Smartphone based non-invasive salivary glucose biosensor
Abstract
The present work deals with the development of a non-invasive optical glucose biosensor using saliva samples and a smartphone. The sensor was fabricated with a simple methodology by immobilization of Glucose oxidase enzyme along with a pH responsive dye on a filter paper based strip. The strip changes color upon reaction with glucose present in saliva and the color changes were detected using a smartphone camera through RGB profiling. This standalone biosensor showed good sensitivity and low interference while operating within 20 s response time. We used various means for improvements such as the use of slope method instead of differential response; use of a responsive pH indicator and made numerous tweaks in the smartphone app. Calibration with spiked saliva samples with slopes for (R + G + B) pixels revealed an exponentially increasing calibration curve with a linear detection range of 50-540 mg/dL, sensitivity of 0.0012 pixels sec-1/mg dL-1 and LOD of 24.6 mg/dL. The biosensor was clinically validated on both healthy and diabetic subjects divided into several categories based on sex, age, diabetic status etc. and correlation between blood and salivary glucose has been established for better standardization of the sensor. Correlation of 0.44 was obtained between blood and salivary glucose in healthy individuals whereas it was 0.64 and 0.94 in case of prediabetic and diabetic patients respectively. The developed biosensor has the potential to be used for mass diagnosis of diabetes especially in such areas where people remain prohibited from routine analysis due to high healthcare cost. Apart from that, a smartphone would be the only device the user needs for this measurement, along with a disposable low cost test strip.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Because saliva can be readily collected, it has been used in connection to in vitro diagnostic biosensors on strips or portable device platforms.
“Because saliva can be readily collected123-125, it has been used in connection to in vitro diagnostic biosensors on strips or portable device platforms,126-134.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [132]
Cites
PROTEIN MEASUREMENT WITH THE FOLIN PHENOL REAGENT
Lowry, O. H., Rosebrough, N., Farr, A. L., & Randall, R. (1951) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)52451-6 · Cited by 316,200 · see citing works
IDF Diabetes Atlas: Global estimates for the prevalence of diabetes for 2015 and 2040
Ogurtsova, K., Fernandes, J. D. D. R., Huang, Y., Linnenkamp, U., Guariguata, L., Cho, N. H., Cavan, D. A., Shaw, J. E., & Makaroff, L. (2017) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2017.03.024 · Cited by 7,008 · see citing works
Biosensors and bioelectronics on smartphone for portable biochemical detection
Zhang, D., & Liu, Q. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.037 · Cited by 651 · see citing works
Smartphone-based biosensors: A critical review and perspectives
Roda, A., Michelini, E., Zangheri, M., Di Fusco, M., Calabria, D., & Simoni, P. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.10.019 · Cited by 520 · see citing works
Zangheri, M., Cevenini, L., Anfossi, L., Baggiani, C., Simoni, P., Di Nardo, F., & Roda, A. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.08.048 · Cited by 373 · see citing works
Mobile Applications for Diabetes Self-Management: Status and Potential
El-Gayar, O., Timsina, P., Nawar, N., & Eid, W. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700130 · Cited by 370 · see citing works
Vashist, S. K., Schneider, E. M., & Luong, J. H. T. (2014) · Diagnostics · doi:10.3390/diagnostics4030104 · Cited by 247 · see citing works
Claussen, J. C., Kumar, A., Jaroch, D., Khawaja, M. H., Hibbard, A. B., Porterfield, D. M., & Fisher, T. S. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201200551 · Cited by 236 · see citing works
Barbosa, A. I., Gehlot, P., Sidapra, K., Edwards, A. D., & Reis, N. M. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.03.006 · Cited by 227 · see citing works
Acid Neutralizing Capacity of Human Saliva
Helm, J. F., Dodds, W. J., Hogan, W. J., Soergel, K. H., Egide, M. S., & Wood, C. M. (1982) · Gastroenterology · doi:10.1016/s0016-5085(82)80286-2 · Cited by 215 · see citing works
Roda, A., Guardigli, M., Calabria, D., Calabretta, M. M., Cevenini, L., & Michelini, E. (2014) · The Analyst · doi:10.1039/c4an01612b · Cited by 206 · see citing works
Smartphone technology can be transformative to the deployment of lab-on-chip diagnostics
Erickson, D., O’Dell, D., Jiang, L., Oncescu, V., Gümüş, A., Lee, S., Mancuso, M., & Mehta, S. (2014) · Lab on a Chip · doi:10.1039/c4lc00142g · Cited by 183 · see citing works
A paper strip based non-invasive glucose biosensor for salivary analysis
Soni, A., & Jha, S. K. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.09.042 · Cited by 173 · see citing works
Self-citationSelf-Monitoring of Blood Glucose: The Basics
Benjamin, E. M. (2002) · Clinical Diabetes · doi:10.2337/diaclin.20.1.45 · Cited by 162 · see citing works
Noninvasive in vivo glucose sensing on human subjects using mid-infrared light
Liakat, S., Bors, K. A., Xu, L., Woods, C. M., Doyle, J., & Gmachl, C. F. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.002397 · Cited by 146 · see citing works
Salivary composition in diabetic patients
Ben‐Aryeh, H., Cohen, M., KANTER, Y., Szargel, R., & Laufer, D. (1988) · Journal of Diabetes and its Complications · doi:10.1016/0891-6632(88)90011-6 · Cited by 127 · see citing works
Calabria, D., Caliceti, C., Zangheri, M., Mirasoli, M., Simoni, P., & Roda, A. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.02.053 · Cited by 118 · see citing works
Tran, J. T., Tran, R., & White, J. R. (2012) · Clinical Diabetes · doi:10.2337/diaclin.30.4.173 · Cited by 116 · see citing works
Smartphone-Based Fluorescent Diagnostic System for Highly Pathogenic H5N1 Viruses
Yeo, S., Choi, K., Cuc, B. T., Hồng, N. N., Duong, B. T., Ngoc, N. M., Le, M. Q., Hằng, N. L. K., Thach, N. C., Mallik, S. K., et al. (2015) · Theranostics · doi:10.7150/thno.14023 · Cited by 105 · see citing works
Paper-based glucose biosensing system utilizing a smartphone as a signal reader
Chun, H. J., Park, Y. M., Han, Y. D., Jang, Y. H., & Yoon, H. C. (2014) · BioChip Journal · doi:10.1007/s13206-014-8308-7 · Cited by 104 · see citing works
Amer, S., Yousuf, M., Siddqiui, P. Q., & Alam, J. M. (2001) · PubMed · Cited by 102 · see citing works
Non-invasive biosensors in clinical analysis
Guilbault, G. G., Palleschi, G., & Lubrano, G. J. (1995) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(95)96856-t · Cited by 102 · see citing works
Smartphone based bacterial detection using biofunctionalized fluorescent nanoparticles
Rajendran, V. K., Bakthavathsalam, P., & Ali, B. M. J. (2014) · Microchimica Acta · doi:10.1007/s00604-014-1242-5 · Cited by 102 · see citing works
Choi, S., Kim, S., Yang, J.-S., Lee, J., Joo, C., & Jung, H. (2014) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2014.08.001 · Cited by 93 · see citing works
Correlation of Salivary Glucose Level with Blood Glucose Level in Diabetes Mellitus
Panchbhai, A. S. (2012) · Journal of Oral and Maxillofacial Research · doi:10.5037/jomr.2012.3303 · Cited by 90 · see citing works
Salivary glucose levels and oral candidal carriage in type II diabetics
Sashikumar, R., & Ranganathan, K. (2010) · Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology · doi:10.1016/j.tripleo.2009.12.042 · Cited by 90 · see citing works
Noninvasive Method for Glucose Level Estimation by Saliva
Agrawal, R. P. (2013) · Journal of Diabetes & Metabolism · doi:10.4172/2155-6156.1000266 · Cited by 85 · see citing works
The Buffer Capacity of Saliva as a Measure of Dental Caries Activity
Dreizen, S., MANN, A. W., Cline, J. K., & Spies, T. D. (1946) · Journal of Dental Research · doi:10.1177/00220345460250040401 · Cited by 76 · see citing works
Glucose Concentrations in Parotid Fluid and Venous Blood of Patients Attending a Diabetic Clinic 1
Forbat, L. N., Collins, R., Maskell, G. K., & Sönksen, P. H. (1981) · Journal of the Royal Society of Medicine · doi:10.1177/014107688107401004 · Cited by 66 · see citing works
Power-free chip enzyme immunoassay for detection of prostate specific antigen (PSA) in serum
Ahmed, H., & Azzazy, H. M. E.-S. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.05.058 · Cited by 61 · see citing works
Glucose in the saliva of the non-diabetic and the diabetic patient
Campbell, M. J. A. (1965) · Archives of Oral Biology · doi:10.1016/0003-9969(65)90020-8 · Cited by 58 · see citing works
An improved dinitrosalicylic acid method for determining blood and cerebrospinal fluid sugar levels
Mohun, A. F., & Cook, I. J. Y. (1962) · Journal of Clinical Pathology · doi:10.1136/jcp.15.2.169 · Cited by 23 · see citing works
Flagged first, then by citations
1 of the 33 references couldn’t be matched to a known paper.
Research works printed but not linked: 1
- Abikshyeet, 2012, Glucose estimation in the salivary secretion of diabetes mellitus patients, Diabetes, metabolic syndrome and obesity, targets Ther., 5, 149
Cited by
Sorted by citations
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373 · see citing works
Point-of-care testing based on smartphone: The current state-of-the-art (2017–2018)
Liu, J., Geng, Z., Fan, Z., Liu, J., & Chen, H. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.01.068 · Cited by 334 · see citing works
Recent Developments in Biomarkers for Diagnosis and Screening of Type 2 Diabetes Mellitus
Ortiz‐Martínez, M., González‐González, M., Martagón, A. J., Hlavinka, V., Willson, R. C., & Rito‐Palomares, M. (2022) · Current Diabetes Reports · doi:10.1007/s11892-022-01453-4 · Cited by 238 · see citing works
Recent trends in smartphone-based detection for biomedical applications: a review
Banik, S., Melanthota, S. K., Arbaaz, Vaz, J. M., Kadambalithaya, V. M., Hussain, I., Dutta, S., & Mazumder, N. (2021) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03184-z · Cited by 176 · see citing works
Smartphone based optical biosensor for the detection of urea in saliva
Soni, A., Surana, R. K., & Jha, S. K. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.04.108 · Cited by 170 · see citing works
Self-citationCao, L., Han, G., Xiao, H., Chen, Z., & Cheng, F. J. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.10.049 · Cited by 161 · see citing works
Hu, S., Jiang, Y., Wu, Y., Guo, X., Ying, Y., Wen, Y., & Yang, H. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c12988 · Cited by 146 · see citing works
Non-invasive wearable chemical sensors in real-life applications
Promphet, N., Ummartyotin, S., Ngeontae, W., Puthongkham, P., & Rodthongkum, N. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2021.338643 · Cited by 141 · see citing works
Non-enzymatic and non-invasive glucose detection using Au nanoparticle decorated CuO nanorods
Chakraborty, P., Dhar, S., Debnath, K., Majumder, T., & Mondal, S. P. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.12.086 · Cited by 134 · see citing works
Smart biosensors and intelligent devices for salivary biomarker detection
Zheng, X., Zhang, F., Wang, K., Zhang, W., Li, Y., Sun, Y. L., Sun, X., Li, C., Dong, B., Wang, L., et al. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116281 · Cited by 126 · see citing works
Ilea, A., Andrei, V., Feurdean, C. N., Băbțan, A.-M., Petrescu, N. B., Câmpian, R. S., Boşca, A. B., Ciui, B., Tertiş, M., Săndulescu, R., et al. (2019) · Biosensors · doi:10.3390/bios9010027 · Cited by 113 · see citing works
Kap, Ö., Kılıç, V., Hardy, J. G., & Horzum, N. (2021) · The Analyst · doi:10.1039/d0an02031a · Cited by 108 · see citing works
Upadhyay, S., Kumar, A., Srivastava, M., Srivastava, A., Dwivedi, A., Singh, R. K., & Srivastava, S. (2024) · Talanta · doi:10.1016/j.talanta.2024.126080 · Cited by 106 · see citing works
Reddy, V. S., Agarwal, B., Ye, Z., Zhang, C., Roy, K., Chinnappan, A., Narayan, R. J., Ramakrishna, S., & Ghosh, R. (2022) · Nanomaterials · doi:10.3390/nano12071082 · Cited by 97 · see citing works
Electrochemical vs. Optical Biosensors for Point-of-Care Applications: A Critical Review
Pour, S. R. S., Calabria, D., Emamiamin, A., Lazzarini, E., Pace, A., Guardigli, M., Zangheri, M., & Mirasoli, M. (2023) · Chemosensors · doi:10.3390/chemosensors11100546 · Cited by 93 · see citing works
Lee, T., Kim, I., Cheong, D. Y., Roh, S., Jung, H. G., Lee, S. W., Kim, H. S., Yoon, D. S., Hong, Y., & Lee, G. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2021.338387 · Cited by 74 · see citing works
Fu, Q., Zhang, C., Xie, J., Li, Z., Qu, L., Cai, X., Ouyang, H. X., Song, Y., Du, D., Lin, Y., et al. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.09.059 · Cited by 64 · see citing works
Luo, Y., Wang, Q., Li, J., Xu, F., Sun, L., Bu, Y., Zou, Y., Kraatz, H., & Rosei, F. (2020) · Inorganic Chemistry Frontiers · doi:10.1039/d0qi00104j · Cited by 63 · see citing works
Non-Invasive Electrochemical Biosensors Operating in Human Physiological Fluids
Falk, M., Psotta, C., Cirovic, S., & Shleev, S. (2020) · Sensors · doi:10.3390/s20216352 · Cited by 62 · see citing works
Jędrzak, A., Kuznowicz, M., Rębiś, T., & Jesionowski, T. (2022) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2022.108071 · Cited by 59 · see citing works
Yuan, Y., Wang, Y., Wang, H., & Hou, S. (2019) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2019.113495 · Cited by 59 · see citing works
Noninvasive glucose detection in exhaled breath condensate
Tankasala, D., & Linnes, J. C. (2019) · Translational research · doi:10.1016/j.trsl.2019.05.006 · Cited by 54 · see citing works
Abdelbasset, W. K., Savina, S. V., Mavaluru, D., SHICHIYAKH, R. A., Bokov, D. O., & Mustafa, Y. F. (2022) · Talanta · doi:10.1016/j.talanta.2022.123769 · Cited by 54 · see citing works
Kalasin, S., Sangnuang, P., Khownarumit, P., Tang, I. M., & Surareungchai, W. (2020) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.0c00864 · Cited by 53 · see citing works
Hasan, M. K., Aziz, M. H., Zarif, M. I. I., Hasan, M., Hashem, M. M. A., Guha, S., Love, R. R., & Ahamed, S. I. (2020) · JMIR mhealth and uhealth · doi:10.2196/16806 · Cited by 52 · see citing works
Moving toward smart biomedical sensing
Naghdi, T., Ardalan, S., Adib, Z. A., Sharifi, A. R., & Golmohammadi, H. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.115009 · Cited by 52 · see citing works
Biosensing Technologies for Medical Applications, Manufacturing, and Regenerative Medicine
Shafiee, A., Ghadiri, E., Kassis, J. N., Zarandi, N. P., & Atala, A. (2018) · Current Stem Cell Reports · doi:10.1007/s40778-018-0123-y · Cited by 51 · see citing works
Non-invasive, ultrasensitive detection of glucose in saliva using metal oxide transistors
Sharma, A., AlGhamdi, W. S., Faber, H. A., Lin, Y., Liu, C., Hsu, E.-K., Lin, W., Naphade, D. R., Mandal, S. K., Heeney, M., et al. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115448 · Cited by 50 · see citing works
Singh, A. K., & Jha, S. K. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2920296 · Cited by 50 · see citing works
Self-citationKhachornsakkul, K., Rybicki, F. J., & Sonkusale, S. (2023) · Talanta · doi:10.1016/j.talanta.2023.124538 · Cited by 46 · see citing works
Recent Advances in Smart Phone-Based Biosensors for Various Applications
Xing, E., Chen, H., Xin, X., Cui, H., Dou, Y., & Song, S. (2025) · Chemosensors · doi:10.3390/chemosensors13070221 · Cited by 47 · see citing works
Color changing sensors: A multimodal system for integrated screening
Shende, P. K., Prabhakar, B. R., & Patil, A. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.115687 · Cited by 45 · see citing works
Golap, M. A.-U., Raju, S. M. T. U., Haque, M. R., & Hashem, M. M. A. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102478 · Cited by 43 · see citing works
Rajasulochana, P., Ganesan, Y., Kumar, P. S., Mahalaxmi, S., Tasneem, S., Ponnuchamy, M., & Kapoor, A. (2022) · Environmental Research · doi:10.1016/j.envres.2022.112745 · Cited by 43 · see citing works
Microneedle-Based Glucose Sensor Platform: From Vitro to Wearable Point-of-Care Testing Systems
Ju, J., Li, L., Regmi, S., Zhang, X., & Tang, S. (2022) · Biosensors · doi:10.3390/bios12080606 · Cited by 42 · see citing works
Breath-based biosensors and system development for noninvasive detection of diabetes: A review
Jadhav, M. R., Wankhede, P. R., Srivastava, S., Bhargaw, H. N., & Singh, S. (2023) · Diabetes & Metabolic Syndrome Clinical Research & Reviews · doi:10.1016/j.dsx.2023.102931 · Cited by 42 · see citing works
Saeed, A. A., Abbas, M. N., Singh, B., ABOUZEID, R. E., & Kamel, S. M. (2019) · Analytical Methods · doi:10.1039/c9ay02176k · Cited by 42 · see citing works
Fabrication of porous silicon based label-free optical biosensor for heat shock protein 70 detection
Maniya, N. H., & Srivastava, D. N. (2020) · Materials Science in Semiconductor Processing · doi:10.1016/j.mssp.2020.105126 · Cited by 42 · see citing works
Promphet, N., Thanawattano, C., Buekban, C., Laochai, T., Rattanawaleedirojn, P., Siralertmukul, K., Potiyaraj, P., Hinestroza, J. P., & Rodthongkum, N. (2022) · Advanced Materials Technologies · doi:10.1002/admt.202101684 · Cited by 41 · see citing works
Smartphone-Based Electrochemical Systems for Glucose Monitoring in Biofluids: A Review
Xu, J., Yan, Z., & Liu, Q. (2022) · Sensors · doi:10.3390/s22155670 · Cited by 40 · see citing works
Estimation of trace-mercury concentration in water using a smartphone
Hatiboruah, D., Das, T., Chamuah, N., Rabha, D., Talukdar, B., Bora, U., Ahamad, K. U., & Nath, P. (2020) · Measurement · doi:10.1016/j.measurement.2020.107507 · Cited by 40 · see citing works
Dou, Q., Zhang, Z., Wang, Y., Wang, S., Hu, D., Zhao, Z., Liu, H., & Dai, Q. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c08229 · Cited by 39 · see citing works
Proteomic advances in salivary diagnostics.
Pappa, E., Vougas, K., Zoidakis, J., & Vastardis, H. (2020) · Biochimica et Biophysica Acta - Proteins and Proteomics · doi:10.1016/j.bbapap.2020.140494 · Cited by 35 · see citing works
Bibliometric Analysis and Methodological Review of Mobile Health Services and Applications in India
Pai, R. R., & Alathur, S. (2021) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2020.104330 · Cited by 35 · see citing works
Survey of Saliva Components and Virus Sensors for Prevention of COVID-19 and Infectious Diseases
Dave, P., Rojas‐Cessa, R., Dong, Z., & Umpaichitra, V. (2020) · Biosensors · doi:10.3390/bios11010014 · Cited by 35 · see citing works
Fan, B., Wu, Y., Guo, H., Yu, F., Liu, L.-E., Yu, S., Wang, J., & Wang, Y. (2024) · Analytica Chimica Acta · doi:10.1016/j.aca.2024.342852 · Cited by 34 · see citing works
Smartphone-based image analysis coupled to paper-based colorimetric devices
Kim, D., Kim, S., Ha, H.-T., & Kim, S. (2020) · Current Applied Physics · doi:10.1016/j.cap.2020.06.021 · Cited by 29 · see citing works
Vidal, E., Lorenzetti, A. S., García, C. D., & Domini, C. E. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2021.338249 · Cited by 28 · see citing works
Gholamalizadeh, N., Mazinani, S., Abdouss, M., Bazargan, A. M., & Fatemi, F. (2022) · Progress in Organic Coatings · doi:10.1016/j.porgcoat.2022.107083 · Cited by 28 · see citing works
Geldsetzer, P., Flores, S., Wang, G., Flores, B. E. I., Rogers, A. B., Bunker, A., Chang, A. Y., & Tisdale, R. L. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00644-3 · Cited by 29 · see citing works
Dou, Q., Wang, S., Zhang, Z., Wang, Y., Zhao, Z., Guo, H., Liu, H., & Dai, Q. (2020) · Nanoscale · doi:10.1039/d0nr03193c · Cited by 26 · see citing works
Development of an amperometric biosensor on a toothbrush for glucose
Liu, Y., Yue, W., & Cui, Y. (2022) · Sensors and Actuators Reports · doi:10.1016/j.snr.2022.100133 · Cited by 26 · see citing works
Ortiz‐Martínez, M., Flores-DelaToba, R., González‐González, M., & Rito‐Palomares, M. (2021) · Biosensors · doi:10.3390/bios11120482 · Cited by 25 · see citing works
A Chemometric-Assisted Colorimetric-Based Inexpensive Paper Biosensor for Glucose Detection
Kishnani, V., Kumari, S., & Gupta, A. (2022) · Biosensors · doi:10.3390/bios12111008 · Cited by 25 · see citing works
Nanosensors for Therapeutic Drug Monitoring: Implications for Transplantation
Shafiee, A., Ghadiri, E., Kassis, J. N., & Atala, A. (2019) · Nanomedicine · doi:10.2217/nnm-2019-0150 · Cited by 25 · see citing works
Tandem Quantification of Multiple Carbohydrates in Saliva Using Surface-Enhanced Raman Spectroscopy
Lin, D., Yang, S.-W., Hsieh, C.-L., Hsu, K.-J., Gong, T., Wu, Q., Qiu, S., Feng, S., & Kong, K. V. (2021) · ACS Sensors · doi:10.1021/acssensors.0c02533 · Cited by 24 · see citing works
Salivary glucose measurement: A holy ground for next generation of non-invasive diabetic monitoring
Ko, A., & Liao, C. (2023) · Hybrid Advances · doi:10.1016/j.hybadv.2023.100052 · Cited by 24 · see citing works
A miniature CuO nanoarray sensor for noninvasive detection of trace salivary glucose
Yang, J., Chen, H., Zhu, C., Huang, Z., Ou, R., Gao, S., & Yang, Z. (2022) · Analytical Biochemistry · doi:10.1016/j.ab.2022.114857 · Cited by 23 · see citing works
Panwar, S., Sarkar, P., Kasim, D. S., Anand, R., Priya, A., Prakash, S., & Jha, S. K. (2024) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2024.100452 · Cited by 22 · see citing works
Self-citationWide-field multi-modal microscopic imaging using smartphone
Rabha, D., Biswas, S., Chamuah, N., Mandal, M., & Nath, P. (2020) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106343 · Cited by 22 · see citing works
Lanzalaco, S., Fabregat, G., Muñoz-Galán, H., Cabrera, J., Muñoz-Pascual, X., Llorca, J., & Alemán, C. (2020) · ACS Sustainable Chemistry & Engineering · doi:10.1021/acssuschemeng.0c03545 · Cited by 21 · see citing works
gluCam: Smartphone Based Blood Glucose Monitoring and Diabetic Sensing
Ghosal, S., Kumar, A., Udutalapally, V., & Das, D. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3116191 · Cited by 19 · see citing works
Molecularly imprinted polymer-based biosensor for detection of salivary glucose in diabetes
Vaidya, A., Sahoo, J., & Shende, P. K. (2025) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2025.125219 · Cited by 19 · see citing works
Skonta, A., Bellou, M. G., Matikas, T. E., & Stamatis, H. (2024) · Biosensors · doi:10.3390/bios14060299 · Cited by 18 · see citing works
Optical blood glucose non-invasive detection and its research progress
Peng, Z., & Yang, Z. (2024) · The Analyst · doi:10.1039/d4an01048e · Cited by 18 · see citing works
Integrated paper-based sensing devices for diagnostic applications
Brunauer, A., Ates, H. C., Dincer, C., & Früh, S. M. (2020) · Comprehensive analytical chemistry · doi:10.1016/bs.coac.2020.03.003 · Cited by 18 · see citing works
Modern noninvasive methods for monitoring glucose levels in patients: a review
Dziergowska, K., Łabowska, M. B., Gąsior‐Głogowska, M., Kmiecik, B., & Detyna, J. D. (2019) · Bio-Algorithms and Med-Systems · doi:10.1515/bams-2019-0052 · Cited by 18 · see citing works
Immobilization of glucose oxidase on plasma-treated polyethylene for non-invasive glucose detection
Fabregat, G., Lanzalaco, S., Saïd, J. A., Muñoz-Pascual, X., Llorca, J., & Alemán, C. (2021) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2021.115509 · Cited by 17 · see citing works
Revisiting the Use of Biological Fluids for Noninvasive Glucose Detection
Zhao, M., & Leung, P. S. (2020) · Future Medicinal Chemistry · doi:10.4155/fmc-2020-0019 · Cited by 16 · see citing works
Review of point-of-care platforms for diabetes: (1) sensing
Liu, Y., Luo, X., Yu, Q., Ye, L., Yang, L., & Cui, Y. (2022) · Sensors and Actuators Reports · doi:10.1016/j.snr.2022.100113 · Cited by 16 · see citing works
Clinical Evaluation of a Photonic Crystal Sensor for Glucose Monitoring in Urine
Lan, Y., Xue, M., Qiu, L., & Meng, Z. (2019) · ChemistrySelect · doi:10.1002/slct.201900840 · Cited by 16 · see citing works
A Smart Tongue Depressor-Based Biosensor for Glucose
Luo, X., Shi, W., Liu, Y., Sha, P., Chu, Y., & Cui, Y. (2019) · Sensors · doi:10.3390/s19183864 · Cited by 16 · see citing works
Advances in point-of-care testing based on microfluidic chips towards small molecular biomarkers
Hu, W., Zhao, Y. C., Qi, H., Sun, H., Xie, Y., Wang, Y., & Liang, Q. (2025) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2025.118596 · Cited by 14 · see citing works
NFC-enabled photothermal-based microfluidic paper analytical device for glucose detection
Khachornsakkul, K., Del‐Rio‐Ruiz, R., Asci, C., & Sonkusale, S. (2024) · The Analyst · doi:10.1039/d4an00506f · Cited by 14 · see citing works
Ekawita, R., Nasution, A. A., Yuliza, E., Suardi, N., & Suwarsono, S. (2020) · Jurnal Penelitian Fisika dan Aplikasinya (JPFA) · doi:10.26740/jpfa.v10n2.p103-113 · Cited by 14 · see citing works
Saliva sampling strategies affecting the salivary glucose measurement
Qian, X., Ko, A. S. M., Li, H., & Liao, C. (2023) · Analytical Methods · doi:10.1039/d3ay01005h · Cited by 13 · see citing works
Data Reliability and Quality in Body Area Networks for Diabetes Monitoring
Huzooree, G., Khedo, K. K., & Joonas, N. (2018) · EAI/Springer Innovations in Communication and Computing · doi:10.1007/978-3-030-00865-9_4 · Cited by 13 · see citing works
Microfluidic Technologies Using Oral Factors: Saliva-Based Studies
Masooleh, H. S., Ghavami‐Lahiji, M., Ciancio, A., & Tayebi, L. (2019) · Springer eBooks · doi:10.1007/978-3-030-21583-5_16 · Cited by 13 · see citing works
Çelik, H., Caf, B. B., & Çebi, G. (2025) · Chemical Papers · doi:10.1007/s11696-025-04319-7 · Cited by 12 · see citing works
Electrochemical (bio-)sensors operating in human physiological fluids
Psotta, C. (2023) · doi:10.24834/isbn.9789178773992 · Cited by 12 · see citing works
Chemiluminescence methods for glucose determination: A guiding light for diabetes management
Iranifam, M. (2025) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2025.118316 · Cited by 11 · see citing works
Martins, L., Silva, A. F. D. S., de Moraes, L. M. B., Gonçalves, I. C., de Godoy, B. B. R., & Rocha, F. R. P. (2020) · International Electronic Conference on Foods (Foods) · doi:10.3390/foods_2020-07655 · Cited by 11 · see citing works
A biosensor based on a thermal camera using infrared radiance as the signal probe
Jiao, F., Cao, F., Gao, Y., Shuang, F., & Dong, D. (2022) · Talanta · doi:10.1016/j.talanta.2022.123453 · Cited by 11 · see citing works
A smartphone-based photometric and fluorescence sensing for accurate estimation of zinc ion in water
Hatiboruah, D., Biswas, S., Sarma, D., & Nath, P. (2022) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2022.113586 · Cited by 11 · see citing works
Mashhadizadeh, M. H., & Abdollahi, G. (2023) · ChemistrySelect · doi:10.1002/slct.202204359 · Cited by 11 · see citing works
Mannino, R. G., Sullivan, J., Frediani, J. K., George, P. E., Whitson, J. D., Tumlin, J. A., Lyon, L. A., Tyburski, E. A., & Lam, W. A. (2025) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2424677122 · Cited by 10 · see citing works
Kimura, H., & Asano, R. (2022) · Analytical Biochemistry · doi:10.1016/j.ab.2022.114806 · Cited by 10 · see citing works
A Glucose Monitoring System With Remote Data Access
Baingane, A., & Slaughter, G. E. (2020) · IEEE Transactions on NanoBioscience · doi:10.1109/tnb.2020.3002453 · Cited by 9 · see citing works
Melman, Y., Wells, P. K., Katz, E., & Smutok, O. V. (2022) · Talanta · doi:10.1016/j.talanta.2022.123325 · Cited by 9 · see citing works
Fully inkjet-printed glucose assay fabricated on highly porous pigment coating
Jutila, E., Koivunen, R., Bollström, R., & Gane, P. A. C. (2020) · Microfluidics and Nanofluidics · doi:10.1007/s10404-020-02344-4 · Cited by 8 · see citing works
Development of a palm-sized bioelectronic sensing device for protein detection in milk samples
Mahapatra, S., & Chandra, P. (2023) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2022.123132 · Cited by 8 · see citing works
de Santana, P. C., & Lourenço, F. R. (2020) · Microchemical Journal · doi:10.1016/j.microc.2020.104626 · Cited by 7 · see citing works
Xu, W., Ouyang, M., Luo, H., Xu, D., & Lin, Q. (2022) · New Journal of Chemistry · doi:10.1039/d2nj03107h · Cited by 7 · see citing works
A non-invasive device for glucose monitoring through saliva – a paradigm shift in diabetes care
Panwar, S., Kasim, D. S., Singh, H., Priya, A., Deepak, K. K., Prakash, S., & Jha, S. K. (2025) · Sensors & Diagnostics · doi:10.1039/d5sd00027k · Cited by 6 · see citing works
Self-citationGlucose Monitoring Techniques and Their Calibration
Yadav, D., Singh, S. P., & Dubey, P. K. (2023) · Springer eBooks · doi:10.1007/978-981-19-1550-5_99-1 · Cited by 6 · see citing works
Artigues, M., Oh, S., Gilabert‐Porres, J., Abellà, J., Borrós, S., & Colominas, S. (2018) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2018.11.076 · Cited by 6 · see citing works
Fang, Y., Ning, J., Tang, Z., Hu, T., Zhu, T., Wang, F. R., Wang, C., Shen, X., & Chong, Y. (2025) · Nano Research · doi:10.26599/nr.2025.94907984 · Cited by 5 · see citing works
Sharma, V., Kapil, D., & Singh, B. (2024) · Process Biochemistry · doi:10.1016/j.procbio.2024.11.023 · Cited by 5 · see citing works
A Saliva-Based Noninvasive Point-of-Care Glucometer
Panwar, S., Aasarey, R., Anand, R., Priya, A., Prakash, S., & Jha, S. K. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3536293 · Cited by 5 · see citing works
Self-citationPalladium‐Based Nanozymes: From Synthesis and Activity Modulation to Biomedical Applications
Fang, Y., Liu, Y., Tang, Z., Zhang, Z., Yang, X., Li, X., Zhao, L., & Chong, Y. (2026) · Chemistry - A European Journal · doi:10.1002/chem.202503589 · Cited by 4 · see citing works
- Authors
- Soni, A., & Jha, S. K.
- Affiliations
- All India Institute of Medical Sciences (IN)
- Corresponding author
- Jha, Sandeep Kumar
- ORCID
- Jha, Sandeep Kumar
- Venue
- Analytica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2017-12
- Volume
- 996
- Pages
- 54-63
- ISSN
- 0003-2670 (ISSN-L)
- OpenAlex
- W2766873441
- Cited by
- 143
- References
- 33
- Citations by year
- 2026: 7 · 2025: 22 · 2024: 9 · 2023: 13 · 2022: 30 · 2021: 11 · 2020: 25 · 2019: 18 · 2018: 8
- FWCI
- 6.29
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytica Chimica Acta (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Indian Institute of Technology Delhi
- Indian Council of Medical Research
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Keywords
- salivary glucose, smartphone sensing, glucose oxidase, pH-responsive dyes, colorimetric sensing, diabetes diagnosis, disposable test strip, low-cost diagnostics
- MeSH terms
- Smartphone, Adult, Aged, Aged, 80 and over, Diabetes Mellitus, Enzymes, Immobilized, Female, Glucose, Glucose Oxidase, Humans, Male, Middle Aged, Saliva, Biosensing Techniques, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review