The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Meta-rPPG: Remote Heart Rate Estimation Using a Transductive Meta-learner
Open accessOverview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hochreiter, S., & Schmidhuber, J. (1997) · Neural Computation · doi:10.1162/neco.1997.9.8.1735 · Cited by 102,318
Histograms of Oriented Gradients for Human Detection
Dalal, N., & Triggs, B. (2005) · 2005 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR'05) · doi:10.1109/cvpr.2005.177 · Cited by 33,584
Model-Agnostic Meta-Learning for Fast Adaptation of Deep Networks
Finn, C., Abbeel, P., & Levine, S. (2017) · arXiv · doi:10.48550/arxiv.1703.03400 · Cited by 8,512
Stacked Hourglass Networks for Human Pose Estimation
Newell, A., Yang, K., & Deng, J. (2016) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-46484-8_29 · Cited by 5,634
On First-Order Meta-Learning Algorithms
Nichol, A., Achiam, J., & Schulman, J. (2018) · arXiv · doi:10.48550/arxiv.1803.02999 · Cited by 1,438
Robust pulse rate from chrominance-based rPPG
de Haan, G., & Jeanne, V. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2266196 · Cited by 1,378
Algorithmic principles of remote PPG
Wang, W., den Brinker, A. C., Stuijk, S., & de Haan, G. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2609282 · Cited by 1,234
Dynamic Few-Shot Visual Learning Without Forgetting
Gidaris, S., & Komodakis, N. (2018) · 2018 IEEE/CVF Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2018.00459 · Cited by 1,128
Heart rate measurement based on a time-lapse image.
Takano, C., & Ohta, Y. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.09.006 · Cited by 345
The advantages of wearable green reflected photoplethysmography
Maeda, Y., Sekine, M., & Tamura, T. (2011) · Journal of Medical Systems · doi:10.1007/s10916-010-9506-z · Cited by 209
Cited by
PhysFormer: Facial Video-based Physiological Measurement with Temporal Difference Transformer
Yu, Z., Shen, Y., Shi, J., Zhao, H., Torr, P., & Zhao, G. (2022) · 2022 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr52688.2022.00415 · Cited by 300
PhysFlow: Skin tone transfer for remote heart rate estimation through conditional normalizing flows
Comas, J., Alomar, A., Ruiz, A., & Sukno, F. (2024) · arXiv · doi:10.48550/arxiv.2407.21519 · Cited by 4
“Other recent works [24, 29] explore unsupervised approaches using meta-learning, enhancing generalization in out-of-distribution cases.”
Background
Metadata
- Authors
- Lee, E., Chen, E., & Lee, C.-Y.
- Venue
- Lecture Notes in Computer Science
- Publisher
- Springer International Publishing
- Published
- 2020
- Pages
- 392-409
- ISSN
- 0302-9743 (ISSN-L)
- 1611-3349
- OpenAlex
- W3042432770
- Cited by
- 181
- References
- 10
- FWCI
- 49.52
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Meta-rPPG: Remote Heart Rate Estimation Using a Transductive Meta-learner. https://app.cochat.ai/papers/10.1007/978-3-030-58583-9_24
- The paper
- Lee, E., Chen, E., & Lee, C.-Y. (2020). Meta-rPPG: Remote Heart Rate Estimation Using a Transductive Meta-learner. Lecture Notes in Computer Science. https://doi.org/10.1007/978-3-030-58583-9_24
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.