Spectroscopic sensors for in-line bioprocess monitoring in research and pharmaceutical industrial application
The DOI matches its Crossref record; 112 of the 112 references it cites were found in a registry or an index.
Abstract
The use of spectroscopic sensors for bioprocess monitoring is a powerful tool within the process analytical technology (PAT) initiative of the US Food and Drug Administration. Spectroscopic sensors enable the simultaneous real-time bioprocess monitoring of various critical process parameters including biological, chemical, and physical variables during the entire biotechnological production process. This potential can be realized through the combination of spectroscopic measurements (UV/Vis spectroscopy, IR spectroscopy, fluorescence spectroscopy, and Raman spectroscopy) with multivariate data analysis to obtain relevant process information out of an enormous amount of data. This review summarizes the newest results from science and industry after the establishment of the PAT initiative and gives a critical overview of the most common in-line spectroscopic techniques. Examples are provided of the wide range of possible applications in upstream processing and downstream processing of spectroscopic sensors for real-time monitoring to optimize productivity and ensure product quality in the pharmaceutical industry.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Offline measurements are laborious, not immediate, require qualified manpower, and are prone to an increased risk of contamination (Claßen et al. 2017; Noll and Henkel 2020; Rösner et al. 2022).”
From Software sensors in the monitoring of microalgae cultivations (2024) · cites this paper as Claßen et al. 2017
In the citing paper
“One important bottleneck is the lack of suitable online sensors for the reliable monitoring of biological parameters, mostly concentrations of intracellular components, in microalgae bioprocesses.”
From Software sensors in the monitoring of microalgae cultivations (2024) · cites this paper as Claßen et al. 2017
In the citing paper
“On the other hand, biological variables can usually be measured only by applying sampling and tedious offline methods.”
From Software sensors in the monitoring of microalgae cultivations (2024) · cites this paper as Claßen et al. 2017
In the citing paper
“Unlike IR spectroscopy that is being used in industrial processes for several years, Raman spectroscopy is still in the stage of academic research (Claßen et al., 2017; Schulz, 2018).”
From Perspectives of fluorescence spectroscopy for online monitoring in microalgae industry (2022) · cites this paper as Claßen et al., 2017
In the citing paper
“This technique has two major drawbacks: the lack of specificity and can only be used in liquid and homogenous samples (Ulber et al., 2003; Claßen et al., 2017).”
From Perspectives of fluorescence spectroscopy for online monitoring in microalgae industry (2022) · cites this paper as Claßen et al., 2017
Citations
Cites
Principles of Fluorescence Spectroscopy
Lakowicz, J. R. (1999) · Springer eBooks · doi:10.1007/978-1-4757-3061-6 · Cited by 26,947
Principles of Fluorescence Spectroscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-46312-4 · Cited by 19,339
Democracy Barometer. Methodology. Version 4.
Merkel, W., Bochsler, D., Bousbah, K., Bühlmann, M., Giebler, H., Hänni, M., Heyne, L., Müller, L., Ruth, S., & Weßels, B. (2004) · Intellectum (Universidad de La Sabana) · doi:10.1007/s13398-014-0173-7.2 · Cited by 2,331
Swinehart, D. F. (1962) · Journal of Chemical Education · doi:10.1021/ed039p333 · Cited by 1,969
Růžička, J., & Stewart, J. W. B. (1975) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)89421-0 · Cited by 1,511
A review of near infrared spectroscopy and chemometrics in pharmaceutical technologies
Roggo, Y., Chalus, P., Maurer, L., Lema-Martinez, C., Edmond, A., & Jent, N. (2007) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2007.03.023 · Cited by 1,131
Raman spectroscopy: Recent advancements, techniques and applications
Das, R. S., & Agrawal, Y. K. (2011) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2011.08.003 · Cited by 773
Process analytical technology (PAT) for biopharmaceutical products
Rathore, A. S., Bhambure, R., & Ghare, V. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3781-x · Cited by 368
Růžička, J., & Hansen, E. H. (1978) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)84498-6 · Cited by 323
Abu‐Absi, N. R., Kenty, B. M., Cuellar, M. E., Borys, M. C., Sakhamuri, S., Strachan, D. J., Hausladen, M. C., & Li, Z. J. (2011) · Biotechnology and Bioengineering · doi:10.1002/bit.23023 · Cited by 322
Bioreactor monitoring with spectroscopy and chemometrics: a review
Lourenço, N. D., Lopes, J. A., Almeida, C. F., Sarraguça, M. C., & Pinheiro, H. M. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6073-9 · Cited by 275 · cited 3×
“Regions across 4000 cm bear functional groups with chloride or nitrogen atoms [16].”
BackgroundMethodInfluentialKensy, F., Zang, E., Faulhammer, C., Tan, R.-K., & Büchs, J. (2009) · Microbial Cell Factories · doi:10.1186/1475-2859-8-31 · Cited by 253
Sensor systems for bioprocess monitoring
Biechele, P., Busse, C., Solle, D., Scheper, T., & Reardon, K. (2015) · Engineering in Life Sciences · doi:10.1002/elsc.201500014 · Cited by 224 · cited 5×
“It includes a gas (aeration), a liquid (growth medium), and a solid phase (cells) [5].”
BackgroundInfluentialSelf-citationReal-time bioprocess monitoring
Vojinović, V., Cabral, J. M. S., & Fonseca, L. P. (2006) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2005.07.059 · Cited by 221
Samorski, M., Müller‐Newen, G., & Büchs, J. (2005) · Biotechnology and Bioengineering · doi:10.1002/bit.20573 · Cited by 179
Cervera, A. E., Petersen, N., Lantz, A. E., Larsen, A., & Gernaey, K. V. (2009) · Biotechnology Progress · doi:10.1002/btpr.280 · Cited by 175
Craven, S., Whelan, J., & Glennon, B. (2014) · Journal of Process Control · doi:10.1016/j.jprocont.2014.02.007 · Cited by 171
Sensitivity, Selectivity and Stability of Gas-Sensitive Metal-Oxide Nanostructures
Bochenkov, V. E., & Сергеев, Г. Б. (2010) · Cited by 166
Whelan, J., Craven, S., & Glennon, B. (2012) · Biotechnology Progress · doi:10.1002/btpr.1590 · Cited by 159 · cited 10×
“Sandor et al. implemented an in-line NIRS in several CHO cell cultivations in a 7.5-”
InfluentialIn situ sensor techniques in modern bioprocess monitoring
Beutel, S., & Henkel, S. (2011) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-011-3470-5 · Cited by 154
Berry, B. N., Dobrowsky, T. M., Timson, R. C., Kshirsagar, R., Ryll, T., & Wiltberger, K. (2016) · Biotechnology Progress · doi:10.1002/btpr.2205 · Cited by 135
Picard, A., Daniel, I., Montagnac, G., & Oger, P. (2006) · Extremophiles · doi:10.1007/s00792-006-0054-x · Cited by 123
On-Line Fermentation Monitoring by Mid-Infrared Spectroscopy
Mazarevica, G., Diewok, J., Baena, J. R., Rosenberg, E., & Lendl, B. (2004) · Applied Spectroscopy · doi:10.1366/0003702041389229 · Cited by 121
Fluorescence Spectroscopy and Chemometric Modeling for Bioprocess Monitoring
Faassen, S., & Hitzmann, B. (2015) · Sensors · doi:10.3390/s150510271 · Cited by 120 · cited 2×
“For more than 30 years, fluorescence spectroscopy has been used to monitor biotechnological processes [76].”
BackgroundProcess analytical technology: a critical view of the chemometricians
Pomerantsev, A. L., & Rodionova, O. Y. (2012) · Journal of Chemometrics · doi:10.1002/cem.2445 · Cited by 119
Future Aspects of Bioprocess Monitoring
Becker, T. M., Hitzmann, B., Muffler, K., Pörtner, R., Reardon, K. F., Stahl, F., & Ulber, R. (2006) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2006_036 · Cited by 115
Self-citationGeneric Raman‐based calibration models enabling real‐time monitoring of cell culture bioreactors
Mehdizadeh, H., Lauri, D., Karry, K. M., Moshgbar, M., Procopio‐Melino, R., & Drapeau, D. (2015) · Biotechnology Progress · doi:10.1002/btpr.2079 · Cited by 108
The potential of mid infrared spectroscopy (MIRS) for real time bioprocess monitoring
Roychoudhury, P., Harvey, L. M., & McNeil, B. W. J. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.04.086 · Cited by 107
Ödman, P., Johansen, C. L., Olsson, L., Gernaey, K. V., & Lantz, A. E. (2009) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2009.08.018 · Cited by 107
Kessler, W. (2006) · Wiley eBooks · doi:10.1002/9783527610037 · Cited by 97
Li, B., Ryan, P. W., Ray, B. H., Leister, K. J., Sirimuthu, N. M. S., & Ryder, A. G. (2010) · Biotechnology and Bioengineering · doi:10.1002/bit.22813 · Cited by 91
In situ 2D fluorometry and chemometric monitoring of mammalian cell cultures
Teixeira, A. P., Portugal, C. A. M., Carinhas, N., Dias, J. M. L., Crespo, J. P., Alves, P. M., Carrondo, M. J. T., & Oliveira, R. (2009) · Biotechnology and Bioengineering · doi:10.1002/bit.22125 · Cited by 90
Navrátil, M., Norberg, A., Lembrén, L., & Mandenius, C. (2004) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2004.07.013 · Cited by 87
In-line and real-time prediction of recombinant antibody titer by in situ Raman spectroscopy
André, S., Cristau, L. S., Gaillard, S., Devos, O., Calvosa, É., & Duponchel, L. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.08.050 · Cited by 82
Two-dimensional fluorescence spectroscopy: A novel approach for controlling fed-batch cultivations
Hantelmann, K., Kollecker, M., Hüll, D., Hitzmann, B., & Scheper, T. (2006) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2005.07.016 · Cited by 80 · cited 2×
“The ATR crystal must have a higher refraction index than the sample; a commonly used material is zinc selenide [62].”
BackgroundSelf-citationClavaud, M., Roggo, Y., Daeniken, R. V., Liebler, A., & Schwabe, J. O. (2013) · Talanta · doi:10.1016/j.talanta.2013.03.044 · Cited by 78
Roychoudhury, P., O’Kennedy, R. D., McNeil, B. W. J., & Harvey, L. M. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.03.011 · Cited by 77
Measurement, Monitoring, Modelling and Control of Bioprocesses
Mandenius, C., & Titchener-Hooker, N. J. (2013) · Advances in biochemical engineering, biotechnology · doi:10.1007/978-3-642-36838-7 · Cited by 75
Clementschitsch, F., Jürgen, K., Pötschacher, F., & Karl, B. (2005) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2005.05.030 · Cited by 73
Kessler, R. W. (2006) · Wiley eBooks · doi:10.1002/3527608990 · Cited by 73
Quantitative monitoring of yeast fermentation using Raman spectroscopy
Iversen, J. A., Berg, R. W., & Ahring, B. K. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-7897-2 · Cited by 70
Sandor, M., Rüdinger, F., Bienert, R., Grimm, C., Solle, D., & Scheper, T. H. (2013) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2013.08.002 · Cited by 68
Self-citationSchenk, J., Marison, I. W., & VONSTOCKAR, U. (2006) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2006.09.015 · Cited by 67
On-line biomass measurements in bioreactor cultivations: comparison study of two on-line probes
Kiviharju, K., Salonen, K., Moilanen, U., Meskanen, E., Leisola, M., & Eerikäinen, T. (2007) · Journal of Industrial Microbiology & Biotechnology · doi:10.1007/s10295-007-0233-5 · Cited by 66
Sensors in Disposable Bioreactors Status and Trends
Glindkamp, A., Riechers, D., Rehbock, C., Hitzmann, B., Scheper, T., & Reardon, K. F. (2009) · Advances in Biochemical Engineering/Biotechnology · doi:10.1007/10_2009_10 · Cited by 65
Self-citationHakemeyer, C., Strauss, U. T., Werz, S., José, G. E., Folque, F., & de Menezes, J. C. (2011) · Talanta · doi:10.1016/j.talanta.2011.12.042 · Cited by 65
Chemometrics applications in biotech processes: A review
Rathore, A. S., Bhushan, N., & Hadpe, S. R. (2011) · Biotechnology Progress · doi:10.1002/btpr.561 · Cited by 65
Bioanalytics: detailed insight into bioprocesses
Scheper, T. H., Hitzmann, B., Stärk, E., Ulber, R., Faurie, R., Sosnitza, P., & Reardon, K. F. (1999) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00612-1 · Cited by 62
Self-citationBoehl, D. (2003) · Journal of Biotechnology · doi:10.1016/s0168-1656(03)00189-5 · Cited by 62
An On‐Line Approach To Monitor Ethanol Fermentation Using FTIR Spectroscopy
Veale, E. L., Irudayaraj, J., & Demirci, A. (2007) · Biotechnology Progress · doi:10.1021/bp060306v · Cited by 61
Brestrich, N., Briskot, T., Osberghaus, A., & Hubbuch, J. (2014) · Biotechnology and Bioengineering · doi:10.1002/bit.25194 · Cited by 60
Application of process analytical technology for downstream purification of biotherapeutics
Rathore, A. S., & Kapoor, G. (2015) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.4447 · Cited by 56
Hisiger, S., & Jolicœur, M. (2005) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2005.03.004 · Cited by 56
Effects of copper on CHO cells: Insights from gene expression analyses
Yuk, I. H., Zhang, J. D., Ebeling, M., Berrera, M., Gomez, N., Werz, S., Meiringer, C., Shao, Z., Swanberg, J. C., Lee, K. H., et al. (2014) · Biotechnology Progress · doi:10.1002/btpr.1868 · Cited by 56
Selective high throughput protein quantification based on UV absorption spectra
Hansen, S. K., Jamali, B., & Hubbuch, J. (2013) · Biotechnology and Bioengineering · doi:10.1002/bit.24712 · Cited by 55
Ávila, T. C., Poppi, R. J., Lunardi, I., Tizei, P. A. G., & Pereira, G. A. G. (2012) · Biotechnology Progress · doi:10.1002/btpr.1615 · Cited by 55
Microfluidic reactor for continuous cultivation of Saccharomyces cerevisiae
Edlich, A., Magdanz, V., Rasch, D., Demming, S., Zadeh, S. A., Segura, R., Kähler, C. J., Radespiel, R., Büttgenbach, S., Franco‐Lara, E., et al. (2010) · Biotechnology Progress · doi:10.1002/btpr.449 · Cited by 54
Crowley, J. N., Arnold, S. A., Wood, N., Harvey, L. M., & McNeil, B. W. J. (2005) · Enzyme and Microbial Technology · doi:10.1016/j.enzmictec.2003.12.016 · Cited by 54
Ude, C., Schmidt-Hager, J., Findeis, M., John, G., Scheper, T., & Beutel, S. (2014) · Sensors · doi:10.3390/s140917390 · Cited by 53
Self-citationRhee, J. I., & Kang, T.-H. (2007) · Process Biochemistry · doi:10.1016/j.procbio.2007.05.007 · Cited by 52
Determination of cell mass and polymyxin using multi-wavelength fluorescence
Lantz, A. E., Jørgensen, P., Poulsen, E. C., Lindemann, C., & Lisbeth Olsson, A. (2005) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2005.08.007 · Cited by 52
Franco, V. G., Perin, J. C., Mantovani, V. E., & Goicoechea, H. C. (2005) · Talanta · doi:10.1016/j.talanta.2005.07.003 · Cited by 51
Petersen, N., Ödman, P., Padrell, A. E. C., Stocks, S., Lantz, A. E., & Gernaey, K. V. (2010) · Biotechnology Progress · doi:10.1002/btpr.288 · Cited by 48
Glassey, J. (2012) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2012_171 · Cited by 47
Henriques, J. G., Buziol, S., Stocker, E., Voogd, A., & de Menezes, J. C. (2009) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2009_11 · Cited by 47
Growth behavior of microorganisms using UV‐Vis spectroscopy: Escherichia coli
Alupoaei, C. E., & García‐Rubio, L. H. (2004) · Biotechnology and Bioengineering · doi:10.1002/bit.20001 · Cited by 47
Golabgir, A., & Herwig, C. (2016) · Chemie Ingenieur Technik · doi:10.1002/cite.201500101 · Cited by 47
Kornmann, H., Valentinotti, S., Duboc, P., Marison, I. W., & von Stockar, U. (2004) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2004.03.029 · Cited by 45
UV absorption‐based inverse modeling of protein chromatography
Hahn, T., Baumann, P., Huuk, T. C., Heuveline, V., & Hubbuch, J. J. (2015) · Engineering in Life Sciences · doi:10.1002/elsc.201400247 · Cited by 43
At-line mid infrared spectroscopy for monitoring downstream processing unit operations
Capito, F., Skudas, R., Kolmar, H., & Hunzinger, C. (2015) · Process Biochemistry · doi:10.1016/j.procbio.2015.03.005 · Cited by 41
Synchronous fluorescence spectroscopy as a novel tool to enable PAT applications in bioprocesses
Teixeira, A. P., Duarte, T. M., Carrondo, M. J. T., & Alves, P. M. (2011) · Biotechnology and Bioengineering · doi:10.1002/bit.23131 · Cited by 39
Surribas, A., Amigo, J. M., Coello, J., Montesinos, J. L. G., Valero, F., & Maspoch, S. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0355-z · Cited by 38
Real time in-line monitoring of large scale Bacillus fermentations with near-infrared spectroscopy
Alves-Rausch, J., Bienert, R., Grimm, C., & Bergmaier, D. (2014) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2014.09.004 · Cited by 38
Assessment of near infrared and “software sensor” for biomass monitoring and control
Soons, Z. I. T. A., Streefland, M., Straten, G. V., & van Boxtel, A. J. B. (2008) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2008.07.009 · Cited by 37
A label‐free methodology for selective protein quantification by means of absorption measurements
Hansen, S. K., Skibsted, E., Staby, A., & Hubbuch, J. J. (2011) · Biotechnology and Bioengineering · doi:10.1002/bit.23229 · Cited by 37
Process Analytical Technology (PAT) and Multivariate Methods for Downstream Processes
Misra, N. N., Sullivan, C., & Cullen, P. J. (2015) · Current Biochemical Engineering · doi:10.2174/2213385203666150219231836 · Cited by 37
On-line parallel factor analysis. A step forward in the monitoring of bioprocesses in real time
Amigo, J. M., Surribas, A., Coello, J., Montesinos, J. L. G., Maspoch, S., & Valero, F. (2008) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2007.12.001 · Cited by 35
Characterization of Escherichia coli suspensions using UV/Vis/NIR absorption spectroscopy
Kiefer, J., Ebel, N., Schlücker, E., & Leipertz, A. (2009) · Analytical Methods · doi:10.1039/b9ay00185a · Cited by 35
Rodrigues, L. M., VIEIRA, L., CARDOSO, J., & de Menezes, J. C. (2008) · Talanta · doi:10.1016/j.talanta.2008.01.048 · Cited by 34
Quantification of protein mixture in chromatographic separation using multi‐wavelength UV spectra
Kamga, M., Lee, H. W., Liu, J. J., & Yoon, S. (2013) · Biotechnology Progress · doi:10.1002/btpr.1712 · Cited by 33
Haack, M. B., Lantz, A. E., Mortensen, P. P., & Lisbeth Olsson, A. (2006) · Biotechnology and Bioengineering · doi:10.1002/bit.21170 · Cited by 33
Goldfeld, M., Christensen, J., Pollard, D. J., Gibson, E. R., Olesberg, J. T., Koerperick, E. J., Lanz, K. J., Small, G. W., Arnold, M. A., & Evans, C. E. (2014) · Biotechnology Progress · doi:10.1002/btpr.1890 · Cited by 32
Qiu, J., Arnold, M. A., & Murhammer, D. W. (2014) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2014.01.009 · Cited by 32
Ganzlin, M., Marose, S., Lü, X., Hitzmann, B., Scheper, T. H., & Rinas, U. (2007) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2007.08.032 · Cited by 31
Self-citationpH prediction and control in bioprocesses using mid‐infrared spectroscopy
Schenk, J., Marison, I. W., & von Stockar, U. (2008) · Biotechnology and Bioengineering · doi:10.1002/bit.21719 · Cited by 29
Biomass estimation using fluorescence measurements in Pichia pastoris bioprocess
Surribas, A., Montesinos, J. L. G., & Valero, F. (2005) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.1352 · Cited by 29
Getting ready for PAT: Scale up and inline monitoring of protein refolding of Npro fusion proteins
Walther, C., Mayer, S., Jungbauer, A., & Dürauer, A. (2014) · Process Biochemistry · doi:10.1016/j.procbio.2014.03.022 · Cited by 29
Rathore, A. S., Li, X., Wojciech, B., Sharma, A., & Lu, Y. (2009) · Biotechnology Progress · doi:10.1002/btpr.212 · Cited by 28
Jain, G., Jayaraman, G., Kökpınar, Ö., Rinas, U., & Hitzmann, B. (2011) · Biochemical Engineering Journal · doi:10.1016/j.bej.2011.09.005 · Cited by 28
Johansson, L. Y., & Lidén, G. (2006) · Biotechnology Progress · doi:10.1021/bp060061m · Cited by 27
Streefland, M., Herpen, P. F. G. V., van de Waterbeemd, B., van der Pol, L. A., Beuvery, E. C., TRAMPER, J., Martens, D. E., & Toft, M. (2009) · Biotechnology and Bioengineering · doi:10.1002/bit.22425 · Cited by 26
In situ monitoring of the seed stage of a fermentation process using non-invasive NIR spectrometry
Nordon, A., Littlejohn, D., Dann, A. S., Jeffkins, P. A., Richardson, M. D., & Stimpson, S. L. (2008) · The Analyst · doi:10.1039/b719318a · Cited by 26
Schenk, J., Marison, I. W., & von Stockar, U. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.03.056 · Cited by 25
In situ quantification of microcarrier animal cell cultures using near-infrared spectroscopy
Petiot, E., Bernard-Moulin, P., Magadoux, T., Gény, C., Pinton, H., & Marc, A. (2010) · Process Biochemistry · doi:10.1016/j.procbio.2010.05.005 · Cited by 23
Ashton, L., Hogwood, C. E. M., Tait, A. S., Kuligowski, J., Smales, C. M., Bracewell, D. G., Dickson, A. J., & Goodacre, R. (2014) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.4420 · Cited by 22
Monitoring microaerobic denitrification of Pseudomonas aeruginosa by online NAD(P)H fluorescence
Ju, L., Chen, F., & Xia, Q. (2005) · Journal of Industrial Microbiology & Biotechnology · doi:10.1007/s10295-005-0035-6 · Cited by 22
Foley, R., Hennessy, S., & Marison, I. W. (2012) · Applied Spectroscopy · doi:10.1366/11-06395 · Cited by 19
Prozess Analytische Technologie in der Biotechnologie
Herwig, C. (2010) · Chemie Ingenieur Technik · doi:10.1002/cite.200900136 · Cited by 19
Forbes, R. A., Persinger, M. L., & Smith, D. R. (1996) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/s0731-7085(96)01875-4 · Cited by 18
In situ quantification of microcarrier animal cell cultures using near-infrared spectroscopy
Petiot, E., Bernard-Moulin, P., Magadoux, T., Gény, C., Pinton, H., & Marc, A. (2010) · Process Biochemistry · doi:10.1016/j.procbio.2010.08.010 · Cited by 17
Roychoudhury, P., McNeil, B. W. J., & Harvey, L. M. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.12.051 · Cited by 15
Rossi, D. M., Solle, D., Hitzmann, B., & Ayub, M. A. Z. (2012) · Journal of Industrial Microbiology & Biotechnology · doi:10.1007/s10295-011-1075-8 · Cited by 15
Self-citationScheper, T., & Reardon, K. F. (1991) · Wiley eBooks · doi:10.1002/9783527620142.ch9 · Cited by 14
Self-citationSchenk, J., Viscasillas, C., Marison, I. W., & von Stockar, U. (2008) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2007.12.014 · Cited by 14
Near-infrared spectroscopy in upstream bioprocesses
Hoehse, M., Alves-Rausch, J., Prediger, A., Roch, P., & Grimm, C. (2015) · Pharmaceutical Bioprocessing · doi:10.4155/pbp.15.1 · Cited by 13
Towards Process Spectroscopy in Complex Fermentation Samples and Mixtures
Paul, A., Carl, P., Westad, F., Voss, J., & Maiwald, M. (2016) · Chemie Ingenieur Technik · doi:10.1002/cite.201500118 · Cited by 13
Rodrigues, L. O., Cardoso, J. P., & de Menezes, J. C. (2008) · Biotechnology Progress · doi:10.1021/bp070328x · Cited by 12
Bonk, S., Sandor, M., Rüdinger, F., Tscheschke, B., Prediger, A., Babitzky, A., Solle, D., Beutel, S., & Scheper, T. (2011) · BMC Proceedings · doi:10.1186/1753-6561-5-s8-p76 · Cited by 11
Self-citationGahlawat, G., & Srivastava, A. K. (2012) · Applied Biochemistry and Biotechnology · doi:10.1007/s12010-012-0040-y · Cited by 7
Steady State Absorption Spectroscopy
Tkachenko, N. V. (2006) · Elsevier eBooks · doi:10.1016/b978-044452126-2/50029-0 · Cited by 5
Modelling, monitoring and control of plasmid bioproduction in Escherichia coli cultures
Lopes, M. B., Scholtz, T., Silva, D. P., Santos, I. C., Silva, T., Sampaio, P., Couto, A., Lopes, V. V., & Calado, C. R. C. (2012) · IEEE Portuguese Meeting on Bioengineering · doi:10.1109/enbeng.2012.6331370 · Cited by 3
Scheper, T., & Reardon, K. F. (1995) · doi:10.1002/9783527619269.ch9b · Cited by 3
Self-citation
Research works printed but not linked: 3
- FDA. Guidance for industry PAT — a framework for innovative pharmaceutical development, manufacuring, and quality assurance. Rockville: FDA; 2004. p. 16.
- Renaut P, Annarelli D. Evaluation of a new single-use UV sensor for protein a capture. Bioprocess Int. 2013;11:48–51.
- Moretto J, Smelko JP, Cuellar M, Berry B, Doane A, Ryll T, et al. Process Raman spectroscopy for in-line CHO cell culture monitoring. Am Pharm Rev. 2011;14:18–25.
Cited by
Digital Twins in Pharmaceutical and Biopharmaceutical Manufacturing: A Literature Review
Chen, Y., Yang, O., Sampat, C., Bhalode, P., Ramachandran, R., & Ierapetritou, M. (2020) · Processes · doi:10.3390/pr8091088 · Cited by 278
Bioprocessing in the Digital Age: The Role of Process Models
Narayanan, H., Luna, M. F., von Stosch, M., Cruz Bournazou, M. N., Polotti, G., Morbidelli, M., Butté, A., & Sokolov, M. (2020) · Biotechnology Journal · doi:10.1002/biot.201900172 · Cited by 247
Process Analytical Technologies – Advances in bioprocess integration and future perspectives
Gerzon, G., Sheng, Y., & Kirkitadze, M. (2022) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2021.114379 · Cited by 176
Gargalo, C. L., Udugama, I., Pontius, K., Lopez, P. C., Nielsen, R. F., Hasanzadeh, A., Mansouri, S. S., Bayer, C., Junicke, H., & Gernaey, K. V. (2020) · Journal of Industrial Microbiology and Biotechnology · doi:10.1007/s10295-020-02308-1 · Cited by 133
Destro, F., & Barolo, M. (2022) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2022.121715 · Cited by 152
Metadata
- Authors
- Claßen, J., Aupert, F., Reardon, K. F., Solle, D., & Scheper, T.
- Affiliations
- Leibniz University Hannover (DE)
- Colorado State University (US)
- Corresponding author
- Solle, Dörte
- Venue
- Analytical and Bioanalytical Chemistry
- Published
- 2016-11-30
- Volume
- 409
- Issue
- 3
- Pages
- 651-666
- ISSN
- 1618-2642 (ISSN-L)
- 1618-2650
- OpenAlex
- W2557238105
- Semantic Scholar
- 5284f2568f7c06b9f933323347e669240d772dfd
- Cited by
- 176
- References
- 112
- Citations by year
- 2026: 23 · 2025: 19 · 2024: 22 · 2023: 21 · 2022: 18 · 2021: 25 · 2020: 17 · 2019: 16 · 2018: 10 · 2017: 4
- FWCI
- 1.18
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical and Bioanalytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Environmental Science › Waste Management and Disposal › Water Quality Monitoring and Analysis
- Keywords
- spectroscopic sensors, bioprocess monitoring, process analytical technology, in-line monitoring, real-time monitoring, multivariate analysis, UV-Vis spectroscopy, infrared spectroscopy, fluorescence spectroscopy, Raman spectroscopy, upstream processing, downstream processing, pharmaceutical manufacturing, product quality control
- MeSH terms
- Biotechnology, Spectrum Analysis, Raman, Technology, Pharmaceutical, Biosensing Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.