Noninvasive automatic determination of mean arterial pressure
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The maximum amplitude algorithm is a conventional method to estimate mean arterial pressure, which is the cuff pressure at the maximum amplitude of the oscillometric waveform envelope, corresponding with unloading the arterial wall and where the transmural pressure is zero [44, 51, 52].”
From Automated 'oscillometric' blood pressure measuring devices: how they work and what they measure (2022) · cites this paper as [51]
Citations
Cites
Mauck, G. W., Smith, C. R., Geddes, L. A., & Bourland, J. D. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138195 · Cited by 222
Comparison of Indirect and Direct Methods of Measuring Arterial Blood Pressure
VAN BERGEN, F. H., WEATHERHEAD, D. S., TRELOAR, A. E., DOBKIN, A. B., & BUCKLEY, J. J. (1954) · Circulation · doi:10.1161/01.cir.10.4.481 · Cited by 195
Blood Pressure Measurement in Shock
Cohn, J. N. (1967) · JAMA · doi:10.1001/jama.1967.03120130058009 · Cited by 138
(1969) · PubMed · Cited by 96
Effect of size of cuff bladder on accuracy of measurement of indirect blood pressure
Simpson, J. A., Jamieson, G., Dickhaus, D. W., & Grover, R. F. (1965) · American Heart Journal · doi:10.1016/0002-8703(65)90069-4 · Cited by 77
Indirect Mean Blood Pressure in the Anesthetized Pony
Geddes, L. A., Chaffee, V., Whistler, S. J., BOURLAND, J. D., & Tacker, W. A. (1977) · American Journal of Veterinary Research · doi:10.2460/ajvr.1977.38.12.2055 · Cited by 45
Transcutaneous Doppler Measurement of Blood Pressure
Kirby, R. R., Kemmerer, W. T., & Morgan, J. L. (1969) · Anesthesiology · doi:10.1097/00000542-196907000-00026 · Cited by 30
Collins, V. J., & Magora, F. (1963) · Anesthesia & Analgesia · doi:10.1213/00000539-196307000-00011 · Cited by 10
Buggs, H., Pe, J., Ls, G., et al. (1973) · PubMed · Cited by 3
Buggs, H., JOHNSON, P. E., Ls, G., Fb, B., & WETTACH, G. E. (1973) · Anesthesia & Analgesia · doi:10.1213/00000539-197309000-00023 · Cited by 3
Research works printed but not linked: 1
- Geddes, L. A., Moore, A. G., Garner, H., Rosborough, J., Ross, J. andAmend, J. (1970) The indirect measurement of mean blood pressure in the horse.The Southwestern Veterinarian,23, 289–294.
Cited by
Items 101–200 of 286
Accuracy of some algorithms to determine the oscillometric mean arterial pressure
Raamat, R., Talts, J., Jagomägi, K., & Kivastik, J. (2012) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e32835d12f6 · Cited by 20
Predictors of Ambulatory Blood Pressure: Identification of High-Risk Adolescents
Meininger, J. C., Liehr, P. R., Mueller, W. H., Chan, W., & Chandler, P. S. (1998) · Advances in Nursing Science · doi:10.1097/00012272-199803000-00007 · Cited by 19
Definition of Normal Blood Pressure Range: The Elusive Target
Engle, W. D. (2008) · Elsevier eBooks · doi:10.1016/b978-1-4160-3162-8.10003-x · Cited by 17
Pilossoff, V., Sch�ber, J. G., Peters, D., & B�hlmeyer, K. (1985) · European Journal of Pediatrics · doi:10.1007/bf00441772 · Cited by 17
The Mean Machine; Accurate Non-invasive Blood Pressure Measurement in the Critically Ill Patient
Muecke, S., Bersten, A. D., & Plummer, J. (2009) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-009-9195-7 · Cited by 17
“Others have also provided evidence of the inadequacies of manual auscultation, palpation [11–13] or automated devices [14, 15] when used to measure pressure in the critically ill patient.”
BackgroundAssociation between ankle blood pressure and central arterial wave reflection
Tarumi, T., Sugawara, J., & Tanaka, H. (2010) · Journal of Human Hypertension · doi:10.1038/jhh.2010.100 · Cited by 18
Use of pulse oximetry for blood pressure measurement after cardiac surgery
Movius, A. J., Bratton, S. L., & Sorensen, G. K. (1998) · Archives of Disease in Childhood · doi:10.1136/adc.78.5.457 · Cited by 16
Yamakoshi, K., KAWARADA, A., Kamiya, A., Shimazu, H., & Ito, H. (1985) · Medical & Biological Engineering & Computing · doi:10.1007/bf02448934 · Cited by 18
Amoore, J. (1993) · Journal of Medical Engineering & Technology · doi:10.3109/03091909309009980 · Cited by 16
Jazbinšek, V., Lužnik, J., Mieke, S., & Trontelj, Z. (2009) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9853-4 · Cited by 17
Drake, M., & Hill, J. S. (2013) · Anaesthesia · doi:10.1111/anae.12194 · Cited by 18
“The basis of NIBP measurement by oscillometry is the determination of MAP from the maximum pulse oscillation during cuff deflation [11].”
MethodIdea to measure diastolic arterial pressure by volume oscillometric method in human fingers
Shimazu, H., Ito, H., Kobayashi, H., & Yamakoshi, K. (1986) · Medical & Biological Engineering & Computing · doi:10.1007/bf02443975 · Cited by 16
Automated Blood Pressure Recording: The Phenomenon of Blood Pressure Elevations During Speech
Malinow, K. L., Lynch, J. J., Thomas, S. A., Friedmann, E., & Long, J. M. (1982) · Angiology · doi:10.1177/000331978203300707 · Cited by 15
Automatic Postoperative Monitoring of Infrainguinal Bypass Procedures
Blebea, J. (1997) · Archives of Surgery · doi:10.1001/archsurg.1997.01430270072014 · Cited by 14
Lee, Q. Y., Chan, G. S. H., Redmond, S. J., Middleton, P. M., Steel, E., Malouf, P. J., Critoph, C., Flynn, G., O’Lone, E., & Lovell, N. H. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5628062 · Cited by 14
“Whilst MAP can be reliably obtained from noninvasive techniques using inflatable cuffs (such as the oscillometric method [5]), the measurement of CO and CVP typically involves an invasive procedure of catheterization.”
MethodRetinal microvasculature is a potential biomarker for acute mountain sickness
Xie, Y., Yang, D., Huang, A. S., Yang, Y., Han, Y., Sun, Y., Cao, K., Wang, H., Wu, S., Zhu, Q., et al. (2023) · Science China Life Sciences · doi:10.1007/s11427-022-2271-x · Cited by 14
“terial pressure was determined by the following equation: MBP=1/3×SBP+2/3×DBP (Ramsey, 1979).”
MethodComparison of Non-invasive Blood Pressure Measurements on the Arm and Calf During Cesarean Delivery
Zahn, J., Bernstein, H., Hossain, S., Bodian, C., & Beilin, Y. (2000) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1012267312308 · Cited by 14
Alcohol Consumption and Prehypertension: An Investigation of University Youth
Jorgensen, R. S., & Maisto, S. A. (2008) · Behavioral Medicine · doi:10.3200/bmed.34.1.21-28 · Cited by 16
Wu, H., Wang, B., Zhu, X., Chu, G. Q., & Zhang, Z. (2016) · Medicine · doi:10.1097/md.0000000000004538 · Cited by 15
Amoore, J., Geake, W. B., & Scott, D. H. T. (1997) · Medical & Biological Engineering & Computing · doi:10.1007/bf02534143 · Cited by 14
Definition of Normal Blood Pressure Range
Engle, W. D. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4377-2763-0.00003-2 · Cited by 14
Lynch, J. J., Lynch, K. E., & Friedmann, E. (1992) · Integrative Psychological and Behavioral Science · doi:10.1007/bf02698504 · Cited by 14
Kayrak, M., Ülgen, M. S., Yazıcı, M., Yılmaz, R., Demır, K., Dogan, Y., Özhan, H., Alihanoğlu, Y. İ., Koç, F., & Bodur, S. (2010) · Blood Pressure · doi:10.3109/08037050903516318 · Cited by 14
Ramos, S. J., da Cunha, A. F., Domingues, M., Shelby, A. M., Stout, R. W., & Acierno, M. J. (2015) · American Journal of Veterinary Research · doi:10.2460/ajvr.77.1.59 · Cited by 13
The Measurement of Blood Pressure
Pickering, T. G., & Blank, S. G. (1989) · Springer eBooks · doi:10.1007/978-1-4899-0906-0_4 · Cited by 13
Skrabal, F., Hamberger, L., Gruber, G., Meister, B., Doll, P., & Cerny, E. (1985) · Journal of Molecular Medicine · doi:10.1007/bf01738142 · Cited by 13
Comparison between oscillometric and invasive blood pressure monitoring during cardiac surgery
Green, M., Paulus, D. A., Roan, V. P., & van der Aa, J. J. (1984) · International journal of clinical monitoring and computing · doi:10.1007/bf01726658 · Cited by 12
Ukawa, T., Takayanagi, T., Morimoto, H., Higashi, Y., Idei, N., Yoshizumi, M., & Tsuji, T. (2012) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-0955-z · Cited by 12
Noninvasive Determination of Central Blood Pressure by Impedance Plethysmography
Herscovici, H., & Roller, D. H. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325843 · Cited by 12
Three months use of third-generation oral contraceptives does not affect artery wall properties
Willekes, C., Hoogland, H. J., KEIZER, H. A., Hoeks, A. P. G., & Reneman, R. S. (1999) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(99)00020-4 · Cited by 13
An arm phantom: a digital simulation system for testing sphygmomanometers
Groß, H., Mieke, S., & Ulbrich, M. (1996) · Journal of Medical Engineering & Technology · doi:10.3109/03091909609008383 · Cited by 12
Helmer, P., Helf, D., Sammeth, M., Winkler, B. E., Hottenrott, S., Meybohm, P., & Kranke, P. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11154498 · Cited by 11
“MAP is defined as the lowest cuff pressure with the highest oscillation in the arterial curve [9].”
BackgroundCalculated mean arterial blood pressure in critically ill neonates
Gevers, M., Hack, W. W. M., Ree, E. F., Lafeber, H. N., & Westerhof, N. (1993) · Basic Research in Cardiology · doi:10.1007/bf00788533 · Cited by 11
Vibration technique for indirect measurement of diastolic arterial pressure in human fingers
Shimazu, H., Ito, H., KAWARADA, A., Kobayashi, H., Hiraiwa, A., & Yamakoshi, K. (1989) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446221 · Cited by 13
Noninvasive Blood Pressure Measurement
Sanford, T. J., Jones, B. R., & Smith, N. T. (1988) · Anesthesiology Clinics of North America · doi:10.1016/s0889-8537(21)00242-x · Cited by 11
Hansen, K. W. (1996) · Journal of Diabetes and its Complications · doi:10.1016/s1056-8727(96)00065-7 · Cited by 11
HearBP: Hear Your Blood Pressure via In-ear Acoustic Sensing Based on Heart Sounds
Zhao, Z., Li, F., Xie, Y., Xie, H., Zhang, K., Zhang, L., & Wang, Y. (2024) · IEEE Conference on Computer Communications (INFOCOM) · doi:10.1109/infocom52122.2024.10621249 · Cited by 10
“The commonly used clinical non-invasive methods mainly utilize BP sensors with inflatable cuffs to compress arterial blood vessels, and measure BP based on the special sounds (e.g., korotkoff sound) of blood vessels under different pressures and various oscillation phenomena [6], [7].”
Methodde Mey, C., Schroeter, V., Butzer, R., Roll, S., & Belz, G. (1995) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.1995.tb04549.x · Cited by 10
Blood pressure reactivity: Pitfalls in methodology
Cumes-Rayner, D. P., & Price, J. (1988) · Journal of Psychosomatic Research · doi:10.1016/0022-3999(88)90053-0 · Cited by 10
Linden, W., & Zimmermann, B. (1984) · Applied Psychophysiology and Biofeedback · doi:10.1007/bf00998837 · Cited by 10
Auditing the technology used to measure blood pressure
Amoore, J., Guehenec, M., Scordecchia, R., & Scott, D. H. T. (2010) · Journal of Medical Engineering & Technology · doi:10.3109/03091900903518991 · Cited by 10
Noaman, N. M., & Abbas, A. K. (2007) · Springer eBooks · doi:10.1007/978-3-540-73044-6_98 · Cited by 9
Taleyarkhan, P. R., Geddes, L. A., Kemeny, A. E., & Vitter, J. S. (2009) · Cardiovascular Engineering An International Journal · doi:10.1007/s10558-009-9077-0 · Cited by 9
“…of Biomedical Engineering, Purdue University, 206 S. Martin Jischke Drive, West Lafayette, IN 47907-2032, USA e-mail: pervinrt@gmail.com J. S. Vitter College of Chemical Engineering, University of Notre Dame, Notre Dame, IN 46556, USA pressure oscillations (Posey et al. 1969; Ramsey 1979, 1991).”
BackgroundPoulsen, L. (2002) · Journal of the Renin-Angiotensin-Aldosterone System · doi:10.3317/jraas.2002.044 · Cited by 9
Noninvasive Blood Pressure Measurement in the Neonate
Darnall, R. A. (1985) · Clinics in Perinatology · doi:10.1016/s0095-5108(18)30883-2 · Cited by 9
Lee, T. K., & Westenskow, D. R. (1998) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1007481416222 · Cited by 9
Baura, G. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-811984-6.00007-6 · Cited by 9
A quantitative evaluation of the Hewlett-Packard 78354A noninvasive blood pressure meter
Whalen, P., & Ream, A. K. (1988) · Journal of Clinical Monitoring and Computing · doi:10.1007/bf01618104 · Cited by 9
Automatic Oscillometric NIBP Versus Manual Auscultatory Blood Pressure in the PACU
Ramsey, M. (1994) · Journal of Clinical Monitoring and Computing · doi:10.1007/bf02886828 · Cited by 9
“The accuracy of automated oscillometric NIBP measurements has been well substantiated over the past 15 years [11-19].”
MethodSelf-citationXie, Y., Fu, Y., Shao, Y., Qu, L., Yang, J., Yang, C., Zhou, K., Li, K., Xu, Z., Xu, D., et al. (2024) · npj Microgravity · doi:10.1038/s41526-024-00347-x · Cited by 9
Mean arterial pressure differences between cuff oscillometric and invasive blood pressure
Picone, D. S., Schultz, M. G., Armstrong, M. K., Black, J. A., Dwyer, N., Roberts‐Thomson, P., Weber, T., & Sharman, J. E. (2025) · Hypertension Research · doi:10.1038/s41440-025-02165-4 · Cited by 9
“This feature is derived from the cuff de fl ation (or sometimes in fl ation) curve using proprietary algorithms (i.e. not publicly available) and is assumed to accurately represent the mean arterial pressure (MAP) based on intra-arterial con fi rmation in early studies of the 1970 ’ s [10].”
Modeling of Noninvasive Arterial Blood Pressure Methods
Drzewiecki, G. M. (1998) · Springer eBooks · doi:10.1007/978-1-4612-1744-2_13 · Cited by 8
Genç, Y. K., Altunkan, Ş., Klnç, O., & Altunkan, E. (2008) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3282f13f20 · Cited by 8
Noninvasive Arterial Blood Pressure and Mechanics
Drzewiecki, G. M. (2006) · The electrical engineering handbook/Electrical engineering handbook series/Electrical engineering handbook · doi:10.1201/9781420003864.ch55 · Cited by 8
Silke, B., Thompson, A., Leitch, A., & Riddell, J. (1995) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.1995.tb04532.x · Cited by 8
A novel psychophysiological treatment for vasovagal syncope
Khurana, R. K., Lynch, J. J., & Craig, F. W. (1997) · Clinical Autonomic Research · doi:10.1007/bf02267981 · Cited by 9
Measurement of Neonatal Blood Pressure: A New Method
Hall, P. S., Thomas, S. A., Friedmann, E., & Lynch, J. J. (1982) · Psychophysiology · doi:10.1111/j.1469-8986.1982.tb02552.x · Cited by 8
Sakamaki, T., Tajima, Y., Ichikawa, S., & Murata, K. (1987) · EXPERIMENTAL ANIMALS · doi:10.1538/expanim1978.36.4_409 · Cited by 9
A Modeling Approach for Coefficient-Free Oscillometric Blood Pressure Estimation
Forouzanfar, M. (2014) · uO Research (University of Ottawa) · doi:10.20381/ruor-4926 · Cited by 11
“The most common of these techniques are Doppler ultrasound sphygmomanometry [4], oscillometry [5, 6], plethysmography [7], tonometry [8], and vascular unloading [9].”
Ubicon-BP: Towards Ubiquitous, Contactless Blood Pressure Detection Using Smartphone
Wu, Y. L., Bai, S., Hu, Q., Wang, B., Li, M., Hu, X., & Chen, Y. (2025) · IEEE Transactions on Mobile Computing · doi:10.1109/tmc.2025.3551315 · Cited by 11
An improved algorithm for noninvasive blood pressure measurement
Wang, Q., Wang, Y., Mei, Z., & Liu, Z. (2011) · International Symposium on Bioelectronics and Bioinformatics (ISBB) · doi:10.1109/isbb.2011.6107640 · Cited by 7
“The proportional coefficient method determines the systolic and diastolic pressure by the ratios of systolic and diastolic pressure [7].”
MethodSystematic Errors in Estimating Mean Blood Pressure from Finger Blood Pressure Measurements
O'CALLAGHAN, N. E. C. J. (1998) · Blood Pressure · doi:10.1080/080370598437123 · Cited by 7
Mobile Environmental Sensing Using Smartphones
Aram, S., Toriono, A., Rugiano, F., & Pasero, E. (2014) · CRC Press eBooks · doi:10.1201/b15664-73 · Cited by 7
Kasper, S., Dahlmann, H., Mellinghoff, H., Ellering, J., Baumann, M., & Buzello, W. (1998) · Vox Sanguinis · doi:10.1046/j.1423-0410.1998.7510026.x · Cited by 7
Temporal Patterns Of Heart Rate and Blood Pressure in Elders
Dunbar, S. B., & Farr, L. (1996) · Nursing Research · doi:10.1097/00006199-199601000-00008 · Cited by 7
Yang, F., Chen, F., Zhu, M., Chen, A., & Zheng, D. (2017) · BioMed Research International · doi:10.1155/2017/5201069 · Cited by 6
Blood Pressure Difference between the Measurements taken during Cuff Inflation and Deflation
Zheng, D., Marco, L. Y. D., & Murray, A. (2012) · Computing in cardiology · doi:10.25405/ncl.34197828 · Cited by 6
Automating Blood Pressure Measurements: The Division of Labour and the Transformation of Method
Hartland, J. (1998) · Palgrave Macmillan UK eBooks · doi:10.1007/978-1-349-13693-3_14 · Cited by 6
Arfeen, Z., Maran, N., Simón, E., & McClure, J. H. (1996) · International Journal of Obstetric Anesthesia · doi:10.1016/s0959-289x(96)80026-4 · Cited by 6
Effect of Acute Ethanol Ingestion on Orthostatic Vital Signs
Tomaszewski, C., Cline, D. M., Whitley, T. W., & Grant, T. (1995) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(95)70177-x · Cited by 6
Automated Blood Pressure Measurement: Reasons for Measurement Variability Uncovered
Zheng, D., Jn, A., Mieke, S., Smith, F., King, S., & Murray, A. (2009) · Computers in Cardiology Conference · doi:10.25405/ncl.34119144 · Cited by 6
Compensation of the Error Rate for the Non-invasive Sphygmomanometer System Using a Tactile Sensor
Jeong, I., Choi, Y.-N., & Yoon, H.-R. (2007) · Journal of Electrical Engineering and Technology · doi:10.5370/jeet.2007.2.1.136 · Cited by 6
Oscillometric Noninvasive Blood Pressure Measurement Devices and Simulators
Amoore, J., & Murray, I. C. (2006) · Journal of Clinical Engineering · doi:10.1097/00004669-200604000-00026 · Cited by 6
Cuff Under Pressure for Greater Accuracy
Picone, D. S., Schultz, M. G., Hughes, A. D., & Sharman, J. E. (2020) · Current Hypertension Reports · doi:10.1007/s11906-020-01103-8 · Cited by 7
Noninvasive Arterial Pressure Monitoring
Settels, J. J. (2013) · Springer eBooks · doi:10.1007/978-1-4614-8557-5_12 · Cited by 5
Watson, M. K., & Chinnadurai, S. K. (2019) · Journal of Zoo and Wildlife Medicine · doi:10.1638/2018-0099 · Cited by 5
Klose, P., Lorenzen, U., Berndt, R., Borzikowsky, C., Hill, M., Gruenewald, M., Elke, G., & Renner, J. (2020) · Health Science Reports · doi:10.1002/hsr2.204 · Cited by 6
“Blood pressure measurement is one key factor and is most commonly performed using the the noninvasive oscillometric method with an inflatable cuff at the upper limb.(8) However, the gold standard is the continuous invasive beat to beat blood pressure monitoring using an arterial line.”
MethodBlood flow and pressure in a brachial artery under cuff pressure
Kim, H. J., Lee, H. C., Kim, C. H., Kim, Y. J., & Jeon, G. R. (2005) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2004.1432284 · Cited by 5
Gui, Y., Chen, F., Murray, A., & Zheng, D. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512996 · Cited by 6
Contrasting Actions of Celiprolol and Metoprolol on Cardiac Performance in Normal Volunteers
Silke, B., Thompson, A., & Riddell, J. G. (1997) · Cardiovascular Drugs and Therapy · doi:10.1023/a:1007799807554 · Cited by 5
Counterpressure: the concept that made the indirect measurement of blood pressure possible
Geddes, L. A. (1998) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.731326 · Cited by 5
Left ventricular performance during psychological stress
Young, D. Z., Dimsdale, J., Moore, H., Barlai-Kovach, M., Newell, J., McKusick, K. A., Boucher, C., Fifer, M. A., & Strausś, H. W. (1989) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/bf00254622 · Cited by 5
Evaluation of a new ambulatory blood pressure device
GERMANO, G., Muscolo, M., Angotti, S., BRAVO, S., CODISPOTI, P., FEDERICO, L., & Damiani, S. (1998) · American Journal of Hypertension · doi:10.1016/s0895-7061(98)00147-2 · Cited by 5
Abbasi, S., nejad, A. E., Kashefi, P., & Kiaei, B. A. (2018) · Advanced Biomedical Research · doi:10.4103/abr.abr_148_18 · Cited by 4
“6 Advanced Biomedical Research | 2018 hemodynamic parameter, and regarding the normal range of MAP,[35] there was not any disadvantage for treatment approaches.”
Evaluation of oscillometric blood pressure monitor BLT M9000 VET in anaesthetised healthy adult dogs
Zrimšek, P., Sredenšek, J., Vengušt, M., & Seliškar, A. (2018) · Journal of Small Animal Practice · doi:10.1111/jsap.12811 · Cited by 4
Cremer, J., da Cunha, A. F., Paul, L. J., Liu, C., & Acierno, M. J. (2019) · American Journal of Veterinary Research · doi:10.2460/ajvr.80.12.1067 · Cited by 4
Chen, C.-J., Hiramatsu, K., Ooue, T., Takagi, K., & Yamamoto, T. (1991) · Journal of Sound and Vibration · doi:10.1016/0022-460x(91)90535-r · Cited by 4
Baura, G. (2011) · Elsevier eBooks · doi:10.1016/b978-0-12-374976-5.00007-4 · Cited by 4
Asymmetrical oscillometric pulse waveform envelopes in normotensive and hypertensive subjects
Zheng, D., Giovannini, R., & Murray, A. (2010) · Pure (Coventry University) · doi:10.25405/ncl.34171152 · Cited by 7
Blodtrykksapparater på legekontorer
Moe, N., Getz, L., Dahl, K. J., & Hetlevik, I. (2010) · Tidsskrift for Den norske legeforening · doi:10.4045/tidsskr.09.0781 · Cited by 4
The Indirect Measurement of Blood Pressure
Geddes, L. A. (1991) · Humana Press eBooks · doi:10.1007/978-1-4684-7170-0_2 · Cited by 4
TECHNICAL EQUIPMENT FOR BLOOD PRESSURE RECORDING
Nielsen, P. E. (1982) · Acta Medica Scandinavica · doi:10.1111/j.0954-6820.1982.tb09875.x · Cited by 4
Gevers, M., Hack, M. W. M., van Genderingen, H. R., Lafeber, H. N., & Westerhof, N. (1995) · Basic Research in Cardiology · doi:10.1007/bf00805668 · Cited by 4
Rustin, M. H. A., & Coomes, E. N. (1983) · Postgraduate Medical Journal · doi:10.1136/pgmj.59.698.770 · Cited by 4
Commentary: Britain does better than germany before patients reach hospital: Table 1
Siewert, J. R., & Fink, U. (1997) · BMJ · doi:10.1136/bmj.314.7079.471 · Cited by 5
Zhu, G., Zhao, D. Y., Song, Y., Wang, Z., Zhou, A., Ma, H., Meng, X., Wang, J., Shao, C., & Tang, Y. (2025) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3731600 · Cited by 5
“There are many pressure-assisted methods, including auscultation [54], oscillometry [47], and volume clamp [46].”
Non-invasive determination of instantaneous brachial blood flow using the oscillometric method
Liu, S.-H., Wang, J.-J., & Cheng, D. (2009) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2009.020 · Cited by 3
Silke, B., de la Motte, S., Spiers, P., Herity, N., Drake, M., Kelly, J. G., & Harrison, F. (1996) · Cardiovascular Drugs and Therapy · doi:10.1007/bf00050999 · Cited by 3
Cardiovascular response to speaking in schizophrenics
Hsiao, J., Lynch, J. J., Foreman, P. J., & Gross, H. S. (1987) · Psychiatry Research · doi:10.1016/0165-1781(87)90052-7 · Cited by 3
Metadata
- Authors
- Ramsey, M.
- Affiliations
- University of South Florida (US)
- Corresponding author
- Ramsey, Maynard
- Venue
- Medical and Biological Engineering and Computing
- Published
- 1979-01
- Volume
- 17
- Issue
- 1
- Pages
- 11-18
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W2909014974
- Semantic Scholar
- ba92a51d908a441e23b4b032943e695ac3e49a0c
- Cited by
- 287
- References
- 10
- Citations by year
- 2026: 4 · 2025: 5 · 2024: 9 · 2023: 4 · 2022: 5 · 2021: 5 · 2020: 7 · 2019: 4 · 2018: 8 · 2017: 8 · 2016: 3 · 2015: 7 · 2014: 5 · 2013: 5 · 2012: 7
- FWCI
- 8.03
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Medical & Biological Engineering & Computing (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Keywords
- mean arterial pressure, non-invasive blood pressure measurement, artefact rejection, cuff deflation, cuffless blood pressure measurement
- MeSH terms
- Adult, Aged, Blood Pressure Determination, Female, Humans, Male, Middle Aged, Monitoring, Physiologic, Oscillometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.