Noninvasive automatic determination of mean arterial pressure
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The maximum amplitude algorithm is a conventional method to estimate mean arterial pressure, which is the cuff pressure at the maximum amplitude of the oscillometric waveform envelope, corresponding with unloading the arterial wall and where the transmural pressure is zero [44, 51, 52].”
From Automated 'oscillometric' blood pressure measuring devices: how they work and what they measure (2022) · cites this paper as [51]
Citations
Cites
Mauck, G. W., Smith, C. R., Geddes, L. A., & Bourland, J. D. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138195 · Cited by 222
Comparison of Indirect and Direct Methods of Measuring Arterial Blood Pressure
VAN BERGEN, F. H., WEATHERHEAD, D. S., TRELOAR, A. E., DOBKIN, A. B., & BUCKLEY, J. J. (1954) · Circulation · doi:10.1161/01.cir.10.4.481 · Cited by 195
Blood Pressure Measurement in Shock
Cohn, J. N. (1967) · JAMA · doi:10.1001/jama.1967.03120130058009 · Cited by 138
(1969) · PubMed · Cited by 96
Effect of size of cuff bladder on accuracy of measurement of indirect blood pressure
Simpson, J. A., Jamieson, G., Dickhaus, D. W., & Grover, R. F. (1965) · American Heart Journal · doi:10.1016/0002-8703(65)90069-4 · Cited by 77
Indirect Mean Blood Pressure in the Anesthetized Pony
Geddes, L. A., Chaffee, V., Whistler, S. J., BOURLAND, J. D., & Tacker, W. A. (1977) · American Journal of Veterinary Research · doi:10.2460/ajvr.1977.38.12.2055 · Cited by 45
Transcutaneous Doppler Measurement of Blood Pressure
Kirby, R. R., Kemmerer, W. T., & Morgan, J. L. (1969) · Anesthesiology · doi:10.1097/00000542-196907000-00026 · Cited by 30
Collins, V. J., & Magora, F. (1963) · Anesthesia & Analgesia · doi:10.1213/00000539-196307000-00011 · Cited by 10
Buggs, H., Pe, J., Ls, G., et al. (1973) · PubMed · Cited by 3
Buggs, H., JOHNSON, P. E., Ls, G., Fb, B., & WETTACH, G. E. (1973) · Anesthesia & Analgesia · doi:10.1213/00000539-197309000-00023 · Cited by 3
Research works printed but not linked: 1
- Geddes, L. A., Moore, A. G., Garner, H., Rosborough, J., Ross, J. andAmend, J. (1970) The indirect measurement of mean blood pressure in the horse.The Southwestern Veterinarian,23, 289–294.
Cited by
Non‐invasive pulsatile arterial pressure and stroke volume changes from the human finger
Bogert, L. W. J., & van Lieshout, J. J. (2005) · Experimental Physiology · doi:10.1113/expphysiol.2005.030262 · Cited by 413
Characterization of the oscillometric method for measuring indirect blood pressure
Geddes, L. A., Voelz, M., Combs, C., Reiner, D., & Babbs, C. F. (1982) · Annals of Biomedical Engineering · doi:10.1007/bf02367308 · Cited by 340
Borow, K. M., & Newburger, J. W. (1982) · American Heart Journal · doi:10.1016/0002-8703(82)90403-3 · Cited by 310
Theory of the oscillometric maximum and the systolic and diastolic detection ratios
Drzewiecki, G., Hood, R., & Apple, H. (1994) · Annals of Biomedical Engineering · doi:10.1007/bf02368225 · Cited by 251
Arterial tonometry: Review and analysis
Drzewiecki, G. M., Melbin, J., & Noordergraaf, A. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90037-4 · Cited by 235
Oscillometric blood pressure: a review for clinicians
Alpert, B. S., Quinn, D., & Gallick, D. (2014) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2014.08.014 · Cited by 211
“…method and ratios for the determination of systolic and diastolic pressures were published throughout the 1970s and 1980s, including works by Ramsey (1979), Yelderman and Ream (1979), Kimble et al (1981), and Geddes (1982).7,10–12 In 1991, Geddes summarized that the ideal ratios for SBP and…”
Oscillometric Blood Pressure Estimation: Past, Present, and Future
Forouzanfar, M., Dajani, H. R., Groza, V. Z., Bolic, M., Rajan, S., & Batkin, I. (2015) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2015.2434215 · Cited by 196
“this assumption, the MAA approximates the MAP as the cuff pressure at which the OMWE attains a maximum [50], [61], [70], [71].”
BackgroundMethodInfluentialBlood Pressure Measurements in the Newborn
Nuntnarumit, P., Yang, W., & Bada-Ellzey, H. S. (1999) · Clinics in Perinatology · doi:10.1016/s0095-5108(18)30030-7 · Cited by 191
Techniques for Non-Invasive Monitoring of Arterial Blood Pressure
Meidert, A. S., & Saugel, B. (2018) · Frontiers in Medicine · doi:10.3389/fmed.2017.00231 · Cited by 177
“Mean arterial pressure corresponds to the maximum of oscillations (7); an algorithm applied to the change of oscillations sets systolic and diastolic arterial pressure values.”
MethodCuffless Blood Pressure Measurement
Mukkamala, R., Stergiou, G. S., & Avolio, A. P. (2022) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-110220-014644 · Cited by 180
Ursino, M., & Cristalli, C. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.508540 · Cited by 179
Oscillometric blood pressure measurement: progress and problems
van Montfrans, G. A. (2001) · Blood Pressure Monitoring · doi:10.1097/00126097-200112000-00004 · Cited by 175
Biological correlates of Reiki Touchsm healing
Wardell, D. W., & Engebretson, J. (2001) · Journal of Advanced Nursing · doi:10.1046/j.1365-2648.2001.01691.x · Cited by 161
Blood pressure monitoring: Automated oscillometric devices
Ramsey, M. (1991) · Journal of Clinical Monitoring · doi:10.1007/bf01617900 · Cited by 155
Self-citationSize at birth and blood pressure: cross sectional study in 8-11 year old children
Taylor, S. J., Whincup, P. H., Cook, D. G., Papacosta, O., & Walker, M. (1997) · BMJ · doi:10.1136/bmj.314.7079.475 · Cited by 152
The Effect of Animal-Assisted Therapy on Stress Responses in Hospitalized Children
Tsai, C.-C., Friedmann, E., & Thomas, S. A. (2010) · Anthrozoös · doi:10.2752/175303710x12750451258977 · Cited by 182
Baker, P. D., Westenskow, D. R., & Kück, K. (1997) · Medical & Biological Engineering & Computing · doi:10.1007/bf02530049 · Cited by 154
Yamakoshi, K.-I., Shimazu, H., & Togawa, T. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326616 · Cited by 139
Yamakoshi, K., Shimazu, H., Shibata, M., & Kamiya, A. (1982) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442797 · Cited by 129
Clinical evaluation of Dinamap 845 automated blood pressure recorder.
Silas, J. H., Barker, A. T., & Ramsay, L. E. (1980) · Heart · doi:10.1136/hrt.43.2.202 · Cited by 124
Smith, N. T., Wesseling, K. H., & Wit, B. (1985) · The Journal of Clinical Monitoring · doi:10.1007/bf02832685 · Cited by 123
A Consensus View on the Technique of Ambulatory Blood Pressure Monitoring
Staessen, J. A., Fagard, R. H., Thijs, L., & Amery, A. K. P. C. (1995) · Hypertension · doi:10.1161/01.hyp.26.6.912 · Cited by 120
Wittling, W. (1990) · Neuropsychologia · doi:10.1016/0028-3932(90)90072-v · Cited by 128
Do maternal and intrauterine factors influence blood pressure in childhood?
Whincup, P. H., Cook, D. G., & Papacosta, O. (1992) · Archives of Disease in Childhood · doi:10.1136/adc.67.12.1423 · Cited by 123
Delays in the diagnosis of oesophagogastric cancer: a consecutive case series
Martin, I. G., Young, S., Sue-Ling, H. M., & Johnston, D. A. (1997) · BMJ · doi:10.1136/bmj.314.7079.467 · Cited by 123
Haemodynamic changes following treatment of subclinical and overt hyperthyroidism
Faber, J., Wiinberg, N., Schifter, S., & Mehlsen, J. (2001) · European Journal of Endocrinology · doi:10.1530/eje.0.1450391 · Cited by 104
Yamakoshi, K., Shimazu, H., Shibata, M., & Kamiya, A. (1982) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442798 · Cited by 114
“OSCILLOMETRIC methods have been introduced recently for the indirect measurement of mean arterial pressure in humans (RAMSEY, 1979; YELDERMAN and REAM, 1979) and in animals (GEDDES et aL, 1977, 1980; LATSHAW et al.”
An assessment of the Dinamap 845
HUTTON, P., DYE, J., & PRYS‐ROBERTS, C. (1984) · Anaesthesia · doi:10.1111/j.1365-2044.1984.tb07240.x · Cited by 96
Stockton, D., Davies, T. W., Day, N., & McCann, J. (1997) · BMJ · doi:10.1136/bmj.314.7079.472 · Cited by 100
Automated 'oscillometric' blood pressure measuring devices: how they work and what they measure
Sharman, J. E., Tan, I., Stergiou, G. S., Lombardi, C., Saladini, F., Butlin, M., Padwal, R., Asayama, K., Avolio, A., Brady, T. M., et al. (2022) · Journal of Human Hypertension · doi:10.1038/s41371-022-00693-x · Cited by 84
“The maximum amplitude algorithm is a conventional method to estimate mean arterial pressure, which is the cuff pressure at the maximum amplitude of the oscillometric waveform envelope, corresponding with unloading the arterial wall and where the transmural pressure is zero [44, 51, 52].”
MethodFormulas to Explain Popular Oscillometric Blood Pressure Estimation Algorithms
Chandrasekhar, A., Yavarimanesh, M., Hahn, J.-O., Sung, S.-H., Chen, C.-H., Cheng, H.-M., & Mukkamala, R. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.01415 · Cited by 84
“…algorithm are defined as illustrated (see Glossary for text description). the factors that affect the accuracy of the maximum amplitude algorithm (Ramsey, 1979; Ursino and Cristalli, 1996; Baker et al., 1997; Raamat et al., 1999) and fixed ratio algorithm (Drzewiecki et al., 1994; Ursino and…”
The effect of status on blood pressure during verbal communication
Long, J. M., Lynch, J. J., Machiran, N. M., Thomas, S. A., & Malinow, K. L. (1982) · Journal of Behavioral Medicine · doi:10.1007/bf00844806 · Cited by 82
Hemodynamic Changes After Levothyroxine Treatment in Subclinical Hypothyroidism
Faber, J. O., Petersen, L. R., Wiinberg, N., Schifter, S., & Mehlsen, J. (2002) · Thyroid · doi:10.1089/10507250252949450 · Cited by 85
Blood pressure in very low birth weight infants in the first 70 days of life
Tan, K. L. (1988) · The Journal of Pediatrics · doi:10.1016/s0022-3476(88)80068-4 · Cited by 81
A Friendly Dog as Potential Moderator of Cardiovascular Response to Speech in Older Hypertensives
Friedmann, E., Thomas, S. A., Cook, L. K., Tsai, C.-C., & Picot, S. J. (2007) · Anthrozoös · doi:10.2752/089279307780216605 · Cited by 87
“The validity and reliability of the Dinamap 845X are well established (Ramesy 1979; Yelderman and Ream 1979) and the instrument has been used in many studies examining BP responses to stressors (Lynch et al. 1980; Lynch et al. 1981; Friedmann et al. 1982; Lynch et al. 1982; Friedmann et al. 1983;…”
Mobile wearable device for long term monitoring of vital signs
Klingeberg, T., & Schilling, M. (2012) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2011.12.009 · Cited by 87
Perception of Animals and Cardiovascular Responses During Verbalization With an Animal Present
Friedmann, E., Locker, B. Z., & Lockwood, R. (1993) · Anthrozoös · doi:10.2752/089279393787002303 · Cited by 71
Whincup, P. H., Bruce, N., Cook, D. G., & Shaper, A. G. (1992) · Journal of Epidemiology & Community Health · doi:10.1136/jech.46.2.164 · Cited by 71
Meidert, A. S., Nold, J. S., Hornung, R., Paulus, A. C., Zwißler, B., & Czerner, S. F. A. (2017) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000000690 · Cited by 69
Whincup, P. H., Cook, D. G., Adshead, F., Taylor, S. J., Papacosta, O., Walker, M., & Wilson, V. (1996) · BMJ · doi:10.1136/bmj.313.7049.79 · Cited by 69
Fellner, S. K., Lang, R. M., Neumann, A., Spencer, K. T., Bushinsky, D. A., & Borow, K. M. (1989) · Hypertension · doi:10.1161/01.hyp.13.3.213 · Cited by 62
Rutten, A. J., Ilsley, A. H., Skowronski, G. A., & Runciman, W. B. (1986) · Anaesthesia and Intensive Care · doi:10.1177/0310057x8601400113 · Cited by 62
Home relaxation practice in hypertension treatment: Objective assessment and compliance induction.
Hoelscher, T. J., Lichstein, K. L., & Rosenthal, T. L. (1986) · Journal of Consulting and Clinical Psychology · doi:10.1037//0022-006x.54.2.217 · Cited by 60
Crisp-BP: continuous wrist PPG-based blood pressure measurement
Cao, Y., Chen, H., Li, F., & Wang, Y. (2021) · ACM Annual International Conference on Mobile Computing and Networking (MobiCom) · doi:10.1145/3447993.3483241 · Cited by 68
“is to block arterial blood flow with a cuff and determine the ABP based on Korotkoff sounds [54] or oscillometric method [44] in the discharge process.”
MethodFaxelius, G., Lagercrantz, H., & Yao, A. C. (1984) · The Journal of Pediatrics · doi:10.1016/s0022-3476(84)80381-9 · Cited by 57
Blood pressure in the very low birth weight neonate
Engle, W. D. (2001) · Early Human Development · doi:10.1016/s0378-3782(01)00124-4 · Cited by 56
Amoore, J. N., Lemesre, Y., Murray, I. C., Mieke, S., King, S. T., Smith, F. E., & Murray, A. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e3282f06ec7 · Cited by 56
Drzewiecki, G. M., & Pilla, J. J. (1998) · Annals of Biomedical Engineering · doi:10.1114/1.130 · Cited by 56
Felodipine ? A new vasodilator, in addition to ?-receptor blockade in hypertension
Elmfeldt, D., & Hedner, T. (1983) · European Journal of Clinical Pharmacology · doi:10.1007/bf00542340 · Cited by 54
Acierno, M. J., Seaton, D., Mitchell, M. A., & da Cunha, A. F. (2010) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.237.4.402 · Cited by 52
The relative accuracies of two automated noninvasive arterial pressure measurement devices
Gorback, M. S., Quill, T. J., & Lavine, M. (1991) · The Journal of Clinical Monitoring · doi:10.1007/bf01617893 · Cited by 52
Runcie, C. J., Reeve, W., Reidy, J., & Dougall, J. (1990) · Anaesthesia · doi:10.1111/j.1365-2044.1990.tb14393.x · Cited by 51
Blood pressure measurement: current practice and future trends.
O'Brien, E. T., Fitzgerald, D. J., & O'MALLEY, K. (1985) · BMJ · doi:10.1136/bmj.290.6470.729 · Cited by 51
A Preliminary Evaluation of the Mean Arterial Pressure as Measured by Cuff Oscillometry
Smulyan, H., Sheehe, P. R., & Safar, M. E. (2008) · American Journal of Hypertension · doi:10.1038/ajh.2007.45 · Cited by 46
Yamakoshi, K.-I., Kamiya, A., Shimazu, H., Ito, H., & Togawa, T. (1983) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442380 · Cited by 52
Placental Circulation, Fetal Growth, and Stiffness of the Abdominal Aorta in Newborn Infants
Akira, M., & Saburi, Y. (2006) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2005.06.044 · Cited by 43
Treatmetn of mild to moderate hypertension with or without the converting enzyme inhibitor enalapril
Sassano, P., Châtellier, G., Billaud, E. M., Alhenc‐Gelas, F., Corvol, P. L., & Ménard, J. (1987) · The American Journal of Medicine · doi:10.1016/0002-9343(87)90690-5 · Cited by 46
Benmira, A. M., Pérez‐Martin, A., Schuster, I., Aichoun, I., Coudray, S., Bereksi-Reguig, F., & Dauzat, M. (2015) · Expert Review of Medical Devices · doi:10.1586/17434440.2016.1128821 · Cited by 48
“Automatic devices were later introduced and tested.[31] When looking at the mercury column or the needle on the dial of an aneroid sphygmomanometer, one can”
BackgroundByfield, R., Miller, M., Miles, J., Guidoboni, G., & Lin, J. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3134890 · Cited by 45
Chang, J. J. (2003) · American Journal of Epidemiology · doi:10.1093/aje/kwg274 · Cited by 39
Ankle blood pressure measurement, an acceptable alternative to arm measurements
Block, F. E., & Schulte, G. T. (1996) · International journal of clinical monitoring and computing · doi:10.1023/a:1016997232542 · Cited by 37
Automatic blood pressure monitors A clinical evaluation of five models in adults
JOHNSON, C. J. H., & KERR, J. H. (1985) · Anaesthesia · doi:10.1111/j.1365-2044.1985.tb10851.x · Cited by 38
Zheng, D., Amoore, J., Mieke, S., & Murray, A. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0694-y · Cited by 39
“These changes are caused by the pulse radiating down the artery producing pressure changes in the cuff, which are expected to be greatest at MAP [18].”
BackgroundMethodAccuracy of four indirect methods of blood pressure measurement, with hemodynamic correlations
Gravlee, G. P., & Brockschmidt, J. K. (1990) · Journal of Clinical Monitoring and Computing · doi:10.1007/bf02842488 · Cited by 35
“Some studies suggest a consistent direction of measurement error within single patients, supporting accurate diagnosis of blood pressure changes despite consistent overestimation or underestimation of arterial blood pressure [6,22-34,35].”
BackgroundResultShort‐term effects of felodipine, a new dihydropyridine, in hypertension.
Andersson, O., Bengtsson, C., Elmfeldt, D., Haglund, K., Hedner, T., Seideman, P., Kh, S., Stromgren, E., Åberg, H., & Östman, J. (1984) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.1984.tb02340.x · Cited by 35
Amoore, J. N., Vacher, E., Murray, I. C., Mieke, S., King, S. T., Smith, F. E., & Murray, A. (2007) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e32826fb773 · Cited by 34
History and evolution of blood pressure measurement
Noh, S. A., Kim, H.-S., Kang, S., Yoon, C., Youn, T., & Chae, I. (2024) · Clinical Hypertension · doi:10.1186/s40885-024-00268-7 · Cited by 44
“Dinamap (an acronym for “device for indirect noninvasive mean arterial pres-sure”) was the first commercially produced automatic oscillometric BP monitor, which was marketed Applied Medical Research in 1976 [38, 39].”
Methodda Cunha, A. F., Ramos, S. J., Domingues, M., Beaufrère, H., Shelby, A. M., Stout, R. W., & Acierno, M. J. (2015) · Veterinary Anaesthesia and Analgesia · doi:10.1111/vaa.12312 · Cited by 33
Effects of Elevated Female Sex Steroids on Ethanol and Acetaldehyde Metabolism in Humans
Wilkinson, C. J., & Zeiner, A. R. (1984) · Alcoholism Clinical and Experimental Research · doi:10.1111/j.1530-0277.1984.tb05679.x · Cited by 34
Amoore, J. (2006) · Blood Pressure Monitoring · doi:10.1097/01.mbp.0000217999.04592.7c · Cited by 39
Gevers, M., van Genderingen, H. R., Lafeber, H. N., & Hack, W. W. M. (1996) · Intensive Care Medicine · doi:10.1007/bf01712244 · Cited by 32
“performed comparing oscillometric and invasive methods in adults [27, 31, 32], in children [-15, 33] and in neonates [-15-23].”
MethodBlood Pressure in Full-term Healthy Neonates
Tan, K. L. (1987) · Clinical Pediatrics · doi:10.1177/000992288702600103 · Cited by 32
Pessenhofer, H. (1986) · Basic Research in Cardiology · doi:10.1007/bf01907432 · Cited by 32
Jorgensen, R. S., Gelling, P. D., & Kliner, L. (1992) · Health Psychology · doi:10.1037/0278-6133.11.6.403 · Cited by 31
Noninvasive blood pressure pulse detection and blood pressure determination
Sorvoja, H. S. S. (2006) · Cited by 40
Acierno, M. J., Fauth, E., Mitchell, M. A., & da Cunha, A. F. (2013) · Journal of Veterinary Emergency and Critical Care · doi:10.1111/vec.12011 · Cited by 29
Noninvasive Arterial Blood Pressure and Mechanics
Drzewiecki, G. M. (1999) · The electrical engineering handbook/Electrical engineering handbook series/Electrical engineering handbook · doi:10.1201/9781420049510.ch71 · Cited by 28
Whincup, P. H., Cook, D. G., Papacosta, O., & Walker, M. (1992) · Journal of Epidemiology & Community Health · doi:10.1136/jech.46.4.396 · Cited by 26
Aaslid, R., & Brubakk, A. O. (1981) · Circulation · doi:10.1161/01.cir.64.4.753 · Cited by 26
Noninvasive Blood Pressure Monitoring via a Flexible and Wearable Piezoresistive Sensor
Bijender, Kumar, S., Soni, A., Yadav, R., Singh, S. P., & Kumar, A. (2024) · ACS Omega · doi:10.1021/acsomega.3c04786 · Cited by 28
“18,19 In the present study, we also used the MAA to calculate the SBP and DBP values, and a range of specific ratios for systolic (from 0.45 to 0.60) and diastolic (from 0.65 to 0.80) was taken as provided in the literature.”
MethodInfluentialKhaw, K. S., Kee, W. D. N., & Lee, S. W. Y. (2006) · Fetal and Maternal Medicine Review · doi:10.1017/s0965539506001756 · Cited by 26
Amoore, J., Vacher, E., Murray, I. C., Mieke, S., King, S. T., Smith, F. E., & Murray, A. (2006) · Blood Pressure Monitoring · doi:10.1097/01.mbp.0000200482.72410.e2 · Cited by 25
Oscillometric Waveform Evaluation for Blood Pressure Devices
Kumar, S., Yadav, S., & Kumar, A. (2022) · Biomedical Engineering Advances · doi:10.1016/j.bea.2022.100046 · Cited by 26
NONINVASIVE BLOOD PRESSURE MEASUREMENT METHODS
Sorvoja, H. S. S., & Myllylä, R. A. (2006) · Molecular and Quantum Acoustics · Cited by 40
Ng, K.-G., & Small, C. F. (1993) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(93)90003-h · Cited by 25
Noninvasive Blood Pressure Monitoring
Dobbin, K. R. (2002) · Critical Care Nurse · doi:10.4037/ccn2002.22.2.123 · Cited by 24
Blood pressure and heart rate changes in children when they read aloud in school.
Thomas, S. A., Lynch, J. J., Friedmann, E., Suginohara, M., Hall, P. S., & Peterson, C. (1984) · Europe PMC (PubMed Central) · Cited by 24
Kumar, S., Yadav, S., & Kumar, A. (2024) · Sensors & Diagnostics · doi:10.1039/d3sd00201b · Cited by 29
Hypnotic Susceptibility, Mood State, and Cardiovascular Reactivity
Harris, R. M., Porges, S. W., Clemenson, M. E., & Vincenz, L. M. (1993) · American Journal of Clinical Hypnosis · doi:10.1080/00029157.1993.10403035 · Cited by 23
Multivariate classification of systemic vascular resistance using photoplethysmography
Lee, Q. Y., Chan, G. S. H., Redmond, S. J., Middleton, P. M., Steel, E., Malouf, P. J., Critoph, C., Flynn, G. M., O’Lone, E., & Lovell, N. H. (2011) · Physiological Measurement · doi:10.1088/0967-3334/32/8/008 · Cited by 23
“These measurements are usually obtained invasively from the patients and typically involve catheterization, although MAP can also be measured using non-invasive techniques (using inflatable cuffs, as used by the oscillometric method (Ramsey 1979)).”
Uncovering a hidden language: The effects of listening and talking on blood pressure and heart rate
Liehr, P. R. (1992) · Archives of Psychiatric Nursing · doi:10.1016/0883-9417(92)90042-h · Cited by 23
Yamakoshi, K.-I., & Kamiya, A. (1987) · Springer eBooks · doi:10.1007/978-94-009-3361-3_12 · Cited by 23
Geographical variations in blood pressure in British men and women
Bruce, N., Cook, D. G., Shaper, A. G., & Thomson, A. G. (1990) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(90)90124-8 · Cited by 23
PELLEGRINI‐CALIUMI, G., AGOSTINO, R., Nodari, S., Maffei, G., Moretti, C., & Bucci, G. (1982) · Acta Paediatrica · doi:10.1111/j.1651-2227.1982.tb09521.x · Cited by 23
Effectiveness and cost efficiency of interventions in health promotion
Pruitt, R. H. (1992) · Journal of Advanced Nursing · doi:10.1111/j.1365-2648.1992.tb02020.x · Cited by 23
Is oscillometric ankle pressure reliable in leg vascular disease?
Jönsson, B., Lindberg, L., Skau, T., & Thulesius, O. (2001) · Clinical Physiology · doi:10.1046/j.1365-2281.2001.00314.x · Cited by 21
Photoplethysmography in noninvasive blood pressure monitoring
Mukkamala, R., Hahn, J., & Chandrasekhar, A. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-823374-0.00010-4 · Cited by 26
Aakhus, S., Torp, H. G., Haugland, T., & Hatle, L. K. (1993) · Clinical Physiology · doi:10.1111/j.1475-097x.1993.tb00473.x · Cited by 21
Automated blood pressure measurements in laboring women: Are they reliable?
Marx, G. F., Schwalbe, S. S., Cho, E., & Whitty, J. E. (1993) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(12)90822-4 · Cited by 21
Oscillometric and intra-arterial blood pressure measurements in the neonate: a comparison of methods
Lui, K., DOYLE, P. E., & Buchanan, N. (1982) · Journal of Paediatrics and Child Health · doi:10.1111/j.1440-1754.1982.tb01975.x · Cited by 20
Metadata
- Authors
- Ramsey, M.
- Affiliations
- University of South Florida (US)
- Corresponding author
- Ramsey, Maynard
- Venue
- Medical and Biological Engineering and Computing
- Published
- 1979-01
- Volume
- 17
- Issue
- 1
- Pages
- 11-18
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W2909014974
- Semantic Scholar
- ba92a51d908a441e23b4b032943e695ac3e49a0c
- Cited by
- 287
- References
- 10
- Citations by year
- 2026: 4 · 2025: 5 · 2024: 9 · 2023: 4 · 2022: 5 · 2021: 5 · 2020: 7 · 2019: 4 · 2018: 8 · 2017: 8 · 2016: 3 · 2015: 7 · 2014: 5 · 2013: 5 · 2012: 7
- FWCI
- 8.03
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Medical & Biological Engineering & Computing (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Keywords
- mean arterial pressure, non-invasive blood pressure measurement, artefact rejection, cuff deflation, cuffless blood pressure measurement
- MeSH terms
- Adult, Aged, Blood Pressure Determination, Female, Humans, Male, Middle Aged, Monitoring, Physiologic, Oscillometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.