Performance measurement in scaled teleoperation for microsurgery
The DOI matches its Crossref record; 11 of the 13 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“unintentional tool motion and excessive forces can easily give rise to vision loss or irreversible damage to the retina”
From Preliminary evaluation of a micro-force sensing handheld robot for vitreoretinal surgery (2012) · cites this paper as [2]
Citations
Cites
Virtual reality surgical simulator: The first steps
Satava, R. M. (1993) · Surgical Endoscopy · doi:10.1007/bf00594110 · Cited by 557
Robust model-based motion tracking through the integration of search and estimation
Lowe, D. G. (1992) · International Journal of Computer Vision · doi:10.1007/bf00127170 · Cited by 310
Performance evaluation of a six-axis generalized force-reflecting teleoperator
Hannaford, B., Wood, L., McAffee, D. A., & Zak, H. (1991) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/21.97455 · Cited by 293 · cited 1×
“In this paper, it is proposed that teleoperation systems be evaluated relative to direct manipulation by using completion times and measured instrument positions and forces for a set of typical "generic" [ 11 ] tasks.”
MethodTeleoperation controller design using H/sub ∞/-optimization with application to motion-scaling
Yan, J., & Salcudean, S. E. (1996) · IEEE Transactions on Control Systems Technology · doi:10.1109/87.491198 · Cited by 168 · cited 1×
“A six-degree-of-freedom (6-DOF) scaling teleoperation system is being developed at the University of British Columbia with the objective of providing microsurgeons with improved dexterity via scaled motion and force feedback [5, 13, 14, 15 ].”
Self-citationGreen, P. S., Hill, J. W., Jensen, J. F., & Shah, A. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.391769 · Cited by 126
Telepresence surgery demonstration system
Hill, J. W., Green, P. S., Jensen, J. F., Gorfu, Y., & Shah, A. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.1994.350942 · Cited by 75 · cited 2×
“Other teleoperation systems, such as those used for improved ergonomics [ 1 ] could be evaluated in a similar manner.”
BackgroundDesign of a surgeon-machine interface for teleoperated microsurgery
Charles, S., Williams, R. E., & Hamel, B. (2003) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1989.96030 · Cited by 31
Design and control of a teleoperated microgripper for microsurgery
Ku, S., & Salcudean, S. E. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.1996.503885 · Cited by 26 · cited 5×
“[ 12 ]). Manipulation wrist and gripping forces can then be easily obtained using the same force sensors used during teleoperation.”
BackgroundMethodInfluentialSelf-citationForce feedback-based telemicromanipulation for robot surgery on soft tissues
Sabatini, A. M., Bergamasco, M., & Dario, P. (2003) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1989.96033 · Cited by 22 · cited 1×
“Scaling teleoperation systems have been proposed to overcome dexterity limitations imposed by the small scale of a task [2, 3, 4, 5, 6 , 7, 8]. Force-reflecting teleoperation has also been proposed for telesurgery (see [9] and references within), and training (see [10] and references within).”
BackgroundOn a micro-manipulator for medical application—stability consideration of its bilateral controller
Majima, S., & MATSUSHIMA, K. (1991) · Mechatronics · doi:10.1016/0957-4158(91)90016-4 · Cited by 9 · cited 1×
“Scaling teleoperation systems have been proposed to overcome dexterity limitations imposed by the small scale of a task [2, 3, 4 , 5, 6, 7, 8]. Force-reflecting teleoperation has also been proposed for telesurgery (see [9] and references within), and training (see [10] and references within).”
BackgroundDexterity enhancement in microsurgery using a motion-scaling system and microgripper
Ku, S., & Salcudean, S. E. (2002) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/icsmc.1995.537737 · Cited by 7 · cited 1×
“A six-degree-of-freedom (6-DOF) scaling teleoperation system is being developed at the University of British Columbia with the objective of providing microsurgeons with improved dexterity via scaled motion and force feedback [5, 13 , 14, 15].”
Self-citation
Research works printed but not linked: 5
- N. Tejima, H. Funakubo, T. Dohi, I. Sakuma, T. Tanishima, and Y. Nomura, “A new microsurgical robot system for corneal transplantation,” in Precision Machinery, 1988, vol. 2, pp. 1–9, 1988.
- S. E. Salcudean and J. Yan, “Towards a force-relecting motion-scaling system for microsurgery,” in Proc. IEEE Intl. Conf. Rob. Aut., pp. 2296–2301, 1994.
- M. Mitsuishi, T. Watanabe, H. Nakanishi, T. Hori, H. Watanabe, and B. Kramer, “A telemicrosurgery system with colocated view and operation points and a rotational force feedback free master manipulator,” in Proc. 1995 Intl. Conf. on Medical Robotics and Computer Assisted Surgery, pp. 111–118, 1995.
- P. S. Schenker and S. T. Charles, “Development of a telemanipulator for dexterity enhanced microsurgery,” in Proc. Med. Rob. Comp. Assist. Surgery, pp. 81–88, 1995.
- J. Yan and S. E. Salcudean, “Design and control of a motion scaling system for microsurgery experiments,” in Proc. Med. Rob. Comp. Assist. Surgery, pp. 211–216, 1994.
Cited by
Medical robotics in computer-integrated surgery
Taylor, R. H., & Stoianovici, D. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817058 · Cited by 997
“Many microsurgical robots (e.g., [34], [104], [114]–[117]) are based on force-reflecting master–slave configurations.”
BackgroundA Steady-Hand Robotic System for Microsurgical Augmentation
Taylor, R., Jensen, P., Whitcomb, L., Barnes, A., Kumar, R., Stoianovici, D., Gupta, P., Wang, Z., Dejuan, E., & Kavoussi, L. (1999) · The International Journal of Robotics Research · doi:10.1177/02783649922067807 · Cited by 528
“Many microsurgical devices (Hunter et al. 1995; Charles 1994; Misuishi et al. 1997; Salcudean, Ku, and Bell 1997; Schenker, Das, and Timothy 1995) are based on forcereflecting master-slave configurations.”
InfluentialMicron: An Actively Stabilized Handheld Tool for Microsurgery
MacLachlan, R. A., Becker, B. C., Tabares, J. C., Podnar, G. W., Lobes, L. A., & Riviere, C. N. (2012) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2169634 · Cited by 270
“Scaling up such forces to be perceptible might offer a significant benefit [30].”
BackgroundCutaneous Feedback of Fingertip Deformation and Vibration for Palpation in Robotic Surgery
Pacchierotti, C., Prattichizzo, D., & Kuchenbecker, K. J. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2455932 · Cited by 235
“It has been shown to enhance surgeon performance in a wide range of applications including microneedle positioning [10], telerobotic catheter insertion [11], suturing simulation [12], cardiothoracic procedures [13], and cell injection [14].”
BackgroundA Steady-Hand Robotic System for Microsurgical Augmentation
Taylor, R. H., Jensen, P. S., Whitcomb, L. L., Barnes, A. C., Kumar, R., Stoianovici, D. S., Gupta, P., Wang, Z., deJuan, E., & Kavoussi, L. R. (1999) · Lecture notes in computer science · doi:10.1007/10704282_112 · Cited by 154
Metadata
- Authors
- Salcudean, S. E., Ku, S., & Bell, G.
- Affiliations
- University of British Columbia (CA)
- Corresponding author
- Salcudean, S. E.
- ORCID
- Salcudean, S. E.
- Venue
- Lecture Notes in Computer Science
- Publisher
- Springer Berlin Heidelberg
- Published
- 1997
- Pages
- 789-798
- ISSN
- 0302-9743 (ISSN-L)
- 1611-3349
- OpenAlex
- W2155342391
- Cited by
- 96
- References
- 13
- Citations by year
- 2025: 1 · 2023: 2 · 2022: 2 · 2021: 3 · 2020: 2 · 2019: 1 · 2018: 4 · 2017: 2 · 2016: 3 · 2015: 9 · 2014: 9 · 2013: 2 · 2012: 4
- FWCI
- 24.75
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Lecture notes in computer science (publishedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
- Health Sciences › Medicine › Surgery › Surgical Simulation and Training
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Telemedicine and Telehealth Implementation
- Keywords
- teleoperation, microsurgery, performance measurement, operating microscope, task errors, completion time
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.