Continuous glucose monitoring in adults with type 2 diabetes: a systematic review and meta-analysis
Open accessAbstract
Aims/hypothesis: Continuous glucose monitoring (CGM) is increasingly used in the treatment of type 2 diabetes, but the effects on glycaemic control are unclear. The aim of this systematic review and meta-analysis is to provide a comprehensive overview of the effect of CGM on glycaemic control in adults with type 2 diabetes. Methods: We performed a systematic review using Embase, MEDLINE, Web of Science, Scopus and ClinicalTrials.gov from inception until 2 May 2023. We included RCTs investigating real-time CGM (rtCGM) or intermittently scanned CGM (isCGM) compared with self-monitoring of blood glucose (SMBG) in adults with type 2 diabetes. Studies with an intervention duration <6 weeks or investigating professional CGM, a combination of CGM and additional glucose-lowering treatment strategies or GlucoWatch were not eligible. Change in HbA 1c and the CGM metrics time in range (TIR), time below range (TBR), time above range (TAR) and glycaemic variability were extracted. We evaluated the risk of bias using the Cochrane risk-of-bias tool version 2. Data were synthesised by performing a meta-analysis. We also explored the effects of CGM on severe hypoglycaemia and micro- and macrovascular complications. Results: We found 12 RCTs comprising 1248 participants, with eight investigating rtCGM and four isCGM. Compared with SMBG, CGM use (rtCGM or isCGM) led to a mean difference (MD) in HbA 1c of −3.43 mmol/mol (−0.31%; 95% CI −4.75, −2.11, p <0.00001, I 2 =15%; moderate certainty). This effect was comparable in studies that included individuals using insulin with or without oral agents (MD −3.27 mmol/mol [−0.30%]; 95% CI −6.22, −0.31, p =0.03, I 2 =55%), and individuals using oral agents only (MD −3.22 mmol/mol [−0.29%]; 95% CI −5.39, −1.05, p =0.004, I 2 =0%). Use of rtCGM showed a trend towards a larger effect (MD −3.95 mmol/mol [−0.36%]; 95% CI −5.46 to −2.44, p <0.00001, I 2 =0%) than use of isCGM (MD −1.79 mmol/mol [−0.16%]; 95% CI −5.28, 1.69, p =0.31, I 2 =64%). CGM was also associated with an increase in TIR (+6.36%; 95% CI +2.48, +10.24, p =0.001, I 2 =9%) and a decrease in TBR (−0.66%; 95% CI −1.21, −0.12, p =0.02, I 2 =45%), TAR (−5.86%; 95% CI −10.88, −0.84, p =0.02, I 2 =37%) and glycaemic variability (−1.47%; 95% CI −2.94, −0.01, p =0.05, I 2 =0%). Three studies reported one or more events of severe hypoglycaemia and macrovascular complications. In comparison with SMBG, CGM use led to a non-statistically significant difference in the incidence of severe hypoglycaemia (RR 0.66, 95% CI 0.15, 3.00, p =0.57, I 2 =0%) and macrovascular complications (RR 1.54, 95% CI 0.42, 5.72, p =0.52, I 2 =29%). No trials reported data on microvascular complications. Conclusions/interpretation: CGM use compared with SMBG is associated with improvements in glycaemic control in adults with type 2 diabetes. However, all studies were open label. In addition, outcome data on incident severe hypoglycaemia and incident microvascular and macrovascular complications were scarce. Registration: This systematic review was registered on PROSPERO (ID CRD42023418005). Graphical Abstract:
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In ACCORD, compared with standard care, the intensive glycemic control group had increased hypoglycemia (10.5% vs 3.5%; P < .001), weight gain greater than 10% (28% vs 14%; P < .001), and mortality (5% vs 4%; hazard ratio, 1.22 [95% CI, 1.01-1.46]), prompting early trial discontinuation.
“In ACCORD, compared with the standard care group, the intensive glycemic control group had increased hypoglycemia (10.5% vs 3.5%; P < .001), weight gain greater than 10% (28% vs 14%; P < .001), and mortality (5% vs 4%; hazard ratio, 1.22 [95% CI, 1.01–1.46]), prompting early trial discontinuation.39,43”
From Diagnosis and Treatment of Type 2 Diabetes in Adults (2025) · cites this paper as [43]
Split into 2 atoms — 0 confirmed, 0 partially supported, 0 disputed, 0 misattributed, 2 unverifiable. Expand the claim to see per-atom verdicts.
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
RoB 2: a revised tool for assessing risk of bias in randomised trials
Sterne, J. A. C., Savović, J., Page, M. J., Elbers, R. G., Blencowe, N. S., Boutron, I., Cates, C. J., Cheng, H.-Y., Corbett, M. S., Eldridge, S. M., et al. (2019) · BMJ · doi:10.1136/bmj.l4898 · Cited by 33,583 · see citing works
Rayyan-a web and mobile app for systematic reviews.
Ouzzani, M., Hammady, H., Fedorowicz, Z., & Elmagarmid, A. (2016) · Systematic Reviews · doi:10.1186/s13643-016-0384-4 · Cited by 26,092 · see citing works
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,032 · cited 1× · see citing works
“%) was more than the current consensus of 5% minimal clinical relevant difference in TIR [34].”
BackgroundSelf-citationBeck, R. W., Riddlesworth, T. D., Ruedy, K., Ahmann, A., Haller, S., Kruger, D., McGill, J. B., Polonsky, W., Price, D., Aronoff, S., et al. (2017) · Annals of Internal Medicine · doi:10.7326/m16-2855 · Cited by 635 · see citing works
Martens, T., Beck, R. W., Bailey, R., Ruedy, K. J., Calhoun, P., Peters, A. L., Pop-Busui, R., Philis-Tsimikas, A., Bao, S., Umpierrez, G., et al. (2021) · JAMA · doi:10.1001/jama.2021.7444 · Cited by 543 · see citing works
Maiorino, M. I., Signoriello, S., Maio, A., Chiodini, P., Bellastella, G., Scappaticcio, L., Longo, M., Giugliano, D., & Esposito, K. (2020) · Diabetes Care · doi:10.2337/dc19-1459 · Cited by 364 · see citing works
Yoo, H. J., An, H. G., Park, S. Y., Ryu, O. H., Kim, H. Y., Seo, J. A., Hong, E. G., Shin, D. H., Kim, Y. H., Kim, S. G., et al. (2008) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2008.06.015 · Cited by 244 · see citing works
Janapala, R. N., Jayaraj, J. S., Fathima, N., Kashif, T., Usman, N., Dasari, A., Jahan, N., & Sachmechi, I. (2019) · Cureus · doi:10.7759/cureus.5634 · Cited by 117 · see citing works
Bergenstal, R. M., Mullen, D. M., Strock, E., Johnson, M. L., & Xi, M. X. (2022) · Journal of Diabetes and its Complications · doi:10.1016/j.jdiacomp.2021.108106 · Cited by 87 · see citing works
Castellana, M., Parisi, C., Di Molfetta, S., Di Gioia, L., Natalicchio, A., Perrini, S., Cignarelli, A., Laviola, L., & Giorgino, F. (2020) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2019-001092 · Cited by 84 · see citing works
Price, D. A., Deng, Q., Kipnes, M., & Beck, S. E. (2021) · Diabetes Therapy · doi:10.1007/s13300-021-01086-y · Cited by 77 · see citing works
Flagged first, then by citations
Research works printed but not linked: 21
- [1]Davies MJ Aroda VR Collins BS Management of hyperglycaemia in type 2 diabetes, 2022. A consensus report by the American Diabetes Association (ADA) and the European Association for the Study of Diabetes (EASD) Diabetologia 2022 65 1925 1966 10.1007/s00125-022-05787-2 36151309 PMC9510507 · DOI · Paper page
- [2]Czupryniak L Barkai L Bolgarska S Self-monitoring of blood glucose in diabetes: from evidence to clinical reality in Central and Eastern Europe - recommendations from the international Central-Eastern European expert group Diabetes Technol Ther 2014 16 460 475 10.1089/dia.2013.0302 24716890 PMC4074758 · DOI
- [3]Edelman SV Argento NB Pettus J Hirsch IB Clinical implications of real-time and intermittently scanned continuous glucose monitoring Diabetes Care 2018 41 11 2265 2274 10.2337/dc18-1150 30348844 · DOI
- [4]Battelino T Alexander CM Amiel SA Continuous glucose monitoring and metrics for clinical trials: an international consensus statement Lancet Diabetes Endocrinol 2023 11 1 42 57 10.1016/S2213-8587(22)00319-9 36493795 · DOI · Paper page
- [5]Jackson MA Ahmann A Shah VN Type 2 diabetes and the use of real-time continuous glucose monitoring Diabetes Technol Ther 2021 23 S1 S27 S34 10.1089/dia.2021.0007 33534631 PMC7957379 · DOI · Paper page
- [6]Park C Le QA The effectiveness of continuous glucose monitoring in patients with type 2 diabetes: a systematic review of literature and meta-analysis Diabetes Technol Ther 2018 20 9 613 621 10.1089/dia.2018.0177 30095980 · DOI
- [7]Poolsup N Suksomboon N Kyaw AM Systematic review and meta-analysis of the effectiveness of continuous glucose monitoring (CGM) on glucose control in diabetes Diabetol Metab Syndr 2013 5 1 1 10.1186/1758-5996-5-39 23876067 PMC3728077 · DOI · Paper page
- [9]Gandhi GY Kovalaske M Kudva Y Efficacy of continuous glucose monitoring in improving glycemic control and reducing hypoglycemia: a systematic review and meta-analysis of randomized trials J Diabetes Sci Technol 2011 5 4 952 965 10.1177/193229681100500419 21880239 PMC3192603 · DOI
- [12]Uhl S, Choure A, Rouse B, Loblack A, Reaven P (2023) Effectiveness of continuous glucose monitoring on metrics of glycemic control in type 2 diabetes mellitus: a systematic review and meta-analysis of randomized controlled trials. J Clin Endocrinol Metab (November):1–13. 10.1210/clinem/dgad652 37987208 · DOI · Paper page
- [13]Liberati A Altman DG Tetzlaff J The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration PLoS Med 2009 6 7 e1000100 10.1371/journal.pmed.1000100 19621070 PMC2707010 · DOI · Paper page
- [15]Tierney MJ Tamada JA Potts RO The GlucoWatch biographer: a frequent automatic and noninvasive glucose monitor Ann Med 2000 32 9 632 41 10.3109/07853890009002034 11209971 · DOI
- [17]Review Manager Web (RevMan Web). Version 5.4.1. The Cochrane Collaboration, 2020. Available from revman.cochrane.org
- [19]Egger M Smith GD Schneider M Minder C Bias in meta-analysis detected by a simple, graphical test Br Med J 1997 315 7109 629 634 10.1136/bmj.315.7109.629 9310563 PMC2127453 · DOI · Paper page
- [21]Ajjan RA Heller SR Everett CC Multicenter randomized trial of intermittently scanned continuous glucose monitoring versus self-monitoring of blood glucose in individuals with type 2 diabetes and recent-onset acute myocardial infarction: results of the LIBERATES trial Diabetes Care 2023 46 2 441 449 10.2337/dc22-1219 36516054 PMC9887626 · DOI · Paper page
- [23]Haak T Hanaire H Ajjan R Hermanns N Riveline J-P Rayman G Flash glucose-sensing technology as a replacement for blood glucose monitoring for the management of insulin-treated type 2 diabetes: a multicenter, open-label randomized controlled trial Diabetes Ther 2017 8 1 55 73 10.1007/s13300-016-0223-6 28000140 PMC5306122 · DOI · Paper page
- [24]Wada E Onoue T Kobayashi T Flash glucose monitoring helps achieve better glycemic control than conventional self-monitoring of blood glucose in non-insulin-treated type 2 diabetes: a randomized controlled trial BMJ Open Diabetes Res Care 2020 8 1 10 17 10.1136/bmjdrc-2019-001115 PMC7292039 32518063 · DOI · Paper page
- [25]Yaron M Roitman E Aharon-Hananel G Effect of flash glucose monitoring technology on glycemic control and treatment satisfaction in patients with type 2 diabetes Diabetes Care 2019 42 7 1178 1184 10.2337/dc18-0166 31036546 · DOI · Paper page
- [27]Cosson E Hamo-Tchatchouang E Dufaitre-Patouraux L Attali JR Pariès J Schaepelynck-Bélicar P Multicentre, randomised, controlled study of the impact of continuous sub-cutaneous glucose monitoring (GlucoDay®) on glycaemic control in type 1 and type 2 diabetes patients Diabetes Metab 2009 35 4 312 318 10.1016/j.diabet.2009.02.006 19560388 · DOI · Paper page
- [30]Vigersky RA Fonda SJ Chellappa M Walker MS Ehrhardt NM Short- and long-term effects of real-time continuous glucose monitoring in patients with type 2 diabetes Diabetes Care 2012 35 1 32 38 10.2337/dc11-1438 22100963 PMC3241321 · DOI
- [32]Moon SJ Kim KS Lee WJ Lee MY Vigersky R Park CY Efficacy of intermittent short-term use of a real-time continuous glucose monitoring system in non-insulin–treated patients with type 2 diabetes: a randomized controlled trial Diabetes Obes Metab 2023 25 1 110 120 10.1111/dom.14852 36053813 · DOI · Paper page
- [33]Teo E Hassan N Tam W Koh S Effectiveness of continuous glucose monitoring in maintaining glycaemic control among people with type 1 diabetes mellitus: a systematic review of randomised controlled trials and meta-analysis Diabetologia 2022 65 4 604 619 10.1007/s00125-021-05648-4 35141761 · DOI · Paper page
Cited by
Sorted by citations
7. Diabetes Technology: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s007 · Cited by 348 · see citing works
Diagnosis and Treatment of Type 2 Diabetes in Adults
Kalyani, R. R., Neumiller, J. J., Maruthur, N. M., & Wexler, D. J. (2025) · JAMA · doi:10.1001/jama.2025.5956 · Cited by 145 · see citing works
Lau, D., Manca, D. P., Singh, P., Perry, T., Olu-Jordan, I., Ryan Zhang, J., Rahim, G., Hagen, E. M., & Yeung, R. O. (2024) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2024.111899 · Cited by 32 · see citing works
Rizos, E. C., Markozannes, G., Charitakis, N., Filis, P., Stoimeni, A. E., Nørgaard, K., Ntzani, E. E., & Tsilidis, K. K. (2025) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2024.0599 · Cited by 18 · see citing works
Cangelosi, G., Conti, A., Caggianelli, G., Panella, M., Petrelli, F., Mancin, S., Ratti, M., & Masini, A. (2025) · Medicina · doi:10.3390/medicina61081403 · Cited by 14 · see citing works
Knopp, M. I., Castleman, A. M., Schwarz, A., Belger-Wallace, J., Falciglia, M., Zuzek, A., & Mendonca, E. (2025) · JMIR Diabetes · doi:10.2196/73446 · Cited by 2 · see citing works
Talaiti, M., Liao, X., Abulimiti, N., Zeng, M., & Wang, Y. (2026) · Journal of Diabetes Research · doi:10.1155/jdr/1464982
- Authors
- Jancev, M., Vissers, T. A. C. M., Visseren, F. L. J., van Bon, A. C., Serné, E. H., DeVries, J. H., de Valk, H. W., & van Sloten, T. T.
- Affiliations
- University Medical Center Utrecht (NL)
- Amsterdam University Medical Centers (NL)
- Venue
- Diabetologia
- Published
- 2024-02-16
- Volume
- 67
- Issue
- 5
- Pages
- 798-810
- ISSN
- 0012-186X (ISSN-L)
- 1432-0428
- PMC
- PMC10954850
- OpenAlex
- W4391884989
- Cited by
- 191
- References
- 11
- Citations by year
- 2026: 91 · 2025: 81 · 2024: 19
- FWCI
- 11.21
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Diabetologia (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Amsterdam UMC (VU Amsterdam) - Institutional Repository (publishedVersion, other-oa)
- Pure Amsterdam UMC (acceptedVersion, cc-by)
- Utrecht University Repository (Utrecht University) (submittedVersion, other-oa)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- continuous glucose monitoring, type 2 diabetes, glycemic control, HbA1c, self-monitoring of blood glucose, real-time CGM, flash glucose monitoring, time in range, hypoglycemia, glycemic variability, insulin therapy, oral glucose-lowering agents, microvascular complications, macrovascular complications, risk of bias, adults with diabetes
- MeSH terms
- Continuous Glucose Monitoring, Adult, Blood Glucose, Diabetes Mellitus, Type 2, Humans, Hypoglycemia, Hypoglycemic Agents, Blood Glucose Self-Monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review