The DOI matches its Crossref record; 161 of the 161 references it cites were found in a registry or an index.
PET-guided delineation of radiation therapy treatment volumes: a survey of image segmentation techniques
Open accessAbstract
Historically, anatomical CT and MR images were used to delineate the gross tumour volumes (GTVs) for radiotherapy treatment planning. The capabilities offered by modern radiation therapy units and the widespread availability of combined PET/CT scanners stimulated the development of biological PET imaging-guided radiation therapy treatment planning with the aim to produce highly conformal radiation dose distribution to the tumour. One of the most difficult issues facing PET-based treatment planning is the accurate delineation of target regions from typical blurred and noisy functional images. The major problems encountered are image segmentation and imperfect system response function. Image segmentation is defined as the process of classifying the voxels of an image into a set of distinct classes. The difficulty in PET image segmentation is compounded by the low spatial resolution and high noise characteristics of PET images. Despite the difficulties and known limitations, several image segmentation approaches have been proposed and used in the clinical setting including thresholding, edge detection, region growing, clustering, stochastic models, deformable models, classifiers and several other approaches. A detailed description of the various approaches proposed in the literature is reviewed. Moreover, we also briefly discuss some important considerations and limitations of the widely used techniques to guide practitioners in the field of radiation oncology. The strategies followed for validation and comparative assessment of various PET segmentation approaches are described. Future opportunities and the current challenges facing the adoption of PET-guided delineation of target volumes and its role in basic and clinical research are also addressed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
A Threshold Selection Method from Gray-Level Histograms
Otsu, N. (1979) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1979.4310076 · Cited by 43,398
A Computational Approach to Edge Detection
Canny, J. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767851 · Cited by 30,004
(2012) · Encyclopedia of the Sciences of Learning · doi:10.1007/978-1-4419-1428-6_5195 · Cited by 19,370
Kass, M., Witkin, A., & Terzopoulos, D. (1988) · International Journal of Computer Vision · doi:10.1007/bf00133570 · Cited by 17,070
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Fronts propagating with curvature-dependent speed: Algorithms based on Hamilton-Jacobi formulations
Osher, S., & Sethian, J. A. (1988) · Journal of Computational Physics · doi:10.1016/0021-9991(88)90002-2 · Cited by 14,062
Jain, A. K., Murty, M. N., & Flynn, P. J. (1999) · ACM Computing Surveys · doi:10.1145/331499.331504 · Cited by 13,199
Scale-space and edge detection using anisotropic diffusion
Perona, P., & Malik, J. (1990) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.56205 · Cited by 12,119
Chan, T. F., & Vese, L. A. (2001) · IEEE Transactions on Image Processing · doi:10.1109/83.902291 · Cited by 10,304
Ashburner, J., & Friston, K. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.02.018 · Cited by 7,507
Statistical pattern recognition: a review
Jain, A. K., Duin, P. W., & Mao, J. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.824819 · Cited by 6,767
Marr, D., & Hildreth, E. (1980) · Proceedings of the Royal Society of London. Series B. Biological Sciences · doi:10.1098/rspb.1980.0020 · Cited by 6,510
Snakes, shapes, and gradient vector flow
Xu, C., & Prince, J. L. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.661186 · Cited by 4,001
Abe, S. (2001) · Springer eBooks · doi:10.1007/978-1-4471-0285-4 · Cited by 3,721
A review on image segmentation techniques
Pal, N. R., & Pal, S. K. (1993) · Pattern Recognition · doi:10.1016/0031-3203(93)90135-j · Cited by 3,708
Sethian, J. A. (1999) · Cited by 3,622
Piegl, L., & Tiller, W. (1997) · Monographs in Visual Communication · doi:10.1007/978-3-642-59223-2 · Cited by 2,871
Alignment by Maximization of Mutual Information
Viola, P., & Wells III, W. M. (1997) · International Journal of Computer Vision · doi:10.1023/a:1007958904918 · Cited by 2,610
Pattern Classification (2nd ed.)
Duda, R. O., Hart, P. E., & Stork, D. G. (1999) · Cited by 2,520
Duda, R. O., Hart, P. E., & Stork, D. G. (2001) · Cited by 2,463
A definition of a nonprobabilistic entropy in the setting of fuzzy sets theory
De Luca, A., & Termini, S. (1972) · Information and Control · doi:10.1016/s0019-9958(72)90199-4 · Cited by 2,261
Kittler, J., & Illingworth, J. (1986) · Pattern Recognition · doi:10.1016/0031-3203(86)90030-0 · Cited by 2,180
Prescribing, recording, and reporting photon beam therapy
Icru (1993) · Medical Entomology and Zoology · Cited by 1,996
Principles and Practice of Radiation Oncology
Perez, C., & Brady, L. (1999) · Journal of Pediatric Hematology/Oncology · doi:10.1097/00043426-199911000-00025 · Cited by 1,871
Statistical validation of image segmentation quality based on a spatial overlap index1
Zou, K. H., Warfield, S. K., Bharatha, A., Tempany, C. M. C., Kaus, M. R., Haker, S. J., Wells, W. M., Jolesz, F. A., & Kikinis, R. (2004) · Academic Radiology · doi:10.1016/s1076-6332(03)00671-8 · Cited by 1,849
Partial-Volume Effect in PET Tumor Imaging
Soret, M., Bacharach, S. L., & Buvat, I. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.035774 · Cited by 1,549
A survey on evaluation methods for image segmentation
Zhang, Y. J. (1996) · Pattern Recognition · doi:10.1016/0031-3203(95)00169-7 · Cited by 1,059
Automated model-based tissue classification of MR images of the brain
Van Leemput, K., Maes, F., Vandermeulen, D., & Suetens, P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811270 · Cited by 1,024
Towards multidimensional radiotherapy (MD-CRT): biological imaging and biological conformality
Ling, C. C., Humm, J., Larson, S., Amols, H., Fuks, Z., Leibel, S., & Koutcher, J. A. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00467-3 · Cited by 926
Standards for PET Image Acquisition and Quantitative Data Analysis
Boellaard, R. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.057182 · Cited by 902
SUV: standard uptake or silly useless value?
Keyes, J. W. (1995) · PubMed · Cited by 803
Daisne, J.-F., Duprez, T., Weynand, B., Lonneux, M., Hamoir, M., Reychler, H., & Grégoire, V. (2004) · Radiology · doi:10.1148/radiol.2331030660 · Cited by 677
Radiation oncology: a century of achievements
Bernier, J., Hall, E. J., & Giaccia, A. (2004) · Nature Reviews Cancer · doi:10.1038/nrc1451 · Cited by 628
Alignment by Maximization of Mutual Information
Viola, P. A. (1995) · doi:10.21236/ada299525 · Cited by 614
(2005) · PubMed · Cited by 612
Hall, L. O., Bensaid, A. M., Clarke, L. P., Velthuizen, R. P., Silbiger, M. S., & Bezdek, J. C. (1992) · IEEE Transactions on Neural Networks · doi:10.1109/72.159057 · Cited by 580
Impact of FDG-PET on radiation therapy volume delineation in non–small-cell lung cancer
Bradley, J., Thorstad, W. L., Mutic, S., Miller, T. R., Dehdashti, F., Siegel, B. A., Bosch, W., & Bertrand, R. J. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2003.10.044 · Cited by 556
Ciernik, I. F., Dizendorf, E., Baumert, B. G., Reiner, B., Burger, C., Davis, J. B., Lütolf, U. M., Steinert, H. C., & Von Schulthess, G. K. (2003) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(03)00346-8 · Cited by 543
Segmentation of lung lesion volume by adaptive positron emission tomography image thresholding
Erdi, Y. E., Mawlawi, O., Larson, S. M., Imbriaco, M., Yeung, H., Finn, R., & Humm, J. L. (1997) · Cancer · doi:10.1002/(sici)1097-0142(19971215)80:12+<2505::aid-cncr24>3.0.co;2-f · Cited by 480
Pham, D. L., & Prince, J. L. (1999) · Pattern Recognition Letters · doi:10.1016/s0167-8655(98)00121-4 · Cited by 472
Huang, (. S.-C. (2000) · Nuclear Medicine and Biology · doi:10.1016/s0969-8051(00)00155-4 · Cited by 458
Medical image registration using mutual information
Maes, F., Vandermeulen, D., & Suetens, P. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.817864 · Cited by 432
Detection of Intensity Changes with Subpixel Accuracy Using Laplacian-Gaussian Masks
Huertas, A., & Medioni, G. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767838 · Cited by 429
A gradient-based method for segmenting FDG-PET images: methodology and validation
Geets, X., Lee, J. A., Bol, A., Lonneux, M., & Grégoire, V. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0363-4 · Cited by 419
Interaction in the segmentation of medical images: A survey
Olabarriaga, S. D., & Smeulders, A. W. M. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00041-4 · Cited by 381
Daisne, J.-F., Sibomana, M., Bol, A., Doumont, T., Lonneux, M., & Grégoire, V. (2003) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(03)00270-6 · Cited by 380
Hillner, B. E., Siegel, B. A., Liu, D., Shields, A. F., Gareen, I. F., Hanna, L., Stine, S. H., & Coleman, R. E. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2007.14.5631 · Cited by 374
Improvements in cancer staging with PET/CT: literature-based evidence as of September 2006.
Czernin, J. G., Allen-Auerbach, M., & Schelbert, H. R. (2007) · PubMed · Cited by 355
Fiorino, C., Reni, M., Bolognesi, A., Cattaneo, G. M., & Calandrino, R. (1998) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(98)00021-8 · Cited by 354
Wyckoff, H. O. (1974) · American Journal of Roentgenology · doi:10.2214/ajr.120.3.708 · Cited by 354
Nestle, U., Walter, K., Schmidt, S., Licht, N. P., Nieder, C., Motaref, B., Hellwig, D., Niewald, M., Ukena, D., Kirsch, C. M., et al. (1999) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(99)00061-9 · Cited by 353
Principles and Practice of Radiation Oncology
Gunn, W. G. (2004) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.291.19.2383-a · Cited by 348
Erdi, Y. E., Rosenzweig, K., Erdi, A. K., Macapinlac, H. A., Hu, Y.-C., Braban, L. E., Humm, J. L., Squire, O. D., Chui, C.-S., Larson, S. M., et al. (2002) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(01)00470-4 · Cited by 338
Caldwell, C. B., Mah, K., Ung, Y. C., Danjoux, C. E., Balogh, J. M., Ganguli, S. N., & Ehrlich, L. E. (2001) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(01)01722-9 · Cited by 320
Imaging of Cell Proliferation: Status and Prospects
Bading, J. R., & Shields, A. F. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.046391 · Cited by 320
Respiratory Motion in Positron Emission Tomography/Computed Tomography: A Review
Nehmeh, S. A., & Erdi, Y. E. (2008) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2008.01.002 · Cited by 317
Steenbakkers, R. J. H. M., Duppen, J. C., Fitton, I., Deurloo, K. E. I., Zijp, L. J., Comans, E. F. I., Uitterhoeve, A. L. J., Rodrigus, P. T. R., Kramer, G. W. P., Bussink, J., et al. (2006) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2005.06.034 · Cited by 309
Mah, K., Caldwell, C. B., Ung, Y. C., Danjoux, C. E., Balogh, J. M., Ganguli, S. N., Ehrlich, L. E., & Tirona, R. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(01)01824-7 · Cited by 307
van Baardwijk, A., Bosmans, G., Boersma, L., Buijsen, J., Wanders, S., Hochstenbag, M., van Suylen, R.-J., Dekker, A., Dehing-Oberije, C., Houben, R., et al. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.12.067 · Cited by 295
Unified measurement of observer performance in detecting and localizing target objects on images
Swensson, R. G. (1996) · Medical Physics · doi:10.1118/1.597758 · Cited by 286
Vanuytsel, L., Vansteenkiste, J., Stroobants, S. G., Leyn, P. R. D., Wever, W. D., Verbeken, E. K., Gatti, G. G., Huyskens, D. P., & Kutcher, G. J. (2000) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(00)00138-9 · Cited by 286
Multimodality imaging of structure and function
Townsend, D. W. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/4/r01 · Cited by 286
Miller, T. R., & Grigsby, P. W. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02705-0 · Cited by 284
Voxel similarity measures for 3-D serial MR brain image registration
Holden, M., Hill, D. L. G., Denton, E. R. E., Jarosz, J. M., Cox, T. C. S., Rohlfing, T., Goodey, J., & Hawkes, D. J. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.836369 · Cited by 277
Quantitative Analysis in Nuclear Medicine Imaging
(2006) · Springer eBooks · doi:10.1007/b107410 · Cited by 266
Image Segmentation Using Deformable Models
Xu, C., Pham, D., & Prince, J. (2010) · Handbook of Medical Imaging, Volume 2. Medical Image Processing and Analysis · doi:10.1117/3.831079.ch3 · Cited by 264
Paulino, A. C., Koshy, M., Howell, R., Schuster, D., & Davis, L. W. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.08.037 · Cited by 264
Defining a radiotherapy target with positron emission tomography
Black, Q. C., Grills, I. S., Kestin, L. L., Wong, C.-Y. O., Wong, J. W., Martinez, A. A., & Yan, D. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.06.254 · Cited by 263
Biehl, K. J., Kong, F., Dehdashti, F., Jin, J., Mutic, S., Naqa, I. E., Siegel, B. A., & Bradley, J. D. (2006) · PubMed · Cited by 260
Lamare, F., Carbayo, M. J. L., Cresson, T., Kontaxakis, G., Santos, A., Rest, C. C. L., Reader, A. J., & Visvikis, D. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/17/006 · Cited by 259
Pichler, B. J., Wehrl, H. F., Kolb, A., & Judenhofer, M. S. (2008) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2008.02.001 · Cited by 258
Development and application of the new dynamic Nurbs-based Cardiac-Torso (NCAT) phantom.
Segars, W. P., Tsui, B. M. W., Lalush, D. S., Frey, E. C., King, M., & Manocha, D. (2001) · ScholarWorks@UMassAmherst (University of Massachusetts Amherst) · Cited by 254
Voxel Similarity Measures for 3D Serial MR Brain Image Registration
Holden, M., Hill, D. L. G., Denton, E. R. E., Jarosz, J. M., Cox, T. C. S., & Hawkes, D. J. (1999) · Lecture Notes in Computer Science · doi:10.1007/3-540-48714-x_48 · Cited by 246
Variability of gross tumor volume delineation in head-and-neck cancer using CT and PET/CT fusion
Riegel, A. C., Berson, A. M., Destian, S., Ng, T., Tena, L. B., Mitnick, R. J., & Wong, P. S. (2006) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.01.014 · Cited by 242
Defining a radiotherapy target with positron emission tomography
Black, Q. C., Yan, D., Kestin, L. L., Wong, C. O., Wong, J. W., & Martinez, A. A. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)03114-0 · Cited by 240
Grosu, A.-L., Souvatzoglou, M., Röper, B., Dobritz, M., Wiedenmann, N., Jacob, V., Wester, H.-J., Reischl, G., Machulla, H.-J., Schwaiger, M., et al. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2007.05.079 · Cited by 229
Respiratory gating for 3-dimensional PET of the thorax: feasibility and initial results.
Boucher, L., Rodrigue, S., Lecomte, R., & Bénard, F. (2004) · PubMed · Cited by 226
Giraud, P., Elles, S., Helfre, S., De Rycke, Y., Servois, V., Carette, M.-F., Alzieu, C., Bondiau, P.-Y., Dubray, B., Touboul, E., et al. (2002) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(01)00444-3 · Cited by 223
Kalff, V., Hicks, R. J., P. MacManus, M., Binns, D. S., McKenzie, A. F., Ware, R. E., Hogg, A., & Ball, D. L. (2001) · Journal of Clinical Oncology · doi:10.1200/jco.2001.19.1.111 · Cited by 220
Zaidi, H., & Xu, X. G. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151934 · Cited by 219
Self-citationNestle, U., Kremp, S., & Grosu, A.-L. (2006) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2006.09.011 · Cited by 214
Schinagl, D. A. X., Vogel, W. V., Hoffmann, A. L., van Dalen, J. A., Oyen, W. J., & Kaanders, J. H. A. M. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2007.07.2333 · Cited by 211
Model‐based image reconstruction for four‐dimensional PET
Li, T., Thorndyke, B., Schreibmann, E., Yang, Y., & Xing, L. (2006) · Medical Physics · doi:10.1118/1.2192581 · Cited by 210
List Mode–Driven Cardiac and Respiratory Gating in PET
Büther, F., Dawood, M., Stegger, L., Wübbeling, F., Schäfers, M., Schober, O., & Schäfers, K. P. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.059204 · Cited by 205
Partial Volume Correction Strategies in PET
Rousset, O., Rahmim, A., Alavi, A., & Zaidi, H. (2007) · PET Clinics · doi:10.1016/j.cpet.2007.10.005 · Cited by 190
Self-citationA novel fuzzy C‐means algorithm for unsupervised heterogeneous tumor quantification in PET
Belhassen, S., & Zaidi, H. (2010) · Medical Physics · doi:10.1118/1.3301610 · Cited by 190
Self-citationFuzzy connectedness and image segmentation
Udupa, J. K., & Saha, P. K. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.817883 · Cited by 188
Kiffer, J. D., Berlangieri, S. U., Scott, A. M., Quong, G., Feigen, M., Schumer, W., Clarke, C. P., Knight, S. R., & Daniel, F. J. (1998) · Lung Cancer · doi:10.1016/s0169-5002(97)00086-x · Cited by 187
MCAT to XCAT: The Evolution of 4-D Computerized Phantoms for Imaging Research
Segars, W. P., & Tsui, B. M. W. (2009) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2022417 · Cited by 181
Hatt, M., Cheze le Rest, C., Descourt, P., Dekker, A., De Ruysscher, D., Oellers, M., Lambin, P., Pradier, O., & Visvikis, D. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.08.018 · Cited by 179
Jager, P. L., Chirakal, R., Marriott, C. J., Brouwers, A. H., Koopmans, K. P., & Gulenchyn, K. Y. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.045708 · Cited by 179
Munley, M. T., Marks, L. B., Scarfone, C., Sibley, G. S., Patz, E. F., Turkington, T. G., Jaszczak, R. J., Gilland, D. R., Anscher, M. S., & Coleman, R. E. (1999) · Lung Cancer · doi:10.1016/s0169-5002(99)00005-7 · Cited by 171
Caldwell, C. B., Mah, K., Skinner, M., & Danjoux, C. E. (2003) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)04609-6 · Cited by 171
Scarfone, C., Lavely, W. C., Cmelak, A. J., Delbeke, D., Martin, W. H., Billheimer, D. D., & Hallahan, D. E. (2004) · PubMed · Cited by 170
Greco, C., Rosenzweig, K., Cascini, G. L., & Tamburrini, O. (2007) · Lung Cancer · doi:10.1016/j.lungcan.2007.03.020 · Cited by 167
MRI: Stability of three supervised segmentation techniques
Clarke, L. P., Velthuizen, R. P., Phuphanich, S., Schellenberg, J. D., Arrington, J. A., & Silbiger, M. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90417-c · Cited by 166
Strategies for Motion Tracking and Correction in PET
Rahmim, A., ROUSSET, O. G., & Zaidi, H. (2007) · PET Clinics · doi:10.1016/j.cpet.2007.08.002 · Cited by 161
Self-citationRahmim, A., Tang, J., & Zaidi, H. (2009) · Medical Physics · doi:10.1118/1.3160108 · Cited by 155
Self-citationSchaefer, A., Kremp, S., Hellwig, D., Rübe, C., Kirsch, C., & Nestle, U. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0875-1 · Cited by 154
Rahmim, A., Dinelle, K., Cheng, J.-C. K., Shilov, M. A., Segars, W. P., Lidstone, S. C., Blinder, S. A. L., ROUSSET, O. G., Vajihollahi, H., Tsui, B. M. W., et al. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.917248 · Cited by 153
Breen, S. L., Publicover, J., Silva, S. D., et al. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.12.039 · Cited by 137
Kyriakou, Y., Riedel, T., & Kalender, W. A. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/18/008 · Cited by 136
Anatomical imaging for radiotherapy
Evans, P. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/12/r01 · Cited by 133
A novel PET tumor delineation method based on adaptive region-growing and dual-front active contours
Li, H., Thorstad, W. L., Biehl, K. J., Laforest, R. A., Su, Y., Shoghi, K. I., Donnelly, E. D., Low, D. A., & Lü, W. (2008) · Medical Physics · doi:10.1118/1.2956713 · Cited by 129
Is there a role for FGD-PET in radiotherapy planning in esophageal carcinoma?
Hamming‐Vrieze, O., Haustermans, K. M., Wever, W. D., Lerut, A., Cutsem, E. V., Ectors, N., Hiele, M. I., & Flamen, P. (2004) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2004.10.001 · Cited by 125
Concurrent multimodality image segmentation by active contours for radiotherapy treatment planninga)
Naqa, I. E., Yang, D., Apte, A., Khullar, D., Mutic, S., Zheng, J., Bradley, J. D., Grigsby, P. W., & Deasy, J. O. (2007) · Medical Physics · doi:10.1118/1.2799886 · Cited by 123
Liang, J., McInerney, T., & Terzopoulos, D. (2005) · Medical Image Analysis · doi:10.1016/j.media.2005.09.002 · Cited by 122
A Gaussian mixture model for definition of lung tumor volumes in positron emission tomography
Aristophanous, M., Penney, B. C., Martel, M. K., & Pelizzari, C. A. (2007) · Medical Physics · doi:10.1118/1.2791035 · Cited by 120
[(18)F]Fluoroethyltyrosine- positron emission tomography-guided radiotherapy for high-grade glioma
Weber, D. C., Zilli, T., Buchegger, F., Casanova, N., Haller, G., Rouzaud, M., Nouet, P., Dipasquale, G., Ratib, O. M., Zaidi, H., et al. (2008) · Radiation Oncology · doi:10.1186/1748-717x-3-44 · Cited by 118
Self-citationMultimodality image registration with software: state-of-the-art
Slomka, P. J., & Baum, R. P. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0941-8 · Cited by 118
Khoo, V. S., Adams, E., Saran, F. H., Bedford, J. L., Perks, J. R., Warrington, A. P., & Brada, M. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(99)00541-6 · Cited by 115
A novel iterative method for lesion delineation and volumetric quantification with FDG PET
van Dalen, J. A., Hoffmann, A. L., Dicken, V., Vogel, W. V., Wiering, B., Ruers, T. J. M., Karssemeijer, N., & Oyen, W. J. G. (2007) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e328155d154 · Cited by 114
Vees, H., Senthamizhchelvan, S., Miralbell, R., Weber, D. C., Ratib, O. M., & Zaidi, H. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0943-6 · Cited by 111
Self-citationTumor delineation using PET in head and neck cancers: Threshold contouring and lesion volumes
Ford, E. C., Kinahan, P. E., Hanlon, L., Alessio, A. M., Rajendran, J. G., Schwartz, D. L., & Phillips, M. H. (2006) · Medical Physics · doi:10.1118/1.2361076 · Cited by 110
Zaidi, H., Ruest, T., Schoenahl, F., & Montandon, M.-L. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.05.031 · Cited by 108
Self-citationComparison of supervised MRI segmentation methods for tumor volume determination during therapy
Vaidyanathan, M., Clarke, L. P., Velthuizen, R. P., Phuphanich, S., Bensaid, A. M., Hall, L., Bezdek, J. C., Greenberg, H., Trotti, A., & Silbiger, M. L. (1995) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(95)00012-6 · Cited by 103
Basu, S. K., Zaidi, H., Houseni, M., Bural, G. G., Udupa, J., Acton, P. D., Torigian, D. A., & Alavi, A. A. (2007) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2007.01.005 · Cited by 103
Self-citationFeasibility of Pathology-Correlated Lung Imaging for Accurate Target Definition of Lung Tumors
Stroom, J. C., Blaauwgeers, H., van Baardwijk, A. A. W., Boersma, L. J., Lebesque, J. V., Theuws, J. C. M., van Suylen, R. J., Klomp, H. M., Liesker, K. R., van Pel, R., et al. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2007.04.065 · Cited by 97
Non-Invasive PET and Spect Imaging of Tissue Hypoxia Using Isotopically Labeled 2-Nitroimidazoles
Koch, C. J., & Evans, S. M. (2003) · Advances in experimental medicine and biology · doi:10.1007/978-1-4615-0205-0_47 · Cited by 94
Radiopharmaceuticals in Preclinical and Clinical Development for Monitoring of Therapy with PET
Dunphy, M. P., & Lewis, J. S. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.057281 · Cited by 94
Three validation metrics for automated probabilistic image segmentation of brain tumours
Zou, K. H., Wells, W. M., Kikinis, R., & Warfield, S. K. (2004) · Statistics in Medicine · doi:10.1002/sim.1723 · Cited by 94
Strategies for Biologic Image-Guided Dose Escalation: A Review
Søvik, Å., Malinen, E., & Olsen, D. R. (2009) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2008.11.001 · Cited by 91
Vauclin, S., Doyeux, K., Hapdey, S., Edet‐Sanson, A., Véra, P., & Gardin, I. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/22/010 · Cited by 89
Molecular PET/CT Imaging-Guided Radiation Therapy Treatment Planning
Zaidi, H., Vees, H., & Wissmeyer, M. (2009) · Academic Radiology · doi:10.1016/j.acra.2009.02.014 · Cited by 89
Self-citationMamede, M. H., de Abreu-e-Lima, P. C., Oliva, M. R., Nosé, V., Mamon, H. J., & Gerbaudo, V. H. (2007) · American Journal of Clinical Oncology · doi:10.1097/coc.0b013e31803993f8 · Cited by 87
Review of Computational Anthropomorphic Anatomical and Physiological Models
Zaidi, H., & Tsui, B. M. W. (2009) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2032852 · Cited by 87
Self-citationImplementing biologic target volumes in radiation treatment planning for non-small cell lung cancer.
Bradley, J. D., Perez, C. A., Dehdashti, F., & Siegel, B. A. (2004) · PubMed · Cited by 83
Fuzzy hidden Markov chains segmentation for volume determination and quantitation in PET
Hatt, M., Lamare, F., Boussion, N., Turzo, A., Collet, C., Salzenstein, F., Roux, C., Jarritt, P. H., Carson, K. J., Rest, C. C. L., et al. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/12/010 · Cited by 79
Development and validation of MCNP4C-based Monte Carlo simulator for fan- and cone-beam x-ray CT
Ay, M. R., & Zaidi, H. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/20/009 · Cited by 78
Self-citationGeets, X., Daisne, J., Grégoire, V., Hamoir, M., & Lonneux, M. (2004) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2004.02.013 · Cited by 77
Molecular (functional) imaging for radiotherapy applications: an RTOG symposium
Chapman, J. D., Bradley, J. D., Eary, J. F., Haubner, R., Larson, S. M., Michalski, J. M., Okunieff, P. G., Strausś, H. W., Ung, Y., & Welch, M. J. (2003) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)04215-3 · Cited by 76
Image-Guided Cancer Therapy Using PET/CT
Yap, J. T., Carney, J., Hall, N. C., & Townsend, D. W. (2004) · The Cancer Journal · doi:10.1097/00130404-200407000-00003 · Cited by 75
Suri, J. S., Singh, S. K., & Reden, L. (2002) · Pattern Analysis and Applications · doi:10.1007/s100440200005 · Cited by 72
Computational Challenges for Image-Guided Radiation Therapy: Framework and Current Research
Xing, L., Siebers, J. V., & Keall, P. (2007) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2007.07.004 · Cited by 71
Medical image analysis with fuzzy models
Bezdek, J. C., Hall, L., Clark, M. C., Goldgof, D., & Clarke, L. P. (1997) · Statistical Methods in Medical Research · doi:10.1177/096228029700600302 · Cited by 71
Automatic segmentation of liver PET images
Hsu, C., Liu, C.-Y., & Chen, C. (2008) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2008.07.001 · Cited by 70
RT_Image: An Open-Source Tool for Investigating PET in Radiation Oncology
Graves, E. E., Quon, A. S. W., & Loo, B. W. (2007) · Technology in Cancer Research & Treatment · doi:10.1177/153303460700600207 · Cited by 68
Brambilla, M., Matheoud, R., Secco, C., Loi, G., Krengli, M., & Inglese, E. (2008) · Medical Physics · doi:10.1118/1.2870215 · Cited by 67
Deblurring of breathing motion artifacts in thoracic PET images by deconvolution methods
Naqa, I. E., Low, D. A., Bradley, J. D., Vićić, M., & Deasy, J. O. (2006) · Medical Physics · doi:10.1118/1.2336500 · Cited by 67
Ay, M. R., & Zaidi, H. (2006) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0086-6 · Cited by 62
Self-citationMaitre, A. L., Segars, W. P., Marache, S., et al. (2009) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2027925 · Cited by 61
The limitation of PET imaging for biological adaptive-IMRT assessed in animal models
Christian, N., Lee, J. A., Bol, A., Bast, M. D., Jordan, B. F., & Grégoire, V. (2008) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2008.11.014 · Cited by 61
Tumor and target delineation: Current research and future challenges
Austin-Seymour, M., Chen, G. T. Y., Rosenman, J. G., Michalski, J. M., Lindsley, K. L., & Goitein, M. (1995) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(95)00215-4 · Cited by 60
Objective comparison of quantitative imaging modalities without the use of a gold standard
Hoppin, J., Kupinski, M. A., Kastis, G. A., Clarkson, E. W., & Barrett, H. H. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.1009380 · Cited by 57
Guest Editorial Validation in Medical Image Processing
Jannin, P., Krupinski, E. A., & Warfield, S. K. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.883282 · Cited by 57
Topkan, E., Yavuz, A. A., Aydın, M., Önal, C., Yapar, A. F., & Yavuz, M. (2008) · Journal of Experimental & Clinical Cancer Research · doi:10.1186/1756-9966-27-41 · Cited by 51
Drever, L., Roa, W., McEwan, A. J. B., & Robinson, D. M. (2007) · Journal of Applied Clinical Medical Physics · doi:10.1120/jacmp.v8i2.2367 · Cited by 49
Acton, P. D., Pilowsky, L. S., Kung, H. F., & Ell, P. J. (1999) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050425 · Cited by 48
Radioactive spheres without inactive wall for lesion simulation in PET
Bazañez-Borgert, M., Bundschuh, R. A., Herz, M., Martínez, M.-J., Schwaiger, M., & Ziegler, S. I. (2007) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2007.06.001 · Cited by 40
Image Segmentation Techniques in Nuclear Medicine Imaging
Boudraa, A., & Zaidi, H. (2006) · Kluwer Academic Publishers eBooks · doi:10.1007/0-387-25444-7_10 · Cited by 38
Self-citationGreco, C., Nehmeh, S. A., Schöder, H. M., Gönen, M., Raphael, B., Stambuk, H. E., Humm, J. L., Larson, S. M., & Lee, N. Y. (2008) · American Journal of Clinical Oncology · doi:10.1097/coc.0b013e318168ef82 · Cited by 38
Aristophanous, M., Penney, B. C., & Pelizzari, C. A. (2008) · Medical Physics · doi:10.1118/1.2938518 · Cited by 37
Current Trends in PET and Combined (PET/CT and PET/MR) Systems Design
Zaidi, H., & Alavi, A. A. (2007) · PET Clinics · doi:10.1016/j.cpet.2007.10.004 · Cited by 37
Self-citationJanssen, M. H. M., Aerts, H. J. W. L., Öllers, M., et al. (2008) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2008.04.019 · Cited by 36
The problem of ROC analysis without truth: the EM algorithm and the information matrix
Beiden, S. V., Campbell, G., Meier, K. L., & Wagner, R. F. (2000) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.383099 · Cited by 32
Basu, S. K. (2009) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-1033-5 · Cited by 15
Evaluating estimation techniques in medical imaging without a gold standard: experimental validation
Hoppin, J. W., Kupinski, M. A., Wilson, D. W., Peterson, T. E., Gershman, B., Kastis, G. A., Clarkson, E. W., Furenlid, L. R., & Barrett, H. H. (2003) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.480330 · Cited by 11
The 3rd Annual Ontario Thoracic Cancer Conference at Niagara-on-the-Lake
Dahele, M. R., Ung, Y. C., Bezjak, A., Burkes, R. L., Ellis, P., Behzadi, A., Solow, H. L., Laffan, S., & Korec, M. (2008) · Current Oncology · doi:10.3747/co.v15i3.287 · Cited by 8
Validation of PET Imaging by Alignment to Histology Slices
Edwards, P., Nijmeh, A. D., McGurk, M., Odell, E. W., Fenlon, M. R., Marsden, P. K., & Hawkes, D. J. (2005) · Lecture notes in computer science · doi:10.1007/11566489_119 · Cited by 5
Methods for image segmentation should be standardized and calibrated
Chaney, E. L., Ibbott, G. S., & Hendee, W. R. (2005) · Medical Physics · doi:10.1118/1.2131093 · Cited by 5
Cited by
Erlandsson, K., Buvat, I., Pretorius, P. H., Thomas, B. A., & Hutton, B. F. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/21/r119 · Cited by 733
Beyond imaging: The promise of radiomics
Avanzo, M., Stancanello, J., & El Naqa, I. (2017) · Physica Medica · doi:10.1016/j.ejmp.2017.05.071 · Cited by 483
Self-citationOrlhac, F., Soussan, M., Maisonobe, J.-A., Garcia, C. A., Vanderlinden, B., & Buvat, I. (2014) · Journal of Nuclear Medicine · doi:10.2967/jnumed.113.129858 · Cited by 356
Positron Emission Tomography (PET) in Oncology
Gallamini, A., Zwarthoed, C., & Borra, A. (2014) · Cancers · doi:10.3390/cancers6041821 · Cited by 312
Zwanenburg, A. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04391-8 · Cited by 306
Metadata
- Authors
- Zaidi, H., & El Naqa, I.
- Venue
- European Journal of Nuclear Medicine and Molecular Imaging
- Published
- 2010-03-25
- Volume
- 37
- Issue
- 11
- Pages
- 2165-2187
- ISSN
- 1619-7070 (ISSN-L)
- 1619-7089
- OpenAlex
- W2100858680
- Cited by
- 366
- References
- 161
- FWCI
- 35.38
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.