Noninvasive automatic determination of mean arterial pressure
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The maximum amplitude algorithm is a conventional method to estimate mean arterial pressure, which is the cuff pressure at the maximum amplitude of the oscillometric waveform envelope, corresponding with unloading the arterial wall and where the transmural pressure is zero [44, 51, 52].”
From Automated 'oscillometric' blood pressure measuring devices: how they work and what they measure (2022) · cites this paper as [51]
Citations
Cites
Mauck, G. W., Smith, C. R., Geddes, L. A., & Bourland, J. D. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138195 · Cited by 222
Comparison of Indirect and Direct Methods of Measuring Arterial Blood Pressure
VAN BERGEN, F. H., WEATHERHEAD, D. S., TRELOAR, A. E., DOBKIN, A. B., & BUCKLEY, J. J. (1954) · Circulation · doi:10.1161/01.cir.10.4.481 · Cited by 195
Blood Pressure Measurement in Shock
Cohn, J. N. (1967) · JAMA · doi:10.1001/jama.1967.03120130058009 · Cited by 138
(1969) · PubMed · Cited by 96
Effect of size of cuff bladder on accuracy of measurement of indirect blood pressure
Simpson, J. A., Jamieson, G., Dickhaus, D. W., & Grover, R. F. (1965) · American Heart Journal · doi:10.1016/0002-8703(65)90069-4 · Cited by 77
Indirect Mean Blood Pressure in the Anesthetized Pony
Geddes, L. A., Chaffee, V., Whistler, S. J., BOURLAND, J. D., & Tacker, W. A. (1977) · American Journal of Veterinary Research · doi:10.2460/ajvr.1977.38.12.2055 · Cited by 45
Transcutaneous Doppler Measurement of Blood Pressure
Kirby, R. R., Kemmerer, W. T., & Morgan, J. L. (1969) · Anesthesiology · doi:10.1097/00000542-196907000-00026 · Cited by 30
Collins, V. J., & Magora, F. (1963) · Anesthesia & Analgesia · doi:10.1213/00000539-196307000-00011 · Cited by 10
Buggs, H., Pe, J., Ls, G., et al. (1973) · PubMed · Cited by 3
Buggs, H., JOHNSON, P. E., Ls, G., Fb, B., & WETTACH, G. E. (1973) · Anesthesia & Analgesia · doi:10.1213/00000539-197309000-00023 · Cited by 3
Research works printed but not linked: 1
- Geddes, L. A., Moore, A. G., Garner, H., Rosborough, J., Ross, J. andAmend, J. (1970) The indirect measurement of mean blood pressure in the horse.The Southwestern Veterinarian,23, 289–294.
Cited by
Items 201–286 of 286
Jones, R., Sun, M., & Rithalia, S. (1999) · CRC Press eBooks · doi:10.1201/9780415876179.ch75 · Cited by 3
BLOOD PRESSURE IN SWEDISH SCHOOL CHILDREN
Wilton, P. (1983) · Acta Paediatrica · doi:10.1111/j.1651-2227.1983.tb09758.x · Cited by 3
Sidery, M. B., & Macdonald, I. A. (1991) · Clinical Autonomic Research · doi:10.1007/bf01826214 · Cited by 3
de Mey, C., & Erb, K. A. (1997) · The Journal of Clinical Pharmacology · doi:10.1177/009127009703700117 · Cited by 3
An ‘admission challenge test’ to predict severe hypertension in pregnancy?
Mooney, P., & Dalton, K. J. (1990) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/0028-2243(90)90141-m · Cited by 3
Nichtinvasives Monitoring von Druck und Strömung im Kreislauf
Pasch, T. (1985) · Springer eBooks · doi:10.1007/978-3-642-69893-4_22 · Cited by 3
MONITORING THE PERIPHERAL VASCULAR SYSTEM
Jones, B. R., & Hughes, S. A. (1994) · Anesthesiology Clinics of North America · doi:10.1016/s0889-8537(21)00704-5 · Cited by 3
Edge-assisted multi-user millimeter-wave radar for non-contact blood pressure monitoring
Ji, X., Dong, F., Huang, Z., Guo, X., Zhu, H., Chen, B., & Shen, J. (2025) · Applied Computing and Intelligence · doi:10.3934/aci.2025004 · Cited by 2
Northeast Asia Interconnection, and Power Flow Analysis Considering Seasonal Load Patterns
Lee, S.-S., Kim, Y.-C., Park, J., Lee, S., Osawa, M., Moon, S., & Yoon, Y. (2007) · Journal of Electrical Engineering and Technology · doi:10.5370/jeet.2007.2.1.001 · Cited by 2
Arntzenius, A. C., Bonjer, F. H., Huige, M. C., & van Vollenhoven, E. (1980) · Developments in cardiovascular medicine · doi:10.1007/978-94-009-8893-4_1 · Cited by 2
Jaouhari, S. D. E., Meziane, M., Kessouati, J., Razıne, R., Jaafari, A., & Bensghir, M. (2020) · Pan African Medical Journal · doi:10.11604/pamj.2020.36.31.21019 · Cited by 2
“The basis of NIBP measurement by oscillometry is the determination of MAP from the maximum pulse oscillation during cuff deflation [7].”
MethodThe modified step-wise deflation method in blood pressure measurement
Oh, H. S., Chee, Y. J., Lee, J. S., Kim, I. Y., Kim, S. I., & Kim, Y.-H. (2008) · Computers in cardiology · doi:10.1109/cic.2008.4749004 · Cited by 2
“For the validation of our suggested method, human observer assessed SBP / DBP according to EHS (European Hypertension Society) guideline.”
MethodMétodos de medida da pressão arterial - passado, presente e futuro
Menezes, F., & de Souza, C. (2003) · Cited by 2
Block, F. E., Fletcher, M. V., Morris, T. J., & Dzwonczyk, R. R. (1991) · The Journal of Clinical Monitoring · doi:10.1007/bf01619267 · Cited by 2
A Matlab demo software for NIBP measurement based on hybrid oscillometric method
Huang, P. C., Fu, J., & Zhao, Y. (2011) · International Congress on Image and Signal Processing (CISP) · doi:10.1109/cisp.2011.6100763 · Cited by 2
“At present the auscultatory method [5] and oscillometric method [6] are the most popular in research and commercial areas.”
MethodChin, K. Y., & Panerai, R. B. (2014) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2014.979953 · Cited by 3
“Ramsey III [18] Oscillometric In vivo Human Bicep/calf/ankle 0.”
BackgroundSaugstad, O. D. (2018) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2018.02.049 · Cited by 2
Sidhu, E., & Groza, V. F. (2018) · International Conference on Intelligent Systems · Cited by 2
Basic principles and limitations of electrocardiographic and haemodynamic bedside monitoring
Teplick, R. S. (2000) · Best practice & research. Clinical anaesthesiology · doi:10.1053/bean.2000.0062 · Cited by 2
Resting and Reactive Blood Pressure
Frazier, L. Q. (2002) · Journal of Gerontological Nursing · doi:10.3928/0098-9134-20020901-04 · Cited by 2
Hoelscher, T. J. (1987) · Applied Psychophysiology and Biofeedback · doi:10.1007/bf01000074 · Cited by 2
Correlation study of arterial blood pressure level to the amplitude of the pressure pulse waveform
Vachtsevanos, G., Kalaitzakis, K. C., Papamarkos, N., Ziakas, G., Economou, K. N., & Gemitzis, K. (1984) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(84)90007-4 · Cited by 2
COMPARISON OF BLOOD PRESSURE IN THE ARM AND ANKLE IN PATIENTS IN THE EMERGENCY DEPARTMENT
Goldstein, L. N. (2013) · University of the Witwatersrand, Johannesburg Institutional Repository on DSpace (University of the Witwatersrand, Johannesburg) · Cited by 2
Methods for Non-invasive Trustworthy Estimation of Arterial Blood Pressure
Koohi, I. (2017) · uO Research (University of Ottawa) · doi:10.20381/ruor-20113 · Cited by 2
“Chronic patient conditions, like atrial fibrillation (AF) and heart failure, and noise such as motion artifacts tend to render NIBP estimations somewhat inaccurate and untrusted [10-12].”
BackgroundMethodKarimian, S., Yazdchi, M., & Hajian, R. (2022) · Journal of Medical Signals & Sensors · doi:10.4103/jmss.jmss_123_21 · Cited by 1
“Although the linear method has a high‐speed performance, it would be easily affected by noise and motion artifacts.[8]”
MethodPoster: FlexibleBP: Blood Pressure Monitoring Using Wrist-worn Flexible Sensor
Zhang, Y., Li, B., Peng, Y., Li, J., Sun, T., & Zhang, J. (2024) · ACM Conference on Embedded Networked Sensor Systems (SenSys) · doi:10.1145/3666025.3699415 · Cited by 1
“However, arterial catheteriza-tion’s invasiveness and cuff discomfort from non-invasive methods like auscultation [3, 5] highlighting the need for developing comfortable, non-invasive BP monitoring.”
Validation of a blood pressure simulator that regenerates oscillometric cuff pressure waveforms
Zheng, D., Liu, C., Amoore, J., Mieke, S., & Murray, A. (2015) · Newcastle University ePrints (Newcastle Univesity) · doi:10.25405/ncl.34304589 · Cited by 1
Accurate blood pressure measurement
Sherwood, J. (1979) · Preventive Medicine · doi:10.1016/0091-7435(79)90260-3 · Cited by 1
Sebbag, I., Massey, S. R., Albert, A., Dube, A., Gunka, V. B., & Douglas, M. J. (2015) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000817 · Cited by 1
A Cluster Method to Noninvasive Continuous Blood Pressure Measurement Using PPG
Yu, M., Zhang, Z., Meng, L., Xie, X., & Pan, H. (2017) · Lecture notes in computer science · doi:10.1007/978-3-319-59858-1_11 · Cited by 1
History of Blood Pressure Measurement in Newborns and Infants
Javorka, K. (2023) · Physiological Research · doi:10.33549/physiolres.935173 · Cited by 1
“Automatic measurement of BP by a device based on oscillometric technique was first described by Ramsey in 1979 [54].”
MethodVollebregt, K. C., Boer, K., van der Post, J., & WOLF, H. (2012) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1111/j.1600-0412.2012.01510.x · Cited by 1
“The Spacelabs 90207e is an oscillometric device and the MAP is estimated primarily by the pressure where oscillations are largest, with SBP and DBP being derived from this point (29).”
MethodAdvanced sensors technology survey
Cooper, T., Costello, D. J., Davis, J. G., Horst, R. L., Lessard, C. S., Peel, H. H., & Tolliver, R. L. (1992) · STIN · Cited by 1
Aditya, A., Riyadi, M. A., & Darjat, D. (2016) · Transient Jurnal Ilmiah Teknik Elektro · doi:10.14710/transient.5.1.1-7 · Cited by 3
McIntyre, J. W. R., & Finucane, B. T. (2017) · Springer eBooks · doi:10.1007/978-3-319-49386-2_2 · Cited by 1
Anesthesia in the late 1960s at Peter Bent Brigham Hospital, Boston: A case report
Pilon, R. N., & Desai, S. P. (2020) · Journal of Anesthesia History · doi:10.1016/j.janh.2020.07.005 · Cited by 2
Evaluation of Devices for Measurement of Blood Pressure
Meidert, A. S., & Saugel, B. (2021) · Springer eBooks · doi:10.1007/978-3-030-73387-2_19 · Cited by 1
Grove, M., Paliwal, M., Shearin, A., Kaiser, J., Koo, E. S., Howey, D., Galati, M., Czekalski, B., Dumawal, J., DeCarvalho, B., et al. (2023) · Stroke Vascular and Interventional Neurology · doi:10.1161/svin.122.000711 · Cited by 1
“10 In 1969, Posey et al and Geddes et al showed that the point of maximum oscillation corresponds to true MAP.”
Office Blood Pressure Measurement
Grim, C. E., & Grim, C. M. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-88369-6.00009-8 · Cited by 1
24-hour ambulatory blood pressure monitoring
Schächinger, H., & Langewitz, W. A. (1997) · Baillière s Clinical Anaesthesiology · doi:10.1016/s0950-3501(97)80044-x · Cited by 1
Design and development of a new electronic sphygmomanometer
Vachtsevanos, G., Kalaitzakis, K. C., & Papamarkos, N. (1985) · Medical & Biological Engineering & Computing · doi:10.1007/bf02448933 · Cited by 1
Jeong, I. C., Choi, Y. N., Park, S. W., & Yoon, H. R. (2007) · Springer eBooks · doi:10.1007/978-3-540-36841-0_1046 · Cited by 1
Automatic determination of penile blood pressure in evaluation of vasculogenic impotence
Vignoli, G. (1982) · Urology · doi:10.1016/0090-4295(82)90635-5 · Cited by 1
Mean Arterial Pressure in Acute Ischemic Stroke Study
Grove, M. (2020) · doi:10.21007/etd.cghs.2020.0511 · Cited by 1
“MAP is selected as the lowest cuff pressure at which the oscillation amplitude is a maximum.(29) SBP and DBP values are then algorithmically derived from the MAP(99,100).”
BackgroundMethodInfluential(2011) · CRC Press eBooks · doi:10.1201/b10775-3 · Cited by 1
Commentary: Japanese point of view
Sano, T., & Maruyama, K. (1997) · BMJ · doi:10.1136/bmj.314.7079.470 · Cited by 1
Monitoring High-Risk and Criticially III Patients
Polacek, D. J. (1986) · CPOBGYN. Clinical perspectives in obstetrics and gynecology · doi:10.1007/978-1-4612-4924-5_10
Blutdruckmessung — ein Problem?
Anlauf, M. (1983) · Steinkopff eBooks · doi:10.1007/978-3-642-72374-2_2
Apport des nouvelles technologies: vers une mesure non invasive de la pression artérielle pulsée ?
Estevez, M. G., Robin, E., & Vallet, B. (2012) · Réanimation · doi:10.1007/s13546-012-0457-x
Hemodynamic Measurements and Clinical Monitoring
Li, J. K. ‐. (2000) · Humana Press eBooks · doi:10.1007/978-1-59259-034-6_5
Development Of Automatic Blood Pressure Meter In Home
Kim, N. H., Kim, W. K., Huh, J. M., & Choi, T. Y. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1990.691285
Baik, S.-W., Park, S., Shon, J.-M., Park, G., Lee, S., Jang, W., Jeon, A.-Y., & Jeon, G.-R. (2013) · Journal of Sensor Science and Technology · doi:10.5369/jsst.2013.22.2.136
“혈압을측정하기위한방법은직접도관 을 혈관에 삽입하여 측정하는 직접적 방식인 침습적 혈압(IBP, Invasive Blood Pressure) 측정법과청진음이나압박대의압력변 화 등을 이용한 간접적 방식인 비침습적 혈압(NIBP, NonInvasive Blood Pressure) 측정법이 있다[3-6].”
Factitious Arterial Blood Pressure Measurements from Automated Oscillotonometer
Cohen, D. E., & Keon, T. P. (2000) · Anesthesia & Analgesia · doi:10.1097/00000539-200006000-00014
HEMODYNAMIC MONITORING OF TRAUMA PATIENTS DURING ANESTHESIA
Karlin, A. (1996) · Anesthesiology Clinics of North America · doi:10.1016/s0889-8537(05)70391-6
Pharmacodynamic Interactions between Nifedipine and Atenolol
Rosenkranz, B., & Frölich, J. C. (1985) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1985.30.s1.22
Monitoring and transmission system of the health data of chronic patient at home-site
Yang, M. H., Hsieh, C.-W., Mao, C. W., & Young, M. S. (2003) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1999.803847
Home Blood Pressure Measurement - Epidemiology and Clinical Application
Niiranen, T. (2008) · STM:n Hallinnonalan avoin julkaisuarkisto (Julkari) · Cited by 2
Methoden und Modelle in der kardiovaskulären humanpharmakologischen Forschung
de Mey, C., Erb, K. A., Breithaupt, K., & Belz, G. G. (1993) · Konzepte in der Humanpharmakologi · doi:10.1007/978-3-642-50229-3_25
KURIYAMA, M. (1994) · Nippon Eiseigaku Zasshi (Japanese Journal of Hygiene) · doi:10.1265/jjh.49.816
[Home blood pressure measurement].
Niiranen, T., & Jula, A. (2009) · PubMed · Cited by 6
CURRICULUM: MEDICINA E PREVENZIONE
Muzzonigro, G., Corradetti, A., & Tranquilli, A. L. (2010)
Monitorización de la presión arterial por medios no invasivos
Gordón, F. D. B. D. L. Q., López, E. L., Gordón, M. D. L. Q., & Bustingorri, J. Z. (2004) · Elsevier eBooks · doi:10.1016/b978-84-8174-708-9.50008-6
Office Blood Pressure Measurement
Grim, C. E., & Grim, C. M. (2017) · Elsevier eBooks · doi:10.1016/b978-0-323-42973-3.00009-3
Estimation of Central Aortic Blood Pressure using a Noninvasive Automatic Blood Pressure Monitor
Shih, Y., Sun, Y.-J., Chen, C., Cheng, H., & Hu, W.-C. (2009) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-92841-6_122
Introduction to Chronobioengineering
Otsuka, K., Cornélissen, G., & Franz Halberg, A. (2016) · Springer eBooks · doi:10.1007/978-4-431-54631-3_8
Robust Estimation of Mean Arterial Pressure in Atrial Fibrillation Using Oscillometry
Tannous, M. (2014) · uO Research (University of Ottawa) · doi:10.20381/ruor-5036
Remembering Vigilance in the Age of Technology
Deshur, M. A., & Levine, W. C. (2017) · ASA Monitor · doi:10.1097/01.asm.0001075204.52437.56
The acute metabolic and hemodynamic effects of body inversion during rest and exercise
Ray, T. J. (1987) · VTechWorks (Virginia Tech)
Nath, S. K., Sengupta, A., Nath, S. K., Ghosh, S., Adhikary, P., Raha, A., Ray, S., Hossain, A., & Bhattacharya, J. (2017) · International Conference on Internet of Everything, Microwave Engineering, Communication and Networks (IEMECON) · doi:10.1109/iemecon.2017.8079599
Saugel, B., Scheeren, T., & Teboul, J. (2019) · Lessons from the ICU · doi:10.1007/978-3-319-69269-2_21
Ferronatto, J. V. B., Monteiro, E. R., Correia, B. S., Queiroga, L. B., & Becerra, J. R. H. (2018) · ACTA SCIENTIAE VETERINARIAE · doi:10.22456/1679-9216.89389
The practicalities of blood pressure measurement in children
Brennan, E. (2020) · Journal of Kidney Care · doi:10.12968/jokc.2020.5.1.13
Schmidt, V. G. (2015) · Elektronische Hochschulschriften der LMU München (Ludwig-Maximilians-Universität München) · doi:10.5282/edoc.17876
Nique, T. A. (1992) · Oral and Maxillofacial Surgery Clinics of North America · doi:10.1016/s1042-3699(20)30628-2
Solevåg, A. L., & Saugstad, O. D. (2021) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2021.05.004
Togawa, T. (2005) · Wiley eBooks · doi:10.1002/9783527619252.ch12
THEORETICAL STUDY OF DISCREPANCIES IN ESTIMATION OF MEAN BLOOD PRESSURE BY MAREY’S CRITERION
Raamat, R., Talts, J., & Jagomägi, K. (1999) · Proceedings of the Estonian Academy of Sciences Engineering · doi:10.3176/eng.1999.4.03 · Cited by 1
Blood Pressure: The History and Development of Monitoring Modalities
Cihelka, D. (2024) · Stroke Clinician · doi:10.59236/sc.v1i2.39
“24 NIBP devices are not recommended for use in patients with arrythmias that impact stroke volume, such as atrial fibrillation, 23,24,27 because of an erratic MAP with stroke volume variation that results in inaccurate device performance.”
BackgroundMethodJasim, M. S. M. (2024) · International Journal of Advanced Academic Studies · doi:10.33545/27068919.2024.v6.i6a.1194
de Oliveira, P. L. S. P., da Silva, B. V. S., de Moraes, D. G. R., Destêfani, A. C., & Destefani, V. C. (2024) · Revista Ibero-Americana de Humanidades, Ciências e Educação · doi:10.51891/rease.v10i8.15345
“This technique allows for continuous tracking of arterial pressure waveforms (3).”
Acierno, M. J. (2025) · Veterinary Clinics of North America Exotic Animal Practice · doi:10.1016/j.cvex.2025.07.004
Bensaïdane, M. R., & Coles, J. (2026) · Neurocritical Care · doi:10.1007/s12028-026-02526-y
“These identify mean arterial pressure (MAP) at peak cuff oscillations and then derive estimations of SBP and diastolic blood pressure (DBP) via proprietary algorithms [16–18].”
Noninvasive Arterial Pressure Monitoring during Anesthesia
Meidert, A. S., & Saugel, B. (2026) · Anesthesiology · doi:10.1097/aln.0000000000006070
Dolnimitsakul, S., Chaichalothorn, M., & Songchuen, N. (2026) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2026.06.049
Cuffless blood pressure monitoring: one step closer to validation
Picone, D. S., & Goupil, R. (2026) · Hypertension Research · doi:10.1038/s41440-026-02852-w
Trounce, J. Q., Stephenson, T. J., & Milner, A. D. (1992) · Springer eBooks · doi:10.1007/978-1-4471-3400-8_77
Metadata
- Authors
- Ramsey, M.
- Affiliations
- University of South Florida (US)
- Corresponding author
- Ramsey, Maynard
- Venue
- Medical and Biological Engineering and Computing
- Published
- 1979-01
- Volume
- 17
- Issue
- 1
- Pages
- 11-18
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W2909014974
- Semantic Scholar
- ba92a51d908a441e23b4b032943e695ac3e49a0c
- Cited by
- 287
- References
- 10
- Citations by year
- 2026: 4 · 2025: 5 · 2024: 9 · 2023: 4 · 2022: 5 · 2021: 5 · 2020: 7 · 2019: 4 · 2018: 8 · 2017: 8 · 2016: 3 · 2015: 7 · 2014: 5 · 2013: 5 · 2012: 7
- FWCI
- 8.03
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Medical & Biological Engineering & Computing (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Keywords
- mean arterial pressure, non-invasive blood pressure measurement, artefact rejection, cuff deflation, cuffless blood pressure measurement
- MeSH terms
- Adult, Aged, Blood Pressure Determination, Female, Humans, Male, Middle Aged, Monitoring, Physiologic, Oscillometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.