi, G. S., & Chauvet, A. A. P. (2026) · IntechOpen eBooks · doi:10.5772/intechopen.1016591
Spectral-Domain Low-Coherence Measurement Method for Variable-Diameter Narrow Long Spaces
Zhang, T., Xia, R., Fu, S., Zhu, G., & Zhao, J. (2026) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2026.3709601
Şensoy, E., Çıtırık, M., & Eryılmaz, M. E. (2026) · Indian Journal of Ophthalmology · doi:10.4103/ijo.ijo_3235_25
Medghalchi, A., Kanafi, A. R., Alizadeh, Y., Baghersalimi, A., Doorandish, M., Rad, A. H., Kianmehr, S., & Darbandi, B. (2026) · Health Science Reports · doi:10.1002/hsr2.73053
Optical Fiber Micro–Nano Axicon
Mondal, S. K., Gupta, P., Vairagi, K., & Kaur, J. (2026) · CRC Press eBooks · doi:10.1201/9781003647959
Galvez, M. C., Barlisan, A. M., Hermosilla, E., Tabafa, M. N., Macalalad, E. P., Esmeria, J. M., Vallar, E. A., Okaneya, S., Cadondon, J. G., & Shiina, T. (2026) · Dentistry Journal · doi:10.3390/dj14090563
Erdogan, K., Ünlü, M., & Ozer, F. (2026) · International Ophthalmology · doi:10.1007/s10792-026-04227-z
Vijayan, M., Veerapu, G., & Nisha, J. S. (2026) · Frontiers in Artificial Intelligence · doi:10.3389/frai.2026.1925302
Зенкова, К., Ivanskyi, D. I., Ангельський, О., Riabyi, P. A., Коняхін, А., Дяченко, М., & Джанг, К. (2026) · Physics and Chemistry of Solid State · doi:10.15330/pcss.27.3.481-486
Sultana, N., & Poddar, R. (2026) · Biofouling · doi:10.1080/08927014.2026.2736790
Ocular Coherence Tomography in Ophthalmology: Clinical Applications for Selected Topics
Macher, J., & Zein, L. E. (2026) · IntechOpen eBooks · doi:10.5772/intechopen.1016621
Experimental study on the influence of pupil diameter on laser‐induced retinal damage effects
Zukang, 聂. N., Mengqi, Q., Litong, 朱. Z., Jiarui, W., Jiao, L., Su, B., Guo, R., & Yang, Z. (2026) · Photochemistry and Photobiology · doi:10.1111/php.70147
Başkan, B., & Evcimen, Y. (2026) · Seminars in Ophthalmology · doi:10.1080/08820538.2026.2747762
Efficient Medical Image Compression using a CNN and Discrete Wavelet Transform
Chikhaoui, D., Beladgham, M., & Aissa, M. B. (2026) · Journal of Elecetrical Engineering and Renewable Energies Development · doi:10.66950/xt6hw312
Ometto, G., Muhundhakumar, D., Montesano, G., Adesanya, J., Webster, P., Pachilova, R., Symons, A., Ramsay, A., Clarke, C., Ndwandwe, S., et al. (2026) · British Journal of Ophthalmology · doi:10.1136/bjo-2026-330227
Metadata
- Authors
- Aumann, S., Donner, S., Fischer, J., & Müller, F.
- Affiliations
- Heidelberg Engineering (Germany) (DE)
- Venue
- High Resolution Imaging in Microscopy and Ophthalmology
- Publisher
- Springer International Publishing
- Published
- 2019
- Pages
- 59-85
- OpenAlex
- W2967073593
- Cited by
- 449
- References
- 46
- Citations by year
- 2026: 41 · 2025: 112 · 2024: 109 · 2023: 71 · 2022: 70 · 2021: 31 · 2020: 15
- FWCI
- 44.32
- Type
- book chapter
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Springer eBooks (publishedVersion, cc-by)
- Funders
- Heidelberg Engineering GmbH
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Optical Coherence Tomography Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Adaptive optics and wavefront sensing
- Keywords
- optical coherence tomography, retinal imaging, near-infrared light, interferometry, axial resolution, penetration depth, confocal scanning laser ophthalmoscope, motion tracking, image segmentation, depth measurement, tissue elasticity imaging, imaging speed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review