Recent trends in smartphone-based detection for biomedical applications: a review
Open accessThe DOI matches its Crossref record; 83 of the 83 references it cites were found in a registry or an index.
Abstract
Smartphone-based imaging devices (SIDs) have shown to be versatile and have a wide range of biomedical applications. With the increasing demand for high-quality medical services, technological interventions such as portable devices that can be used in remote and resource-less conditions and have an impact on quantity and quality of care. Additionally, smartphone-based devices have shown their application in the field of teleimaging, food technology, education, etc. Depending on the application and imaging capability required, the optical arrangement of the SID varies which enables them to be used in multiple setups like bright-field, fluorescence, dark-field, and multiple arrays with certain changes in their optics and illumination. This comprehensive review discusses the numerous applications and development of SIDs towards histopathological examination, detection of bacteria and viruses, food technology, and routine diagnosis. Smartphone-based devices are complemented with deep learning methods to further increase the efficiency of the devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Molecular Detection of Tuberculosis and Rifampin Resistance
Boehme, C. C., Nabeta, P., Hillemann, D., Nicol, M. P., Shenai, S., Krapp, F., Allen, J., Tahirli, R., Blakemore, R., Rustomjee, R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa0907847 · Cited by 2,309
Histopathological Image Analysis: A Review
Gurcan, M. N., Boucheron, L. E., Can, A., Madabhushi, A., Rajpoot, N. M., & Yener, B. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2034865 · Cited by 2,052
Wound Microbiology and Associated Approaches to Wound Management
Bowler, P. G., Duerden, B. I., & Armstrong, D. G. (2001) · Clinical Microbiology Reviews · doi:10.1128/cmr.14.2.244-269.2001 · Cited by 1,634
Olthoff, K. M., Kulik, L., Samstein, B., Kaminski, M., Abecassis, M., Emond, J., Shaked, A., & Christie, J. D. (2010) · Liver Transplantation · doi:10.1002/lt.22091 · Cited by 1,256
A Review of Antibiotic Use in Food Animals: Perspective, Policy, and Potential
Landers, T. F., Cohen, B., Wittum, T. E., & Larson, E. L. (2012) · Public Health Reports® · doi:10.1177/003335491212700103 · Cited by 1,241
Azimi, M., Eslamlou, A., & Pekcan, G. (2020) · Sensors · doi:10.3390/s20102778 · Cited by 769
Critical evaluation of diagnostic aids for the detection of oral cancer
Lingen, M. W., Kalmar, J. R., Karrison, T., & Speight, P. M. (2008) · Oral Oncology · doi:10.1016/j.oraloncology.2007.06.011 · Cited by 718
Emerging Technologies for Next-Generation Point-of-Care Testing
Vashist, S. K., Luppa, P. B., Yeo, L. Y., Ozcan, A., & Luong, J. H. T. (2015) · Trends in Biotechnology · doi:10.1016/j.tibtech.2015.09.001 · Cited by 705
FLASH: A rapid method for prototyping paper-based microfluidic devices
Martinez, A. W., Phillips, S. T., Wiley, B. J., Gupta, M., & Whitesides, G. M. (2008) · Lab on a Chip · doi:10.1039/b811135a · Cited by 695
Fluorescent Imaging of Single Nanoparticles and Viruses on a Smart Phone
Wei, Q., Qi, H., Luo, W., Tseng, D., Ki, S. J., Wan, Z., Göröcs, Z., Bentolila, L. A., Wu, T.-T., Sun, R., et al. (2013) · ACS Nano · doi:10.1021/nn4037706 · Cited by 452
A smartphone dongle for diagnosis of infectious diseases at the point of care
Laksanasopin, T., Guo, T. W., Nayak, S., Sridhara, A. A., Xie, S., Olowookere, O. O., Cadinu, P., Meng, F., Chee, N. H., Kim, J., et al. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa0056 · Cited by 425
Neural Networks and Deep Learning: A Textbook
Aggarwal, C. C. (2018) · doi:10.1007/978-3-319-94463-0 · Cited by 417
Optofluidic Fluorescent Imaging Cytometry on a Cell Phone
Zhu, H., Mavandadi, S., Coskun, A. F., Yaglidere, O., & Ozcan, A. (2011) · Analytical Chemistry · doi:10.1021/ac201587a · Cited by 390
Conventional and emerging detection techniques for pathogenic bacteria in food science: A review
Hameed, S., Xie, L., & Ying, Y. (2018) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2018.05.020 · Cited by 386
Mobile phones democratize and cultivate next-generation imaging, diagnostics and measurement tools
Ozcan, A. (2014) · Lab Chip · doi:10.1039/c4lc00010b · Cited by 364
Smartphone-Based Food Diagnostic Technologies: A Review
Rateni, G., Dario, P., & Cavallo, F. (2017) · Sensors · doi:10.3390/s17061453 · Cited by 333
Cost-effective and compact wide-field fluorescent imaging on a cell-phone
Zhu, H., Yaglidere, O., Su, T.-W., Tseng, D., & Ozcan, A. (2011) · Lab Chip · doi:10.1039/c0lc00358a · Cited by 330
A smartphone-based diagnostic platform for rapid detection of Zika, chikungunya, and dengue viruses
Priye, A., Bird, S. W., Light, Y. K., Ball, C. S., Negrete, O. A., & Meagher, R. J. (2017) · Scientific Reports · doi:10.1038/srep44778 · Cited by 300
Automatic damage detection of historic masonry buildings based on mobile deep learning
Wang, N., Zhao, X., Zhao, P., Zhang, Y., Zou, Z., & Ou, J. (2019) · Automation in Construction · doi:10.1016/j.autcon.2019.03.003 · Cited by 285 · cited 1×
“Furthermore, a faster R-CNNmodel is used to detect the efflorescence and spalling in historical buildings to overcome the manual examination error which may destroy masonry structures [75].”
MethodA personalized food allergen testing platform on a cellphone
Coskun, A. F., Wong, J., Khodadadi, D., Nagi, R., Tey, A., & Ozcan, A. (2013) · Lab Chip · doi:10.1039/c2lc41152k · Cited by 280
Cost-effective and rapid blood analysis on a cell-phone
Zhu, H., Sencan, I., Wong, J., Dimitrov, S., Tseng, D., Nagashima, K., & Ozcan, A. (2013) · Lab on a Chip · doi:10.1039/c3lc41408f · Cited by 274
Chan, P., Wong, C., Poh, Y. C., Pun, L., Leung, W. W., Wong, Y., Wong, M. M., Poh, M., Chu, D. W., & Siu, C. (2016) · Journal of the American Heart Association · doi:10.1161/jaha.116.003428 · Cited by 240
Rubin's pathology : clinicopathologic foundations of medicine
Strayer, D. S., Rubin, E., Saffitz, J. E., & Schiller, A. L. (2012) · The Medicine Forum · Cited by 239
Point-of-care quantification of blood-borne filarial parasites with a mobile phone microscope
D’Ambrosio, M. V., Bakalar, M., Bennuru, S., Reber, C., Skandarajah, A., Nilsson, L., Switz, N., Kamgno, J., Pion, S., Boussinesq, M., et al. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa3480 · Cited by 237
Smartphone quantifies Salmonella from paper microfluidics
Park, T. S., Li, W., McCracken, K. E., & Yoon, J.-Y. (2013) · Lab on a Chip · doi:10.1039/c3lc50976a · Cited by 233
Roda, A., Michelini, E., Cevenini, L., Calabria, D., Calabretta, M. M., & Simoni, P. (2014) · Analytical Chemistry · doi:10.1021/ac502137s · Cited by 222
DFU_QUTNet: diabetic foot ulcer classification using novel deep convolutional neural network
Alzubaidi, L., Fadhel, M. A., Oleiwi, S. R., Al-Shamma, O., & Zhang, J. (2020) · Multimedia Tools and Applications · doi:10.1007/s11042-019-07820-w · Cited by 220
Recent approaches for optical smartphone sensing in resource-limited settings: a brief review
McCracken, K. E., & Yoon, J.-Y. (2016) · Analytical Methods · doi:10.1039/c6ay01575a · Cited by 216
Smartphone‐based clinical diagnostics: towards democratization of evidence‐based health care
Hernández‐Neuta, I., Neumann, F., Brightmeyer, J., Ba Tis, T., Madaboosi, N., Wei, Q., Ozcan, A., & Nilsson, M. (2019) · Journal of Internal Medicine · doi:10.1111/joim.12820 · Cited by 205
Yang, K., Peretz-Soroka, H., Liu, Y., & Lin, F. (2016) · Lab on a Chip · doi:10.1039/c5lc01524c · Cited by 198
Uthoff, R. D., Song, B., Sunny, S., Patrick, S., Suresh, A., Kolur, T., Keerthi, G., Spires, O., Anbarani, A., Wilder-Smith, P., et al. (2018) · PLOS ONE · doi:10.1371/journal.pone.0207493 · Cited by 192
Muehldorfer, S. M. (2002) · Gut · doi:10.1136/gut.50.4.465 · Cited by 174
A smartphone-based chip-scale microscope using ambient illumination
Lee, S. A., & Yang, C. (2014) · Lab on a Chip · doi:10.1039/c4lc00523f · Cited by 174
Imaging and Sizing of Single DNA Molecules on a Mobile Phone
Wei, Q., Luo, W., Chiang, S., Kappel, T., Mejia, C., Tseng, D., Chan, R. Y. L., Yan, E., Qi, H., Shabbir, F., et al. (2014) · ACS Nano · doi:10.1021/nn505821y · Cited by 169
Deep Learning Enhanced Mobile-Phone Microscopy
Rivenson, Y., Ceylan Koydemir, H., Wang, H., Wei, Z., Ren, Z., Günaydın, H., Zhang, Y., Göröcs, Z., Liang, K., Tseng, D., et al. (2018) · ACS Photonics · doi:10.1021/acsphotonics.8b00146 · Cited by 162
Ganguli, A., Ornob, A., Yu, H., Damhorst, G. L., Chen, W., Sun, F., Bhuiya, A. M., Cunningham, B. T., & Bashir, R. (2017) · Biomedical Microdevices · doi:10.1007/s10544-017-0209-9 · Cited by 157
Automated Low-Cost Smartphone-Based Lateral Flow Saliva Test Reader for Drugs-of-Abuse Detection
Carrio, A., Sampedro, C., Sánchez-López, J. L., Pimienta, M., & Campoy, P. (2015) · Sensors · doi:10.3390/s151129569 · Cited by 154
Air quality monitoring using mobile microscopy and machine learning
Wu, Y., Shiledar, A., Li, Y., Wong, J. T., Feng, S. W., Chen, X., Chen, C., Jin, K., Janamian, S., Yang, Z., et al. (2017) · Light Science & Applications · doi:10.1038/lsa.2017.46 · Cited by 150
Smartphone based non-invasive salivary glucose biosensor
Soni, A., & Jha, S. K. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.10.003 · Cited by 143
Automated screening of sickle cells using a smartphone-based microscope and deep learning
de Haan, K., Koydemir, H. C., Rivenson, Y., Tseng, D., Dyne, E. V., Bakic, L., Karinca, D., Liang, K., Ilango, M., Gumustekin, E., et al. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0282-y · Cited by 141
An iPhone-based digital image colorimeter for detecting tetracycline in milk
Masawat, P., Harfield, A., & Namwong, A. (2015) · Food Chemistry · doi:10.1016/j.foodchem.2015.03.089 · Cited by 131
Vaccinia virus in Feces and Urine of Wild Rodents from São Paulo State, Brazil
Peres, M. G., Bacchiega, T. S., Appolinário, C. M., Vicente, A. F., Mioni, M. D. S. R., Ribeiro, B., Fonseca, C., Pelícia, V. C., Ferreira, F., Abrahão, J. S., et al. (2018) · Viruses · doi:10.3390/v10020051 · Cited by 130
Yu, L. D., Shi, Z., Fang, C., Zhang, Y., Liu, Y., & Li, C. M. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.02.035 · Cited by 127
Hussain, I., Ahamad, K. U., & Nath, P. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03424 · Cited by 121
Self-citationThom, N. K., Lewis, G. G., Yeung, K., & Phillips, S. T. (2013) · RSC Advances · doi:10.1039/c3ra44717k · Cited by 117
Lee, S., Kim, G., & Moon, J.-H. (2013) · Sensors · doi:10.3390/s130405109 · Cited by 114
Fronczek, C. F., Park, T. S., Harshman, D. K., Nicolini, A. M., & Yoon, J. (2014) · RSC Advances · doi:10.1039/c3ra47688j · Cited by 111
Seismo: Blood Pressure Monitoring using Built-in Smartphone Accelerometer and Camera
Wang, E. J., Zhu, J., Jain, M., Lee, T.-J., Saba, E., Nachman, L., & Patel, S. (2018) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3173574.3173999 · Cited by 110 · cited 1×
“The device was compared to standard methods such as ECG or traditional PTT (pulse transit time) instruments and was found to have a high correlation to the previous methods [26].”
MethodTian, B., Qiu, Z., Ma, J., de la Torre, T. Z. G., Johansson, C., Svedlindh, P., & Strömberg, M. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.06.085 · Cited by 109
Smartphone-Based Fluorescent Diagnostic System for Highly Pathogenic H5N1 Viruses
Yeo, S., Choi, K., Cuc, B. T., Hồng, N. N., Duong, B. T., Ngoc, N. M., Le, M. Q., Hằng, N. L. K., Thach, N. C., Mallik, S. K., et al. (2015) · Theranostics · doi:10.7150/thno.14023 · Cited by 107
Rubin's Pathology, Clinicopathologic Foundations of Medicine
Kovach, A. E. (2008) · The American Journal of Surgical Pathology · doi:10.1097/pas.0b013e31816d7194 · Cited by 99
Liang, P.-S., Park, T. S., & Yoon, J. (2014) · Scientific Reports · doi:10.1038/srep05953 · Cited by 95
Mobile microscopy as a screening tool for oral cancer in India: A pilot study
Skandarajah, A., Sunny, S. P., Gurpur, P., Reber, C. D., D’Ambrosio, M. V., Raghavan, N., James, B. L., Ramanjinappa, R. D., Suresh, A., Kandasarma, U., et al. (2017) · PLoS ONE · doi:10.1371/journal.pone.0188440 · Cited by 92
Ludwig, S. K. J., Zhu, H., Phillips, S. W., Shiledar, A., Feng, S. W., Tseng, D. K., van Ginkel, L. A., Nielen, M. W. F., & Özcan, A. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-7984-4 · Cited by 90
Automated Tuberculosis Diagnosis Using Fluorescence Images from a Mobile Microscope
Chang, J., Arbeláez, P., Switz, N. A., Reber, C. D., Tapley, A., Davis, J. L., Cattamanchi, A., Fletcher, D. A., & Malik, J. (2012) · Lecture notes in computer science · doi:10.1007/978-3-642-33454-2_43 · Cited by 83
Smartphone-interfaced lab-on-a-chip devices for field-deployable enzyme-linked immunosorbent assay
Chen, A., Wang, R., Bever, C. S., Xing, S., Hammock, B. D., & Pan, T. (2014) · Biomicrofluidics · doi:10.1063/1.4901348 · Cited by 79
Roy, M., Jin, G., Seo, D., Nam, M., & Seo, S. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.05.011 · Cited by 74
Can the power of mobile phones be used to improve tuberculosis diagnosis in developing countries?
Zimic, M., Coronel, J., Gilman, R. H., Luna, C. G., Curioso, W. H., & Moore, D. A. J. (2009) · Transactions of the Royal Society of Tropical Medicine and Hygiene · doi:10.1016/j.trstmh.2008.10.015 · Cited by 68
Müller, V., Sousa, J. M., Koydemir, H. C., Veli, M., Tseng, D. K., Cerqueira, L., Özcan, A., Azevedo, N. F., & Westerlund, F. (2018) · RSC Advances · doi:10.1039/c8ra06473c · Cited by 68
Concepts in Light Microscopy of Viruses
Witte, R., Andriasyan, V., Georgi, F., Yakimovich, A., & Greber, U. F. (2018) · Viruses · doi:10.3390/v10040202 · Cited by 64
Li, L., Liu, Z., Zhang, H., Yue, W., Li, C., & Yi, C. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.07.074 · Cited by 64
Two-color multiphoton in vivo imaging with a femtosecond diamond Raman laser
Perillo, E. P., Jarrett, J. W., Liu, Y., Hassan, A. M., Fernée, D. C., Goldak, J. R., Bonteanu, A., Spence, D. J., Yeh, H., & Dunn, A. K. (2017) · Light Science & Applications · doi:10.1038/lsa.2017.95 · Cited by 61
Invited Review. Imaging of Single DNA Molecule: Applications to High-Resolution Genomic Studies
Herrick, J., & Bensimon, A. (1999) · Chromosome Research · doi:10.1023/a:1009276210892 · Cited by 60
Editors' Choice—Artificial Intelligence Based Mobile Application for Water Quality Monitoring
Gunda, N. S. K., Gautam, S. H., & Mitra, S. K. (2019) · Journal of The Electrochemical Society · doi:10.1149/2.0081909jes · Cited by 54
Shukla, S., Hong, S.-Y., Chung, S. H., & Kim, M. (2016) · Frontiers in Microbiology · doi:10.3389/fmicb.2016.01685 · Cited by 54
Wang, Y., Li, Y., Bao, X., Han, J., Xia, J., Tian, X., & Ni, L. (2016) · Talanta · doi:10.1016/j.talanta.2016.07.012 · Cited by 50
Smartphone-based pathogen diagnosis in urinary sepsis patients
Barnes, L., V, Heithoff, D. M., Mahan, S. P., Fox, G. N., Zambrano, A., Choe, J., Fitzgibbons, L. N., Marth, J. D., Fried, J., Soh, H. T., et al. (2018) · EBioMedicine · doi:10.1016/j.ebiom.2018.09.001 · Cited by 50
Fang, J., Qiu, X., Wan, Z., Zou, Q., Su, K., Hu, N., & Wang, P. (2016) · Analytical Methods · doi:10.1039/c6ay01384h · Cited by 45
Monošík, R., dos Santos, V. B., & Angnes, L. (2015) · Analytical Methods · doi:10.1039/c5ay01556a · Cited by 43
Dönmez, S. İ., Needs, S. H., Osborn, H. M. I., & Edwards, A. D. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.128645 · Cited by 40
The first use of the microscope in medicine.
Hajdu, S. I. (2002) · PubMed · Cited by 33
Multiple Protein Biomarker Assessment for Recombinant Bovine Somatotropin (rbST) Abuse in Cattle
Ludwig, S. K. J., Smits, N. G. E., van der Veer, G., Bremer, M. G. E. G., & Nielen, M. W. F. (2012) · PLoS ONE · doi:10.1371/journal.pone.0052917 · Cited by 28
A review of cellphone microscopy for disease detection
Dendere, R., MYBURG, N., & Douglas, T. S. (2015) · Journal of Microscopy · doi:10.1111/jmi.12307 · Cited by 28
Mora, C. A., Herzog, A. F., Raso, R. A., & Stark, W. J. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.04.054 · Cited by 26
Automatic Focus Assessment on Dermoscopic Images Acquired with Smartphones
Alves, J. E., Moreira, D., Alves, P., Rosado, L., & Vasconcelos, M. J. M. (2019) · Sensors · doi:10.3390/s19224957 · Cited by 24
Bornhorst, J., Nustede, E. J., & Fudickar, S. (2019) · Sensors · doi:10.3390/s19061468 · Cited by 22
Light emitting diode (LED) based fluorescence microscopy for tuberculosis detection: a review
Ojha, A., Banik, S., Melanthota, S. K., & Mazumder, N. (2020) · Lasers in Medical Science · doi:10.1007/s10103-019-02947-6 · Cited by 22
Self-citationDevelopment and characterization of portable smartphone‐based imaging device
Banik, S., Mahato, K. K., Antonini, A., & Mazumder, N. (2020) · Microscopy Research and Technique · doi:10.1002/jemt.23525 · Cited by 20
Self-citationCesaretti, M., Poté, N., Dondero, F., Cauchy, F., Schneck, A. S., Soubrane, O., Paradis, V., Diaspro, A., & Antonini, A. (2017) · Microscopy Research and Technique · doi:10.1002/jemt.22956 · Cited by 18
Cuesta, S. A., Sánchez-García, Á., Conejero, J. A., Sáez, C., Rivero-Rodriguez, A., & Garcia-Gomez, J. M. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16030461 · Cited by 15
enHealth, & Access, T. A. (2010) · Cited by 12
Screening of protein biomarkers for sports doping and veterinary control
Ludwig, S. K. J., van Ginkel, L. A., & Nielen, M. W. F. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.01.005 · Cited by 9
Jiang, J., Wang, X., Chao, R., Ren, Y., Hu, C., Xu, Z., & Liu, G. L. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.11.103
Cited by
Zehra, T., Parwani, A., Abdul-Ghafar, J., & Ahmad, Z. (2023) · Diagnostic Pathology · doi:10.1186/s13000-023-01352-6 · Cited by 43
Metadata
- Authors
- Banik, S., Melanthota, S. K., Arbaaz, Vaz, J. M., Kadambalithaya, V. M., Hussain, I., Dutta, S., & Mazumder, N.
- Venue
- Analytical and Bioanalytical Chemistry
- Published
- 2021-02-15
- Volume
- 413
- Issue
- 9
- Pages
- 2389-2406
- ISSN
- 1618-2642 (ISSN-L)
- 1618-2650
- OpenAlex
- W3131310148
- Cited by
- 173
- References
- 83
- FWCI
- 8.05
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.