Theoretical study on the effect of sensor contact force on pulse transit time

Xiao-Fei Teng, Yuan-Ting Zhang·2007·IEEE Transactions on Biomedical Engineering

Abstract

Pulse transit time (PTT) has been widely used for noninvasive examination of the arterial viscoelastic properties, such as elasticity, compliance, and stiffness of the vessel walls. PTT is usually determined as the time interval between the peak of the electrocardiogram R wave and the foot of the photoplethysmogram (PPG). However, it was observed that the PPG is affected by the applied contact force between the photoplethysmographic sensor and the measurement site, e.g., finger. In this study, the nonlinear biomechanical properties of the finger arterial wall were considered when investigating the changes in PTT with varying contact force. Emphasis was placed on the changes in the shape of the arterial wall pressure-volume curve. The simulation results indicated that at positive transmural pressure, PTT increased with the applied contact force, reaching the maximum at zero transmural pressure and remaining at a constant level at negative transmural pressure. The theoretical analysis was further verified by the experiments carried out on thirty young subjects and six elderly subjects using twelve discrete levels of contact force.

Integrity signals

Registry

Crossref · 10.1109/tbme.2007.900815

Cites

51 of 51 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • With low applied external pressure from the sensor, the waveform exhibits lower SNR with a low AC amplitude primarily because of a longer optical path length through the tissue and a lower reflectance of photons due to high tissue absorption.

    “With a low applied external pressure from the sensor, the waveform exhibits lower SNR with a low AC amplitude primarily because of a longer optical path length through the tissue and a lower reflectance of photons due to high tissue absorption [203].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Teng, X.-F., & Zhang, Y.-T.
Affiliations
Chinese University of Hong Kong (HK)
Venue
IEEE Transactions on Biomedical Engineering
Published
2007-08
Volume
54
Issue
8
Pages
1490-1498
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2105257471
Cited by
94
References
51
Citations by year
2026: 2 · 2025: 1 · 2024: 7 · 2023: 10 · 2022: 2 · 2021: 4 · 2020: 6 · 2019: 5 · 2018: 7 · 2017: 8 · 2016: 7 · 2015: 13 · 2014: 9 · 2013: 3 · 2012: 2
FWCI
1.91
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
  • Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
Keywords
pulse transit time, photoplethysmography, arterial viscoelasticity, pressure-volume relationship, transmural pressure, arterial stiffness, arterial compliance, arterial elasticity
MeSH terms
Adult, Computer Simulation, Female, Fingers, Humans, Male, Middle Aged, Models, Cardiovascular, Pulsatile Flow, Sensitivity and Specificity, Stress, Mechanical, Reproducibility of Results, Artifacts, Photoplethysmography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review