The advantages of wearable green reflected photoplethysmography
Abstract
This report evaluates the efficacy of reflected-type green light photoplethysmography (green light PPG). Transmitted infrared light was used for PPG and the arterial pulse was monitored transcutaneously. The reflected PPG signal contains AC components based on the heartbeat-related signal from the arterial blood flow and DC components, which include reflectance and scattering from tissue. Generally, changes in AC components are monitored, but the DC components play an important role during heat stress. In this study, we compared the signal of green light PPG to infrared PPG and ECG during heat stress. The wavelengths of the green and infrared light were 525 nm and 880 nm, respectively. Experiments were performed on young healthy subjects in cold (10°C), hot (45°C), and normal environments. The pulse rates were compared among three measurement devices and the AC and DC components of the PPG signal were evaluated during heat stress. The pulse rates obtained from green light PPG were strongly correlated with the R-R interval of an electrocardiogram in all environments, but those obtained from infrared light PPG displayed a weaker correlation with cold exposure. The AC components were of similar signal output for both wavelengths during heat stress. Also, the DC components for green light PPG were similar during heat stress, but showed less signal output for infrared light PPG during hot exposure. The main reason for the reduced DC components was speculated to be the increased blood flow at the vascular bed. Therefore, reflected green light PPG can be useful for pulse rate monitoring because it is less influenced by the tissue and vein region.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The Mio Alpha's PPG technology was previously validated against a standard electrocardiogram (ECG).
“The Mio Alpha's PPG technology was previously validated against a standard electrocardiogram (ECG) (Maeda, Sekine, Tamura, 2011a)”
From Examining the Role of Implicit Emotional Judgments in Social Anxiety and Experiential Avoidance (2017) · cites this paper as Maeda, Sekine, Tamura, 2011a
Green light is preferred to red and infrared because it does not penetrate deep into tissue, causing fewer artifacts from a non-pulsatile slow-changing component.
“Green is preferred to red and infrared since this wavelength does not penetrate deep into tissue causing fewer artifacts from a non-pulsatile slow-changing component [55].”
From Modeling of artifacts in the wrist photoplethysmogram: Application to the detection of life-threatening arrhythmias (2021) · cites this paper as [55]
Studies on healthy adults with different skin pigmentation showed that red and green wavelengths could estimate oxygen saturation with good agreement and lower error ratio compared to the traditional pulse oximeter.
“Studies on healthy adults with different skin pigmentation showed that red and green wavelengths could estimate oxygen saturation with good agreement and lower error ratio compared to the traditional pulse oximeter [30,80,102].”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [102]
Cites
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967 · see citing works
Anderson, R. R., & Parrish, J. A. (1981) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12479191 · Cited by 2,456 · see citing works
Mobile monitoring with wearable photoplethysmographic biosensors
Asada, H. H., Shaltis, P., Reisner, A., Rhee, S., & Hutchinson, R. C. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213624 · Cited by 466 · see citing works
THE BLOOD SUPPLY OF VARIOUS SKIN AREAS AS ESTIMATED BY THE PHOTOELECTRIC PLETHYSMOGRAPH
Hertzman, A. B. (1938) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1938.124.2.328 · Cited by 455 · see citing works
Pulsed multifrequency photoplethysmograph
Giltvedt, J., Sira, A., & Helme, P. (1984) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442745 · Cited by 47 · see citing works
Green Light Photoplethysmography Monitoring of Free Flaps
Futran, N. D., Stack, B. C., Hollenbeak, C. S., & Scharf, J. (2000) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.126.5.659 · Cited by 35 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Wearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912 · see citing works
Self-citationPhotoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. V. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 567 · see citing works
Physiological parameter monitoring from optical recordings with a mobile phone
Scully, C. G., Lee, J., Meyer, J., Gorbach, A. M., Granquist-Fraser, D., Mendelson, Y., & Chon, K. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2163157 · Cited by 452 · see citing works
Soft wearable devices for deep-tissue sensing
Lin, M., Hu, H., Zhou, S., & Xu, S. H. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00427-y · Cited by 349 · see citing works
Biswas, D., Everson, L. R., Liu, M., Panwar, M., Verhoef, B.-E., Patki, S., Kim, C. H., Acharyya, A., Hoof, C. A. V., Konijnenburg, M., et al. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2892297 · Cited by 293 · see citing works
Heart Rate Estimation From Wrist-Worn Photoplethysmography: A Review
Biswas, D., Simões‐Capela, N., Hoof, C. A. V., & Helleputte, N. V. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2914166 · Cited by 263 · see citing works
Wearable Photoplethysmography for Cardiovascular Monitoring
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3149785 · Cited by 250 · see citing works
Current progress of photoplethysmography and SPO2 for health monitoring
TAMURA, T. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-019-00097-w · Cited by 260 · see citing works
Self-citationJinno, H., Yokota, T., Koizumi, M., Yukita, W., Saito, M., Osaka, I., Fukuda, K., & Someya, T. (2021) · Nature Communications · doi:10.1038/s41467-021-22558-6 · Cited by 253 · see citing works
Soft Bioelectronics Based on Nanomaterials
Cho, K. W., Sunwoo, S., Hong, Y. J., Koo, J. H., Kim, J. H., Baik, S., Hyeon, T., & Kim, D. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00531 · Cited by 247 · see citing works
Kim, K. B., & Baek, H. J. (2023) · Electronics · doi:10.3390/electronics12132923 · Cited by 238 · see citing works
Validity of Wearable Activity Monitors during Cycling and Resistance Exercise
BOUDREAUX, B. D., HEBERT, E. P., HOLLANDER, D. B., WILLIAMS, B. M., CORMIER, C. L., NAQUIN, M. R., GILLAN, W. W., GUSEW, E. E., & KRAEMER, R. R. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001471 · Cited by 205 · see citing works
Meta-rPPG: Remote Heart Rate Estimation Using a Transductive Meta-learner
Lee, E., Chen, E., & Lee, C. (2020) · Lecture notes in computer science · doi:10.1007/978-3-030-58583-9_24 · Cited by 199 · see citing works
The 2023 wearable photoplethysmography roadmap
Charlton, P. H., Allen, J., Bailón, R., Baker, S., Behar, J. A., Chen, F., Clifford, G. D., Clifton, D. A., Davies, H. J., Ding, C., et al. (2023) · Physiological Measurement · doi:10.1088/1361-6579/acead2 · Cited by 210 · see citing works
Self-citationA Review of Wearable Multi-Wavelength Photoplethysmography
Ray, D., Collins, T., Woolley, S., & Ponnapalli, P. (2023) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3121476 · Cited by 155 · see citing works
Comparative evaluation of heart rate-based monitors: Apple Watch vs Fitbit Charge HR
Bai, Y., Hibbing, P. R., Mantis, K., & Welk, G. J. (2017) · Journal of Sports Sciences · doi:10.1080/02640414.2017.1412235 · Cited by 147 · see citing works
Cabanas, A. M., Fuentes-Guajardo, M., Latorre, K., León, D., & Martín-Escudero, P. (2022) · Sensors · doi:10.3390/s22093402 · Cited by 124 · see citing works
A deep transfer learning approach for wearable sleep stage classification with photoplethysmography
Radha, M., Fonseca, P. M., Moreau, A., Ross, M., Cerny, A., Anderer, P., Long, X., & Aarts, R. M. (2021) · npj Digital Medicine · doi:10.1038/s41746-021-00510-8 · Cited by 122 · see citing works
Franklin, D., Tzavelis, A., Lee, J. Y., Chung, H. U., Trueb, J. T., Arafa, H., Kwak, S. S., Huang, I. A., Liu, Y., Rathod, M., et al. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01098-y · Cited by 119 · see citing works
Mühlen, J. M., Stang, J. S., Skovgaard, E. L., Júdice, P. B., Molina‐García, P., Johnston, W., Sardinha, L. B., Ortega, F. B., Caulfield, B., Bloch, W., et al. (2021) · British Journal of Sports Medicine · doi:10.1136/bjsports-2020-103148 · Cited by 118 · see citing works
Past, Present, and Future of Multisensory Wearable Technology to Monitor Sleep and Circadian Rhythms
Lujan, M. R., Perez-Pozuelo, I., & Grandner, M. A. (2021) · Frontiers in Digital Health · doi:10.3389/fdgth.2021.721919 · Cited by 115 · see citing works
Wearable Photoplethysmography for Cardiovascular Monitoring.
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · KTUePubl (Repository of Kaunas University of Technology) · doi:10.17863/cam.81148 · Cited by 113 · see citing works
ETA-rPPGNet: Effective Time-Domain Attention Network for Remote Heart Rate Measurement
Hu, M. Q., Qian, F., Guo, D., Wang, X., He, L., & Ren, F. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3058983 · Cited by 109 · see citing works
Shakerian, S., Habibnezhad, M., Ojha, A., Lee, G., Liu, Y., Jebelli, H., & Lee, S. H. (2021) · Safety Science · doi:10.1016/j.ssci.2021.105395 · Cited by 111 · see citing works
Origin of Photoplethysmographic Waveform at Green Light
Kamshilin, A. A., & Борисович, М. Н. (2017) · Physics Procedia · doi:10.1016/j.phpro.2017.01.024 · Cited by 90 · see citing works
Zhang, Y., Weaver, R. G., Armstrong, B., Burkart, S., Zhang, S., & Beets, M. W. (2020) · Journal of Sports Sciences · doi:10.1080/02640414.2020.1767348 · Cited by 88 · see citing works
Matsumura, K., & Yamakoshi, T. (2013) · Behavior Research Methods · doi:10.3758/s13428-012-0312-z · Cited by 87 · see citing works
Dcosta, J. V., Ochoa, D., & Sanaur, S. (2023) · Advanced Science · doi:10.1002/advs.202302752 · Cited by 86 · see citing works
JAMSNet: A Remote Pulse Extraction Network Based on Joint Attention and Multi-Scale Fusion
Zhao, C., Wang, H., Chen, H.-L., Shi, W., & Feng, Y.-J. (2023) · IEEE transactions on circuits and systems for video technology (Print) · doi:10.1109/tcsvt.2022.3227348 · Cited by 77 · see citing works
Comparison of Polar M600 Optical Heart Rate and ECG Heart Rate during Exercise
HORTON, J. F., STERGIOU, P., FUNG, T. S., & KATZ, L. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001388 · Cited by 79 · see citing works
Matsumura, K., Rolfe, P. J., Lee, J., & Yamakoshi, T. (2014) · PLoS ONE · doi:10.1371/journal.pone.0091205 · Cited by 72 · see citing works
Pulse-Glasses: An unobtrusive, wearable HR monitor with Internet-of-Things functionality
Constant, N. P., Douglas-Prawl, O., Johnson, S., & Mankodiya, K. (2015) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2015.7299350 · Cited by 70 · see citing works
Xu, S., Momin, M., Ahmed, S., Hossain, A., Veeramuthu, L., Pandiyan, A., Kuo, C., & Zhou, T. (2023) · Advanced Materials · doi:10.1002/adma.202303267 · Cited by 67 · see citing works
Advances in Biointegrated Wearable and Implantable Optoelectronic Devices for Cardiac Healthcare
Li, C., Bian, Y., Zhao, Z., Liu, Y., & Guo, Y. (2024) · Cyborg and Bionic Systems · doi:10.34133/cbsystems.0172 · Cited by 69 · see citing works
Video capillaroscopy clarifies mechanism of the photoplethysmographic waveform appearance
Volkov, M. V., Борисович, М. Н., Potemkin, A. V., Volynsky, M. A., Gurov, I. P., Mamontov, O. V., & Kamshilin, A. A. (2017) · Scientific Reports · doi:10.1038/s41598-017-13552-4 · Cited by 65 · see citing works
Blood pressure estimation from pulse wave velocity measured on the chest
Puke, S., Suzuki, T., Kanako, N., Tanaka, H., & Minami, S. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610946 · Cited by 63 · see citing works
Liu, H., Wang, Y., & Wang, L. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346371 · Cited by 60 · see citing works
Marzorati, D., Bovio, D., Salito, C., Mainardi, L. T., & Cerveri, P. (2020) · IEEE Access · doi:10.1109/access.2020.2981300 · Cited by 57 · see citing works
In-Ear Pulse Rate Measurement: A Valid Alternative to Heart Rate Derived from Electrocardiography?
Passler, S., Müller, N., & Senner, V. (2019) · Sensors · doi:10.3390/s19173641 · Cited by 55 · see citing works
Robust Heart Rate Estimation With Spatial–Temporal Attention Network From Facial Videos
Hu, M. Q., Qian, F., Wang, X., He, L., Guo, D., & Ren, F. (2021) · IEEE Transactions on Cognitive and Developmental Systems · doi:10.1109/tcds.2021.3062370 · Cited by 55 · see citing works
Harju, J., Tarniceriu, A., Parák, J., Vehkaoja, A. T., Yli‐Hankala, A., & Korhonen, I. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aac9a9 · Cited by 55 · see citing works
Prabha, A., Yadav, J., Rani, A., & Singh, V. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.103876 · Cited by 56 · see citing works
Li, J., Chu, H., Chen, Z., Yiu, C. K., Qu, Q., Li, Z.-Y., & Yu, X. (2024) · ACS Nano · doi:10.1021/acsnano.4c04291 · Cited by 50 · see citing works
Photoplethysmogram at green light: Where does chaos arise from?
Sviridova, N., Zhao, T., Aihara, K., Nakamura, K., & Nakano, A. (2018) · Chaos Solitons & Fractals · doi:10.1016/j.chaos.2018.09.016 · Cited by 52 · see citing works
A robust heart rate detection using smart-phone video
Pal, A., Sinha, A., Choudhury, A. D., Chattopadyay, T., & Visvanathan, A. (2013) · International Workshop on Pervasive Wireless Healthcare · doi:10.1145/2491148.2491156 · Cited by 50 · see citing works
Zanelli, S., Ammi, M., Hallab, M., & El‐Yacoubi, M. A. (2022) · Sensors · doi:10.3390/s22134890 · Cited by 53 · see citing works
Validity of heart rate measurements by the Garmin Forerunner 225 at different walking intensities
Claes, J., Buys, R., Ávila, A., Finlay, D., Kennedy, A., Guldenring, D., Budts, W., & Cornelissen, V. (2017) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2017.1333166 · Cited by 49 · see citing works
A Review of Methods for Non-Invasive Heart Rate Measurement on Wrist
De Pinho Ferreira, N., Gehin, C., & Massot, B. (2021) · IRBM · doi:10.1016/j.irbm.2020.04.001 · Cited by 49 · see citing works
Harmonic sum-based method for heart rate estimation using PPG signals affected with motion artifacts
Dubey, H., Kumaresan, R., & Mankodiya, K. (2016) · Journal of Ambient Intelligence and Humanized Computing · doi:10.1007/s12652-016-0422-z · Cited by 39 · see citing works
Is Continuous Heart Rate Monitoring of Livestock a Dream or Is It Realistic? A Review
Nie, L., Berckmans, D., Wang, C., & Li, B. (2020) · Sensors · doi:10.3390/s20082291 · Cited by 43 · see citing works
Peláez‐Coca, M. D., Hernando, A., Lázaro, J. M., & Gil, E. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2021.3099208 · Cited by 41 · see citing works
Using photoplethysmography in heart rate monitoring of patients with epilepsy
van Andel, J., Ungureanu, C., Aarts, R., Leijten, F., & Arends, J. (2015) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2015.02.018 · Cited by 39 · see citing works
Zhou, C., Feng, J., Hu, J. H., & Ye, X. (2015) · Journal of Medical Systems · doi:10.1007/s10916-015-0412-2 · Cited by 38 · see citing works
Determinants of photoplethysmography signal quality at the wrist
Charlton, P. H., Marozas, V., Mejía‐Mejía, E., Kyriacou, P. A., & Mant, J. (2025) · PLOS Digital Health · doi:10.1371/journal.pdig.0000585 · Cited by 38 · see citing works
Chen, W., Yi, Z., Lim, L. J. R., Lim, R. Q. R., Zhang, A., Qian, Z., Huang, J., He, J., & Лю, Б. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1420100 · Cited by 39 · see citing works
Li, F., Xu, P., Zheng, S., Chen, W., Yang, Y., Lu, S., & Liu, Z. (2018) · International Journal of Distributed Sensor Networks · doi:10.1177/1550147718803298 · Cited by 34 · see citing works
Monolithic InGaN/GaN photonic chips for heart pulse monitoring
Chen, L., Wu, Y., & Li, K. H. (2020) · Optics Letters · doi:10.1364/ol.400733 · Cited by 34 · see citing works
Origin of Infrared Light Modulation in Reflectance-Mode Photoplethysmography
Sidorov, I. S., Владимирович, Р. Р., Koval, V. T., Giniatullin, R. A., & Kamshilin, A. A. (2016) · PLoS ONE · doi:10.1371/journal.pone.0165413 · Cited by 34 · see citing works
Video pulse rate variability analysis in stationary and motion conditions
Rodríguez, A., & Ramos-Castro, J. J. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0437-0 · Cited by 34 · see citing works
Zhong, Y., Koklu, A., Villalva, D. R., Zhang, Y., Hernandez, L. H., Moser, M., Hallani, R. K., McCulloch, I. A., Baran, D., & Inal, S. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202211479 · Cited by 33 · see citing works
Berwal, D., Kuruba, A., Shaikh, A. M., Udupa, A., & Baghini, M. S. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3170069 · Cited by 32 · see citing works
MW-PPG Sensor: An on-Chip Spectrometer Approach
Chang, C.-C., Wu, C.-T., Choi, B. I., & Fang, T.-J. (2019) · Sensors · doi:10.3390/s19173698 · Cited by 30 · see citing works
Respiratory rate derived from smartphone-camera-acquired pulse photoplethysmographic signals
Lázaro, J. M., Nam, Y., Gil, E., Laguna, P., & Chon, K. H. (2015) · Physiological Measurement · doi:10.1088/0967-3334/36/11/2317 · Cited by 30 · see citing works
A Monolithically Processed Rectifying Pixel for High‐Resolution Organic Imagers
Zalar, P., Matsuhisa, N., Suzuki, T., Enomoto, S., Koizumi, M., Yokota, T., Sekino, M., & Someya, T. (2018) · Advanced Electronic Materials · doi:10.1002/aelm.201700601 · Cited by 31 · see citing works
Mathew, J., Zheng, D., Xu, J., & Liu, H. (2024) · Advanced Electronic Materials · doi:10.1002/aelm.202300765 · Cited by 30 · see citing works
Validation of nocturnal resting heart rate and heart rate variability in consumer wearables
Dial, M. B., Hollander, M. E., Vatne, E. A., Emerson, A. M., Edwards, N. A., & Hagen, J. A. (2025) · Physiological Reports · doi:10.14814/phy2.70527 · Cited by 27 · see citing works
Yamakoshi, Y., Matsumura, K., Yamakoshi, T., Lee, J., Rolfe, P. J., Kato, Y., Shimizu, K., & Yamakoshi, K.-I. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.6.067001 · Cited by 27 · see citing works
A Noninvasive Blood Glucose Estimation System Using Dual-Channel PPGs and Pulse-Arrival Velocity
Lee, P., Wang, K., & Hsiao, C. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3306343 · Cited by 26 · see citing works
Matsumura, K., Toda, S., & Kato, Y. (2020) · IEEE Access · doi:10.1109/access.2020.2990438 · Cited by 27 · see citing works
Paliakaitė, B., Petrėnas, A., Sološenko, A., & Marozas, V. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102421 · Cited by 24 · see citing works
Measurement of Pulsation Strain at the Fingertip Using a Plastic FBG Sensor
Koyama, S., Haseda, Y., Ishizawa, H., Okazaki, F., Bonefacino, J., & Tam, H. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3079432 · Cited by 24 · see citing works
Valenti, S., Volpes, G., Parisi, A., Peri, D., Lee, J., Faes, L., Busacca, A., & Pernice, R. (2023) · Biosensors · doi:10.3390/bios13040460 · Cited by 24 · see citing works
Bridging Gaps in Wearable Technology for Exercise and Health Professionals: A Brief Review
Schumann, M., & Doherty, C. (2024) · International Journal of Sports Medicine · doi:10.1055/a-2376-6332 · Cited by 21 · see citing works
Park, P., Lee, W., & Cho, S. (2023) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2023.3315297 · Cited by 23 · see citing works
Papini, G. B., Fonseca, P. M., van Gilst, M. M., Bergmans, J. W. M., Vullings, R., & Overeem, S. (2020) · Physiological Measurement · doi:10.1088/1361-6579/ab9481 · Cited by 22 · see citing works
Ribeiro, G., Postolache, O. A., & Ferrero, F. J. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3342218 · Cited by 21 · see citing works
A highly efficient and reliable heart rate monitoring system using smartphone cameras
Lomaliza, J.-P., & Park, H. (2016) · Multimedia Tools and Applications · doi:10.1007/s11042-016-4010-1 · Cited by 21 · see citing works
Hendrikx, J., Ruijs, L. S., Cox, L. G. E., Lemmens, P. M. C., Schuijers, E. G., & Goris, A. H. C. (2017) · JMIR mhealth and uhealth · doi:10.2196/mhealth.6893 · Cited by 19 · see citing works
Renwrantz, L. R., & Spielvogel, F. (2011) · Comparative Biochemistry and Physiology Part A Molecular & Integrative Physiology · doi:10.1016/j.cbpa.2011.08.002 · Cited by 20 · see citing works
Reynolds, J., Ahmmed, P., & Bozkurt, A. Y. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2923153 · Cited by 19 · see citing works
Validity of the Polar Vantage M watch when measuring heart rate at different exercise intensities
Shumate, T., Link, M., Furness, J. W., Kemp‐Smith, K., Simas, V., & Climstein, M. (2021) · PeerJ · doi:10.7717/peerj.10893 · Cited by 18 · see citing works
Beyond Mobile Apps: A Survey of Technologies for Mental Well-Being
Woodward, K., Kanjo, E., Brown, D. J., McGinnity, T. M., Inkster, B., Macintyre, D. J., & Tsanas, A. (2022) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2020.3015018 · Cited by 18 · see citing works
Kim, D., Lee, E., Kim, J., Park, P., & Cho, S. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2950367 · Cited by 18 · see citing works
Organic Photoplethysmography Sensors for Wearable Health Monitoring
Chen, L., Wang, Y., Wen, Y., Zhang, L., Liu, S., & Xie, W. (2025) · Laser & Photonics Review · doi:10.1002/lpor.202401992 · Cited by 18 · see citing works
iFidgetCube: Tangible Fidgeting Interfaces (TFIs) to Monitor and Improve Mental Wellbeing
Woodward, K., & Kanjo, E. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3031163 · Cited by 17 · see citing works
Non-invasive heart rate measuring smartphone applications using on-board cameras: A short survey
Papon, T. I., Ahmad, I., Saquib, N., & Rahman, A. (2015) · International Conference on Networking, Systems and Security (NSysS) · doi:10.1109/nsyss.2015.7043533 · Cited by 17 · see citing works
Yamakoshi, T., Lee, J., Matsumura, K., Yamakoshi, Y., Rolfe, P. J., Kiyohara, D., & Yamakoshi, K.-I. (2015) · PLoS ONE · doi:10.1371/journal.pone.0143506 · Cited by 17 · see citing works
Pont, M. P. D., & Marques, J. L. B. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2963508 · Cited by 17 · see citing works
Liu, X., Yang, X., Jin, J., & Wong, A. K. C. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.2984881 · Cited by 17 · see citing works
Physiological signals anticipatory computing for individual emotional state and creativity thinking
Lai, C., Lai, Y.-H., Hwang, R., & Huang, T. (2018) · Computers in Human Behavior · doi:10.1016/j.chb.2018.05.015 · Cited by 17 · see citing works
Zhang, X., Lyu, Y., Luo, X., Zhang, J., Yu, C., Yin, H., & Shi, Y. (2018) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3214290 · Cited by 17 · see citing works
Examining the Role of Implicit Emotional Judgments in Social Anxiety and Experiential Avoidance
Levin, M. E., Haeger, J., & Smith, G. S. (2017) · Journal of Psychopathology and Behavioral Assessment · doi:10.1007/s10862-016-9583-5 · Cited by 16 · see citing works
Yan, J., Ye, Z., Shi, F., Dai, Y., Yang, L., Wu, J., & Wang, Y. (2021) · Biomedical Optics Express · doi:10.1364/boe.437805 · Cited by 16 · see citing works
A Biometric Authentication Technique Using Smartphone Fingertip Photoplethysmography Signals
Ortiz, B. L., Chong, J. W., Gupta, V., Shoushan, M. M., Jung, K., & Dallas, T. E. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3176248 · Cited by 17 · see citing works
Sensor organic light-emitting diode display, combining fingerprint and biomarker capturing
Kim, C., Bae, K. S., Kim, G.-H., Lee, D., Moon, G., Yang, D., Lee, H., An, J., Park, J., Yoon, S., et al. (2024) · Communications Engineering · doi:10.1038/s44172-024-00239-8 · Cited by 16 · see citing works
Ye, Z., Yan, J., Gao, X., Jia, B., Guan, Q., Fu, K., Wang, L., Zhu, H., Ji, X., & Wang, Y. (2021) · Advanced Engineering Materials · doi:10.1002/adem.202100829 · Cited by 16 · see citing works
iPhysioMeter: A Smartphone Photoplethysmograph for Measuring Various Physiological Indices
Matsumura, K., Rolfe, P. J., & Yamakoshi, T. (2014) · Methods in molecular biology · doi:10.1007/978-1-4939-2172-0_21 · Cited by 17 · see citing works
(2016) · doi:10.1109/embc.2016.7590774 · Cited by 20 · see citing works
THE BIOPHYSICAL PARAMETER MEASUREMENTS FROM PPG SIGNAL
Bhat, S., Adam, M., Hagiwara, Y., & Ng, E. Y. K. (2017) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s021951941740005x · Cited by 16 · see citing works
Yang, Z., Wang, H., Liu, B., & Lu, F. (2023) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2023.3314282 · Cited by 14 · see citing works
- Authors
- Maeda, Y., Sekine, M., & Tamura, T.
- Affiliations
- Chiba University (JP)
- Corresponding author
- Maeda, Yuka
- Venue
- Journal of Medical Systems
- Published
- 2010-05-18
- Volume
- 35
- Issue
- 5
- Pages
- 829-834
- ISSN
- 0148-5598 (ISSN-L)
- 1573-689X
- OpenAlex
- W2040137929
- Cited by
- 209
- References
- 6
- Citations by year
- 2026: 12 · 2025: 23 · 2024: 15 · 2023: 20 · 2022: 22 · 2021: 25 · 2020: 15 · 2019: 17 · 2018: 13 · 2017: 19 · 2016: 5 · 2015: 9 · 2014: 7 · 2013: 3 · 2012: 1
- FWCI
- 1.32
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Journal of Medical Systems (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Keywords
- heat stress, pulse rate monitoring, wearable sensors, cold exposure, vascular blood flow
- MeSH terms
- Adult, Blood Pressure Determination, Color, Humans, Infrared Rays, Monitoring, Physiologic, Skin Temperature, Photoplethysmography, Young Adult, Wavelet Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review