Spectroscopic sensors for in-line bioprocess monitoring in research and pharmaceutical industrial application
The DOI matches its Crossref record; 112 of the 112 references it cites were found in a registry or an index.
Abstract
The use of spectroscopic sensors for bioprocess monitoring is a powerful tool within the process analytical technology (PAT) initiative of the US Food and Drug Administration. Spectroscopic sensors enable the simultaneous real-time bioprocess monitoring of various critical process parameters including biological, chemical, and physical variables during the entire biotechnological production process. This potential can be realized through the combination of spectroscopic measurements (UV/Vis spectroscopy, IR spectroscopy, fluorescence spectroscopy, and Raman spectroscopy) with multivariate data analysis to obtain relevant process information out of an enormous amount of data. This review summarizes the newest results from science and industry after the establishment of the PAT initiative and gives a critical overview of the most common in-line spectroscopic techniques. Examples are provided of the wide range of possible applications in upstream processing and downstream processing of spectroscopic sensors for real-time monitoring to optimize productivity and ensure product quality in the pharmaceutical industry.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Offline measurements are laborious, not immediate, require qualified manpower, and are prone to an increased risk of contamination (Claßen et al. 2017; Noll and Henkel 2020; Rösner et al. 2022).”
From Software sensors in the monitoring of microalgae cultivations (2024) · cites this paper as Claßen et al. 2017
In the citing paper
“One important bottleneck is the lack of suitable online sensors for the reliable monitoring of biological parameters, mostly concentrations of intracellular components, in microalgae bioprocesses.”
From Software sensors in the monitoring of microalgae cultivations (2024) · cites this paper as Claßen et al. 2017
In the citing paper
“On the other hand, biological variables can usually be measured only by applying sampling and tedious offline methods.”
From Software sensors in the monitoring of microalgae cultivations (2024) · cites this paper as Claßen et al. 2017
In the citing paper
“Unlike IR spectroscopy that is being used in industrial processes for several years, Raman spectroscopy is still in the stage of academic research (Claßen et al., 2017; Schulz, 2018).”
From Perspectives of fluorescence spectroscopy for online monitoring in microalgae industry (2022) · cites this paper as Claßen et al., 2017
In the citing paper
“This technique has two major drawbacks: the lack of specificity and can only be used in liquid and homogenous samples (Ulber et al., 2003; Claßen et al., 2017).”
From Perspectives of fluorescence spectroscopy for online monitoring in microalgae industry (2022) · cites this paper as Claßen et al., 2017
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Principles of Fluorescence Spectroscopy
Lakowicz, J. R. (1999) · Springer eBooks · doi:10.1007/978-1-4757-3061-6 · Cited by 26,947
Principles of Fluorescence Spectroscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-46312-4 · Cited by 19,339
Democracy Barometer. Methodology. Version 4.
Merkel, W., Bochsler, D., Bousbah, K., Bühlmann, M., Giebler, H., Hänni, M., Heyne, L., Müller, L., Ruth, S., & Weßels, B. (2004) · Intellectum (Universidad de La Sabana) · doi:10.1007/s13398-014-0173-7.2 · Cited by 2,331
Swinehart, D. F. (1962) · Journal of Chemical Education · doi:10.1021/ed039p333 · Cited by 1,969
Růžička, J., & Stewart, J. W. B. (1975) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)89421-0 · Cited by 1,511
A review of near infrared spectroscopy and chemometrics in pharmaceutical technologies
Roggo, Y., Chalus, P., Maurer, L., Lema-Martinez, C., Edmond, A., & Jent, N. (2007) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2007.03.023 · Cited by 1,131
Raman spectroscopy: Recent advancements, techniques and applications
Das, R. S., & Agrawal, Y. K. (2011) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2011.08.003 · Cited by 773
Process analytical technology (PAT) for biopharmaceutical products
Rathore, A. S., Bhambure, R., & Ghare, V. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3781-x · Cited by 368
Růžička, J., & Hansen, E. H. (1978) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)84498-6 · Cited by 323
Abu‐Absi, N. R., Kenty, B. M., Cuellar, M. E., Borys, M. C., Sakhamuri, S., Strachan, D. J., Hausladen, M. C., & Li, Z. J. (2011) · Biotechnology and Bioengineering · doi:10.1002/bit.23023 · Cited by 322
Research works printed but not linked: 3
- FDA. Guidance for industry PAT — a framework for innovative pharmaceutical development, manufacuring, and quality assurance. Rockville: FDA; 2004. p. 16.
- Renaut P, Annarelli D. Evaluation of a new single-use UV sensor for protein a capture. Bioprocess Int. 2013;11:48–51.
- Moretto J, Smelko JP, Cuellar M, Berry B, Doane A, Ryll T, et al. Process Raman spectroscopy for in-line CHO cell culture monitoring. Am Pharm Rev. 2011;14:18–25.
Cited by
Items 101–175 of 175
Wilbert, D., Voigt, M., & Jaeger, M. (2025) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-025-05945-6 · Cited by 6
Urniežius, R., Masaitis, D., Levišauskas, D., Survyla, A., Babilius, P., & Godoladze, D. (2023) · Computational and Structural Biotechnology Journal · doi:10.1016/j.csbj.2023.11.033 · Cited by 5
Enhancing real‐time cell culture monitoring: Automated Raman model optimization with Taguchi method
Dong, X., Yan, X., Wan, Y., Gao, D., Jiao, J., Wang, H., & Qu, H. (2024) · Biotechnology and Bioengineering · doi:10.1002/bit.28688 · Cited by 7
Ergot alkaloid control in biotechnological processes and pharmaceuticals (a mini review)
Volnin, A., Parshikov, A., Tsybulko, N. S., Мизина, П. Г., & Sidelnikov, N. I. (2024) · Frontiers in Toxicology · doi:10.3389/ftox.2024.1463758 · Cited by 5
Hevaganinge, A., Weber, C. M., Filatova, A., Musser, A., Neri, A., Conway, J., Yuan, Y., Cattaneo, M. V., Clyne, A. M., & Yang, T. (2023) · ACS Omega · doi:10.1021/acsomega.3c00861 · Cited by 4
Nishita, S., & Onoe, H. (2024) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2024.115063 · Cited by 5
Farshchi, F., Ghaffarzadeh, S., Hasanzadeh, M., & Shadjou, N. (2024) · Journal of Photochemistry and Photobiology A Chemistry · doi:10.1016/j.jphotochem.2024.116055 · Cited by 5
Biochemical monitoring of SARS-CoV-2 VLP production stages using MIR spectroscopy and chemometrics
Dias, F. M., Bernardino, T. C., Guardalini, L. G. O., Tanaka, J. L., Leme, J., Peinado, A. P., Quintilio, W., Jorge, S. A. C., & Núñez, E. G. F. (2024) · Process Biochemistry · doi:10.1016/j.procbio.2024.10.006 · Cited by 6
Culture medium density as a simple monitoring tool for cell integrity of Escherichia coli
Kastenhofer, J., & Spadiut, O. (2020) · Journal of Biotechnology · doi:10.1016/j.btecx.2020.100017 · Cited by 6
Schott, C., Bley, T., Walter, T., Brusius, J., & Steingroewer, J. (2021) · Engineering in Life Sciences · doi:10.1002/elsc.202100086 · Cited by 5
Control of Continuous Manufacturing Processes for Production of Monoclonal Antibodies
Rathore, A. S., Thakur, G., Nikita, S., & Banerjee, S. (2021) · Wiley eBooks · doi:10.1002/9783527827343.ch2 · Cited by 6
Zhou, L. (2026) · Microchemical Journal · doi:10.1016/j.microc.2026.117999 · Cited by 4
UV Derivative Spectroscopy: A Comprehensive Review for Advancement in Quantification
Chandarana, C. V., Juwarwala, I., & Shinde, R. (2025) · Pharmaceutical Chemistry Journal · doi:10.1007/s11094-025-03335-x · Cited by 4
Hara, R., Kobayashi, W., Yamanaka, H., Murayama, K., Shimoda, S., & Ozaki, Y. (2023) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-023-05065-z · Cited by 7
Testa, G., Persichetti, G., & Bernini, R. (2024) · Sensors and Actuators Reports · doi:10.1016/j.snr.2024.100190 · Cited by 4
Boateng, B. O., & Ryder, A. G. (2024) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2024.10.002 · Cited by 4
Guetatlia, H. N., Gette, M., Estrade, L., Rimbaud, V., Denis, F., Rochefort, G. Y., & Renaud, M. (2026) · Diagnostics · doi:10.3390/diagnostics16020222 · Cited by 5
Zhao, M., Tang, Z., Zhou, M., Zhang, X., Wang, X., & Gong, X. (2026) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2026.127507 · Cited by 4
Process Development for Biologics Therapeutics
Bhatnagar, A., Hazra, P. P., Pai, H. V., Vajpai, N., Ramani, K., & Govindappa, N. (2025) · Springer eBooks · doi:10.1007/978-3-031-81787-8_6 · Cited by 5
Bioprocess Automation with Robotics: Streamlining Microbiology for Biotech Industry
Shajahan, M. A. (2022) · Asia Pacific Journal of Energy and Environment · doi:10.18034/apjee.v9i2.748 · Cited by 5
Inline and Online Process Analytical Technology with a Focus on Optical Spectroscopy
Kessler, R. W., Maiwald, M., & Kessler, W. (2022) · Wiley eBooks · doi:10.1002/9780470027318.a9791 · Cited by 3
Essential Number of Principal Components and Nearly Training-Free Model for Spectral Analysis
Bie, Y., You, S., Li, X., Zhang, X., & Lű, T. (2024) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2024.3436860 · Cited by 2
Shoshi, A., Gündüz, B., & Miehe, R. (2024) · Procedia CIRP · doi:10.1016/j.procir.2024.08.276 · Cited by 4
Dias, V. A. T., da Silva, J. D., Rabello, J. P., Barrance, F. A. C., Teruya, M. M., Taciro, M. K., Jacobus, A. P., Leme, J., Bernardino, T. C., Jorge, S. A. C., et al. (2025) · Journal of Fluorescence · doi:10.1007/s10895-025-04559-6 · Cited by 2
Dzurendová, S., Losada, C. B., Dupuy-Galet, B. X., Slaný, O., Fjær, K., Bartolomeo, F. D., Markussen, S., Wentzel, A., Várnai, A., Hansen, L. D., et al. (2025) · Microbial Cell Factories · doi:10.1186/s12934-025-02868-w · Cited by 2
Gaikwad, A. S., B.Pawar, S., & Rajguru, M. K. (2026) · Journal of Pharmaceutical Innovation · doi:10.1007/s12247-026-10841-2 · Cited by 2
Paiva, C. S., Radi, H. E., Chagas, D., Grollier, K., Cailletaud, J., Delacroix, S., Gabaldi, P., Faria, T. Q., & Peixoto, C. (2026) · Pharmaceutics · doi:10.3390/pharmaceutics18081016 · Cited by 2
Pino, C., Castillo, R. D. P., Mundaca‐Uribe, R., Mendez-Herrera, P., Aranda, M., & Peña‐Farfal, C. (2021) · Journal of the Chilean Chemical Society · doi:10.4067/s0717-97072021000405387 · Cited by 2
Identification and characterization techniques for engineered nanomaterials in food
Joshi, T. J., Harsha, V., Anitha Krishnan, V. C., & Ashok, A. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-85791-8.00018-5 · Cited by 3
ZnO based Back- and Front-Illuminated Photoresistor for UV Sensing Applications
Buzzin, A., Grossi, F., Cannatà, D., Benetti, M., de Cesare, G., & Caliendo, C. (2023) · International Workshop on Advances in Sensors and Interfaces (IWASI) · doi:10.1109/iwasi58316.2023.10164377 · Cited by 3
Torres, A. J. (2023) · Biotechnology Journal · doi:10.1002/biot.202300271 · Cited by 2
MIR spectroscopy in ATR mode for Sf9 insect cell line biochemical monitoring in bioprocesses
Guardalini, L. G. O., da Trindade, G. M., Leme, J., Bernardino, T. C., Peinado, A. P., Quintilio, W., Jorge, S. A. C., & Núñez, E. G. F. (2025) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2025.126174 · Cited by 2
da Silva, J. D., Dias, V. A. T., Rabello, J. P., Barrance, F. A. C., Teruya, M. M., Taciro, M. K., Jacobus, A. P., Leme, J., Bernardino, T. C., Jorge, S. A. C., et al. (2025) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2025.126663 · Cited by 2
Alemneh, S. T., Emire, S. A., Jekle, M., Paquet‐Durand, O., & Hitzmann, B. (2022) · International Electronic Conference on Processes (ECP) · doi:10.3390/ecp2022-12650 · Cited by 2
Roch, P. (2019) · Linköping studies in science and technology. Dissertations · doi:10.3384/diss.diva-160524 · Cited by 2
Corsi, F., & Morasso, C. (2021) · Oncotarget · doi:10.18632/oncotarget.27912 · Cited by 2
Narayanan, H., von Stosch, M., Luna, M. F., Bournazou, M. N. C., Butté, A., & Sokolov, M. (2021) · Wiley eBooks · doi:10.1002/9783527827343.ch8 · Cited by 3
Berg, C., Busch, S., Alawiyah, M. D., Finger, M., Ihling, N., Paquet‐Durand, O., Hitzmann, B., & Büchs, J. (2023) · Biotechnology and Bioengineering · doi:10.1002/bit.28474 · Cited by 1
Janssen, S. A. J., de Jong, A. M., & Prins, M. W. J. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.117808 · Cited by 1
Boateng, B. O., & Ryder, A. G. (2025) · Analytica Chimica Acta · doi:10.1016/j.aca.2025.344894 · Cited by 2
Kattour, N., Louka, N., Yaghi, J., & Debs, E. (2026) · Food Engineering Reviews · doi:10.1007/s12393-025-09434-5 · Cited by 1
Chemometrics, Infrared Sensors and Precision Fermentation – Where are We?
Alagappan, S., Nastasi, J. R., Hoffman, L. C., & Cozzolino, D. (2026) · Food Reviews International · doi:10.1080/87559129.2026.2643455 · Cited by 1
Ziémons, E., Hubert, C., & Hubert, P. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-409547-2.14051-x · Cited by 1
Advancement of sensor technology for monitoring and control of upstream bioprocesses
Randek, J. (2020) · Linköping studies in science and technology. Dissertations · doi:10.3384/diss.diva-165116 · Cited by 2
Chemometric methods in pharmaceutical technology
Djuriš, J., Kurćubić, I., Ibric, S. R., & Đurić, Z. (2023) · Elsevier eBooks · doi:10.1016/b978-0-443-18655-4.00006-6 · Cited by 2
Nagraik, T., Salcedo, A. G., Solle, D., & Scheper, T. H. (2020) · Journal of Visualized Experiments · doi:10.3791/60577 · Cited by 3
Self-citationEnzyme Cascade Reaction Monitoring and Control
Hiessl, R., Kleber, J., & Liese, A. (2021) · Springer eBooks · doi:10.1007/978-3-030-65718-5_9 · Cited by 1
Mesure en ligne par spectroscopie Raman appliquée à un photobioréacteur de microalgues
Lieutaud, C. (2019) · theses.fr (ABES) · doi:10.70675/b149f935zc54az4f46z877az5412eeee4d12 · Cited by 2
Autofluorescence spectroscopy for determining cell confluencyPreprint
Yong, D., Rahim, A. A. B. A., Ong, J., & Naing, M. W. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1804.05548
Whang, K., Chang, J., Jung, K., Ko, H., Lee, J., Choi, I., & Kang, T. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b03439
Martín, F. E. (2006) · Ingeopres: Actualidad técnica de ingeniería civil, minería, geología y medio ambiente
Raman spectroscopy-based imaging in the food industry
Dumouilla, V., & Dussap, C. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-91158-0.00010-7 · Cited by 1
Andersen, P. V., Wubshet, S. G., Tzimorotas, D., Dankel, K. R., Afseth, N. K., Wold, J. P., & Rønning, S. B. (2025) · Research Square · doi:10.21203/rs.3.rs-6123711/v1
Offline Raman monitoring of SARS-CoV-2 VLP upstream stage using two culture media
Rabello, J. P., Fontes, I. D. S., Dias, F. M., Camalhonte, S. O., Guardalini, L. G. O., Tanaka, J. L., Leme, J., Bernardino, T. C., Sposito, F. S., Dias, E., et al. (2025) · Spectroscopy Letters · doi:10.1080/00387010.2025.2541638
Jesubalan, N. G., Nikita, S., Banerjee, S., Deore, N., Gupta, K., & Rathore, A. S. (2025) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2025.109514
Digital Monitoring of Microalgae Cultivation and Harvesting
Tai, J. C. K., Lim, K. H., Yahaya, E., & Pengarah, L. U. A. (2025) · International Conference on Green Energy, Computing and Sustainable Technology (GECOST) · doi:10.1109/gecost66002.2025.11324894
Tölle, S. R., Klinken, S., Elkhashap, A., Delvos, A., Vallery, H., Breitkreutz, J., & Stemmler, S. (2026) · Journal of Process Control · doi:10.1016/j.jprocont.2026.103655
Evaluation of Low-Field NMR as a PAT Technology for Upstream Bioprocess Monitoring
Gerzon, G., Fischer, C., Pennestri, M., Hunter, H. N., Anklin, C. G., Misra, R. P., Wilson, D., Sheng, Y., & Kirkitadze, M. D. (2026) · Pharmaceutical Research · doi:10.1007/s11095-026-04016-4
Raman-guided sample subset selection for cost-efficient offline calibration in bioprocesses
Wilms, T., Schwenke, F., King, R., & Knorn, S. (2026) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-026-03402-x · Cited by 1
Teruya, M. M., Rabello, J. P., Guardalini, L. G. O., Barrence, F. A. C., & Núñez, E. G. F. (2026) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-026-03301-1
Zavala-Ortiz, D. (2020) · theses.fr (ABES) · doi:10.70675/e6277893z01cdz4dffzb93ez648eb9156e59 · Cited by 1
Wang, Y., Li, L., Huang, Q., Zhou, W., Chen, L., Liu, T., & Lu, X. (2026) · Algal Research · doi:10.1016/j.algal.2026.104697
Microalgal Biofilms : An Experimental, Monitoring and Modeling Approach
Pereira, D. M. (2025) · theses.fr (ABES) · doi:10.70675/39584f0dza802z449azb515z0097f8282711
Process Analytical Technology in Upstream Mammalian Cell Cultures
Park, C.-H., Jeon, Y., Ramm, S., Pein‐Hackelbusch, M., & Lee, D.-Y. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-24738-5.00086-0
Ahmed, L. I., Taher, E. M., Fahim, K. M., Nadi, W. G., Khalefa, H. S., Badawy, M. S. E. M., & Mahmoud, G. A. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-40362-0.00010-1
An Embedded IoT Platform for Turbidity Monitoring in Bioprocesses
Baicu, L. M., & Andrei, M. (2026) · Electronics · doi:10.3390/electronics15143147
Mentana, A., & Nardelli, V. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-30132-2.00001-2
Ghodba, A., Valipour, M., Richelle, A., McCready, C., Ricardez‐Sandoval, L., & Budman, H. M. (2026) · Journal of Process Control · doi:10.1016/j.jprocont.2026.103816
Kashif, M., Keating, M. E., & Byrne, H. J. (2026) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2026.128685
Zhuo, H., Zeng, B., Ning, Y., Zhang, L., Tian, C., Yu, Q., & Qian, M. (2026) · Frontiers in Chemistry · doi:10.3389/fchem.2026.1914581
Jang, B. J., & Shin, H. S. (2026) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-026-03426-3
Process analytical technology (PAT) and real-time control in chemical manufacturing
Yan, Y. (2026) · Advances in Differential Equations and Control Processes · doi:10.59400/adecp3800
施瑩婷, Fang, K., Wu, S., Wan, Y., Pan, J., & 瞿海斌 (2026) · Journal of Pharmaceutical Innovation · doi:10.1007/s12247-026-11120-w
Regulatory considerations for polymeric nanofibers: A global perspective
Tiwari, P., Kadiri, S. K., Gaurav, P., & Dhanawat, M. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-41702-3.00003-9
Metadata
- Authors
- Claßen, J., Aupert, F., Reardon, K. F., Solle, D., & Scheper, T.
- Affiliations
- Leibniz University Hannover (DE)
- Colorado State University (US)
- Corresponding author
- Solle, Dörte
- Venue
- Analytical and Bioanalytical Chemistry
- Published
- 2016-11-30
- Volume
- 409
- Issue
- 3
- Pages
- 651-666
- ISSN
- 1618-2642 (ISSN-L)
- 1618-2650
- OpenAlex
- W2557238105
- Semantic Scholar
- 5284f2568f7c06b9f933323347e669240d772dfd
- Cited by
- 176
- References
- 112
- Citations by year
- 2026: 23 · 2025: 19 · 2024: 22 · 2023: 21 · 2022: 18 · 2021: 25 · 2020: 17 · 2019: 16 · 2018: 10 · 2017: 4
- FWCI
- 1.18
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical and Bioanalytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Environmental Science › Waste Management and Disposal › Water Quality Monitoring and Analysis
- Keywords
- spectroscopic sensors, bioprocess monitoring, process analytical technology, in-line monitoring, real-time monitoring, multivariate analysis, UV-Vis spectroscopy, infrared spectroscopy, fluorescence spectroscopy, Raman spectroscopy, upstream processing, downstream processing, pharmaceutical manufacturing, product quality control
- MeSH terms
- Biotechnology, Spectrum Analysis, Raman, Technology, Pharmaceutical, Biosensing Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.