Performance measurement in scaled teleoperation for microsurgery
The DOI matches its Crossref record; 11 of the 13 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“unintentional tool motion and excessive forces can easily give rise to vision loss or irreversible damage to the retina”
From Preliminary evaluation of a micro-force sensing handheld robot for vitreoretinal surgery (2012) · cites this paper as [2]
Citations
Cites
Virtual reality surgical simulator: The first steps
Satava, R. M. (1993) · Surgical Endoscopy · doi:10.1007/bf00594110 · Cited by 557
Robust model-based motion tracking through the integration of search and estimation
Lowe, D. G. (1992) · International Journal of Computer Vision · doi:10.1007/bf00127170 · Cited by 310
Performance evaluation of a six-axis generalized force-reflecting teleoperator
Hannaford, B., Wood, L., McAffee, D. A., & Zak, H. (1991) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/21.97455 · Cited by 293 · cited 1×
“In this paper, it is proposed that teleoperation systems be evaluated relative to direct manipulation by using completion times and measured instrument positions and forces for a set of typical "generic" [ 11 ] tasks.”
MethodTeleoperation controller design using H/sub ∞/-optimization with application to motion-scaling
Yan, J., & Salcudean, S. E. (1996) · IEEE Transactions on Control Systems Technology · doi:10.1109/87.491198 · Cited by 168 · cited 1×
“A six-degree-of-freedom (6-DOF) scaling teleoperation system is being developed at the University of British Columbia with the objective of providing microsurgeons with improved dexterity via scaled motion and force feedback [5, 13, 14, 15 ].”
Self-citationGreen, P. S., Hill, J. W., Jensen, J. F., & Shah, A. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.391769 · Cited by 126
Telepresence surgery demonstration system
Hill, J. W., Green, P. S., Jensen, J. F., Gorfu, Y., & Shah, A. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.1994.350942 · Cited by 75 · cited 2×
“Other teleoperation systems, such as those used for improved ergonomics [ 1 ] could be evaluated in a similar manner.”
BackgroundDesign of a surgeon-machine interface for teleoperated microsurgery
Charles, S., Williams, R. E., & Hamel, B. (2003) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1989.96030 · Cited by 31
Design and control of a teleoperated microgripper for microsurgery
Ku, S., & Salcudean, S. E. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.1996.503885 · Cited by 26 · cited 5×
“[ 12 ]). Manipulation wrist and gripping forces can then be easily obtained using the same force sensors used during teleoperation.”
BackgroundMethodInfluentialSelf-citationForce feedback-based telemicromanipulation for robot surgery on soft tissues
Sabatini, A. M., Bergamasco, M., & Dario, P. (2003) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1989.96033 · Cited by 22 · cited 1×
“Scaling teleoperation systems have been proposed to overcome dexterity limitations imposed by the small scale of a task [2, 3, 4, 5, 6 , 7, 8]. Force-reflecting teleoperation has also been proposed for telesurgery (see [9] and references within), and training (see [10] and references within).”
BackgroundOn a micro-manipulator for medical application—stability consideration of its bilateral controller
Majima, S., & MATSUSHIMA, K. (1991) · Mechatronics · doi:10.1016/0957-4158(91)90016-4 · Cited by 9 · cited 1×
“Scaling teleoperation systems have been proposed to overcome dexterity limitations imposed by the small scale of a task [2, 3, 4 , 5, 6, 7, 8]. Force-reflecting teleoperation has also been proposed for telesurgery (see [9] and references within), and training (see [10] and references within).”
Background
Research works printed but not linked: 5
- N. Tejima, H. Funakubo, T. Dohi, I. Sakuma, T. Tanishima, and Y. Nomura, “A new microsurgical robot system for corneal transplantation,” in Precision Machinery, 1988, vol. 2, pp. 1–9, 1988.
- S. E. Salcudean and J. Yan, “Towards a force-relecting motion-scaling system for microsurgery,” in Proc. IEEE Intl. Conf. Rob. Aut., pp. 2296–2301, 1994.
- M. Mitsuishi, T. Watanabe, H. Nakanishi, T. Hori, H. Watanabe, and B. Kramer, “A telemicrosurgery system with colocated view and operation points and a rotational force feedback free master manipulator,” in Proc. 1995 Intl. Conf. on Medical Robotics and Computer Assisted Surgery, pp. 111–118, 1995.
- P. S. Schenker and S. T. Charles, “Development of a telemanipulator for dexterity enhanced microsurgery,” in Proc. Med. Rob. Comp. Assist. Surgery, pp. 81–88, 1995.
- J. Yan and S. E. Salcudean, “Design and control of a motion scaling system for microsurgery experiments,” in Proc. Med. Rob. Comp. Assist. Surgery, pp. 211–216, 1994.
Cited by
Medical robotics in computer-integrated surgery
Taylor, R. H., & Stoianovici, D. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817058 · Cited by 997
“Many microsurgical robots (e.g., [34], [104], [114]–[117]) are based on force-reflecting master–slave configurations.”
BackgroundA Steady-Hand Robotic System for Microsurgical Augmentation
Taylor, R., Jensen, P., Whitcomb, L., Barnes, A., Kumar, R., Stoianovici, D., Gupta, P., Wang, Z., Dejuan, E., & Kavoussi, L. (1999) · The International Journal of Robotics Research · doi:10.1177/02783649922067807 · Cited by 528
“Many microsurgical devices (Hunter et al. 1995; Charles 1994; Misuishi et al. 1997; Salcudean, Ku, and Bell 1997; Schenker, Das, and Timothy 1995) are based on forcereflecting master-slave configurations.”
InfluentialMicron: An Actively Stabilized Handheld Tool for Microsurgery
MacLachlan, R. A., Becker, B. C., Tabares, J. C., Podnar, G. W., Lobes, L. A., & Riviere, C. N. (2012) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2169634 · Cited by 270
“Scaling up such forces to be perceptible might offer a significant benefit [30].”
BackgroundCutaneous Feedback of Fingertip Deformation and Vibration for Palpation in Robotic Surgery
Pacchierotti, C., Prattichizzo, D., & Kuchenbecker, K. J. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2455932 · Cited by 235
“It has been shown to enhance surgeon performance in a wide range of applications including microneedle positioning [10], telerobotic catheter insertion [11], suturing simulation [12], cardiothoracic procedures [13], and cell injection [14].”
BackgroundA Steady-Hand Robotic System for Microsurgical Augmentation
Taylor, R. H., Jensen, P. S., Whitcomb, L. L., Barnes, A. C., Kumar, R., Stoianovici, D. S., Gupta, P., Wang, Z., deJuan, E., & Kavoussi, L. R. (1999) · Lecture notes in computer science · doi:10.1007/10704282_112 · Cited by 154
Today's state of the art in surgical robotics
Pott, P. P., Scharf, H., & Schwarz, M. (2005) · Computer Aided Surgery · doi:10.1080/10929080500228753 · Cited by 126
Cutaneous/Tactile Haptic Feedback in Robotic Teleoperation: Motivation, Survey, and Perspectives
Pacchierotti, C., & Prattichizzo, D. (2023) · IEEE Transactions on Robotics · doi:10.1109/tro.2023.3344027 · Cited by 125
“…been shown to enhance operators’ performance in several robotic applications, including microrobotics [5], [6], [7], needle and catheter insertion [8], [9], [10], [11], surgical robotics [9], [12], [13], [14], [15], training [16], [17], assembly [5], [18], [19], [20], cutting [21], [22], grasping…”
Payne, C. J., & Yang, G. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1042-4 · Cited by 119
Meli, L., Pacchierotti, C., & Prattichizzo, D. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2303052 · Cited by 115
Kumar, R., Berkelman, P. J., Gupta, P., Barnes, A., Jensen, P. S., Whitcomb, L. L., & Taylor, R. H. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2000.844120 · Cited by 110
“Most prior robotic micro-manipulati on systems emphasized traditional master-slave and telerobotic manipulation [30] including virtual training [15] , manipulation objects in hazardous [28], remote surgery [11, 27] , and [2, 15, 16, 22, 26 , 29] . In we are in developing a system both the”
MethodTransparent Bilateral Teleoperation under Position and Rate Control
Salcudean, S. E., Zhu, M. C., Zhu, W.-H., & Hashtrudi-Zaad, K. (2000) · The International Journal of Robotics Research · doi:10.1177/02783640022068020 · Cited by 106
“…of radioactive materials, the meaning of teleoperation has expanded to include manipulation at a different scale and in virtual worlds (Kazerooni 1990; Yan and Salcudean 1996; Parker, Salcud-ean, and Lawrence 1993; Hunter et al. 1990; Salcudean, Ku, and Bell 1997; Iwata 1990; DiMaio et al. 1998).”
BackgroundSelf-citationSteering and Control of Miniaturized Untethered Soft Magnetic Grippers With Haptic Assistance
Pacchierotti, C., Ongaro, F., van den Brink, F., Yoon, C., Prattichizzo, D., Gracias, D. H., & Misra, S. (2017) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2016.2635106 · Cited by 96
“Its benefits have been proved in cardiothoracic procedures [38], microneedle positioning [39], telerobotic catheter insertion [40], palpation [41], cell injection [42], [43], and even micromanipulation [44]–[49].”
Reliable and Enhanced Stiffness Perception in Soft-tissue Telemanipulation
Gersem, G. D., Brussel, H. V., & Tendick, F. (2005) · The International Journal of Robotics Research · doi:10.1177/0278364905057861 · Cited by 89
“The merits of scaled telemanipulation for eye surgery are described in Kumar et al. (1999) and Salcudean, Ku, and Bell (1997).”
BackgroundRemote ultrasound diagnostic system
Mitsuishi, M., Warisawa, S., Tsuda, T., Higuchi, T., Koizumi, N., Hashizume, H., & Fujiwara, K. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2001.932834 · Cited by 88
Meli, L., Pacchierotti, C., & Prattichizzo, D. (2017) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.1809 · Cited by 83
Control for teleoperation and haptic interfaces
Salcudean, S. E. (2005) · Springer eBooks · doi:10.1007/bfb0015076 · Cited by 83
Self-citationApplied force during vitreoretinal microsurgery with handheld instruments
Jagtap, A. D., & Riviere, C. N. (2005) · The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1403792 · Cited by 79
“Salcudean et al. have presented results from microsurgical experiments in vitro using force-reflecting teleoperation [7], and Tokuyasu and Kitamura have presented in vitro results for reflected feedback of torque [8].”
A Robot System for Medical Ultrasound
Salcudean, S. E., Zhu, W.-H., Abolmaesumi, P., Bachmann, S., & Lawrence, P. D. (2000) · Springer eBooks · doi:10.1007/978-1-4471-0765-1_24 · Cited by 79
Self-citationMedical Robotics and Computer-Integrated Interventional Medicine
Taylor, R. H., Kazanzides, P., Fischer, G. S., & Simaan, N. (2008) · Elsevier eBooks · doi:10.1016/b978-0-12-816034-3.00019-5 · Cited by 72
Troccaz, J., Peshkin, M. A., & Davies, B. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80006-6 · Cited by 67
“Such systems may allow one to introduce scaling factors between the forces and displacements ordered by the operator and those executed by the robot (Salcudean et al., 1997).”
BackgroundTeleoperation of Steerable Flexible Needles by Combining Kinesthetic and Vibratory Feedback
Pacchierotti, C., Abayazid, M., Misra, S., & Prattichizzo, D. (2014) · IEEE Transactions on Haptics · doi:10.1109/toh.2014.2360185 · Cited by 66
Mitsuishi, M., Arata, J., Tanaka, K., Miyamoto, M., Yoshidome, T., Iwata, S., Hashizume, M., & Warisawa, S. (2004) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2003.1241995 · Cited by 65
Real-Time Haptic Feedback in Laparoscopic Tools for Use in Gastro-Intestinal Surgery*
Hu, T., Castellanos, A. E., Tholey, G., & Desai, J. P. (2002) · Lecture notes in computer science · doi:10.1007/3-540-45786-0_9 · Cited by 57
Preliminary evaluation of a micro-force sensing handheld robot for vitreoretinal surgery
Gonenc, B., Balicki, M. A., Handa, J., Gehlbach, P., Riviere, C. N., Taylor, R. H., & Iordachita, I. (2012) · 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2012.6385715 · Cited by 54
“[17] and for reflected torque feedback by Tokuyasu and Kitamura [18].”
BackgroundA Smart Haptic Hand-Held Device for Neurosurgical Microdissection
Payne, C. J., Marcus, H. J., & Yang, G. (2015) · Annals of Biomedical Engineering · doi:10.1007/s10439-015-1258-y · Cited by 52
Tele-micro-surgery system with intelligent user interface
Mitsuishi, M., Tomisaki, S., Yoshidome, T., Hashizume, H., & Fujiwara, K. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2000.844826 · Cited by 50
PADyC: a synergistic robot for cardiac puncturing
Schneider, O., Troccaz, J., Chavanon, O., & Blin, D. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2000.846465 · Cited by 49
Experimental evaluation of co-manipulated ultrasound-guided flexible needle steering
Abayazid, M., Pacchierotti, C., Moreira, P. L. D. F., Alterovitz, R., Prattichizzo, D., & Misra, S. (2015) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.1680 · Cited by 48
“In medicine, haptic feedback has been shown to improve performance in fine microneedle positioning (23), telerobotic catheter insertion (24), suturing simulation (25), cardiothoracic procedures (26), and cell injection systems (27).”
BackgroundSurgical Skill Evaluation by Force Data for Endoscopic Sinus Surgery Training System
Yamauchi, Y., Yamashita, J., Morikawa, O., Hashimoto, R., Mochimaru, M., Fukui, Y., Uno, H., & Yokoyama, K. (2002) · Lecture notes in computer science · doi:10.1007/3-540-45786-0_6 · Cited by 47
“In the latter cases, the difference to an adequate force is the most meaningful metric [19].”
BackgroundTelesurgery System for Intravascular Neurosurgery
TANIMOTO, M., Arai, F., Fukuda, T., Itoigawa, K., Hashimoto, M., Takahashi, I., & Negoro, M. (2000) · Lecture notes in computer science · doi:10.1007/978-3-540-40899-4_4 · Cited by 45
Lee, J., Zhang, X., Park, C. H., & Kim, M. J. (2021) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2021.3060708 · Cited by 44
“Advantages of the haptic system have been confirmed in cardiothoracic procedures [27], microneedle positioning [28], telerobotic catheter insertion [29], palpation [25], cell injection [30], [31], and even micro-manipulation [32]–[35].”
BackgroundA remote surgery experiment between Japan-Korea using the minimally invasive surgical system
Arata, J., Takahashi, H., Pitakwatchara, P., Warisawa, S., Konishi, K., Tanoue, K., Ieiri, S., Shimizu, S., Nakashima, N., Okamura, K., et al. (2006) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2006.1641193 · Cited by 43
“are prompting a research for a remote operation by considering the size effect [15].”
BackgroundPerformance of Robotic Augmentation in Microsurgery-Scale Motions
Kumar, R., Goradia, T. M., Barnes, A. C., Jensen, P. S., Whitcomb, L. L., Stoianovici, D. S., Auer, L. M., & Taylor, R. H. (1999) · Lecture notes in computer science · doi:10.1007/10704282_120 · Cited by 41
Remote operation of a micro-surgical system
Mitsuishi, M., Iizuka, Y., Watanabe, H., Hashizume, H., & Fujiwara, K. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.1998.677220 · Cited by 41
Falcone, S., Englebienne, G., van Erp, J. B. F., & Heylen, D. (2022) · Human-Computer Interaction · doi:10.1080/07370024.2022.2039147 · Cited by 35
“This category of tasks requires the operator to place an object in a specific point in the workspace (Hannaford et al., 1991; Lozano-Pérez et al., 1989; Salcudean et al., 1997).”
BackgroundSimple Biomanipulation Tasks with “Steady Hand” Cooperative Manipulator
Kapoor, A., Kumar, R., & Taylor, R. H. (2003) · Lecture notes in computer science · doi:10.1007/978-3-540-39899-8_18 · Cited by 32
“There are several factors that affect the success rates including the purity and concentration of the DNA construct to be injected, human factors, and experimental factors such as injection accuracy and successful implantation.”
BackgroundKinaesthetic Feedback and Enhanced Sensitivity in Robotic Endoscopic Telesurgery
Gersem, G. D. (2005) · Lirias · Cited by 32
Experiments with a steady hand robot in constrained compliant motion and path following
Kumar, R., Jensen, P., & Taylor, R. H. (2003) · IEEE RO-MAN · doi:10.1109/roman.1999.900321 · Cited by 28
Telerobotic Control by Virtual Fixtures for Surgical Applications
Li, M., Kapoor, A., & Taylor, R. H. (2007) · Springer eBooks · doi:10.1007/978-3-540-71364-7_23 · Cited by 28
“Although most of the teleoperated systems are admittance-controlled microsurgical robots ([6, 11, 12, 13, 14 ]), based on”
BackgroundHand-held microsurgical forceps with force-feedback for micromanipulation
Payne, C. J., Rafii-Tari, H., Marcus, H. J., & Yang, G. (2014) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2014.6906623 · Cited by 26
“The corollary is that devices that scale up tool-tissue interaction forces may reduce the risk of tissue injury, and improve patient safety [9].”
BackgroundAn Augmentation System for Fine Manipulation
Kumar, R., Hager, G. D., Barnes, A., Jensen, P. S., & Taylor, R. H. (2000) · Lecture notes in computer science · doi:10.1007/978-3-540-40899-4_99 · Cited by 23
“The example task is a modified (or minimally invasive) version of the peg-in-hole task, a common task used for performance evaluation [24],[25],[26].”
MethodHaptic tele-operation system control design for the ultrasound task: A loop-shaping approach
Zandsteeg, C. J., Bruijnen, D., & van de Molengraft, R. (2010) · Mechatronics · doi:10.1016/j.mechatronics.2010.02.007 · Cited by 22
“However, the absence of force perception in tele-operation systems results in an increase of the task completion time [1] and higher contact forces [2] in comparison with direct manipulation.”
BackgroundSurgical Robotics: An Introduction
Rembold, U., & Burghart, C. R. (2001) · Journal of Intelligent & Robotic Systems · doi:10.1023/a:1008159527787 · Cited by 22
“The method is being successfully applied in numerous surgeries, and many robotic devices, special tools and computerised aids have been developed for it, such as videoscopes, trocars, surgical instruments and robotic end effectors [12, 17, 26, 27, 29, 33, 34].”
MethodRobot-Assisted Surgery System with Kinesthetic Feedback
Urban, V., Wapler, M. C., Neugebauer, J., Hiller, A., Stallkamp, J. L., & Weisener, T. (1998) · Computer Aided Surgery · doi:10.3109/10929089809148147 · Cited by 21
Ongaro, F., Pacchierotti, C., Yoon, C., Prattichizzo, D., Gracias, D. H., & Misra, S. (2016) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2016.7523742 · Cited by 20
“In medical scenarios, haptic feedback has been demonstrated to improve performance in fine microneedle positioning [24], telerobotic catheter”
Hand–tool–tissue interaction forces in neurosurgery for haptic rendering
Aggravi, M., Momi, E. D., DiMeco, F., Cardinale, F., Casaceli, G., Riva, M., Ferrigno, G., & Prattichizzo, D. (2015) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1439-8 · Cited by 19
A “Smart” Force-Limiting Instrument for Microsurgery: Laboratory and In Vivo Validation
Marcus, H. J., Payne, C. J., Kailaya-Vasan, A., Griffiths, S., Clark, J. A., Yang, G., Darzi, A. W., & Nandi, D. (2016) · PLoS ONE · doi:10.1371/journal.pone.0162232 · Cited by 19
“Master-slave platforms, such as those by Sutherland et al and Salcudean et al, allow for force feedback and can therefore reduce the forces exerted by surgeons[11, 12].”
BackgroundVibrotactile stimuli for augmented haptic feedback in robot-assisted surgery
Peon, A. R., Pacchierotti, C., & Prattichizzo, D. (2013) · World Haptics Conference · doi:10.1109/whc.2013.6548454 · Cited by 18
“Improved performance when providing force feedback was also demonstrated for telerobotic catheter insertion [9], suturing simulation [15], cardiothoracic procedures [10], cell injection systems [21], and fine microneedle positioning [26].”
MethodA Tele-Operated Microsurgical Forceps-Driver With a Variable Stiffness Haptic Feedback Master Device
Park, S., Jang, N., Ihn, Y. S., Yang, S., Jeong, J., Yim, S., Oh, S., Kim, K., & Hwang, D. (2020) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2020.2969161 · Cited by 17
An embodiment paradigm in evaluation of human-in-the-loop control
Fröhner, J., Beckerle, P., Endo, S., & Hirche, S. (2019) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2019.01.036 · Cited by 17
Micro-Neurosurgical System in the Deep Surgical Field
Asai, D., Katopo, S., Arata, J., Warisawa, S., Mitsuishi, M., Morita, A., Sora, S., Kirino, T., & Mochizuki, R. (2004) · Lecture notes in computer science · doi:10.1007/978-3-540-30136-3_5 · Cited by 17
“Micro-manipulation is performed by scaling the master and the slave manipulator motions [5].”
Kinesthetic and vibrotactile haptic feedback improves the performance of laser microsurgery
Fichera, L., Pacchierotti, C., Olivieri, E., Prattichizzo, D., & Mattos, L. S. (2016) · IEEE Haptics Symposium · doi:10.1109/haptics.2016.7463156 · Cited by 16
“of task completion time [7], [8], accuracy [9], [10], [11], peak and mean applied force [8], [12], [13], and fine tool positioning [14].”
BackgroundTaylor, R. H., & Kazanzides, P. (2008) · Advances in computers · doi:10.1016/s0065-2458(08)00405-1 · Cited by 14
Human-Inspired Haptic-Enabled Learning From Prehensile Move Demonstrations
Lillienskiold, A., Rahal, R., Giordano, P. R., Pacchierotti, C., & Misimi, E. (2021) · IEEE Transactions on Systems Man and Cybernetics Systems · doi:10.1109/tsmc.2020.3046775 · Cited by 14
Force-reflecting teleoperation over wide-area networks
Polouchine, I. (2009) · Carleton University's Institutional Repository (MacOdrum Library, Carleton University) · doi:10.22215/etd/2009-06337 · Cited by 14
Steering of flexible needles combining kinesthetic and vibratory force feedback
Pacchierotti, C., Abayazid, M., Misra, S., & Prattichizzo, D. (2014) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2014.6942710 · Cited by 12
“However, force feedback is widely considered to be a valuable navigation tool during teleoperated surgical procedures [14], [15].”
BackgroundImproving the Development of Surgical Skills with Virtual Fixtures in Simulation
Hernansanz, A., Zerbato, D., Gasperotti, L., Scandola, M., Fiorini, P., & Casals, A. (2012) · Lecture notes in computer science · doi:10.1007/978-3-642-30618-1_16 · Cited by 12
Microscale Tracking of Surgical Instrument Motion
Riviere, C. N., & Khosla, P. K. (1999) · Lecture notes in computer science · doi:10.1007/10704282_117 · Cited by 12
“Thorough evaluation of microsurgical accuracy enhancement devices (whether robotic manipulators [4,5,6,7] or active hand-held instruments [8]), as well as more traditional passive instruments, therefore requires sensing of instrument tip position in three dimensions, and with accuracy to less than 10 μm.”
BackgroundScaled position-force tracking for wireless teleoperation of miniaturized surgical robotic system
Guo, J., Liu, C., & Poignet, P. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6943604 · Cited by 10
Visually Perceived Force Feedback in Simulated Robotic Surgery
Cao, C. G. L., Webster, J. L., Perreault, J., Schwaitzberg, S. D., & Rogers, G. S. (2003) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/154193120304701220 · Cited by 9
Marchal, M., & Pacchierotti, C. (2025) · Springer eBooks · doi:10.1007/978-3-319-77270-7_4 · Cited by 8
Performance improvement of bilateral control systems using derivative of force
Baran, E. A., Uzunović, T., & Şabanoviç, A. (2018) · Robotica · doi:10.1017/s0263574718000607 · Cited by 8
“[25] considering the aspects of stability and transparency.”
BackgroundReview on bilateral teleoperation with force, position, power and impedance scaling
Perera, A. G., & Abeykoon, A. M. H. S. (2014) · International Conference on Information and Automation for Sustainability (ICIAfS) · doi:10.1109/iciafs.2014.7069636 · Cited by 8
“In parallel to these studies, the integration of force, position and impedance scaling techniques resulted in sophisticated teleoperation activities such as robot assisted minimally invasive surgeries and micro assembly [12,13].”
Cao, C. G. L., & Milgram, P. (2007) · PRESENCE Virtual and Augmented Reality · doi:10.1162/pres.16.6.584 · Cited by 7
A haptic tele-manipulation environment for a vibration-driven micromechatronic device
Vlachos, K. I., Vartholomeos, P., & Papadopoulos, E. G. (2007) · IEEE/ASME International Conference on Advanced Intelligent Mechatronics · doi:10.1109/aim.2007.4412589 · Cited by 7
“The developed solutions are presented and discussed.”
Evaluation of Joystick Sensitivity in Telemanipulative Microassembly
Pongrac, H., Reiter, A., Faerber, B., & Zaeh, M. F. (2007) · IEEE International Workshop on Haptic Audio visual Environments and Games · doi:10.1109/have.2007.4371590 · Cited by 6
Lee, T., Choi, D., & Lee, W. (2021) · Journal of Computational Design and Engineering · doi:10.1093/jcde/qwab056 · Cited by 6
Vlachos, K. I., & Papadopoulos, E. G. (2008) · Journal of Computing and Information Science in Engineering · doi:10.1115/1.2988385 · Cited by 6
Controlling Servo Motor Angle by Exploiting Kinect SDK
Foroughi, F., & Zong, P. (2015) · International Journal of Computer Applications · doi:10.5120/20433-2764 · Cited by 5
Development of an Advanced Micro-neurosurgical Robotic System for the Deep Surgical Field
Satoshi, B. A. B. A., Asai, D., Warisawa, S., Mitsuishi, M., Morita, A., Sora, S., Mochizuki, R., & Shiraishi, T. (2006) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2006.1639127 · Cited by 5
“Micro-manipulation is performed by scaling the master and the slave manipulator motions [7].”
Design and Validation of a Passive Motion Scaling Mechanism Prototype for Microsurgery
Choi, D., Lee, T., Song, J.-B., & Lee, W. (2022) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-022-00624-3 · Cited by 4
Virtual Robot: A new teleoperation paradigm for minimally invasive robotic surgery
Hernansanz, A., Amat, J., & Casals, A. (2012) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2012.6290803 · Cited by 4
“RIMS also offers some other performances as, tremor cancellation [6], motion scaling [7], [8] or trajectory guidance [9].”
BackgroundUngrounded haptic-feedback for hand-held surgical robots
Payne, C. J. (2015) · Spiral (Imperial College London) · doi:10.25560/26587 · Cited by 4
“Another significant advantage of the master-slave approach is the ability to attenuate the motion of the surgical tool tip [20].”
BackgroundTREATMENT OF RETINAL DISEASE IN THE NEW MILLENNIUM
DEJUANJR, E., Cooney, M. J., Humayun, M. S., & Jensen, P. S. (1999) · Ophthalmology Clinics of North America · doi:10.1016/s0896-1549(05)70132-2 · Cited by 4
Development of a robotic surgical system for total knee joint replacement
Warisawa, S., Kawano, H., & Mitsuishi, M. (2003) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/irds.2002.1043955 · Cited by 3
A flexible architecture for telemanipulator control
Weber, A., Breitwieser, H., & Benner, J. (2002) · Control Engineering Practice · doi:10.1016/s0967-0661(02)00078-3 · Cited by 3
Tele-micro-surgery: analysis and tele-micro-blood-vessel suturing experiment
Mitsuishi, M., Watanabe, H., Kubota, H., Iizuka, Y., & Hashizume, H. (1998) · Lecture notes in control and information sciences · doi:10.1007/bfb0112984 · Cited by 3
A Remote Surgery Experiment between Japan-Korea using the Minimally Invasive Surgical System
Arata, J., Takahashi, H., Warisawa, S., Konishi, K., Tanoue, K., Ieiri, S., Shimizu, S., Nakashima, N., Okamura, K., Kim, Y. S., et al. (2007) · Journal of Japan Society of Computer Aided Surgery · doi:10.5759/jscas1999.8.401 · Cited by 3
Shared control and authority distribution for robotic teleoperation
Rahal, R. (2020) · theses.fr (ABES) · doi:10.70675/faa0a309z8a93z4a80zbfadz5bf5a34e52a0 · Cited by 3
Requirements analysis and preliminary design of a robotic assistant for reconstructive microsurgery
Vanthournhout, L., Herman, B., Duisit, J., Chateau, F., Szewczyk, J., Lengelé, B., & Raucent, B. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319497 · Cited by 2
“However, if a large reduction increases the accuracy, it also slows down the motion and increases operation time [5], [9]–[14].”
BackgroundPassivity-based multilateral control for delayed teleoperation
Panzirsch, M. (2018) · UPM Digital Archive (Technical University of Madrid) · doi:10.20868/upm.thesis.52592 · Cited by 2
Falcone, S. (2023) · doi:10.3990/1.9789036558815 · Cited by 2
Stability analysis of scaled force-position control architecture with sensor noise
Wulandari, M., & Kwon, D. S. (2009) · International Conference on Advanced Robotics (ICAR) · Cited by 1
Cutaneous and Kinesthetic Cues for Enhanced Navigation Feedback in Teleoperation
Pacchierotti, C. (2015) · Springer series on touch and haptic systems · doi:10.1007/978-3-319-25457-9_6 · Cited by 1
Tele-surgery Experiment between Japan-Thailand using a High-speed Network
Arata, J., Takahashi, H., Warisawa, S., Tanoue, K., Konishi, K., Ieiri, S., Shimizu, S., Nakashima, N., Okamura, K., Fujino, Y., et al. (2008) · Journal of Japan Society of Computer Aided Surgery · doi:10.5759/jscas1999.10.139 · Cited by 1
Design and Experimental Validation of a Hybrid Micro Tele-Manipulation System
Vlachos, K. I., & Papadopoulos, E. G. (2014) · Lecture notes in computer science · doi:10.1007/978-3-319-07064-3_14 · Cited by 1
“It is well known now that not only the visual but also the haptic feedback can be helpful for a successful tele-operated micromanipulation procedure, [1].”
BackgroundMagnetic Gradient-Based Magnetic Tweezer System for 3D and Swarm Control of Microswimmer
Zhang, X. (2021) · SMU Scholar (Southern Methodist University) · Cited by 1
Robotically steering flexible needles
Abayazid, M. (2015) · doi:10.3990/1.9789036539418 · Cited by 1
“In medicine, haptic feedback has been shown to improve performance in fine microneedle positioning [167], telerobotic catheter insertion [168], suturing simulation [169], cardiothoracic procedures [170], and cell injection systems [171].”
BackgroundOn autonomous and teleoperated aerial service robots
Mersha, A. Y. (2014) · doi:10.3990/1.9789036536585 · Cited by 1
衛, 光. (1998) · BME · doi:10.11239/jsmbe1987.12.11_35 · Cited by 1
Remote Process Control and Monitoring Using Matlab
Vajnberger, V., Silajdzic, S., & Osmić, N. (2012) · InTech eBooks · doi:10.5772/46464
“Some of the examples where robotic arms found their appliance are: in vehicle construction where efficiency and reliability are required, in chemical industry where environment is not suitable for human, in medicine where robotic arm precision is used in operations, etc [13].”
BackgroundHuman control characteristics in bilateral micro-teleoperation system
Murakami, E. A. Y., Shibata, K., Zheng, X.-Z., & Ito, K. (2002) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2000.973218
Sensory Subtraction in Teleoperation: Substituting Haptic Force with Cutaneous Stimuli
Pacchierotti, C. (2015) · Springer series on touch and haptic systems · doi:10.1007/978-3-319-25457-9_1
Surgical Skill Evaluation in Endoscopic Sinus Surgery Training System
Yamauchi, Y., Yamashita, J., Morikawa, O., Hashimoto, R., Mochimaru, M., Fukui, Y., Uno, H., & Yokoyama, K. (2002) · Journal of Japan Society of Computer Aided Surgery · doi:10.5759/jscas1999.4.13
Intelligent Robotics. Fundamental Methods Necessary for Remote Manual Operation.
Mitsuishi, M. (1998) · Journal of the Robotics Society of Japan · doi:10.7210/jrsj.16.601
Sensory subtraction with cutaneous feedback to ensure safety in bimanual robot-assisted surgery
Meli, L., Pacchierotti, C., & Prattichizzo, D. (2014) · Use Siena air (University of Siena)
Monitoring the movement of the upper limb in the context of rehabilitation games
Grabowski, A., & Lipiński, T. (2018) · Mechanik · doi:10.17814/mechanik.2018.7.69
“many applications aimed at medicine and rehabilitation were created [2, 3].”
BackgroundControlling the motion of a two-arm mobile robot through virtual reality techniques
Grabowski, A., & Jankowski, J. (2018) · Mechanik · doi:10.17814/mechanik.2018.7.66
“This results in a longer task execution time [2] and an increase in the pressure force in comparison with direct manipulation [3].”
ResultA Flexible Architecture for Telemanipulator Control
Weber, A., Breitwieser, H., & Benner, J. (2001) · IFAC Proceedings Volumes · doi:10.1016/s1474-6670(17)41676-4
Chinello, F., Pacchierotti, C., Fang, C., & Seifi, H. (2022) · Nordic Conference on Human-Computer Interaction · doi:10.1145/3547522.3558898
“It has been proven to enhance operators’ performance in a large range of robotic applications, including micro-robotics [4, 18], needle and catheter insertion [1, 16, 22], surgical knot tying [3, 14], waste management [2].”
Background
Metadata
- Authors
- Salcudean, S. E., Ku, S., & Bell, G.
- Affiliations
- University of British Columbia (CA)
- Corresponding author
- Salcudean, S. E.
- ORCID
- Salcudean, S. E.
- Venue
- Lecture Notes in Computer Science
- Publisher
- Springer Berlin Heidelberg
- Published
- 1997
- Pages
- 789-798
- ISSN
- 0302-9743 (ISSN-L)
- 1611-3349
- OpenAlex
- W2155342391
- Cited by
- 96
- References
- 13
- Citations by year
- 2025: 1 · 2023: 2 · 2022: 2 · 2021: 3 · 2020: 2 · 2019: 1 · 2018: 4 · 2017: 2 · 2016: 3 · 2015: 9 · 2014: 9 · 2013: 2 · 2012: 4
- FWCI
- 24.75
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Lecture notes in computer science (publishedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
- Health Sciences › Medicine › Surgery › Surgical Simulation and Training
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Telemedicine and Telehealth Implementation
- Keywords
- teleoperation, microsurgery, performance measurement, operating microscope, task errors, completion time
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.