Synthetic tests in French mountainous regions evaluate whether sparse clock observations improve geopotential reconstruction at high spatial resolution.
Overview
CoChat Summary
TL;DR
This paper uses synthetic tests to ask whether a small number of atomic-clock measurements can improve regional geopotential recovery beyond gravity data alone. In two French test areas, adding only a few tens of clock points (less than 1% of gravity data coverage) improved the disturbing-potential reconstruction, cutting bias by up to 2 orders of magnitude and reducing standard deviation by about a factor of 3.
Key findings
- In the Massif Central, using only 4,374 gravity points gave a disturbing-potential bias of about 0.041 m²/s² and rms of about 0.25 m²/s²; adding 33 clock/potential points improved the bias to about -0.002 m²/s² and the standard deviation to about 0.07 m²/s².
- In the Alps, using only 4,959 gravity points gave a bias of about 0.23 m²/s² and standard deviation of about 0.39 m²/s²; adding 32 clock/potential points improved these to about -0.069 m²/s² and 0.18 m²/s².
- The paper reports that only a few tens of clock data points, i.e. less than 1% of the gravity data coverage, are sufficient to obtain centimeter-level standard deviations and large improvements in bias.
- Increasing clock density tends to bring the standard deviation of potential differences toward the centimeter level, and the bias can be reduced by up to 2 orders of magnitude.
Methods
- Numerical simulation study using two French regions: the Massif Central and the Alps-Mediterranean area, with synthetic gravity disturbances and disturbing potential derived from the EIGEN-6C4 geopotential model truncated to degree/order 2000 and further filtered to focus on wavelengths of about 10 km and above.
- Synthetic data were generated at realistic spatial distributions: 4,374 gravity points and 33 potential points in the Massif Central; 4,959 gravity points and 32 potential points in the Alps. Clock points were placed where gravity coverage was sparse, with a minimum spacing greater than the correlation length (about 20 km).
- Reconstruction used least squares collocation (LSC) with a logarithmic stationary isotropic covariance function; performance was evaluated by comparing reconstructed and reference potential on a 10 km grid using residual bias and standard deviation/rms.
Limitations
- The paper explicitly states that this is a synthetic study and that real clock measurements would provide potential differences rather than direct absolute potential values; the authors assume these differences can be connected to reference point(s) without introducing additional bias.
- The covariance function is not perfectly consistent with the synthetic data generation, and the paper says this mismatch leaves some low-frequency content in the recovered potential; this is a stated source of modeling error.
- The authors note they did not optimize clock locations, and say such optimization would likely improve results but is beyond the scope of this work.
- Evident from the text: the study covers only two regions in France and uses numerical simulations, so the reported gains are not yet demonstrated with real clock observations.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
8 Valid · 0 Not valid · 4 Not checked · 65 Own results and interpretations
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“For example, two clocks with an accuracy of 10 -18 in terms of relative frequency shift would detect a 1-cm geoid height variation between them, corresponding to a geopotential variation Δ W”
- Also stated in: § 1 Introduction · plain
“of about 0 . 1 m 2 s -2 (for more details, see, e.g., Delva and Lodewyck 2013; Mai 2013; Petit et al. 2014).”
What the sources say
- Supportedcites Delva and Lodewyck 2013 source
Section 4.1 (p. 11) equates a relative frequency shift of about 5 × 10^-19 with a height difference of about 5 mm and a geopotential difference of about 0.05 m² s^-2. Doubling those order-of-magnitude correspondences gives the claimed 10^-18, 1 cm, and 0.1 m² s^-2. The paper presents this as a potential measurement capability, not a detection already made. (LLM, conf=0.91)
- Not matchedcites Mai 2013
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Not checked — no full text of the sourcecites Petit et al. 2014 source
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Also stated in: § 1 Introduction · plain
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“while local geological sources may lead to gravity signals up to ∼ 10 mGal (Yale et al. 1998; Bondarescu et al. 2012; Castaldo et al. 2014).”
What the sources say
- Not checked — no full text of the sourcecites Yale et al. 1998 source
- Supportedcites Bondarescu et al. 2012 sourceExperimental — accuracy not yet measured
Section 4.1 (p. 8) models a buried, denser sphere in the shallow crust and calculates a maximum gravity anomaly of approximately 12.6 mGal. This supports the citing sentence’s approximate 10 mGal scale for a local geological source; the value is from a synthetic example, not a stated universal upper limit. (LLM, conf=0.89)
- Partly supportedcites Castaldo et al. 2014 sourceExperimental — accuracy not yet measured
Section 4 describes a gravity anomaly generated by a local sulphide body at the Udden mine, supporting the geological-source part of the claim. The passages found do not give an anomaly amplitude of about 10 mGal; Section 3.1 mentions mGal only as a unit in a mass-estimation formula. (LLM, conf=0.83)
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
Every source the paper cites for this claim was checked and supports it.
In the paper
“To date, the best of these instruments reach a stability of 1 . 6 × 10 -18 (NIST, RIKEN + Univ. Tokyo, Hinkley et al. 2013) after 7 hours of integration time.”
What the sources say
- Supportedcites Hinkley et al. 2013 sourceExperimental — accuracy not yet measured
The paper reports that a comparison of two optical lattice clocks reached an instability of 1.6 × 10^-18 after seven hours of averaging (p. 1). Its results also give 25,000 seconds—approximately seven hours—for the same value (pp. 4, 6). (LLM, conf=0.94)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“When adding the 32 potential measurements, we note that the bias is improved by a factor 4 ( μ T ≈ -0 . 069 m 2 s -2 or -6 . 9 mm) and the standard deviation by a factor 2 ( σ T ≈ 0 . 18 m 2 s -2 or 1.8 cm).”
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“It should also be stressed that a trend appears in the reconstructed potential with respect to the original one when no clock data are added in both regions.”
hedgedstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
47 more claims
Create a free account to see all 77 claims and every source verdict.
- Probably not a substantial claim. 4
- It may state two separate claims as one. 21
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“It is interesting because it is characterized by smooth, moderate altitude mountains and volcanic plateaus, leading to variations of the gravitational field over a range of spatial scales.”
From Chronometric Geodesy: Methods and Applications (2019) · cites this paper as [65]
The cited source says what the claim attributes to it.
In the citing paper
“As shown in [65] only a very few percent of clock measurements compared to the number of needed gravity data is sufficient.”
From Chronometric Geodesy: Methods and Applications (2019) · cites this paper as [65]
The cited source says what the claim attributes to it.
In the citing paper
“To illustrate the potential benefits of clocks and GNSS in geodesy, the determination of the geopotential at high spatial resolution, about 10 km, was investigated in [65].”
From Chronometric Geodesy: Methods and Applications (2019) · cites this paper as [65]
In the citing paper
“With optical clock performance at the levels demonstrated here, these clocks now enable beyond-stateof-the-art geodetic measurements and fundamental physics studies 7,8,10,13,15 .”
From Atomic clock performance enabling geodesy below the centimetre level (2018) · cites this paper as [8]
Citations
Cites
The Classical Theory of Fields
Landau, L., Lifshitz, E., & Rarita, W. (1952) · Physics Today · doi:10.1063/1.3067575 · Cited by 5,740
Global Sea Floor Topography from Satellite Altimetry and Ship Depth Soundings
Smith, W. H. F., & Sandwell, D. T. (1997) · Science · doi:10.1126/science.277.5334.1956 · Cited by 4,709 · cited 1×
“Topography is obtained from the 30-m digital elevation model over France by IGN, completed with Smith and Sandwell (1997) bathymetry and SRTM data.”
MethodChou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828
An Atomic Clock with 10 –18 Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817 · cited 1×
“To date, the best of these instruments reach a stability of 1.6×10−18 (NIST, RIKEN + Univ. Tokyo, Hinkley et al. 2013) after 7 hours of integration time.”
BackgroundInfluentialSystematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780 · cited 1×
“More recently, an accuracy of 2.1 × 10−18 (JILA, Nicholson et al. 2015) has been obtained, equivalent to geopotential differences of 0.2 m2s−2, or 2 cm on the geoid.”
InfluentialGeodetic Reference System 1980
Moritz, H. (1992) · Bulletin G�od�sique · doi:10.1007/bf00989270 · Cited by 740 · cited 2×
“parameters of the geodetic reference system GRS80 (Moritz 1984).”
BackgroundMethodFirst GOCE gravity field models derived by three different approaches
Pail, R., Bruinsma, S., Migliaccio, F., Förste, C., Goiginger, H., Schuh, W.-D., Höck, E., Reguzzoni, M., Brockmann, J. M., Abrikosov, O., et al. (2011) · Journal of Geodesy · doi:10.1007/s00190-011-0467-x · Cited by 502 · cited 2×
“The potential is reconstructed with a centimetric accuracy at resolutions of the order of 100km from GRACE and GOCE satellite data (Pail et al. 2011; Bruinsma et al. 2014) and integrated from near-surface gravimetry for the shorter spatial scales.”
MethodFoerste, C., Bruinsma, S. L., Abrykosov, O., Lemoine, J.-M., Marty, J. C., Flechtner, F., Balmino, G., Barthelmes, F., & Biancale, R. (2014) · GFZ Data Services · doi:10.5880/icgem.2015.1 · Cited by 463
A clock network for geodesy and fundamental science
Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., et al. (2016) · Nature Communications · doi:10.1038/ncomms12443 · Cited by 460 · cited 2×
“Currently two methods are available for such comparisons, fiber links (Lisdat et al. 2016) and free space optical links (Deschênes et al. 2016).”
BackgroundMethodTscherning, C. C., & Rapp, R. H. (1974) · The Knowledge Bank (The Ohio State University) · Cited by 401
Research works printed but not linked: 4
- Duquenne H (1998) Qgf98, a new solution for the quasigeoid in France. In: Proceeding of the Second Continental Workshop on the Geoid in Europe. Reports of the Finnish Geodetic Institute, vol 98, pp 251–255
- Forsberg R, Tscherning CC (2008) An overview manual for the GRAVSOFT. University of Copenhagen, Denmark
- Gruber T (2009) Evaluation of the egm2008 gravity field by means of gps-levelling and sea surface topography solutions. External quality evaluation reports of EGM08, Newton’s Bulletin 4, Bureau Gravimétrique International (BGI) / International Geoid Service (IGeS)
- Neyman YM (1979) The variational method of physical geodesy. Bulletin géodésique. Nedra Publishers, Moscow
Cited by
Atomic clock performance enabling geodesy below the centimetre level
McGrew, W. F., Zhang, X., Fasano, R. J., Schäffer, S. A., Beloy, K., Nicolodi, D., Brown, R. C., Hinkley, N., Milani, G., Schioppo, M., et al. (2018) · Nature · doi:10.1038/s41586-018-0738-2 · Cited by 727
Test of general relativity by a pair of transportable optical lattice clocks
Takamoto, M., Ushijima, I., Ohmae, N., Yahagi, T., Kokado, K., Shinkai, H., & Katori, H. (2020) · Nature Photonics · doi:10.1038/s41566-020-0619-8 · Cited by 507
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
“A first study in the direction of gravity field modelling and geoid determination with simulated clock and GNSS measurements is the publication of Lion et al (2017), although the study never mentions that precise GNSS is an essential part of it.”
High Performance Clocks and Gravity Field Determination
Müller, J., Dirkx, D., Kopeikin, S. M., Lion, G., Panet, I., Petit, G., & Visser, P. N. A. M. (2017) · Space Science Reviews · doi:10.1007/s11214-017-0431-z · Cited by 101
“A more detailed study discussing the role of different parameters, such as the noise level in the data, effects of the resolution of gravity measurements and modeling errors can be found in [Lion et al., 2017], in which they consider realistic spatial samplings.”
BackgroundPoint-to-point stabilized optical frequency transfer with active optics
Dix-Matthews, B. P., Schediwy, S., Gozzard, D. R., Savalle, E., Esnault, F.-X., Lévèque, T., Gravestock, C., D’Mello, D., Karpathakis, S., Tobar, M. E., et al. (2021) · Nature Communications · doi:10.1038/s41467-020-20591-5 · Cited by 85
Metadata
- Authors
- Lion, G., Panet, I., Wolf, P., Guerlin, C., Bize, S., & Delva, P.
- Affiliations
- Centre National de la Recherche Scientifique (FR)
- Sorbonne Paris Cité (FR)
- Corresponding author
- Lion, G.
- Panet, I.
- Venue
- Journal of Geodesy
- Published
- 2017-01-11
- Volume
- 91
- Issue
- 6
- Pages
- 597-611
- ISSN
- 0949-7714 (ISSN-L)
- 1432-1394
- OpenAlex
- W2566162140
- Semantic Scholar
- ab8840179b50206d3b108e7160576859a6d98cf1
- Cited by
- 66
- References
- 58
- Citations by year
- 2026: 5 · 2025: 7 · 2024: 8 · 2023: 11 · 2022: 4 · 2021: 6 · 2020: 8 · 2019: 6 · 2018: 7 · 2017: 4
- FWCI
- 4.72
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Journal of Geodesy (publishedVersion, cc-by)
- arXiv (Cornell University) (submittedVersion)
- HAL (submittedVersion, cc-by)
- arXiv (Cornell University)
- Funders
- European Research Council (617553)
- Labex First-TF
- Topics
- Physical Sciences › Earth and Planetary Sciences › Geophysics › Geophysics and Gravity Measurements
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Engineering › Aerospace Engineering › GNSS positioning and interference
- Keywords
- atomic clock comparison, geoid height, gravimetric analysis, least squares collocation, synthetic data, measurement noise, data coverage, mountainous terrain, Massif Central, Alps
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-09-28, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-09-28 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of a high spatial resolution geopotential model using atomic clock comparisons. https://app.cochat.ai/papers/10.1007/s00190-016-0986-6
- The paper
- Lion, G., Panet, I., Wolf, P., Guerlin, C., Bize, S., & Delva, P. (2017). Determination of a high spatial resolution geopotential model using atomic clock comparisons. Journal of Geodesy. https://doi.org/10.1007/s00190-016-0986-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.