Attenuation of pathological tremors by functional electrical stimulation II: Clinical evaluation
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In this study we evaluated a technique for tremor suppression with functional electrical stimulation (FES), the technical details of which were described in the previous paper. Three groups of patients were investigated: those with essential tremor, parkinsonian tremor, and cerebellar tremor associated with multiple sclerosis. In each group, tremor was attenuated by significant amounts (essential tremor: 73%; parkinsonian tremor: 62%; cerebellar tremor: 38%). These attenuations were in good accord with predictions based on the dynamic analyses and filter designs derived in the previous paper. With filters "tuned" to the lower mean tremor frequency encountered in the cerebellar patients, more attenuation was possible in this group as well. We identified some practical limitations in the clinical application of the technique in its present form. The most important was that in daily use, only one antagonist pair of muscles can realistically be controlled. At first sight, this restricts the usefulness of the system to patients with single-joint tremors. However, the concomitant use of mechanical orthoses may broaden the scope of application.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A number of works show how adequate inertial (mass) loading of the tremulous limb reduces the amplitude of most types of tremor [18,19]”
From A neuroprosthesis for tremor management through the control of muscle co-contraction (2013) · cites this paper as [18]
In the citing paper
“Although tremor in one patient did not decreased, the device achieved an average suppression of 58.1 ± 20.5% (in a range between 91 and 10%) in the rest of the patients.”
From A Review on Wearable Technologies for Tremor Suppression (2021) · cites this paper as [64]
Citations
Cites
(1984) · Palgrave Macmillan UK eBooks · doi:10.1007/978-1-349-06757-2 · Cited by 213
Lee, R. G., & Stein, R. B. (1981) · Annals of Neurology · doi:10.1002/ana.410100606 · Cited by 205
Attenuation of pathological tremors by functional electrical stimulation I: Method
Prochazka, A., Elek, J., & Javidan, M. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368521 · Cited by 150 · cited 7×
“I N T R O D U C T I O N In the prev ious p a p e r (7) we descr ibed a new m e t h o d for select ively a t t enua t i ng t r e m o r by using c losed- loop func t iona l e lectr ical s t imu la t ion (FES) to ac t iva te the t r emorogen ic muscles ou t -o f -phase .”
BackgroundMethodSelf-citationOrigins of normal and pathological tremor
Marsden, C. D. (1984) · Movement Disorders: Tremor · doi:10.1007/978-1-349-06757-2_4 · Cited by 142
AN INVESTIGATION INTO THE VALUE OF TREATING INTENTION TREMOR BY WEIGHTING THE AFFECTED LIMB
HEWER, R. L., COOPER, R., & MORGAN, M. H. (1972) · Brain · doi:10.1093/brain/95.3.579 · Cited by 112 · cited 1×
“The po ten t i a l advan t age o f such a system is tha t it does not rely on mechanical loading o f the ext remity (2), nor on external ly powered e l ec t romechan ica l devices (6).”
BackgroundTHE ROLE OF REFLEXES IN THE RESTING TREMOR OF PARKINSON'S DISEASE
RACK, P. M. H., & ROSS, H. F. (1986) · Brain · doi:10.1093/brain/109.1.115 · Cited by 89
Freund, H., Hefter, H., Hömberg, V., & Reiners, K. (1984) · Palgrave Macmillan UK eBooks · doi:10.1007/978-1-349-06757-2_12 · Cited by 11
Research works printed but not linked: 4
- Javidan, M.; Elek, J.; Prochazka, A. Tremor reduction by functional electrical stimulation. Neurology 40:369; 1990.
- Morrice, B.L.; Lee, R.G.; Becker, W.J.; White, D.G.; Hoffer, J.A. Viscous loading improves manual tracking accuracy in humans with cerebellar incoordination. Soc. Neurosci. Abstracts 13:1700; 1987.
- Prochazka, A.; Davis, L.; Gauthier, M. New intramuscular electrodes and microprocessor control of electrical stimulation to improve hemiparetic gait. Soc. Neurosci. Abstracts. 17:1468; 1991.
- Stein, R.B.; Prochazka, A.; Popovic, D.; Edamura, M.; Llewellyn, M.; Davis, L.A. Technology transfer and development for walking using functional electrical stimulation. In: D. Popovic, ed. Advances in external control of human extremities X. Belgrade: Yugoslav Committee for Electronics and Automation; 1990: pp. 161–176.
Cited by
Prochazka, A., Gauthier, M., Wieler, M., & Kenwell, Z. (1997) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(97)90426-3 · Cited by 250
Attenuation of pathological tremors by functional electrical stimulation I: Method
Prochazka, A., Elek, J., & Javidan, M. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368521 · Cited by 150
Self-citationElectrical stimulation for the suppression of pathological tremor
Popović Maneski, L., Jorgovanović, N., Ilić, V., Došen, S., Keller, T., Popović, M. B., & Popović, D. B. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0803-6 · Cited by 129
“The first FES system that was designed to suppress tremor was proposed 20 years ago [6, 15].”
BackgroundOnline tremor suppression using electromyography and low-level electrical stimulation
Dosen, S., Muceli, S., Dideriksen, J. L., Romero, J. P., Rocon, E., Pons, J., & Farina, D. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2328296 · Cited by 120
“As in the majority of previous tremor suppression studies based on FES [15], [16], [19] the stimulation was delivered out of phase with the estimated tremorogenic activity.”
BackgroundResultComparison of natural and artificial control of movement
Procházka, A. (1993) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.242403 · Cited by 109
Estimation of Upper-Limb Orientation Based on Accelerometer and Gyroscope Measurements
Hyde, R. A., Ketteringham, L. P., Neild, S. A., & Jones, R. J. S. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.912647 · Cited by 98
“For example, in the FES research to reduce tremor reported in [4], lower arm movement was mechanically constrained to horizontal pivoting, and the pivot angle was measured using a low-noise optical transducer.”
BackgroundTremor suppression through impedance control
Pledgie, S., Barner, K. E., Agrawal, S. K., & Rahman, T. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.830949 · Cited by 85
A neuroprosthesis for tremor management through the control of muscle co-contraction
Gallego, J. Á., Rocon, E., Belda-Lois, J. M., & Pons, J. L. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-36 · Cited by 81
“Furthermore, voluntary [24,25] or artificially elicited [26] muscle contractions affect the severity of the tremor, by generating forces on the musculoskeletal system.”
BackgroundMethodElectrical stimulation of afferent pathways for the suppression of pathological tremor
Dideriksen, J. L., Laine, C. M., Dosen, S., Muceli, S., Rocon, E., Pons, J. L., Benito-Leon, J., & Farina, D. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00178 · Cited by 67
“…suggested the use of external devices to suppress tremor by mechanical loading (Pledgie et al., 2000; Rocon et al., 2007) or electrical stimulation (Javidan et al., 1992; Prochazka et al., 1992; Gillard et al., 1999; Popović Maneski et al., 2011; Gallego et al., 2013; Bó et al., 2014; Dosen et…”
BackgroundPeripheral electrical stimulation to reduce pathological tremor: a review
Pascual-Valdunciel, A., Hoo, G. W., Avrillon, S., Barroso, F. O., Goldman, J. G., Hernandez-Pavon, J. C., & Pons, J. L. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00811-9 · Cited by 66
“Four papers reported additional results on other tremor conditions, including cerebellar ataxias [17], patients with scans without evidence of dopaminergic deficits (SWEEDs) [35], peripheral neuropathy [18], and multiple sclerosis [40].”
BackgroundResultInfluentialMedical Devices for Tremor Suppression: Current Status and Future Directions
Mo, J., & Priefer, R. (2021) · Biosensors · doi:10.3390/bios11040099 · Cited by 78
“The recognized limitations of these early works included the potentially unreliable placement of surface electrodes, which could lead to insufficient tremor suppression [74,75].”
BackgroundA Review on Wearable Technologies for Tremor Suppression
Lora-Millan, J. S., Delgado-Oleas, G., Benito-León, J., & Rocon, E. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.700600 · Cited by 62
A Soft Exoskeleton for Tremor Suppression Equipped with Flexible Semiactive Actuator
Zahedi, A., Zhang, B., Yi, A., & Zhang, D. (2021) · Soft Robotics · doi:10.1089/soro.2019.0194 · Cited by 57
“5,19,23 In addition, it is a big problem for closed-loop control of FES in suppressing tremor in real time.”
Optimal digital filtering for tremor suppression
Gonzalez, J. G., Heredia, E. A., Rahman, T., Barner, K. E., & Arce, G. R. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.841338 · Cited by 56
Non-pharmacological and non-surgical interventions for tremor: A systematic review
O’Connor, R. J., & Kini, M. U. (2011) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2010.12.016 · Cited by 55
“The first study recruited patients with tremor at the wrist due to multiple sclerosis, Parkinson’s disease and essential tremor [31].”
BackgroundJitkritsadakul, O., Thanawattano, C., Anan, C., & Bhidayasiri, R. (2017) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2017.08.3246 · Cited by 51
Gillard, D. M., Cameron, T., Prochazka, A., & Gauthier, M. J. A. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.788474 · Cited by 61
EMG-Based Characterization of Pathological Tremor Using the Iterated Hilbert Transform
Dideriksen, J. L., Gianfelici, F., Maneski, L. Z. P., & Farina, D. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2163069 · Cited by 42
“on inertial loading [5] or on functional electrical stimulation (FES) [6], [7].”
BackgroundJitkritsadakul, O., Thanawattano, C., Anan, C., & Bhidayasiri, R. (2015) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2015.08.1527 · Cited by 38
Repetitive Control of Electrical Stimulation for Tremor Suppression
Copur, E. H., Freeman, C. T., Chu, B., & Laila, D. S. (2019) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2017.2771327 · Cited by 38
“In [14], conventional high-pass and bandpass filters were applied in closed-loop to suppress tremor at the wrist or elbow”
MethodA wearable elbow exoskeleton for tremor suppression equipped with rotational semi-active actuator
Zahedi, A., Wang, Y., Martínez-Hernández, U., & Zhang, D. (2021) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2021.107674 · Cited by 43
Tremor-Suppression Orthoses for the Upper Limb: Current Developments and Future Challenges
Nguyen, S. H., & Luu, T. P. (2021) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2021.622535 · Cited by 40
“While Javidan et al. (1992) showed a relatively narrow frequency band of (5–8 Hz) for ET tremor, Cooper and Rodnitzky (2000) and Elble (2000) reported ET tremor frequency band at (4–12 Hz) and (3–11 Hz), respectively.”
BackgroundA Model of the Surface Electromyogram in Pathological Tremor
Dideriksen, J. L., Enoka, R. M., & Farina, D. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2118756 · Cited by 35
“Current methods for the treatment of tremor include medication, deep brain stimulation [5], functional electrical stimulation (FES) [6], [7], and orthotic exoskeletons [8].”
MethodZeuner, K. E., & Deuschl, G. (2012) · Current Opinion in Neurology · doi:10.1097/wco.0b013e3283550c7e · Cited by 34
A Wearable System for Attenuating Essential Tremor Based on Peripheral Nerve Stimulation
Kim, J., Wichmann, T., Inan, O. T., & Deweerth, S. P. (2020) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2020.2985058 · Cited by 33
“Although muscle stimulation from [17], [18], [24], [25] reported a promising tremor reduction ratio of between 50% and 85%, the threshold amplitude of the stimulation to generate muscle twitches are typically higher than the sensory threshold.”
BackgroundNon-invasive electrical stimulation of peripheral nerves for the management of tremor
Valdunciel, A. P., Rajagopal, A., Pons, J. L., & Delp, S. L. (2022) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2022.120195 · Cited by 38
Sensory control of normal movement and of movement aided by neural prostheses
Procházka, A. (2015) · Journal of Anatomy · doi:10.1111/joa.12311 · Cited by 43
“The only closed-loop FES devices to have been tested in participants going about their daily lives were a foot-drop stimulator (Prochazka & Wiles, 1983) and a tremor-suppressing system (Javidan et al. 1992; Prochazka et al. 1992).”
BackgroundRepetitive control of functional electrical stimulation for induced tremor suppression
Freeman, C. T., Sampson, P., Burridge, J. H., & Hughes, A.-M. (2015) · Mechatronics · doi:10.1016/j.mechatronics.2015.10.008 · Cited by 31
Zhang, Z., Chu, B., Liu, Y., Li, Z., & Owens, D. H. (2022) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2022.3150301 · Cited by 37
“high-pass filter (PI-HPF) based algorithm [17], respectively.”
MethodSensory electrical stimulation for suppression of postural tremor in patients with essential tremor
Heo, J.-H., Kim, J.-W., Kwon, Y., Lee, S.-K., Eom, G.-M., Kwon, D.-Y., Lee, C.-N., Park, K.-W., & Manto, M. (2015) · Bio-Medical Materials and Engineering · doi:10.3233/bme-151372 · Cited by 30
Adaptive band-pass filter (ABPF) for tremor extraction from inertial sensor data
Popović, L. Z., Šekara, T. B., & Popović, M. B. (2010) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2010.03.018 · Cited by 29
“[10] M.”
Hao, M.-Z., Xu, S.-Q., Hu, Z.-X., Xu, F.-L., Niu, C.-X. M., Xiao, Q., & Lan, N. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0286-2 · Cited by 29
Biomechanical loading as an alternative treatment for tremor: a review of two approaches
Rocon, E., Gallego, J. Á., Belda-Lois, J. M., Benito-León, J., & Pons, J. L. (2012) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.107 · Cited by 26
Peripherical Electrical Stimulation for Parkinsonian Tremor: A Systematic Review
Meng, L., Jin, M., Zhu, X., & Ming, D. (2022) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2022.795454 · Cited by 29
Biomechanical Loading as an Alternative Treatment for Tremor: A Review of Two Approaches
Rocon, E., Gallego, J. A., Belda-Lois, J., Benito-León, J., & Pons, J. L. (2012) · Tremor and Other Hyperkinetic Movements · doi:10.7916/d82z147g · Cited by 37
Prabhavathi, K., & Patil, S. S. (2021) · Series in bioengineering · doi:10.1007/978-981-16-3056-9_9 · Cited by 25
Evaluation of a controlled-energy-dissipation orthosis for tremor suppression
Arnold, A. S., Rosen, M. J., & Aisen, M. L. (1993) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(05)80001-x · Cited by 24
Physiological Tremor Filtering Without Phase Distortion for Robotic Microsurgery
Adhikari, K., Tatinati, S., Veluvolu, K. C., & Chambers, J. A. (2020) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2020.3041427 · Cited by 22
“Hence, initially in human-machine interface, linear-phase lowpass or bandstop filters were applied directly to the whole motion to suppress the tremor [23], [24].”
RBF-Based Technique for Statistical Demodulation of Pathological Tremor
Gianfelici, F. (2013) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2013.2263288 · Cited by 19
Modeling and experimental study of a hand tremor suppression system
Abbasi, M., & Afsharfard, A. (2018) · Mechanism and Machine Theory · doi:10.1016/j.mechmachtheory.2018.04.009 · Cited by 18
“Old” and emerging Therapies of Human Tremor
Grimaldi, G., & Manto, M. U. (2010) · Clinical Medicine Insights Therapeutics · doi:10.4137/cmt.s2999 · Cited by 18
Frequency domain-based models of skeletal muscle
Baratta, R. V., Solomonow, M., & Zhou, B. (1998) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(97)00024-2 · Cited by 18
Medical and Surgical Treatment of Tremors
Schneider, S. A., & Deuschl, G. (2014) · Neurologic Clinics · doi:10.1016/j.ncl.2014.09.005 · Cited by 18
Lambrecht, S., Gallego, J. A., Rocon, E., & Pons, J. L. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00221 · Cited by 16
“ORIGINAL RESEARCH ARTICLE published: 24 July 2014 doi: 10.3389/fnins.2014.00221 Automatic real-time monitoring and assessment of tremor parameters in the upper limb from orientation data”
BackgroundMethodInfluentialZhang, Z., Chu, B., Liu, Y., Ren, H., Li, Z., & Owens, D. H. (2021) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2021.3111107 · Cited by 18
“The filter based controller was first developed in [12], [17] and the suppression performance of wrist and elbow joint tremor was tested by three different types of patients: the amplitude attenuation of 75% at 3.”
BackgroundMethodNon-invasive Central and Peripheral Stimulation: New Hope for Essential Tremor?
Chalah, M. A., Lefaucheur, J., & Ayache, S. S. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00440 · Cited by 17
Tremor Suppression Using Functional Electrical Stimulation
Habibollahi, Z., Zhou, Y., Jenkins, M. E., Garland, S. J., Friedman, E., Naish, M. D., & Trejos, A. L. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3453222 · Cited by 17
“FES contracts the flexor and extensor muscles simultaneously (co-contraction method) [11], [13], or in an alternating way to counteract tremor (out-of-phase) [8], [9], [10], [12], [14].”
BackgroundWearable Peripheral Electrical Stimulation Devices for the Reduction of Essential Tremor: A Review
Karamesinis, A. D., Sillitoe, R. V., & Kouzani, A. Z. (2021) · IEEE Access · doi:10.1109/access.2021.3084819 · Cited by 14
“amounts of hardware are required, reducing the likelihood of having a comfortable wearable device [65], [66].”
BackgroundSUPPRESSION OF ACTION TREMOR BY SENSORY ELECTRICAL STIMULATION IN PATIENTS WITH ESSENTIAL TREMOR
HEO, J.-H., KWON, Y., JEON, H.-M., KWON, D.-Y., LEE, C.-N., PARK, K.-W., MANTO, M., KIM, J.-W., & EOM, G.-M. (2016) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519416400261 · Cited by 12
Kim, J., Wichmann, T., Inan, O. T., & DeWeerth, S. P. (2022) · Journal of Personalized Medicine · doi:10.3390/jpm12010076 · Cited by 16
Multimodal Tremor Suppression of the Wrist Using FES and Electric Motors–A Simulation Study
Habibollahi, Z., Zhou, Y., Jenkins, M. E., Garland, S. J., Naish, M. D., & Trejos, A. L. (2023) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2023.3316607 · Cited by 11
Phokaewvarangkul, O., Vateekul, P., Wichakam, I., Anan, C., & Bhidayasiri, R. (2021) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2021.727654 · Cited by 12
System identification for FES-based tremor suppression
Çopur, E. H., Freeman, C. T., Chu, B., & Laila, D. S. (2015) · European Journal of Control · doi:10.1016/j.ejcon.2015.12.003 · Cited by 10
“Closed-loop tests using the 40 same model are reported in [34] and show some suppression of tremor when employed with MS patients.”
BackgroundMethodInfluentialRobust higher order repetitive control applied to human tremor suppression
Verstappen, R. J. L. M., Freeman, C. T., Rogers, E., Sampson, T., & Burridge, J. H. (2012) · The proceedings of the IEEE Conference on Control Applications/The proceedings of the ... IEEE Conference on Control Applications · doi:10.1109/isic.2012.6398283 · Cited by 10
Arruda, B. S., Reis, C., Sermon, J. J., Pogosyan, A. H., Brown, P., & Cagnan, H. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00973-6 · Cited by 10
Inertial-based control system concepts for the treatment of movement disorders
Cagnan, H., Brown, P., Bourget, D., & Denison, T. (2015) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2015.7180863 · Cited by 8
“Prochazka and Javidan piloted such a system and demonstrated that tremor can be significantly suppressed in three patient groups (ET, PD and multiple sclerosis) by applying out of phase stimulation to the tremorgenic muscle groups [14].”
Grimaldi, G., Fernandez, A., & Manto, M. U. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-100 · Cited by 5
“It has been proposed that surface muscular functional electrical stimulation (FES) represents an alternative approach to drugs or surgery to reduce neurological tremor [13,14].”
BackgroundLee, S. K., Kim, J. W., Kwon, Y., Lee, Y. J., Lee, J. H., Eom, G., Kwon, D., Lee, C. N., Seo, Y.-W., Kim, M. K., et al. (2013) · Journal of Biomedical Engineering Research · doi:10.9718/jber.2013.34.3.129 · Cited by 5
“FES (functional electrical stimulation)를 이용한 진전 억 제 방법을 제안하였다[12-14].”
Optimization of multi-pad surface electrode: Selective stimulation of wrist
Popović‐Maneski, L., Malešević, N., & Popović, M. B. (2009) · IEEE EUROCON - International Conference on Computer as a Tool (EUROCON) · doi:10.1109/eurcon.2009.5167619 · Cited by 5
Popović‐Maneski, L., & Popović, M. B. (2008) · Symposium on Neural Network Applications in Electrical Engineering · doi:10.1109/neurel.2008.4685591 · Cited by 5
“Most of the people suffering from this motor disorder will not accept surgical procedure, and would rather have more benefit from a surface contact device such as FES based neural prostheses (NP).”
BackgroundFES based tremor suppression using repetitive control
Copur, E. H., Freeman, C., Chu, B., & Laila, D. S. (2015) · 2015 54th IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.2015.7403166 · Cited by 4
“In [4] conventional filters have been applied in closedloop to suppress tremor at the wrist or elbow joint.”
MethodTunable Stiffness Glove for Tremor Suppression Based on 3D Printed Structured Fabrics
Chen, Y., Li, J., Yang, X., & Wang, Y. (2024) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros58592.2024.10801707 · Cited by 3
“According to previous research, a significant drawback of traditional invasive treatments like functional electrical stimulation (FES) is the potential for rapid muscle fatigue [24], [25].”
Metzner, C., Stringham, A., Hislop, B., Bonham, J., Chatterton, L., DeFigueiredo, R., & Charles, S. K. (2023) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.740 · Cited by 6
A Non-Invasive, Soft Robotic Wearable Glove to Attenuate Hand Tremors
Youhanaie, K., & Hashem, R. (2022) · Journal of Student Research · doi:10.47611/jsrhs.v11i3.3814 · Cited by 2
Wang, K., Wu, M., Sun, Z., & Huang, Q. (2024) · Sensors · doi:10.3390/s24165405 · Cited by 2
“Initial clinical evaluations revealed an effectiveness rate of 73% for ET, 62% for Parkinson’s disease tremors, and 38% for cerebellar tremors [14,15].”
BackgroundMechatronic Devices for Upper Limb Tremor
Zhou, Y., Daemi, P., Edmonds, B. P. R., Habibollahi, Z., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2023) · Contemporary clinical neuroscience · doi:10.1007/978-3-031-26128-2_22 · Cited by 1
Taina, A. E., Neamțu, M. C., Ligia, R., & Gabriel, M. D. M. (2010) · Cited by 3
Valdunciel, A. P. (2022) · UPM Digital Archive (Technical University of Madrid) · doi:10.20868/upm.thesis.71544 · Cited by 1
Bó, A. P. L. (2010) · theses.fr (ABES) · doi:10.70675/c65c8f82zcd5fz4e12z9e9cz6a38ef9757cf · Cited by 5
Gallego, J. Á., Rocón, E., Lois, J. M. B., & Pons, J. L. (2013) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-319-00846-2_431 · Cited by 1
Repetitive control based tremor suppression using electrical stimulation
Çopur, E. H., Freeman, C. T., Chu, B., & Laila, D. S. (2014) · UKACC International Conference on Control · doi:10.1109/control.2014.6915205
“FES was applied to suppress tremor at the wrist or elbow in [9], [10] using filters implemented in a closed-loop feedback arrangement.”
MethodModeling and Identification of Electrically Stimulated Muscles for Wrist Movement
Zhang, Z., Liu, Y., & Chu, B. (2018) · International Conference on Control, Automation, Robotics and Vision (ICARCV) · doi:10.1109/icarcv.2018.8581166 · Cited by 2
“uk) parkinsonian and cerebellar tremor patients were investigated, and the result showed that all the three types of tremors reduced by 73%, 62% and 38% respectively [16].”
BackgroundMethodDispositivos tecnológicos para la supresión del temblor
Blanco, R. L. (2022) · Kranion · doi:10.24875/kranion.m22000023
Design and Research of Electronic Control Module for Transanal Endoscopic Suture Device
周, 泽. (2022) · Software Engineering and Applications · doi:10.12677/sea.2022.113059
Hosseini, S. M., Farashi, S., & Bashirian, S. (2023) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-023-01255-z · Cited by 1
“Nine studies [17, 45–52] reported tremor suppression following electrical stimulation, while two other studies [53, 54] reported the worsening of tremor status after stimulation.”
ResultDesign of Parallel Exoskeleton System for Wrist Tremor Suppression
Janakaraj, S. J., & Barry, O. (2023) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2023.12.039
Low-cost IMU-based motion capture system and pneumatic exoskeleton design for assistive applications
Chen, Y. (2024) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/179556
Higher-Order Repetitive Control Enhanced FES for Wrist Intention Tremor Suppression
Ren, H., Liu, X., Zhang, Z., Duan, R., & Liu, Y. (2025) · Lecture notes in computer science · doi:10.1007/978-981-96-0777-8_3
External medical devices to suppress tremor
Kozlov, N. R., & Prokopenko, S. V. (2025) · Russian neurological Journal · doi:10.30629/2658-7947-2025-30-4-10-17
Additional file 1 of Peripheral electrical stimulation to reduce pathological tremor: a review
Valdunciel, A. P., Hoo, G. W., Avrillon, S., Barroso, F. O., Goldman, J. G., Hernandez-Pavon, J. C., & Pons, J. L. (2021) · Figshare · doi:10.6084/m9.figshare.14037710
Hosseini, S. M., Farashi, S., & Bashirian, S. (2024) · Figshare · doi:10.6084/m9.figshare.26619859
Metadata
- Authors
- Javidan, M., Elek, J., & Prochazka, A.
- Affiliations
- University of Alberta (CA)
- University of Bonn (DE)
- Venue
- Annals of Biomedical Engineering
- Published
- 1992-03
- Volume
- 20
- Issue
- 2
- Pages
- 225-236
- ISSN
- 0090-6964 (ISSN-L)
- 1573-9686
- OpenAlex
- W2166205679
- Cited by
- 80
- References
- 7
- Citations by year
- 2025: 2 · 2024: 5 · 2023: 5 · 2022: 8 · 2021: 11 · 2020: 3 · 2018: 2 · 2017: 4 · 2016: 1 · 2015: 8 · 2014: 4 · 2013: 5 · 2012: 2
- FWCI
- 0.95
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Annals of Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- functional electrical stimulation, tremor suppression, essential tremor, parkinsonian tremor, cerebellar tremor, multiple sclerosis, orthoses, clinical evaluation
- MeSH terms
- Adult, Cerebellar Diseases, Data Interpretation, Statistical, Electric Stimulation Therapy, Female, Humans, Male, Middle Aged, Movement, Multiple Sclerosis, Parkinson Disease, Pilot Projects, Tremor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.