Characterization of the oscillometric method for measuring indirect blood pressure
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Among BPMDs using fixed-ratio coefficients, there is systematic bias towards greater underestimation of systolic BP as systolic BP increases, because the optimal fixed-ratio coefficient for accurate systolic BP estimation becomes progressively lower as systolic BP increases (e.g., the optimal fixed-ratio approximates 0.57 at 100 mmHg but this falls to 0.45 at 190 mmHg) [12].”
From Automated 'oscillometric' blood pressure measuring devices: how they work and what they measure (2022) · cites this paper as [12]
In the citing paper
“However, the range of optimal coefficients for accurate systolic and diastolic BP measurements varies greatly between devices [12, 45, 50, 54].”
From Automated 'oscillometric' blood pressure measuring devices: how they work and what they measure (2022) · cites this paper as [12]
In the citing paper
“specifically designed to provide BP values equivalent to the systolic and diastolic BP values measured with a mercury sphygmomanometer [12].”
From Automated 'oscillometric' blood pressure measuring devices: how they work and what they measure (2022) · cites this paper as [12]
Citations
Cites
Noninvasive automatic determination of mean arterial pressure
Ramsey, M. (1979) · Medical and Biological Engineering and Computing · doi:10.1007/bf02440948 · Cited by 287
PHYSIOLOGIC RELATIONSHIPS BETWEEN INTRATHORACIC, INTRASPINAL AND ARTERIAL PRESSURES
HAMILTON, W. F. (1936) · Journal of the American Medical Association · doi:10.1001/jama.1936.02770370017005 · Cited by 277
Recommendations for Human Blood Pressure Determinations by Sphygmomanometers
BORDLEY, J., CONNOR, C. A. R., HAMILTON, W. F., KERR, W. J., & WIGGERS, C. J. (1951) · Circulation · doi:10.1161/01.cir.4.4.503 · Cited by 262
Mauck, G. W., Smith, C. R., Geddes, L. A., & Bourland, J. D. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138195 · Cited by 222
Self-citationIndirect Measurement of Mean Blood Pressure in the Anesthetized Patient
Yelderman, M., & Ream, A. K. (1979) · Anesthesiology · doi:10.1097/00000542-197903000-00022 · Cited by 142
The error in indirect blood pressure measurement with the incorrect size of cuff
Geddes, L. A., & Whistler, S. J. (1978) · American Heart Journal · doi:10.1016/0002-8703(78)90119-9 · Cited by 117
Self-citation(1969) · PubMed · Cited by 96
Self-citationIndirect Mean Blood Pressure in the Anesthetized Pony
Geddes, L. A., Chaffee, V., Whistler, S. J., BOURLAND, J. D., & Tacker, W. A. (1977) · American Journal of Veterinary Research · doi:10.2460/ajvr.1977.38.12.2055 · Cited by 45
Self-citationIndirect Measurement of Mean Blood Pressure in the Normotensive and Hypotensive Horse
Latshaw, H. S., FESSLER, J. F., Whistler, S. J., & Geddes, L. A. (1979) · Equine Veterinary Journal · doi:10.1111/j.2042-3306.1979.tb01340.x · Cited by 44
Self-citationGraphic recording of the korotkoff sounds
Geddes, L. A., Spencer, W. A., & HOFF, H. E. (1959) · American Heart Journal · doi:10.1016/0002-8703(59)90317-5 · Cited by 26
Self-citation
Research works printed but not linked: 2
- Geddes, L.A., W. Combs, W. Denton, S.J. Whistler, and J.D. Bourland. Indirect mean blood pressure in the dog.Am. J. Physiol. (Heart & Circulation) 7:H663-H666, 1980.
- Steele, J.M. Comparison of simultaneous indirect (auscultatory) and direct (intra-arterial) measurements of arterial pressure in man.J. Mt. Sinai Hosp. 8:1042–1050, 1941.
Cited by
Items 301–339 of 339
An Optimized Algorithm to Measure Arterial Blood Pressure
Zhong, M. L., Chen, M., & Wang, Q. (2013) · Advanced materials research · doi:10.4028/www.scientific.net/amr.760-762.2081
The non-incursion blood pressure algorithm under arrhythmia
Zhenye, Y., Dayi, W., Jiexin, H., & Jiming, Y. (2011) · International Conference on Biomedical Engineering and Informatics (BMEI) · doi:10.1109/bmei.2011.6098367
Lee, P.-J., Lee, Y.-J., Kim, K., Lee, J., Lim, M. K., & Lee, J. (2012) · The Transactions of The Korean Institute of Electrical Engineers · doi:10.5370/kiee.2012.61.6.885
Measuring Blood Pressure Using Oscillation Signal from an Automatic Sphygmomanometer
Kim, D., & Kim, Y. (2012) · The Transactions of The Korean Institute of Electrical Engineers · doi:10.5370/kiee.2012.61.11.1720
Desenvolvimento de um Sistema de Verificação da Pressão Arterial Através do Método Oscilométrico
Pereira, L. F. (2006) · Americanae (AECID Library)
"Riva-Rocci & Poli-Mi": a Signal Base Management System for non-invasive BP measuring events
Pinciroli, F., Manni, E., Portoni, L., & Combi, C. (2002) · Computers in cardiology · doi:10.1109/cic.1994.470153
Nostell, K. E. A., & Jones, B. E. (2012)
Zhong, L. (2005) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/5568
An evaluation of Arterial Stiffness Index in Relation to the State of the Cardiovascular System
Havlík, J., David, J., Dvořák, J., & Lhotská, L. (2015) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-319-19387-8_238
Dual-cuff system for improved determination of blood pressures and hemodynamics
Jílek, J. O., & Štork, M. (2010) · International Conference on Systems
Model Investigation of Pseudo-Hypertension in Oscillometry
Drzewiecki, G. M. (2015) · CRC Press eBooks · doi:10.1201/b18690-5
Estimation of Central Aortic Blood Pressure using a Noninvasive Automatic Blood Pressure Monitor
Shih, Y., Sun, Y.-J., Chen, C., Cheng, H., & Hu, W.-C. (2009) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-92841-6_122
Minimally invasive monitoring in patients under general anesthesia
Vos, J. J. (2015) · University of Groningen research database (University of Groningen / Centre for Information Technology)
Abderahman, H. N. (2016) · uO Research (University of Ottawa) · doi:10.20381/ruor-272
Robust Estimation of Mean Arterial Pressure in Atrial Fibrillation Using Oscillometry
Tannous, M. (2014) · uO Research (University of Ottawa) · doi:10.20381/ruor-5036
IMPROVED AUTOMATIC CUFF BLOOD PRESSURE MEASUREMENT
Liu, J. (2016) · Michigan State University Libraries · doi:10.25335/m5bf45
The effect of wrist cuff width on oscillometric blood pressure waveforms
Jílek, J. O., & Štork, M. (2008) · Digital Library (University of West Bohemia)
Statistical approach Based on Deep Neural Networks for Oscillometric Blood Pressure EstimationPreprint
Lee, S., & Chang, J. (2018) · Preprints.org · doi:10.20944/preprints201805.0276.v1
Saugel, B., Scheeren, T., & Teboul, J. (2019) · Lessons from the ICU · doi:10.1007/978-3-319-69269-2_21
An Oscillometry-Based Approach for Measuring Blood Flow of Brachial Arteries
Liu, S.-H., Wang, J. J., & Huang, K.-S. (2009) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-92841-6_118
Schmidt, V. G. (2015) · Elektronische Hochschulschriften der LMU München (Ludwig-Maximilians-Universität München) · doi:10.5282/edoc.17876
Simulation of Estimating the Blood Pressure Using an Arterial Pressure-Volume Model
Yoon, S.-H., Jung, J.-H., Jeon, A.-Y., Kim, I., Kang, S.-C., Kim, J.-H., Kim, C.-H., Ye, S.-Y., & Jeon, G.-R. (2007) · International Conference on Computer Sciences and Convergence Information Technology · doi:10.1109/iccit.2007.412
Innovative Mobile Device for Human Health Monitoring
Михайлович, С. В., Petrova, I. Y., & Sokol’skii, M. V. (2021) · Lecture notes in networks and systems · doi:10.1007/978-3-030-69221-6_1
Fatima, M., Yaqoob, M., & Qayyum, Z. (2021) · Systematic Reviews in Pharmacy · doi:10.31838/srp.2021.4.33
Duy, V. C., Vu, A., & Nguyen, M. T. (2022) · Smart Systems and Devices · doi:10.51316/jst.160.ssad.2022.32.3.5 · Cited by 1
Wearable Smart Device That Can Monitor Multiple Vital Parameters
(2023) · Journal of Population Therapeutics and Clinical Pharmacology · doi:10.47750/jptcp.2023.30.15.039
Devices based on oscillometric signal
Bolić, M. (2023) · Elsevier eBooks · doi:10.1016/b978-0-12-820947-9.00009-x
Implementation of a Video Game Controlled by Pressing the Upper Arm Using PPG Sensor
Yoshida, K., Mizuno, G., Kurata, N., & Murao, K. (2023) · Lecture notes in computer science · doi:10.1007/978-3-031-48348-6_14
Inspection and Testing of Noninvasive Blood Pressure Measuring Devices
Lacković, I. (2023) · Series in biomedical engineering · doi:10.1007/978-3-031-43444-0_8
Celler, B. G., Yong, A. S. C., Rubenis, I., Butlin, M., Argha, A., Rehan, R., & Avolio, A. P. (2024) · Journal of Hypertension · doi:10.1097/hjh.0000000000003698 · Cited by 1
Jasim, M. S. M. (2024) · International Journal of Advanced Academic Studies · doi:10.33545/27068919.2024.v6.i6a.1194
Pereira, J. M. D., Ribeiro, G., & Postolache, O. A. (2025) · Applied Sciences · doi:10.3390/app15063198
Meßprinzip, Validierung und Grenzen der Oszillometrischen Blutdruckmessung
Felger, M. (1993) · Konzepte in der Humanpharmakologi · doi:10.1007/978-3-642-50229-3_26
mmWave-Based Contactless BP Monitoring With Physio-Model-Guided Deep Learning
Cao, Y., Zhang, S., Li, F. X., Chen, Z., & Luo, J. (2025) · IEEE Transactions on Mobile Computing · doi:10.1109/tmc.2025.3647930
Engineering Deep Dive of the VascuMAP Development
Campbell, J. S. (2025) · IEEE Pulse · doi:10.1109/mpuls.2025.3618448
A wearable fiber-optoacoustic interface for continuous deep-tissue hemodynamics in MRI environments
Hu, Z., Ma, M., Wu, C., Bai, X., Li, W., Cheng, Z., Mai, C., Liang, Y., Jin, L., & Guan, B.-O. (2026) · Photoacoustics · doi:10.1016/j.pacs.2026.100830
Al-Ayyad, M. S., Moh’d, B. A.-H., Shamsan, M. H., Ahmad, M. A.-S., Al-Takrouri, M., & Owida, H. A. (2026) · HardwareX · doi:10.1016/j.ohx.2026.e00843
Development of Blood Pressure Measurement Method Using ANFIS
Chun, M.-G., Kwon, S.-Y., & Lee, D.-J. (2006) · Journal of Korean institute of intelligent systems · doi:10.5391/jkiis.2006.16.4.493
Metadata
- Authors
- Geddes, L. A., Voelz, M., Combs, C., Reiner, D., & Babbs, C. F.
- Affiliations
- Purdue University West Lafayette (US)
- Venue
- Annals of Biomedical Engineering
- Published
- 1982-11
- Volume
- 10
- Issue
- 6
- Pages
- 271-280
- ISSN
- 0090-6964 (ISSN-L)
- 1573-9686
- OpenAlex
- W2003899531
- Semantic Scholar
- 11130bb58509d11506466b456e8e31460a7b40c6
- Cited by
- 340
- References
- 11
- Citations by year
- 2026: 4 · 2025: 9 · 2024: 12 · 2023: 13 · 2022: 14 · 2021: 17 · 2020: 11 · 2019: 22 · 2018: 16 · 2017: 11 · 2016: 15 · 2015: 20 · 2014: 12 · 2013: 8 · 2012: 18
- FWCI
- 0.55
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Annals of Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Purdue e-Pubs (Purdue University System) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Keywords
- oscillometric blood pressure measurement, systolic blood pressure, diastolic blood pressure, cuff deflation, auscultatory method
- MeSH terms
- Adolescent, Adult, Animals, Biomedical Engineering, Blood Pressure Determination, Diastole, Dogs, Evaluation Studies as Topic, Humans, Middle Aged, Oscillometry, Systole
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.