Elastography: Imaging the elastic properties of soft tissues with ultrasound
The DOI matches its Crossref record; 53 of the 54 references it cites were found in a registry or an index.
Abstract
Elastography is a method that can ultimately generate several new kinds of images, called elastograms. As such, all the properties of elastograms are different from the familiar properties of sonograms. While sonograms convey information related to the local acoustic backscatter energy from tissue components, elastograms relate to its local strains, Young's moduli or Poisson's ratios. In general, these elasticity parameters are not directly correlated with sonographic parameters, i.e. elastography conveys new information about internal tissue structure and behavior under load that is not otherwise obtainable. In this paper we summarize our work in the field of elastography over the past decade. We present some relevant background material from the field of biomechanics. We then discuss the basic principles and limitations that are involved in the production of elastograms of biological tissues. Results from biological tissues in vitro and in vivo are shown to demonstrate this point. We conclude with some observations regarding the potential of elastography for medical diagnosis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Self-citationElastic Moduli of Breast and Prostate Tissues under Compression
Krouskop, T. A., Wheeler, T. M., Kallel, F., Garra, B. S., & Hall, T. (1998) · Ultrasonic Imaging · doi:10.1177/016173469802000403 · Cited by 1,703
Self-citationStrength of biological materials
Yamada, H., & Evans, F. G. (1970) · Cited by 1,136
Elastography of breast lesions: initial clinical results.
Garra, B. S., Cespedes, E. I., Ophir, J., Spratt, S. R., Zuurbier, R. A., Magnant, C. M., & Pennanen, M. F. (1997) · Radiology · doi:10.1148/radiology.202.1.8988195 · Cited by 940
Self-citationElastography: Ultrasonic estimation and imaging of the elastic properties of tissues
Ophir, J., Alam, S. K., Garra, B., Kallel, F., Konofagou, E., Krouskop, T., & Varghese, T. (1999) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411991534933 · Cited by 784
Self-citationInternal displacement and strain imaging using ultrasonic speckle tracking
O'Donnell, M., Skovoroda, A. R., Shapo, B. M., & Emelianov, S. Y. (1994) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.285465 · Cited by 699
Elasticity : theory and applications
Saada, A. S. (1993) · Cited by 676
Strength of biological materials
Roberts, V. L. (1971) · Journal of Biomechanics · doi:10.1016/0021-9290(71)90027-3 · Cited by 566
Imaging of the elastic properties of tissue—A review
Gao, L., Parker, K. J., Lerner, R. M., & Levinson, S. F. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(96)00120-2 · Cited by 514
Research works printed but not linked: 4
- Anderson, WAD, Pathology, C.V. Mosby Co., St. Louis, 1953.
- Fung YC: Biomechanical properties of living tissues, Ch. 7, Springer Verlag, NY, 1981.
- Lerner RM, Parker KJ: Sono-elasticity in ultrasonic tissue characterization and echographic imaging. Proc. 7th Eur. Comm. Workshop, J.M. Thijssen, Ed., Nijmegen, The Netherlands, 1987.
- Malinauskas M, Krouskop TA, Barry P A: Noninvasive measurement of the elastic modulus of tissue in the aboveknee amputation stump.J Rehabil Res Dev 1989;26: 45–52.
Cited by
Bamber, J., Cosgrove, D., Dietrich, C., Fromageau, J., Bojunga, J., Calliada, F., Cantisani, V., Correas, J.-M., D'Onofrio, M., Drakonaki, E., et al. (2013) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0033-1335205 · Cited by 1,198
Medical ultrasound: imaging of soft tissue strain and elasticity
Wells, P. N. T., & Liang, H.-D. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0054 · Cited by 538
Optical coherence elastography in ophthalmology
Kirby, M. A., Pelivanov, I., Song, S., Ambrozinski, Ł., Yoon, S. J., Gao, L., Li, D., Shen, T. T., Wang, R. K., & O’Donnell, M. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.12.121720 · Cited by 228
Modeling of Tool-Tissue Interactions for Computer-Based Surgical Simulation: A Literature Review
Misra, S., Ramesh, K. T., & Okamura, A. M. (2008) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.17.5.463 · Cited by 219
Motion Estimation in Ultrasound Images Using Time Domain Cross Correlation With Prior Estimates
Zahiri-Azar, R., & Salcudean, S. E. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.881780 · Cited by 214
Sonoelastography: Musculoskeletal Applications
Klauser, A. S., Miyamoto, H., Bellmann-Weiler, R., Feuchtner, G. M., Wick, M. C., & Jaschke, W. R. (2014) · Radiology · doi:10.1148/radiol.14121765 · Cited by 211
Advances in mechanics of hierarchical composite materials
Chen, Y., Ma, Y., Yin, Q., Pan, F., Cui, C., Zhang, Z., & Liu, B. (2021) · Composites Science and Technology · doi:10.1016/j.compscitech.2021.108970 · Cited by 205
Shear Wave Ultrasound Elastography of the Prostate: Initial Results
Barr, R. G., Memo, R., & Schaub, C. R. (2012) · Ultrasound Quarterly · doi:10.1097/ruq.0b013e318249f594 · Cited by 195
Linear and nonlinear elasticity imaging of soft tissuein vivo: demonstration of feasibility
Oberai, A. A., Gokhale, N. H., Goenezen, S., Barbone, P. E., Hall, T. J., Sommer, A. M., & Jiang, J. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/5/006 · Cited by 162
Ultrasound image segmentation and tissue characterization
Noble, J. A. (2010) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/09544119jeim604 · Cited by 159
A Tissue Phantom for Visualization and Measurement of Ultrasound-Induced Cavitation Damage
Maxwell, A. D., Wang, T.-Y., Yuan, L., Duryea, A. P., Xu, Z., & Cain, C. A. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.08.023 · Cited by 159
Optical micro-scale mapping of dynamic biomechanical tissue properties
Liang, X., Oldenburg, A. L., Crecea, V., Chaney, E. J., & Boppart, S. A. (2008) · Optics Express · doi:10.1364/oe.16.011052 · Cited by 148
Ultrasound Elastography – Review of Techniques and its Clinical Applications
Zaleska–Dorobisz, U., Kaczorowski, K., Pawluś, A., Puchalska, A., & Inglot, M. (2014) · Advances in Clinical and Experimental Medicine · doi:10.17219/acem/26301 · Cited by 136
Song, S., Huang, Z., Nguyen, T.-M., Wong, E. Y. M., Arnal, B., O’Donnell, M., & Wang, R. K. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.12.121509 · Cited by 128
Havre, R. F., Elde, E., Gilja, O. H., Ødegaard, S., Eide, G. E., Matre, K., & Nesje, L. B. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.03.009 · Cited by 127
Ultrasound-Guided Robot for Flexible Needle Steering
Neubach, Z., & Shoham, M. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2030169 · Cited by 126
Magnetomotive nanoparticle transducers for optical rheology of viscoelastic materials
Crecea, V., Oldenburg, A. L., Liang, X., Ralston, T. S., & Boppart, S. A. (2009) · Optics Express · doi:10.1364/oe.17.023114 · Cited by 113
Zheng, Y., Chen, S., Tan, W., Kinnick, R. R., & Greenleaf, J. F. (2007) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2007.243 · Cited by 112
Sonoelastography in the musculoskeletal system: Current role and future directions
Winn, N., Lalam, R. K., & Cassar‐Pullicino, V. N. (2016) · World Journal of Radiology · doi:10.4329/wjr.v8.i11.868 · Cited by 108
Tissue property estimation and graphical display for teleoperated robot-assisted surgery
YAMAMOTO, T., Vágvölgyi, B., Balaji, K., Whitcomb, L. L., & Okamura, A. M. (2009) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2009.5152674 · Cited by 107
Konofagou, E. E. (2003) · Ultrasonics · doi:10.1016/j.ultras.2003.11.010 · Cited by 98
Self-citationFascia Mobility, Proprioception, and Myofascial Pain.
Langevin, H. M. (2021) · Life · doi:10.3390/life11070668 · Cited by 97
Glozman, T., & Azhari, H. (2010) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2010.29.3.387 · Cited by 97
Poisson ratio can play a crucial role in mechanical properties of biocomposites
Liu, B., Zhang, L., & Gao, H. (2006) · Mechanics of Materials · doi:10.1016/j.mechmat.2006.02.002 · Cited by 93
Falou, O., Naini, A. S., Prematilake, S., Sofroni, E., Papanicolau, N., Iradji, S., Jahedmotlagh, Z., Lemon-Wong, S., Pignol, J., Rakovitch, E., et al. (2013) · Translational Oncology · doi:10.1593/tlo.12412 · Cited by 87
Li, P., Shen, T. T., Johnstone, M., & Wang, R. K. (2013) · Biomedical Optics Express · doi:10.1364/boe.4.002051 · Cited by 87
Medical diagnostic applications and sources
Whittingham, T. A. (2006) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2006.07.004 · Cited by 82
Mechanical mapping with chemical specificity by confocal Brillouin and Raman microscopy
Palombo, F., Madami, M., Stone, N., & Fioretto, D. (2014) · The Analyst · doi:10.1039/c3an02168h · Cited by 76
Value of ultrasound shear wave elastography in the diagnosis of adenomyosis
Acar, S., Millar, E., Mitkova, M. D., & Mitkov, V. V. (2016) · Ultrasound · doi:10.1177/1742271x16673677 · Cited by 76
The importance of organ geometry and boundary constraints for planning of medical interventions
Misra, S., Macura, K. J., Ramesh, K. T., & Okamura, A. M. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.08.002 · Cited by 75
Zaitsev, V. Y., Matveyev, A. L., Matveev, L. A., Gelikonov, G. V., Gelikonov, V. M., & Vitkin, I. A. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.7.075006 · Cited by 69
GLUENet: Ultrasound Elastography Using Convolutional Neural Network
Kibria, M. G., & Rivaz, H. (2018) · Lecture notes in computer science · doi:10.1007/978-3-030-01045-4_3 · Cited by 65
Karpiouk, A. B., Aglyamov, S. R., Ilinskii, Y. A., Zabolotskaya, E. A., & Emelianov, S. (2009) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1326 · Cited by 63
Sahebjavaher, R. S., Nir, G., Honarvar, M., Gagnon, L. O., Ischia, J. J., Jones, E. C., Chang, S. D., Fazli, L., Goldenberg, S. L., Rohling, R. N., et al. (2014) · NMR in Biomedicine · doi:10.1002/nbm.3218 · Cited by 61
Phase-based block matching applied to motion estimation with unconventional beamforming strategies
Basarab, A., Gueth, P., Liebgott, H., & Delachartre, P. (2009) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1127 · Cited by 61
Karimi, A., Sera, T., Susumu, K. U. D. O., & Navidbakhsh, M. (2016) · Artery Research · doi:10.1016/j.artres.2016.08.002 · Cited by 61
Sayed, A. M., Layne, G. P., Abraham, J., & Mukdadi, O. M. (2013) · Ultrasonics · doi:10.1016/j.ultras.2013.01.005 · Cited by 60
Hai, P., Yao, J., Li, G., Li, C., & Wang, L. V. (2016) · Optics Letters · doi:10.1364/ol.41.000725 · Cited by 60
Azar, R. Z., Göksel, O., & Salcudean, S. E. (2010) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2010.1708 · Cited by 60
Zhang, J., Raghunathan, R., Rippy, J. R., Wu, C., Finnell, R. H., Larin, K. V., & Scarcelli, G. (2018) · Birth Defects Research · doi:10.1002/bdr2.1389 · Cited by 59
Photoacoustic elastography imaging: a review
Singh, M. S., & Thomas, A. (2019) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.4.040902 · Cited by 58
Accuracy of real-time shear wave elastography in staging hepatic fibrosis: a meta-analysis
Fu, J., Wu, B., Wu, H., Lin, F., & Deng, W. (2020) · BMC Medical Imaging · doi:10.1186/s12880-020-0414-5 · Cited by 56
Monitoring Breast Cancer Response to Neoadjuvant Chemotherapy Using Ultrasound Strain Elastography
Fernandes, J. P., Sannachi, L., Tran, W. T., Koven, A. B., Watkins, E. J., Hadizad, F., Gandhi, S., Wright, F. C., Curpen, B. N., Kaffas, A. E., et al. (2019) · Translational Oncology · doi:10.1016/j.tranon.2019.05.004 · Cited by 54
Machine learning in medical imaging
Kumar, A., Bi, L., Kim, J., & Feng, D. D. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-816034-3.00005-5 · Cited by 53
Ansari, M. Y., Qaraqe, M., Righetti, R., Serpedin, E., & Qaraqe, K. A. (2023) · Frontiers in Oncology · doi:10.3389/fonc.2023.1282536 · Cited by 52
Self-citationUltrasonic strain imaging and reconstructive elastography for biological tissue
Khaled, W., Reichling, S., Bruhns, O. T., & Ermert, H. (2006) · Ultrasonics · doi:10.1016/j.ultras.2006.06.007 · Cited by 51
Noninvasive Blood Pressure Estimation Using Ultrasound and Simple Finite Element Models
Zakrzewski, A. M., & Anthony, B. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2714666 · Cited by 51
Wex, C. B. A., Fröhlich, M., Brandstädter, K., Bruns, C. J., & Stoll, A. (2014) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2014.10.013 · Cited by 50
Utility of Real-Time Shear Wave Elastography in the Assessment of Testicular Torsion
Sun, Z., Xie, M., Xiang, F., Song, Y., Cheng, Y., Zhang, Y., Ramdhany, S., & Wang, J. (2015) · PLoS ONE · doi:10.1371/journal.pone.0138523 · Cited by 50
Harmonic Motion Imaging of Pancreatic Tumor Stiffness Indicates Disease State and Treatment Response
Payen, T., Oberstein, P. E., Saharkhiz, N., Palermo, C. F., Sastra, S. A., Han, Y., Nabavizadeh, A., Sagalovskiy, I. R., Orelli, B., Rosario, V. L., et al. (2019) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-18-3669 · Cited by 49
Self-citationDetermining the Acoustic Properties of the Lens Using A High-Frequency Ultrasonic Needle Transducer
Huang, C., Zhou, Q., Ameri, H., Wu, D. W., Sun, L., Wang, S.-H., Humayun, M. S., & Shung, K. K. (2007) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2007.06.004 · Cited by 49
Needle Insertion Parameter Optimization for Brachytherapy
Dehghan, E., & Salcudean, S. E. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.2011415 · Cited by 47
Does group velocity always reflect elastic modulus in shear wave elastography?
Pelivanov, I., Gao, L., Pitre, J. J., Kirby, M. A., Song, S., Li, D. S., Shen, T. T., Wang, R. K., & O’Donnell, M. (2019) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.7.076003 · Cited by 47
Jeon, S., Lee, G., Lee, S., Kim, H., Yu, D., & Choi, J. (2015) · Veterinary Radiology & Ultrasound · doi:10.1111/vru.12238 · Cited by 45
Zaitsev, V. Y., Matveev, L. A., Matveyev, A. L., Gelikonov, G. V., & Gelikonov, V. M. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.2.021107 · Cited by 44
Kim, W., Ferguson, V. L., Borden, M. A., & Neu, C. P. (2016) · Annals of Biomedical Engineering · doi:10.1007/s10439-015-1542-x · Cited by 43
Evaluation of Lens Hardness in Cataract Surgery using High-Frequency Ultrasonic Parameters in Vitro
Huang, C., Ameri, H., DeBoer, C. M. T., Rowley, A. P., Xu, X., Sun, L., Wang, S.-H., Humayun, M. S., & Shung, K. K. (2007) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2007.05.002 · Cited by 42
Needle-tissue interaction modeling using ultrasound-based motion estimation: Phantom study
Dehghan, E., Wen, X., Zahiri-Azar, R., Marchal, M., & Salcudean, S. E. (2008) · Computer Aided Surgery · doi:10.3109/10929080802383173 · Cited by 40
Ultrasound: Medical Imaging and Beyond (An Invited Review)
Azhari, H. (2012) · Current Pharmaceutical Biotechnology · doi:10.2174/138920112802502033 · Cited by 39
Silva, M. E., Brandão, S., Parente, M., Mascarenhas, T., & Jorge, R. N. (2016) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411916630571 · Cited by 39
Intra-operative tumour localisation in robot-assisted minimally invasive surgery: A review
Li, M., Liu, H., Jiang, A., Seneviratne, L. D., Dasgupta, P., Althoefer, K. A., & Wurdemann, H. A. (2014) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411914533679 · Cited by 38
High frequency ultrasonic characterization of human vocal fold tissue
Huang, C., Sun, L., Dailey, S. H., Wang, S.-H., & Shung, K. K. (2007) · The Journal of the Acoustical Society of America · doi:10.1121/1.2756759 · Cited by 38
A correlation-stability approach to elasticity mapping in optical coherence tomography
Zaitsev, V. Y., Matveev, L. A., Gelikonov, G. V., Matveyev, A. L., & Gelikonov, V. M. (2013) · Laser Physics Letters · doi:10.1088/1612-2011/10/6/065601 · Cited by 37
Real-Time Blood Pressure Estimation From Force-Measured Ultrasound
Zakrzewski, A. M., Huang, A. Y., Zubajlo, R. E., & Anthony, B. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2873297 · Cited by 37
Strain Assessment in Surgically Resected Inflammatory and Neoplastic Bowel Lesions
Havre, R. F., Leh, S. M., Gilja, O. H., Ødegaard, S., Waage, J., Baatrup, G., & Nesje, L. B. (2012) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0032-1325535 · Cited by 37
Shen, F., Shinohara, K., Kumar, D., Khemka, A., Simoneau, A. R., Werahera, P. N., Li, L., Guo, Y., Narayanan, R., Wei, L., et al. (2008) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2008.27.6.895 · Cited by 37
Ultrasound elastography in neuromuscular and movement disorders
Harmon, B., Wells, M. L., Park, D., & Gao, J. S. (2018) · Clinical Imaging · doi:10.1016/j.clinimag.2018.10.008 · Cited by 37
Childers, M., Franco, W., Nelson, J. S., & Aguilar, G. (2007) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20456 · Cited by 37
Shear Modulus Decomposition Algorithm in Magnetic Resonance Elastography
Kwon, O. I., Park, C., Nam, H. S., Woo, E. J., Seo, J. K., Glaser, K. J., Manduca, A., & Ehman, R. L. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2019823 · Cited by 36
Baghani, A., Eskandari, H., Salcudean, S. E., & Rohling, R. N. (2009) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1196 · Cited by 35
Optical Rheology of Porcine Sclera by Birefringence Imaging
Yamanari, M., Ishii, K., Fukuda, S., Lim, Y., Duan, L., Makita, S., Miura, M., Oshika, T., & Yasuno, Y. (2012) · PLoS ONE · doi:10.1371/journal.pone.0044026 · Cited by 34
Detection of small inclusions by elastography
Fehrenbach, J., Masmoudi, M., Souchon, R., & Trompette, P. (2006) · Inverse Problems · doi:10.1088/0266-5611/22/3/020 · Cited by 34
Self-citationStiffness tomography of eukaryotic intracellular compartments by atomic force microscopy
Janel, S., Popoff, M., Barois, N., Werkmeister, E., Divoux, S., Perez, F., & Lafont, F. (2019) · Nanoscale · doi:10.1039/c8nr08955h · Cited by 33
Zaitsev, V. Y., Vitkin, I. A., Matveev, L. A., Gelikonov, V. M., Matveyev, A. L., & Gelikonov, G. V. (2014) · Radiophysics and Quantum Electronics · doi:10.1007/s11141-014-9505-x · Cited by 33
Theoretical limitations of the elastic wave equation inversion for tissue elastography
Baghani, A., Salcudean, S. E., & Rohling, R. N. (2009) · The Journal of the Acoustical Society of America · doi:10.1121/1.3180495 · Cited by 33
Revolutionizing medical imaging: a comprehensive review of optical coherence tomography (OCT)
Varghese, M., Varghese, S., & Preethi, S. (2024) · Journal of Optics · doi:10.1007/s12596-024-01765-6 · Cited by 32
AMMAR, A. O., Matjafri, M., Suardi, N., Oqlat, M. A., Oqlat, A. A., Abdelrahman, M. A., Farhat, O. F., Ahmad, M. S., Alkhateb, B., Gemanam, S. J., et al. (2018) · Natural and Engineering Sciences · doi:10.28978/nesciences.468972 · Cited by 32
A Review of Biomechanics Analysis of the Umbilical–Placenta System With Regards to Diseases
Saw, S. N., Dai, Y., & Yap, C. H. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.587635 · Cited by 32
Non-rigid Motion Correction for Ultrasound Localization Microscopy of the Liver in vivo
Hao, Y., Wang, Q., Yang, Y., Liu, Z., He, Q., Wei, L., & Luo, J. (2019) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2019.8925749 · Cited by 32
Kapetas, P., Pinker, K., Woitek, R., Clauser, P., Bernathova, M., Spick, C., Helbich, T. H., & Baltzer, P. (2016) · Acta Radiologica · doi:10.1177/0284185116641347 · Cited by 30
Xu, J., Tripathy, S., Rubin, J. M., Stidham, R. W., Johnson, L. A., Higgins, P., & Kim, K. (2012) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2011.12.009 · Cited by 29
Huebner, P., Warren, P. B., Chester, D., Spang, J. T., Brown, A. C., Fisher, M. B., & Shirwaiker, R. A. (2019) · Connective Tissue Research · doi:10.1080/03008207.2019.1624733 · Cited by 28
Expansion of random boundary excitations for elliptic PDEs
Sabelfeld, K. K. (2008) · Monte Carlo Methods and Applications · doi:10.1515/mcma.2007.022 · Cited by 28
Nayak, R., Kumar, V., Webb, J. M., Fatemi, M., & Alizad, A. (2019) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2018.10.028 · Cited by 28
Han, Y., Kim, D., & Kwon, H. (2012) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2012.05.007 · Cited by 27
Analytical phase-tracking-based strain estimation for ultrasound elasticity
Yuan, L., & Pedersen, P. C. (2015) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2014.006701 · Cited by 27
Passive cavitation mapping for monitoring ultrasound therapy
Gyöngy, M. (2010) · Oxford University Research Archive (ORA) (University of Oxford) · doi:10.5287/ora-rjywqrzkx · Cited by 27
Reconstruction of a Fully Anisotropic Elasticity Tensor from Knowledge of Displacement Fields
Bal, G., Monard, F., & Uhlmann, G. A. (2015) · SIAM Journal on Applied Mathematics · doi:10.1137/151005269 · Cited by 26
Model‐Based Reconstructive Elasticity Imaging Using Ultrasound
Aglyamov, S. R., Skovoroda, A. R., Xie, H., Kim, K., Rubin, J. M., O’Donnell, M. P., Wakefield, T. W., Myers, D. D., & Emelianov, S. (2007) · International Journal of Biomedical Imaging · doi:10.1155/2007/35830 · Cited by 26
Caenen, A., Knight, A. E., Rouze, N. C., Bottenus, N. B., Segers, P., & Nightingale, K. R. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.103754 · Cited by 26
Ultrasound elastography: a brief clinical history of an evolving technique
Dietrich, C. F., Dong, Y., Cui, X., Fink, M., Jenssen, C., Moeller, K., Sandrin, L., Tsuneyoshi, S., & Tanter, M. (2024) · Ultrasound International Open · doi:10.1055/a-2378-6926 · Cited by 25
di Pasquo, E., Kiener, A. J. O., DALL’ASTA, A., Commare, A., Angeli, L., Frusca, T., & Ghi, T. (2020) · Clinical Imaging · doi:10.1016/j.clinimag.2020.03.006 · Cited by 25
An integrated model-based software for FUS in moving abdominal organs
Schwenke, M., Strehlow, J., Haase, S., Jenne, J. W., Tanner, C., Langø, T., Loeve, A. J., Karakitsios, I., Xiao, X., Levy, Y., et al. (2015) · International Journal of Hyperthermia · doi:10.3109/02656736.2014.1002817 · Cited by 25
Elasticity mapping of murine abdominal organs in vivo using harmonic motion imaging (HMI)
Payen, T., Palermo, C. F., Sastra, S. A., Chen, H., Han, Y., Olive, K. P., & Konofagou, E. E. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/15/5741 · Cited by 25
Self-citationNayak, R., Kumar, V., Webb, J. M., Gregory, A., Fatemi, M., & Alizad, A. (2018) · Scientific Reports · doi:10.1038/s41598-018-33602-9 · Cited by 25
Phase-based direct average strain estimation for elastography
Ara, S., Mohsin, F., Alam, F., Rupa, S. A., Lee, S. J., Hasan, M. K., & Awwal, R. (2013) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2013.6644732 · Cited by 25
Miyamoto, H., Miura, T., Morizaki, Y., Uehara, K., Ohe, T., & Tanaka, S. (2013) · Hand Surgery · doi:10.1142/s0218810413500251 · Cited by 25
A constrained genetic approach for computing material property of elastic objects
Zhang, Y., Hall, L., Goldgof, D. B., & Sarkar, S. (2006) · IEEE Transactions on Evolutionary Computation · doi:10.1109/tevc.2005.860767 · Cited by 25
Application of Quasistatic Ultrasound Elastography for Examination of Scrotal Lesions
Zeng, B., Chen, F., Qiu, S., Luo, Y., Zhu, Z., Chen, R., & Mao, L. (2015) · Journal of Ultrasound in Medicine · doi:10.7863/ultra.15.03076 · Cited by 24
Gao, Y., Zhao, Y., Choi, S., Chaurasia, A., Ding, H., Haroon, A., Wan, S., & Adeleke, S. M. (2022) · Cancers · doi:10.3390/cancers14225568 · Cited by 23
Metadata
- Authors
- Ophir, J., Alam, S. K., Garra, B. S., Kallel, F., Konofagou, E. E., Krouskop, T., Merritt, C. R. B., Righetti, R., Souchon, R., Srinivasan, S., & Varghese, T.
- Affiliations
- Riverside Research Institute (US)
- University of Vermont (US)
- The University of Texas Health Science Center at Houston (US)
- Brigham and Women's Hospital (US)
- Baylor College of Medicine (US)
- Thomas Jefferson University (US)
- University of Houston (US)
- University of Wisconsin–Madison (US)
- ORCID
- Venue
- Journal of Medical Ultrasonics
- Published
- 2002-12
- Volume
- 29
- Issue
- 4
- Pages
- 155-171
- ISSN
- 1346-4523 (ISSN-L)
- 1613-2254
- OpenAlex
- W2168528001
- Cited by
- 366
- References
- 54
- Citations by year
- 2026: 8 · 2025: 4 · 2024: 15 · 2023: 14 · 2022: 5 · 2021: 21 · 2020: 21 · 2019: 21 · 2018: 28 · 2017: 14 · 2016: 26 · 2015: 26 · 2014: 25 · 2013: 21 · 2012: 24
- FWCI
- 0.51
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Journal of Medical Ultrasonics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- elastography, ultrasound elastography, soft tissue elasticity, elastograms, Young's modulus, Poisson's ratio, tissue strain, diagnosis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.