Fully Automatic and Real-Time Catheter Segmentation in X-Ray Fluoroscopy
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Augmenting X-ray imaging with 3D roadmap to improve guidance is a common strategy. Such approaches benefit from automated analysis of the X-ray images, such as the automatic detection and tracking of instruments. In this paper, we propose a real-time method to segment the catheter and guidewire in 2D X-ray fluoroscopic sequences. The method is based on deep convolutional neural networks. The network takes as input the current image and the three previous ones, and segments the catheter and guidewire in the current image. Subsequently, a centerline model of the catheter is constructed from the segmented image. A small set of annotated data combined with data augmentation is used to train the network. We trained the method on images from 182 X-ray sequences from 23 different interventions. On a testing set with images of 55 X-ray sequences from 5 other interventions, a median centerline distance error of 0.2 mm and a median tip distance error of 0.9 mm was obtained. The segmentation of the instruments in 2D X-ray sequences is performed in a real-time fully-automatic manner.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“However, since existing large-scale hip datasets have focused on 3D image modalities and pre and postoperative radiography, rather than intraoperative fluoroscopy [12], applications of CNNs to fluoroscopy have been mostly limited to recognizing surgical instruments and tools [13-16].”
From Automatic Annotation of Hip Anatomy in Fluoroscopy for Robust and Efficient 2D/3D Registration (2020) · cites this paper as [14]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474 · cited 1×
“Moreover, batch normalization [8] and residual learning [6] have been proposed to improve training convergence.”
BackgroundU-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
Fully convolutional networks for semantic segmentation
Long, J., Shelhamer, E., & Darrell, T. (2015) · 2015 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2015.7298965 · Cited by 38,834
(2014) · Cited by 33,419
Batch Normalization: Accelerating Deep Network Training by Reducing Internal Covariate Shift
Ioffe, S., & Szegedy, C. (2015) · arXiv · doi:10.48550/arxiv.1502.03167 · Cited by 27,818 · cited 2×
“I i 1;:::I i 3. The output is the image prediction Bp i . For the network topology, see Figure 1. To improve convergence speed during training, we add batch normalization (BN) after every convolution [8]. In order to also learn how to downsample/upsample the features we use strided convolutions [10,14]. To prevent ove…”
BackgroundMethodBatch Normalization: Accelerating Deep Network Training by Reducing Internal Covariate Shift
Ioffe, S. (2024) · arXiv (Cornell University) · doi:10.57702/o9raffed · Cited by 14,214
V-Net: Fully Convolutional Neural Networks for Volumetric Medical Image Segmentation
Milletari, F., Navab, N., & Ahmadi, S.-A. (2016) · 2016 Fourth International Conference on 3D Vision (3DV) · doi:10.1109/3dv.2016.79 · Cited by 11,931 · cited 4×
“In order to also learn how to downsample/upsample the features we use strided convolutions [10, 14].”
BackgroundMethodInfluentialStriving for Simplicity: The All Convolutional Net
Springenberg, J. T., Dosovitskiy, A., Brox, T., & Riedmiller, M. (2014) · arXiv · doi:10.48550/arxiv.1412.6806 · Cited by 3,447 · cited 2×
“In order to also learn how to downsample/upsample the features we use strided convolutions [10, 14].”
BackgroundMethodA fast parallel algorithm for thinning digital patterns
Zhang, T. Y., & Suen, C. Y. (1984) · Communications of the ACM · doi:10.1145/357994.358023 · Cited by 2,756 · cited 1×
“The output of the neural network is first thresholded with a threshold α (between 0 and 1) and then skeletonized [19].”
MethodGuide-wire tracking during endovascular interventions
Baert, S. A. M., Viergever, M. A., & Niessen, W. J. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815904 · Cited by 102
Self-citation
Cited by
(2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-66185-8 · Cited by 377
Applications of artificial intelligence in cardiovascular imaging
Sermesant, M., Delingette, H., Cochet, H., Jaïs, P., & Ayache, N. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-021-00527-2 · Cited by 170
Modarai, B., Haulon, S., Ainsbury, E. A., Böckler, D., Vañó-Carruana, E., Dawson, J. A., Farber, M. A., HERZEELE, I. V., Hertault, A., van Herwaarden, J. A., et al. (2022) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2022.09.005 · Cited by 164
DeepDRR – A Catalyst for Machine Learning in Fluoroscopy-Guided Procedures
Unberath, M., Zaech, J.-N., Lee, S. C., Bier, B., Fotouhi, J., Armand, M., & Navab, N. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-00937-3_12 · Cited by 145
“Despite clear opportunities, in particular for prediction tasks, very little work has considered learning in this context [4,5,6,7].”
BackgroundCAI4CAI: The Rise of Contextual Artificial Intelligence in Computer Assisted Interventions
Vercauteren, T., Unberath, M., Padoy, N., & Navab, N. (2020) · Proceedings of the IEEE · doi:10.1109/jproc.2019.2946993 · Cited by 125
“…in depth in Section V, and focusing first on interventional X-ray imaging, benefits of real-time machine learning range from segmentation of tools [53], [81], [82], anatomical landmark detection [51], [52], anatomy localization [83], and denoising [84], [85], to surgical phase recognition [81].”
BackgroundAutomatic Annotation of Hip Anatomy in Fluoroscopy for Robust and Efficient 2D/3D Registration
Grupp, R. B., Unberath, M., Gao, C., Hegeman, R. A., Murphy, R. J., Alexander, C. P., Otake, Y., McArthur, B. A., Armand, M., & Taylor, R. H. (2020) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-020-02162-7 · Cited by 83
Sequential vessel segmentation via deep channel attention network
Hao, D., Ding, S. Z., Qiu, L., Lv, Y., Fei, B., Zhu, Y., & Qin, B. (2020) · Neural Networks · doi:10.1016/j.neunet.2020.05.005 · Cited by 90
“, 2019), X-ray net,7 (Ambrosini et al., 2017) short connected deep supervised net (BTS-DSN)8 (Guo et al.”
BackgroundGherardini, M., Mazomenos, E. B., Menciassi, A., & Stoyanov, D. V. (2020) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2020.105420 · Cited by 67
Ma, H., Smal, I., Daemen, J., & van Walsum, T. (2020) · Medical Image Analysis · doi:10.1016/j.media.2020.101634 · Cited by 68
“Some methods mainly relied on a detection model, but incorporate temporal information in the preprocessing ([7]) or post-processing ([16]) step or in the input ([33, 1]).”
MethodA survey of catheter tracking concepts and methodologies
Ramadani, A., Bui, M., Wendler, T., Schunkert, H., Ewert, P., & Navab, N. (2022) · Medical Image Analysis · doi:10.1016/j.media.2022.102584 · Cited by 66
Artificial intelligence in interventional radiology: state of the art
Glielmo, P., Fusco, S., Gitto, S., Zantonelli, G., Albano, D., Messina, C., Sconfienza, L. M., & Mauri, G. (2024) · European Radiology Experimental · doi:10.1186/s41747-024-00452-2 · Cited by 59
“Ambrosini et al. [18] introduced a fully automatic approach based on the U-Net model that can be run in real time for segmentation of catheter with no specific features.”
MethodXin, Y., Adams, S., Babyn, P., & Elnajmi, A. (2019) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-019-00201-7 · Cited by 65
“[2] to detect catheters on X-ray fluoroscopy but using a UNet-style [18] network.”
MethodAccurate vessel extraction via tensor completion of background layer in X-ray coronary angiograms
Qin, B., Jin, M., Hao, D., Lv, Y., Liu, Q., Zhu, Y., Ding, S. Z., Zhao, J., & Fei, B. (2018) · Pattern Recognition · doi:10.1016/j.patcog.2018.09.015 · Cited by 56
“…filter (Frangi’s) 8 [24], Coye’s method (Coye’s) 9 [74], Felfelian’s method [75], the MSRG (multiscale region growing) al-gorithm [76], CNN-Xray method designed for real-time fully-automatic catheter segmentation 10 [77], and the U-net based retinal blood vessels segmentation method 11 [78] .”
MethodPrime Time for Artificial Intelligence in Interventional Radiology
Seah, J. C. Y., Boeken, T., Sapoval, M. R., & Goh, G. S. (2022) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-021-03044-4 · Cited by 47
“Deep learning approaches have also been applied to identifying guidewire and catheters during angiography [26].”
MethodXin, Y., Adams, S., Henderson, R. D. E., & Babyn, P. (2020) · Radiology Artificial Intelligence · doi:10.1148/ryai.2020190082 · Cited by 47
“2 mm and 85% of the frames were within 1 mm of centerline distance error (44).”
BackgroundNguyen, A., Kundrat, D., Dagnino, G., Chi, W., Abdelaziz, M. E. M. K., Guo, Y., Ma, Y., Kwok, T. M. Y., Riga, C. V., & Yang, G. (2020) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra40945.2020.9197307 · Cited by 51
“Top row - original X-ray images; Second row - TCF [28]; Third row: Adaptive U-Net [42]; Fourth row: Siamese U-Net [27]; Fifth row: Our FW-Net.”
BackgroundMethodInfluentialYu, D., Zhang, K., Huang, L., Zhao, B., Zhang, X., Guo, X., Li, M., Gu, Z., Fu, G., Hu, M., et al. (2020) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2020.105674 · Cited by 44
Zhou, Y.-J., Xie, X., Zhou, X.-H., Liu, S.-Q., Bian, G., & Hou, Z. (2020) · IEEE Transactions on Cognitive and Developmental Systems · doi:10.1109/tcds.2020.3023952 · Cited by 43
“However, due to the disparate materials and diameter variance between catheters and guidewires, and training in the same network, the reported error of the guidewire is significantly higher than that of the catheter [28].”
BackgroundIntraoperative stent segmentation in X-ray fluoroscopy for endovascular aortic repair
Breininger, K., Albarqouni, S., Kurzendorfer, T., Pfister, M., Kowarschik, M., & Maier, A. (2018) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-018-1779-6 · Cited by 38
Real-Time Multi-Guidewire Endpoint Localization in Fluoroscopy Images
Li, R., Xie, X., Zhou, X.-H., Liu, S.-Q., Ni, Z.-L., Zhou, Y.-J., Bian, G., & Hou, Z. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3069998 · Cited by 42
Automated Detection and Type Classification of Central Venous Catheters in Chest X-Rays
Subramanian, V., Wang, H., Wu, J. T.-Y., Wong, K. C. L., Sharma, A., & Syeda-Mahmood, T. F. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-32226-7_58 · Cited by 32
Zhou, Y.-J., Xie, X., Zhou, X.-H., Liu, S.-Q., Bian, G., & Hou, Z. (2020) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2020.101734 · Cited by 31
Real-Time Pose Tracking for a Continuum Guidewire Robot Under Fluoroscopic Imaging
Ravigopal, S. R., Sarma, A., Brumfiel, T. A., & Desai, J. P. (2023) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2023.3260273 · Cited by 24
“In addition, [26] develops a method for autonomous detection of catheter shape, however, it also requires temporal information, as takes a sequence of four frames to determine the catheter shape.”
Method(2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-66182-7 · Cited by 23
A Tensor-Based Catheter and Wire Detection and Tracking Framework and Its Clinical Applications
Ma, Y., Zhou, D., Ye, L., Housden, R. J., Fazili, A., & Rhode, K. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3102670 · Cited by 23
Trivisonne, R., Kerrien, E., & Cotin, S. (2020) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2020.101702 · Cited by 21
“Several solutions have been proposed to detect and track a curve in an image sequence [37, 38, 39].”
BackgroundFekri, P., Khodashenas, H., Lachapelle, K. J., Cecere, R., Zadeh, M., & Dargahi, J. (2022) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2022.3148439 · Cited by 23
“This can be achieved by semantic segmentation methods [24], [25].”
BackgroundMethodUllah, I., Chikontwe, P., & Park, S. H. (2019) · IEEE Access · doi:10.1109/access.2019.2950263 · Cited by 20
“[33] introduced segmentation approaches using a U-net architecture [34] for tracking the guidewire in ultrasound images and X-ray fluoroscopic images, respectively.”
MethodAutomatic Guidewire Tip Segmentation in 2D X-ray Fluoroscopy Using Convolution Neural Networks
Wu, Y., Xie, X., Bian, G., Hou, Z., Cheng, X.-R., Chen, S., Liu, S., & Wang, Q.-L. (2018) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn.2018.8489337 · Cited by 25
“Manually annotations are finished as in [6].”
BackgroundMethodResultInfluentialAdvanced Robotics for the Next-Generation of Cardiac Interventions
Roshanfar, M., Salimi, M., Kaboodrangi, A. H., Jang, S.-J., Sinusas, A. J., Wong, S. C., & Mosadegh, B. (2025) · Micromachines · doi:10.3390/mi16040363 · Cited by 20
“AI-powered AI-powered image processing algorithms have the potential to reduce radiation dose while maintaining or improving image quality [22].”
Improved U-Net for Guidewire Tip Segmentation in X-ray Fluoroscopy Images
Guo, S., Songyuan, T., Zhu, J., Fan, J., Ai, D., Song, H., Liang, P., & Yang, J. (2019) · International Conference on Advances in Image Processing (ICAIP) · doi:10.1145/3373419.3373449 · Cited by 16
“[12] applied U-Net for the segmentation of an entire guidewire and utilized a post-processing procedure to connect the segmented branches into a complete guidewire.”
BackgroundMethodA Unified Framework for Multi-Guidewire Endpoint Localization in Fluoroscopy Images
Li, R., Xie, X., Zhou, X.-H., Liu, S.-Q., Ni, Z.-L., Zhou, Y.-J., Bian, G., & Hou, Z. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3118001 · Cited by 16
Multi-Stage Suture Detection for Robot Assisted Anastomosis Based on Deep Learning
Hu, Y., Gu, Y., Yang, J., & Yang, G. (2018) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2018.8461131 · Cited by 17
Cryo-balloon catheter localization in X-Ray fluoroscopy using U-net
Vernikouskaya, I., Bertsche, D., Dahme, T., & Rasche, V. (2021) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-021-02366-5 · Cited by 14
“Catheter shaft binary mask (maskshaft ctrl) was created from a centerline model build similarly as described in [4, 13] as the analytical representation of the cryo-balloon catheter shaft part close to the XR marker.”
MethodZhou, Y.-J., Xie, X., Hou, Z., Bian, G., Liu, S., & Zhou, X.-H. (2020) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi45749.2020.9098632 · Cited by 12
“Recently, an automatic approach in [5] tried to segment the whole catheter indiscriminately and required post-processing to link the segmented branches into a complete catheter, which is complicated and needless.”
BackgroundEfficient Medical Instrument Detection in 3D Volumetric Ultrasound Data
Yang, H., Shan, C., Kolen, A. F., & de With, P. H. N. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.2999729 · Cited by 12
“[14] proposed to use a 2D fully convolutional network (FCN) to segment complex cardiac catheters under 2D X-ray fluoroscopy for real-time applications.”
Jeong, D., Kim, D., Ryu, J., & Cho, K. H. (2021) · IEEE Access · doi:10.1109/access.2021.3098527 · Cited by 11
“• For automatic segmentation of real guidewire from live fluoroscopic images in real time, several methods [21]–[24] can be used.”
MethodDeep learning-based framework for motion-compensated image fusion in catheterization procedures
Vernikouskaya, I., Bertsche, D., Rottbauer, W., & Rasche, V. (2022) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2022.102069 · Cited by 11
Extracting heterogeneous vessels in X-ray coronary angiography via machine learning
Qin, B., Jin, M., & Ding, S. Z. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822706-0.00008-1 · Cited by 12
Omisore, O. M., Akinyemi, T. O., Duan, W., Du, W., & Wang, L. (2024) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2024.3369765 · Cited by 10
“Ambrosini et al. [35] developed a deep convolutional neural network (CNN) for segmentation in catheter in X-ray sequences acquired during catheterization.”
BackgroundMultiple Device Segmentation for Fluoroscopic Imaging Using Multi-task Learning
Breininger, K., Würfl, T., Kurzendorfer, T., Albarqouni, S., Pfister, M., Kowarschik, M., Navab, N., & Maier, A. (2018) · Lecture notes in computer science · doi:10.1007/978-3-030-01364-6_3 · Cited by 13
Toward Real-Time Pose Estimation of the Mitral Valve Robot Under C-Arm X-Ray Fluoroscopy
Ravigopal, S. R., Nayar, N. U., & Desai, J. P. (2021) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2021.3122351 · Cited by 11
Real-time guidewire tracking and segmentation in intraoperative x-ray
Zhang, B., Bui, M., Wang, C., Bourier, F. J., Schunkert, H., & Navab, N. (2022) · SPIE Medical Imaging: Image-Guided Procedures, Robotic Interventions, and Modeling · doi:10.1117/12.2611097 · Cited by 9
“In [5, 6], instead of segmenting the guidewire directly [7, 8], a detector is deployed first to output the bounding box of the guidewire, which could reduce the class imbalance of the segmentation task.”
MethodNeofytou, A. P., Kowalik, G. T., Shankar, R. V., Huang, L., Moon, T., Mellor, N., Razavi, R., Neji, R., Pushparajah, K., & Roujol, S. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1233093 · Cited by 10
Breininger, K., Hanika, M., Weule, M., Kowarschik, M., Pfister, M., & Maier, A. (2019) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-019-02052-7 · Cited by 10
“With the rise of deep learning,methods that employ neural networks have been investigated as well [2,6,9].”
MethodAghasizade, M., Kiyoumarsioskouei, A., Hashemi, S., Torabinia, M., Caprio, A., Rashid, M., Xiang, Y., Rangwala, H., Ma, T., Lee, B., et al. (2023) · Applied Sciences · doi:10.3390/app13137778 · Cited by 9
Prior-Free Respiratory Motion Estimation in Rotational Angiography
Unberath, M., Taubmann, O., Aichert, A., Achenbach, S. S., & Maier, A. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2806310 · Cited by 8
“to [52].”
Fully Automatic Dual-Guidewire Segmentation for Coronary Bifurcation Lesion
Zhou, Y.-J., Xie, X., Bian, G., Hou, Z., Wu, Y., Liu, S.-Q., Zhou, X.-H., & Wang, J. (2019) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn.2019.8851827 · Cited by 8
“The method in [14] tried to segment the whole catheter and guidewire.”
Zhou, Y.-J., Liu, S.-Q., Xie, X., Zhou, X.-H., Wang, G.-A., Hou, Z., Li, R., Ni, Z.-L., & Fan, C.-C. (2021) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra48506.2021.9560838 · Cited by 8
“However, due to differences in the diameter of the guidewire and the catheter, and training in the same network, the error reported by the guidewire is remarkably higher than that of the catheter [18].”
BackgroundA Two-Stage Framework for Real-Time Guidewire Endpoint Localization
Li, R., Bian, G., Zhou, X.-H., Xie, X., Ni, Z.-L., & Hou, Z. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-32254-0_40 · Cited by 8
Real-Time Guidewire Segmentation and Tracking in Endovascular Aneurysm Repair
Zhou, Y.-J., Xie, X., Bian, G., Hou, Z., Liu, B., Lai, Z., Qu, X., Liu, S.-Q., & Zhou, X.-H. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-36708-4_40 · Cited by 8
Jiang, S., Teng, S., Lü, J., Wang, C., Wen, T., Zhu, J., & Teng, G. (2021) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-021-02529-4 · Cited by 7
“The difference between ours and Ambrosini [10] is that [10] treats topology-level repairing as a postprocessing step independent to neural-network-based pixel-level segmentation and ours embeds these two into one learning procedure.”
InfluentialLi, W., Que, D., & Omisore, O. M. (2021) · International Conference on Robotics and Automation Sciences (ICRAS) · doi:10.1109/icras52289.2021.9476273 · Cited by 7
“However, due to the differences of materials and diameter between catheter and guidewire, the reporting accuracy of the guidewire is obviously lower than catheter when training in the same network [9].”
BackgroundUneri, A., Wu, P., Jones, C. K., Vagdargi, P., Han, R., Helm, P. A., Luciano, M. G., Anderson, W. S., & Siewerdsen, J. H. (2021) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ac2f89 · Cited by 8
Patient-specific Cardio-respiratory Motion Prediction in X-ray Angiography using LSTM Networks
Azizmohammadi, F., Navarro-Castellanos, I., Miró, J., Segars, W. P., Samei, E., & Duong, L. (2022) · Physics in Medicine and Biology · doi:10.1088/1361-6560/acaba8 · Cited by 7
“For input, the network takes the current and the three previous images and segments the catheter and guidewire in the current image ( Ambrosini et al 2017 ) .”
MethodSoni, L., Soopramanien, J., Acharya, A., Ashrafian, H., Giannarou, S., Fotiadis, N., & Darzi, A. W. (2025) · La radiologia medica · doi:10.1007/s11547-025-02013-y · Cited by 7
“Deep learning approaches in interventional radiology have identified catheters and guidewires during angiography [40], which may lead to real-time road-mapping of vasculature without the need for contrast [41].”
A Multi-Stage Guidewire Tip Tracking Framework for Cardiovascular Robotic Interventions
Zhu, J., Wang, C. H., Zhang, G., Teng, S., Lu, L., & Teng, G. (2021) · International Congress on Image and Signal Processing (CISP) · doi:10.1109/cisp-bmei53629.2021.9624418 · Cited by 6
“[6] presented UNet and a centerline model in catheter segmentation, obtaining a median centerline distance error of 0.”
MethodTowards Occlusion-Aware Pose Estimation of Surgical Suturing Threads
Gu, Y., Yang, J., & Yang, G. (2022) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2022.3198402 · Cited by 6
“ear objects in medical or surgical application including vessel segmentation [23], [24], [25], airway reconstruction [26], fissure segmentation [27] and catheter guide-wire detection [16].”
BackgroundMethodInfluentialLightweight Double Attention-Fused Networks for Intraoperative Stent Segmentation
Zhou, Y.-J., Xie, X., Hou, Z., Zhou, X.-H., Bian, G., & Liu, S.-Q. (2020) · Lecture notes in computer science · doi:10.1007/978-3-030-59725-2_1 · Cited by 6
Synthesize and Segment: Towards Improved Catheter Segmentation via Adversarial Augmentation
Ullah, I., Chikontwe, P., Choi, H., Yoon, C., & Park, S. H. (2021) · Applied Sciences · doi:10.3390/app11041638 · Cited by 7
“[25] employed similar approaches for catheter segmentation in ultrasound and X-ray images using a UNet [26] architecture.”
MethodPark, S., Ki, Y., Park, S., Chung, M. J., & Kim, K. (2023) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2023.102643 · Cited by 5
Vessel-targeted compensation of deformable motion in interventional cone-beam CT
Lu, A., Huang, H., Hu, Y., Zbijewski, W. B., Unberath, M., Siewerdsen, J. H., Weiss, C. R., & Sisniega, A. (2024) · Medical Image Analysis · doi:10.1016/j.media.2024.103254 · Cited by 5
An Interventional Radiologist’s Primer of Critical Appraisal of Artificial Intelligence Research
Gaddum, O., & Chapiro, J. (2023) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2023.09.020 · Cited by 9
Prasong, P., Xie, X., & Hou, Z. (2019) · IET Image Processing · doi:10.1049/iet-ipr.2018.6652 · Cited by 5
“After that, convolutional neural networks (ConvNet) are proposed [23, 24].”
BackgroundTargeted deformable motion compensation for vascular interventional cone-beam CT imaging
Sisniega, A., Lu, A., Huang, H., Zbijewski, W. B., Unberath, M., Siewerdsen, J. H., & Weiss, C. R. (2022) · SPIE Medical Imaging: Physics of Medical Imaging · doi:10.1117/12.2613232 · Cited by 5
“The segmentation is performed using a deep-CNN that features an encoder-decoder architecture with skip residual connections, similar to U-Net designs, and following an approach similar to Ref.(13) The 2D vessel maps are subsequently backprojected and threshold to obtain an approximate 3-dimensional mask encompassing t…”
MethodFlores, J. V. Z., & Radoux, J.-P. (2022) · IRBM · doi:10.1016/j.irbm.2022.09.004 · Cited by 5
Move Over There: One-Click Deformation Correction for Image Fusion During Endovascular Aortic Repair
Breininger, K., Pfister, M., Kowarschik, M., & Maier, A. (2020) · Lecture notes in computer science · doi:10.1007/978-3-030-59719-1_69 · Cited by 5
Guide3D: A Bi-planar X-ray Dataset for 3D Shape Reconstruction
Jianu, T., Huang, B., Nguyen, H., Bhattarai, B., Do, T., Tjiputra, E., Tran, Q. D., Berthet-Rayne, P., Le, N., Fichera, S., et al. (2024) · Lecture notes in computer science · doi:10.1007/978-981-96-0917-8_21 · Cited by 7
Robust navigation support in lowest dose image setting
Bui, M., Bourier, F. J., Baur, C., Milletarì, F., Navab, N., & Demirci, S. (2018) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-018-1874-8 · Cited by 4
Bi-directional Encoding for Explicit Centerline Segmentation by Fully-Convolutional Networks
Sirazitdinov, I., Saalbach, A., Schulz, H., & Dylov, D. V. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-16440-8_66 · Cited by 4
Shape-Sensitive Loss for Catheter and Guidewire Segmentation
Kongtongvattana, C., Huang, B., Kang, J., Nguyen, H. A., Olajide, O., & Nguyen, A. (2024) · Lecture notes in networks and systems · doi:10.1007/978-3-031-70684-4_8 · Cited by 4
Catheter detection and segmentation in X-ray images via multi-task learning
Lin, X., Ma, Y., Koland, E., Howell, S., Rinaldi, C. A., & Rhode, K. (2025) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-025-03461-7 · Cited by 5
“Learning-based approaches have been developed to build a shape template to continuously track guidewires [8, 9].”
SplineFormer: An Explainable Transformer Network for Autonomous Endovascular Navigation
Jianu, T., Doust, S., Li, M., Huang, B., Do, T., Nguyen, H., Bates, K. T., Ta, T. D., Fichera, S., Berthet-Rayne, P., et al. (2025) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros60139.2025.11246898 · Cited by 3
“In particular, U-Net-based architectures [32] have achieved state-of-the-art performance in segmenting guidewires from X-ray images, with refinements such as Recurrent Neural Networks (RNN) and adaptive binarization further improving accuracy [33], [34].”
Template-based balloon-marker and guidewire detection for coronary stents in cardiac fluoroscopy
Kotb, A. G., Mahmoud, A. M., & Rushdi, M. A. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871789 · Cited by 3
“Recently, convolutional neural network (CNN) techniques were used for guidewire detection ([10], [11] and [12]).”
MethodModel-Based Pose Estimation of Steerable Catheters under Bi-Plane Image Feedback
Lawson, J., Chitale, R. V., & Simaan, N. (2023) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra48891.2023.10161314 · Cited by 5
A Survey on the Progress of Computer-Assisted Vascular Intervention
Li, N., He, J., Chen, Y., & Zhou, S. (2022) · Journal of Computer-Aided Design & Computer Graphics · doi:10.3724/sp.j.1089.2022.19038 · Cited by 2
“Ambrosini 等 [73] 将 Petkovi ć 等 [74] 和 Yatziv 等 [75] 基于背景估计方法分 Chang 等 [77] 概率提升树 [82] 构建分类器区分图像中含有导丝 / 导 管尖端的区域 ; Pauly 等 [83] 采用支持向量机 (support [84] .”
Martin, G., Becq, A., Isabelle Bloch, A., Camus, M., Pinna, A., & Szewczyk, J. (2024) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi56570.2024.10635427 · Cited by 2
“Ambrosini et al. [5] used U-Net [2] and an algorithm of branch connection on sequences of images.”
MethodShape-Sensitive Loss for Catheter and Guidewire SegmentationPreprint
Kongtongvattana, C., Huang, B., Kang, J., Nguyen, H. A., Olajide, O., & Nguyen, A. H. T. (2023) · arXiv (Cornell University) · doi:10.48550/arxiv.2311.11205 · Cited by 2
“Another method employs deep convolutional neural networks for segmenting catheters and guidewires in 2D X-ray fluoroscopic sequences, using previous image contexts for enhanced accuracy and achieving a notable median centerline distance error of 0.2 mm [18].”
MethodInfluentialDFR-Net: A Novel Multi-Task Learning Network for Real-Time Multi-Instrument Segmentation
Zhou, Y.-J., Liu, S.-Q., Xie, X., & Hou, Z. (2021) · ACM International Conference on Multimedia (ACM MM) · doi:10.1145/3474085.3475491 · Cited by 1
“The detection and segmentation of instruments in X-ray images has received widespread attention, from guidewires and catheters [1, 17] to delivery devices and stents [11, 52].”
BackgroundMethodKim, C., Jeong, D., Kim, D., Ryu, J., & Cho, K. (2024) · IEEE Access · doi:10.1109/access.2024.3422135 · Cited by 1
“(1) Only the radiopaque area of the guidewire (guidewire tip) is segmented, whereas in [26], both the guide catheter and entire guidewire were segmented.”
BackgroundMethodInfluentialFrom Pixels to Predictions: Exploring the Role of Artificial Intelligence in Radiology
Aiyappa, M. J. A., & Shetty, B. S. K. (2024) · Biological and medical physics, biomedical engineering · doi:10.1007/978-981-97-5345-1_2 · Cited by 3
Vision Servoing Endovascular Interventional Robot System: Design and Verification
Wang, C., Zhu, J., Li, X., Chen, S., Chen, Z., Huang, Y., Wu, Y., Zhan, M., & Lu, L. (2024) · IEEE International Conference on Cyborg and Bionic Systems (CBS) · doi:10.1109/cbs61689.2024.10860327 · Cited by 1
Single-Source Domain Generalization for Coronary Vessels Segmentation in X-Ray Angiography
Atwany, M., Lashgari, M., Choudhury, R. P., Grau, V., & Banerjee, A. (2025) · Lecture notes in computer science · doi:10.1007/978-3-031-87756-8_1 · Cited by 1
Chabi, N., Manríquez, A. I., Beuing, O., Behme, D., Preim, B., & Saalfeld, S. (2025) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-025-03434-w · Cited by 1
MSLNet and Perceptual Grouping for Guidewire Segmentation and Localization
Barbu, A. (2025) · Sensors · doi:10.3390/s25206426 · Cited by 1
Zhou, X., Liu, Y., Zhang, M., Li, J., Guo, Y., & Yang, G. (2025) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros60139.2025.11246693 · Cited by 1
“With the development of biomedical imaging and surgical robotics, deep convolutional neural networks have found widespread applications in surgical curve detection, such as catheter detection [8], airway reconstruction [9] and vessel enhancement [10]–[12].”
Toward real-time autonomous navigation: transformer-based catheter tip tracking in fluoroscopy
Robertshaw, H. H., Hao, Y., Deng, W., Jackson, B., Sadati, S. M. H., Fischer, N., Vercauteren, T. K., Granados, A., & Booth, T. C. (2026) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-026-03647-7 · Cited by 1
“Current device tracking methods rely on deep networks such as U-Net and instance-segmentation models, aiming to deliver full-catheter masks at ∼ 8 fps with 1 mm tip error without manual setup [12, 13].”
Detection Of Chest Catheters Using Mask R-CNN
Sreedhar, R., Thomas, J., & Raj, E. D. (2021) · International Conference on Smart Generation Computing, Communication and Networking (SMART GENCON) · doi:10.1109/smartgencon51891.2021.9645851 · Cited by 1
Image processing for semantic analysis of the coronary interventions in cardiology
Bacchuwar, K. (2018) · theses.fr (ABES) · doi:10.70675/1415eafbz4a65z46d1zb96bz40ce0d75eb45
“Recently, [Ambrosini et al., 2017] proposed deep convolutional neural network based faster and fully automatic segmentation of guidewire and catheter.”
BackgroundOne-Shot Learning for Function-Specific Region Segmentation in Mouse Brain
Zhang, X., Li, Z., Wang, P., Liao, K. Y., Chou, S., Chang, S., & Liao, J. (2019) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2019.8759226
“For the segmentation model, we follow the UNet model as defined in [17] with 5 down-sampling and up-sampling layers.”
MethodLearning saliently temporal-spatial features for x-ray coronary angiography sequence segmentation
Hao, D., Liu, Y., & Qin, B. (2019) · International Conference on Digital Image Processing · doi:10.1117/12.2539600
Breininger, K., Pfister, M., Kowarschik, M., & Maier, A. (2021) · Informatik aktuell · doi:10.1007/978-3-658-33198-6_10
Development of a 3D visualization system for the cerebral aneurysm coil embolization
Kadota, H., Fujisawa, S., Oono, M., Morigaki, R., Yamamoto, N., Kanematsu, Y., Ishihara, M., & Sisibori, M. (2021) · International Conference on Quality Control by Artificial Vision (QCAV) · doi:10.1117/12.2589084
“I n = {ix,y|ix,y ≥ 0, ix,y ∈ In − In−1} (1) I− n = {ix,y|ix,y ≥ 0, ix,y ∈ In−1 − In} (2) I ′ n = { I n − I − n (t = 1) I ′ n−1 − I + n − I − n (t ≥ 2) (3)”
Image-guided interactive simulation for endovascular gurgery
Trivisonne, R. (2020) · theses.fr (ABES) · doi:10.70675/278880fez43c0z455ez85bfz00a967d77896
SIX-Net: Spatial-Context Information miX-up for Electrode Landmark Detection
Wang, X., Xu, Z., Zhu, H., Yao, Q., Sun, Y., & Zhou, S. K. (2024) · Lecture notes in computer science · doi:10.1007/978-3-031-72378-0_32
FedSSL: Federated Learning with Shape-Sensitive Loss for Catheter and Guidewire Segmentation
Kongtongvattana, C., Huang, B., Nguyen, H. A., Olajide, O., & Nguyen, A. (2024) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio64047.2024.10907455 · Cited by 2
“In X-ray fluoroscopy, fully automated real-time segmentation models [36] leverage deep convolutional networks to achieve high accuracy with minimal annotation.”
Early identification of catheter misplacement and lines on chest x-rays
Vijaykumar, N., Shanmuganathan, S., Alagappan, S., Madhaiyan, V., & Sureshkumar, Y. (2025) · AIP conference proceedings · doi:10.1063/5.0262907
FedPGD: Federated Learning with Projected Gradient Descent for Catheter and Guidewire Segmentation
Kongtongvattana, C., Huang, B., Nguyen, H. A., Olajide, O., & Nguyen, A. (2025) · Lecture notes in networks and systems · doi:10.1007/978-3-031-92011-0_7 · Cited by 1
Wang, J., Zhang, G., Yang, W., Wang, C., & Yang, J. B. (2025) · Applied Sciences · doi:10.3390/app152212247
Fan, Z., Qiao, Y., Li, C., Yang, B., Wei, R., Hong, Z., Chen, Y., & Tu, S. (2025) · IEEE International Conference on Bioinformatics and Biomedicine (BIBM) · doi:10.1109/bibm66473.2025.11356852
“With the emergence of deep learning, data-driven segmentation frameworks such as U-Net and its variants have been widely used for both catheter and guidewire analysis [4], [5], achieving remarkable improvements in accuracy.”
Metadata
- Authors
- Ambrosini, P., Ruijters, D., Niessen, W. J., Moelker, A., & van Walsum, T.
- Affiliations
- Erasmus MC (NL)
- Corresponding author
- Ambrosini, Pierre
- Venue
- Lecture Notes in Computer Science
- Publisher
- Springer International Publishing
- Published
- 2017
- Pages
- 577-585
- ISSN
- 0302-9743 (ISSN-L)
- 1611-3349
- OpenAlex
- W2738072630
- Cited by
- 102
- References
- 20
- Citations by year
- 2026: 6 · 2025: 12 · 2024: 11 · 2023: 6 · 2022: 13 · 2021: 18 · 2020: 14 · 2019: 12 · 2018: 8 · 2017: 2
- FWCI
- 2.86
- Type
- conference paper
- Language
- en
- Open access
- green
- arxiv.org
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Lecture notes in computer science (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- EUR Research Repository (Erasmus University Rotterdam) (submittedVersion)
- RePub (Erasmus University Rotterdam) (submittedVersion, other-oa)
- arXiv (Cornell University)
- Lecture notes in computer science
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Physical Sciences › Engineering › Biomedical Engineering › Medical Imaging and Analysis
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Advanced Neural Network Applications
- Keywords
- X-ray fluoroscopy, real-time segmentation, convolutional neural networks, instrument tracking, interventional radiology, data augmentation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.