Relationship between stimulus amplitude, stimulus frequency and neural damage during electrical stimulation of sciatic nerve of cat
Abstract
The relation is investigated between stimulus frequency, stimulus pulse amplitude and the neural damage induced by continuous stimulation of the cat's sciatic nerve. The chronically implanted electrodes were pulsed continuously and the effects of the electrical stimulation were quantified as the amount of early axonal degeneration (EAD) present in the nerves seven days after the continuous stimulation. The primary effect of stimulating at 100 Hz rather than 50 Hz was to cause an increase in the slope of the plot of the amount of EAD versus stimulus amplitude, but the threshold stimulus for the induction of EAD also was slightly lower. There was a small amount of EAD in three of the nerves stimulated at 20 Hz, but there was no detectable correlation between the amount of EAD and the stimulus amplitude. This suggests that continuous electrical stimulation of peripheral nerves at a low frequency induce little or no neural damage, even if the stimulus amplitude is very high. A preliminary presentation of the results has been made elsewhere (Agnew et al., 1993).
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
McCreery et al. found that for all tested degrees of fiber recruitment, a frequency of 20 Hz proved to be safe, whereas with increasing frequency (50 and 100 Hz) even pulses with smaller currents, and therefore only partial fiber recruitment, resulted in neural damage in cat sciatic nerve.
“For all tested degrees of fiber recruitment, a frequency of 20 Hz proved to be safe, whereas with increasing frequency (50 and 100 Hz) even pulses with smaller currents, and therefore only partial fiber recruitment, resulted in neural damage.”
From Safety of long-term electrical peripheral nerve stimulation: review of the state of the art (2019) · cites this paper as [92]
A large part of the literature and of our knowledge about neural stimulation is based on animal studies mostly conducted in the 1980s and 1990s.
“Consequently, a large part of the literature and of our knowledge about neural stimulation is based on animal studies mostly conducted in the 1980s and 1990s [43–45, 62–64, 75, 92, 94, 96, 99, 100].”
From Safety of long-term electrical peripheral nerve stimulation: review of the state of the art (2019) · cites this paper as [92]
Maximal tolerated stimulation pulse frequencies vary for different neural structures as demonstrated in a number of publications including the relatively low stimulus frequency tolerance of motor nerves when compared to examples in the central nervous system.
“Maximal tolerated stimulation pulse frequencies vary for different neural structures as demonstrated in a number of publications including the relatively low stimulus frequency tolerance of motor nerves when compared to examples in the central nervous system [44, 65, 92].”
From Safety of long-term electrical peripheral nerve stimulation: review of the state of the art (2019) · cites this paper as [92]
The only available study about the allowable stimulation frequency in chronic peripheral nerve stimulation suggests that 50 Hz is a maximal limit.
“The only available study about the allowable stimulation frequency in chronic peripheral nerve stimulation suggests that 50 Hz is a maximal limit.”
From Safety of long-term electrical peripheral nerve stimulation: review of the state of the art (2019) · cites this paper as [92]
Cites
Statistical Analysis: A Computer Oriented Approach.
Andrews, D. F., Afifi, A. A., & Azen, S. P. (1974) · Journal of the American Statistical Association · doi:10.2307/2285554 · Cited by 576 · see citing works
Neural prostheses : fundamental studies
Agnew, W. F., & McCreery, D. B. (1990) · Medical Entomology and Zoology · Cited by 316 · see citing works
Self-citationThe Effect of Stimulus Parameters on the Recruitment Characteristics of Direct Nerve Stimulation
Gorman, P. H., & Mortimer, J. T. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325041 · Cited by 313 · see citing works
Statistical Analysis: A Computer Oriented Approach.
Afifi, A. A., & Azen, S. P. (1973) · Biometrics · doi:10.2307/2529182 · Cited by 301 · see citing works
Agnew, W. F., McCreery, D. B., Yuen, T. G. H., & Bullara, L. A. (1989) · Annals of Biomedical Engineering · doi:10.1007/bf02364272 · Cited by 185 · see citing works
Self-citationThe response of the myelinated nerve fiber to short duration biphasic stimulating currents
van den Honert, C., & Mortimer, J. T. (1979) · Annals of Biomedical Engineering · doi:10.1007/bf02363130 · Cited by 152 · see citing works
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. A. (1992) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446202 · Cited by 97 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Tissue damage thresholds during therapeutic electrical stimulation
Cogan, S. F., Ludwig, K. A., Welle, C. G., & Takmakov, P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/021001 · Cited by 386 · see citing works
Safety of long-term electrical peripheral nerve stimulation: review of the state of the art
Günter, C., Delbeke, J., & Ortiz-Catalan, M. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0474-8 · Cited by 198 · see citing works
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133 · see citing works
Maynard, E. M. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.145 · Cited by 126 · see citing works
- Authors
- McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. A.
- Affiliations
- Huntington Medical Research Institutes (US)
- ORCID
- McCreery, D. B.
- Venue
- Medical & Biological Engineering & Computing
- Published
- 1995-05
- Volume
- 33
- Issue
- 3
- Pages
- 426-429
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W2015457931
- Cited by
- 95
- References
- 7
- Citations by year
- 2026: 3 · 2025: 2 · 2024: 2 · 2023: 4 · 2022: 3 · 2021: 5 · 2020: 2 · 2019: 9 · 2018: 4 · 2017: 7 · 2016: 4 · 2015: 6 · 2014: 5 · 2013: 5 · 2012: 2
- FWCI
- 0.26
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Medical & Biological Engineering & Computing (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Neurological Disorders and Stroke (N01-NS-2-2323)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Nerve injury and regeneration
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Keywords
- electrical stimulation, sciatic nerve, axonal degeneration, stimulation frequency, stimulus amplitude, peripheral nerve injury, chronic stimulation, nerve regeneration, cats
- MeSH terms
- Animals, Cats, Electric Stimulation, Electricity, Sciatic Nerve
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review