Toward robot-assisted vascular microsurgery in the retina
Abstract
Background Experimental protocol in our laboratory routinely requires the precise placement of instruments at, or near, the retina. Although manipulators for placing an instrument within the eye presently exist, none of the designs were satisfactory due to limitations on size, accuracy and operability. To overcome these limitations, we have developed a novel six degree of freedom manipulator designed specifically for retinal microsurgery. Methods The manipulator is parallel in structure and provides submicrometer positioning of an instrument within the constrained environment of the eye. The position of an instrument attached to the manipulator is commanded by the operator using a hand-held trackball. A computer controller interprets the trackball input and moves the manipulator in an intuitive manner according to mathematically constrained modes of operation. Results Over 50 retinal vessels in the live, anesthetized cat have been successfully cannulated for pressure measurement and drug injection using the described manipulator and micropuncture techniques. The targeted vessels ranged in internal diameter from 20 to 130 microns. Conclusion This device has applications in microsurgery where tremor and fatigue limit the performance of an unaided hand and where mechanically constrained manipulators are inappropriate due to size and operative constraints.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
A Platform with Six Degrees of Freedom
Stewart, D. (1965) · Proceedings of the Institution of Mechanical Engineers · doi:10.1243/pime_proc_1965_180_029_02 · Cited by 2,634
A platform with 6 degrees of freedom
Stewart, D. (1966) · Medical Entomology and Zoology · Cited by 190
A teleoperated microsurgical robot and associated virtual environment for eye surgery
Hunter, I. W., Doukoglou, T. D., Lafontaine, S. R., Charette, P. G., Jones, L. A., Sagar, M. A., Mallinson, G. D., & Hunter, P. J. (1993) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.1993.2.4.265 · Cited by 164
Direct Kinematics and Assembly Modes of Parallel Manipulators
Merlet, J. (1992) · The International Journal of Robotics Research · doi:10.1177/027836499201100205 · Cited by 135
A six degree of freedom micromanipulator for ophthalmic surgery
Grace, K. W., Colgate, J. E., Glucksberg, M. R., et al. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.1993.292049 · Cited by 79
Self-citationDirect Measurement of Retinal Microvascular Pressures in the Live, Anesthetized Cat
Glucksberg, M. R., & Dunn, R. (1993) · Microvascular Research · doi:10.1006/mvre.1993.1015 · Cited by 78
Self-citationThe influence of elevated intraocular pressure on vascular pressures in the cat retina.
Attariwala, R., Giebs, C. P., & Glucksberg, M. R. (1994) · PubMed · Cited by 43
Self-citationIn vivo cannulation of retinal vessels
Allf, B. E., & de Juan, E. (1987) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/bf02175453 · Cited by 33
In vivo micropuncture of retinal vessels
Glucksberg, M. R., Dunn, R., & Giebs, C. P. (1993) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/bf00919649 · Cited by 32
Self-citationPournaras, C. J., Shonat, R. D., Munoz, J.-L., & Petrig, B. L. (1991) · Experimental Eye Research · doi:10.1016/0014-4835(91)90107-p · Cited by 29
Research works printed but not linked: 2
- Charles S (1994) Dexterity enhancement for surgery. Proc First Int'l Symp Med Robotics Comput Assist Surg 2:145–160
- Grace KW (1995) Kinematic design of an ophthalmic surgery robot and feature extracting bilateral manipulation. Ph D thesis, Northwestern University, Evanston, Ill
Cited by
Medical robotics in computer-integrated surgery
Taylor, R. H., & Stoianovici, D. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817058 · Cited by 997
A Steady-Hand Robotic System for Microsurgical Augmentation
Taylor, R., Jensen, P., Whitcomb, L., Barnes, A., Kumar, R., Stoianovici, D., Gupta, P., Wang, Z., Dejuan, E., & Kavoussi, L. (1999) · The International Journal of Robotics Research · doi:10.1177/02783649922067807 · Cited by 528
Self-citationMedical Robotics and Computer-Integrated Surgery
Taylor, R. H., Menciassi, A., Fichtinger, G., Fiorini, P., & Dario, P. (2016) · Springer Handbooks · doi:10.1007/978-3-319-32552-1_63 · Cited by 325
Micron: An Actively Stabilized Handheld Tool for Microsurgery
MacLachlan, R. A., Becker, B. C., Tabares, J. C., Podnar, G. W., Lobes, L. A., & Riviere, C. N. (2012) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2169634 · Cited by 270
Toward active tremor canceling in handheld microsurgical instruments
Riviere, C. N., Ang, W. T., & Khosla, P. K. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817506 · Cited by 245
Metadata
- Authors
- Jensen, P. S., Grace, K. W., Attariwala, R., Colgate, J. E., & Glucksberg, M. R.
- Affiliations
- Northwestern University (US)
- Corresponding author
- Glucksberg, Matthew R.
- Venue
- Graefe's Archive for Clinical and Experimental Ophthalmology
- Published
- 1997-11
- Volume
- 235
- Issue
- 11
- Pages
- 696-701
- ISSN
- 0721-832X (ISSN-L)
- 1435-702X
- OpenAlex
- W2066140684
- Cited by
- 90
- References
- 13
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 2 · 2023: 2 · 2022: 5 · 2021: 4 · 2020: 4 · 2019: 4 · 2018: 1 · 2017: 6 · 2016: 5 · 2015: 6 · 2014: 5 · 2013: 5 · 2012: 9
- FWCI
- 1.20
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Graefe s Archive for Clinical and Experimental Ophthalmology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01ey009714-07)
- National Eye Institute (EY-09714)
- Topics
- Health Sciences › Medicine › Ophthalmology › Retinal and Macular Surgery
- Physical Sciences › Engineering › Control and Systems Engineering › Robotic Mechanisms and Dynamics
- Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
- Keywords
- robotic surgery, retinal microsurgery, parallel manipulators, 6-DOF manipulator, retinal vasculature, micropuncture, drug injection
- MeSH terms
- Animals, Cats, Equipment Design, Microsurgery, Retinal Vessels, Robotics, Therapy, Computer-Assisted
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Toward robot-assisted vascular microsurgery in the retina. https://app.cochat.ai/papers/10.1007/bf01880668
- The paper
- Jensen, P. S., Grace, K. W., Attariwala, R., Colgate, J. E., & Glucksberg, M. R. (1997). Toward robot-assisted vascular microsurgery in the retina. Graefe's Archive for Clinical and Experimental Ophthalmology. https://doi.org/10.1007/bf01880668
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.