Development and application of lateral flow test strip technology for detection of infectious agents and chemical contaminants: a review
The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Food-Related Illness and Death in the United States
Mead, P. S., Slutsker, L., Dietz, V., McCaig, L. F., Bresee, J. S., Shapiro, C., Griffin, P. M., & Tauxe, R. V. (1999) · Emerging Infectious Diseases · doi:10.3201/eid0505.990502 · Cited by 7,235
Listeria Pathogenesis and Molecular Virulence Determinants
Vázquez-Boland, J. A., Kuhn, M., Berche, P., Chakraborty, T., Domı́nguez-Bernal, G., Goebel, W., González-Zorn, B., Wehland, J., & Kreft, J. (2001) · Clinical Microbiology Reviews · doi:10.1128/cmr.14.3.584-640.2001 · Cited by 2,152
Posthuma-Trumpie, G. A., Korf, J., & van Amerongen, A. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2287-2 · Cited by 1,540
Calisher, C. H., Karabatsos, N., Dalrymple, J. M., Shope, R. E., Porterfield, J. S., Westaway, E. G., & Brandt, W. E. (1989) · Journal of General Virology · doi:10.1099/0022-1317-70-1-37 · Cited by 893
Analytical methods for determination of mycotoxins: A review
Turner, N. W., Subrahmanyam, S., & Piletsky, S. A. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.11.010 · Cited by 879
A water-soluble cationic oligopyrene derivative: Spectroscopic studies and sensing applications
Chen, Y., Bai, H., Chen, Q., Li, C., & Shi, G. (2009) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.02.047 · Cited by 845
Production of Fumonisin Analogs by Fusarium Species
Rheeder, J. P., Marasas, W. F. O., & Vismer, H. F. (2002) · Applied and Environmental Microbiology · doi:10.1128/aem.68.5.2101-2105.2002 · Cited by 634
West Nile Virus: A Primer for the Clinician
Petersen, L. R., & Marfin, A. A. (2002) · Annals of Internal Medicine · doi:10.7326/0003-4819-137-3-200208060-00009 · Cited by 624
Predicting the global spread of H5N1 avian influenza
Kilpatrick, A. M., Chmura, A. A., Gibbons, D. W., Fleischer, R. C., Marra, P. P., & Daszak, P. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0609227103 · Cited by 578
McDaniel, T. K., & Kaper, J. B. (1997) · Molecular Microbiology · doi:10.1046/j.1365-2958.1997.2311591.x · Cited by 516
Cited by
Law, J. W.-F., Ab Mutalib, N.-S., Chan, K.-G., & Lee, L.-H. (2015) · Frontiers in Microbiology · doi:10.3389/fmicb.2014.00770 · Cited by 1,205
Koczula, K. M., & Gallotta, A. (2016) · Essays in Biochemistry · doi:10.1042/ebc20150012 · Cited by 1,147
Nanoparticle Probes for the Detection of Cancer Biomarkers, Cells, and Tissues by Fluorescence
Chinen, A. B., Guan, C. M., Ferrer, J. R., Barnaby, S. N., Merkel, T. J., & Mirkin, C. A. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00321 · Cited by 1,032
Designs, formats and applications of lateral flow assay: A literature review
Sajid, M., Kawde, A.-N., & Daud, M. (2015) · Journal of Saudi Chemical Society · doi:10.1016/j.jscs.2014.09.001 · Cited by 765
Lateral flow assays: Principles, designs and labels
Bahadır, E. B., & Sezgintürk, M. K. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.06.006 · Cited by 682
Tutorial: design and fabrication of nanoparticle-based lateral-flow immunoassays
Parolo, C., Sena-Torralba, A., Bergua, J. F., Calucho, E., Fuentes-Chust, C., Hu, L., Rivas, L., Álvarez-Diduk, R., Nguyen, E. P., Cinti, S., et al. (2020) · Nature Protocols · doi:10.1038/s41596-020-0357-x · Cited by 576
Nanomaterials for Sensing and Destroying Pesticides
Aragay, G., Pino, F., & Merkoçi, A. (2012) · Chemical Reviews · doi:10.1021/cr300020c · Cited by 573
Shrivastava, S., Trung, T. Q., & Lee, N.-E. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00319c · Cited by 497
Advances and challenges in biosensor-based diagnosis of infectious diseases
Sin, M. L., Mach, K. E., Wong, P. K., & Liao, J. C. (2014) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.2014.888313 · Cited by 435
Recent advances in high-sensitivity detection methods for paper-based lateral-flow assay
Nguyen, V.-T., Song, S., Park, S., & Joo, C. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112015 · Cited by 373
Spin-enhanced nanodiamond biosensing for ultrasensitive diagnostics
Miller, B. S., Bezinge, L., Gliddon, H. D., Huang, D., Dold, G., Gray, E. R., Heaney, J., Dobson, P. J., Nastouli, E., Morton, J. J. L., et al. (2020) · Nature · doi:10.1038/s41586-020-2917-1 · Cited by 360
Cellulose: from biocompatible to bioactive material
Credou, J., & Berthelot, T. (2014) · J. Mater. Chem. B · doi:10.1039/c4tb00431k · Cited by 335
Immunochromatographic methods in food analysis
Dzantiev, B. B., Byzova, N. A., Urusov, A. E., & Zherdev, A. V. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.11.007 · Cited by 333
A review of experimental aspects of electrochemical immunosensors
Ricci, F., Adornetto, G., & Palleschi, G. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.06.033 · Cited by 327
Cheng, N., Song, Y., Zeinhom, M. M. A., Chang, Y.-C., Sheng, L., Li, H., Du, D., Li, L., Zhu, M.-J., Luo, Y., et al. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b12734 · Cited by 301
Lateral-flow technology: From visual to instrumental
Mak, W. C., Beni, V., & Turner, A. P. F. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.10.017 · Cited by 264
Sher, M., Zhuang, R., Demirci, U., & Asghar, W. (2017) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2017.1285228 · Cited by 245
López-Marzo, A. M., & Merkoçi, A. (2016) · Lab on a Chip · doi:10.1039/c6lc00737f · Cited by 215
The design, fabrication, and applications of flexible biosensing devices
Xu, M., Obodo, D., & Yadavalli, V. K. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.10.019 · Cited by 208
“For instance, there has been interest in developing rapid paper-assays for nucleic acid testing (Ngom et al. 2010).”
BackgroundTowards Lateral Flow Quantitative Assays: Detection Approaches
Urusov, A. E., Zherdev, A. V., & Dzantiev, B. B. (2019) · Biosensors · doi:10.3390/bios9030089 · Cited by 202
Detecting Biothreat Agents: From Current Diagnostics to Developing Sensor Technologies
Walper, S. A., Lasarte Aragonés, G., Sapsford, K. E., Brown, C. W., Rowland, C. E., Breger, J. C., & Medintz, I. L. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00420 · Cited by 161
Diallo, K., Feteh, V. F., Ibe, L., Antonio, M., Caugant, D. A., du Plessis, M., Deghmane, A.-E., Feavers, I. M., Fernandez, K., Fox, L. M., et al. (2021) · EBioMedicine · doi:10.1016/j.ebiom.2021.103274 · Cited by 51
Self-citation
Metadata
- Authors
- Ngom, B., Guo, Y., Wang, X., & Bi, D.
- Venue
- Analytical and Bioanalytical Chemistry
- Published
- 2010-04-27
- Volume
- 397
- Issue
- 3
- Pages
- 1113-1135
- ISSN
- 1618-2642 (ISSN-L)
- 1618-2650
- OpenAlex
- W2060509802
- Cited by
- 386
- References
- 40
- FWCI
- 11.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.