The DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index.
EANM/EARL harmonization strategies in PET quantification: from daily practice to multicentre oncological studies
Open accessAbstract
Quantitative positron emission tomography/computed tomography (PET/CT) can be used as diagnostic or prognostic tools (i.e. single measurement) or for therapy monitoring (i.e. longitudinal studies) in multicentre studies. Use of quantitative parameters, such as standardized uptake values (SUVs), metabolic active tumor volumes (MATVs) or total lesion glycolysis (TLG), in a multicenter setting requires that these parameters be comparable among patients and sites, regardless of the PET/CT system used. This review describes the motivations and the methodologies for quantitative PET/CT performance harmonization with emphasis on the EANM Research Ltd. (EARL) Fluorodeoxyglucose (FDG) PET/CT accreditation program, one of the international harmonization programs aiming at using FDG PET as a quantitative imaging biomarker. In addition, future accreditation initiatives will be discussed. The validation of the EARL accreditation program to harmonize SUVs and MATVs is described in a wide range of tumor types, with focus on therapy assessment using either the European Organization for Research and Treatment of Cancer (EORTC) criteria or PET Evaluation Response Criteria in Solid Tumors (PERCIST), as well as liver-based scales such as the Deauville score. Finally, also presented in this paper are the results from a survey across 51 EARL-accredited centers reporting how the program was implemented and its impact on daily routine and in clinical trials, harmonization of new metrics such as MATV and heterogeneity features.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This has undermined any attempts to establish widely adoptable SUV thresholds unless rigorous harmonization measures are followed [101,103,181].”
From Influences on PET Quantification and Interpretation (2022) · cites this paper as [181]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
From RECIST to PERCIST: Evolving Considerations for PET Response Criteria in Solid Tumors
Wahl, R. L., Jacene, H., Kasamon, Y., & Lodge, M. A. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.057307 · Cited by 3,777
FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0
Boellaard, R., Delgado-Bolton, R., Oyen, W. J. G., Giammarile, F., Tatsch, K., Eschner, W., Verzijlbergen, F. J., Barrington, S. F., Pike, L. C., Weber, W. A., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-014-2961-x · Cited by 3,303
Self-citationFDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0
Boellaard, R., O’Doherty, M. J., Weber, W., Mottaghy, F. M., Lonsdale, M. N., Stroobants, S. G., Oyen, W. J. G., Kotzerke, J., Hoekstra, O. S., Pruim, J., et al. (2009) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-009-1297-4 · Cited by 1,329
Self-citationStandards for PET Image Acquisition and Quantitative Data Analysis
Boellaard, R. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.057182 · Cited by 906
Self-citationPerformance Measurements of the Siemens mMR Integrated Whole-Body PET/MR Scanner
Delso, G., Fürst, S., Jakoby, B., Ladebeck, R., Ganter, C., Nekolla, S. G., Schwaiger, M., & Ziegler, S. I. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.092726 · Cited by 870
Fully 3-D PET reconstruction with system matrix derived from point source measurements
Panin, V. Y., Kehren, F., Michel, C., & Casey, M. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.876171 · Cited by 536
Characterization of PET/CT images using texture analysis: the past, the present… any future?
Hatt, M., Tixier, F., Pierce, L. A., Kinahan, P. E., Rest, C. C. L., & Visvikis, D. (2016) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-016-3427-0 · Cited by 494
Nuyts, J. L., Dupont, P. J., Stroobants, S. G., Benninck, R., Mortelmans, L., & Suetens, P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.774167 · Cited by 361
van Baardwijk, A. A. W., Bosmans, G., Boersma, L. J., Buijsen, J., Wanders, S. L., Hochstenbag, M. M. H., van Suylen, R. J., Dekker, A. L. A. J., Oberije, C., Houben, R. M. A., et al. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.12.067 · Cited by 295
Mikhaeel, N. G., Smith, D., Dunn, J., Phillips, M., Møller, H., Fields, P. A., Wrench, D., & Barrington, S. F. (2016) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-016-3315-7 · Cited by 295
van Velden, F. H. P., Kramer, G. M., Frings, V., Nissen, I. A., Mulder, E. R., de Langen, A. J., Hoekstra, O. S., Smit, E. F., & Boellaard, R. (2016) · Molecular Imaging and Biology · doi:10.1007/s11307-016-0940-2 · Cited by 286
Self-citationFDG PET for therapy monitoring in Hodgkin and non-Hodgkin lymphomas
Barrington, S. F., & Kluge, R. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3690-8 · Cited by 281
Teoh, E. J., McGowan, D. R., Macpherson, R. E., Bradley, K. M., & Gleeson, F. V. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.159301 · Cited by 265
Samarin, A., Burger, C., Wollenweber, S. D., Crook, D. W., Burger, I. A., Schmid, D. T., von Schulthess, G. K., & Kuhn, F. P. (2012) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-012-2113-0 · Cited by 251
Grant, A. M., Deller, T. W., Khalighi, M. M., Maramraju, S. H., Delso, G., & Levin, C. S. (2016) · Medical Physics · doi:10.1118/1.4945416 · Cited by 246
Zero TE MR bone imaging in the head
Wiesinger, F., Sacolick, L. I., Menini, A., Kaushik, S. S., Ahn, S., Veit‐Haibach, P., Delso, G., & Shanbhag, D. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25545 · Cited by 241
Self-citationQuantification, improvement, and harmonization of small lesion detection with state-of-the-art PET
van der Vos, C. S., Koopman, D., Rijnsdorp, S., Arends, A. J., Boellaard, R., van Dalen, J. A., Lubberink, M., Willemsen, A. T. M., & Visser, E. P. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3727-z · Cited by 206
Self-citationA multicompartment body composition technique based on computerized tomography.
Chowdhury, B., Sjöström, L., Alpsten, M., Kostanty, J., Kvist, H., & Löfgren, R. (1994) · PubMed · Cited by 203
Pinker, K., Riedl, C. C., & Weber, W. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3687-3 · Cited by 172
Sunderland, J. J., & Christian, P. E. (2014) · Journal of Nuclear Medicine · doi:10.2967/jnumed.114.148056 · Cited by 144
Clinical Evaluation of Zero-Echo-Time MR Imaging for the Segmentation of the Skull
Delso, G., Wiesinger, F., Sacolick, L. I., Kaushik, S. S., Shanbhag, D., Hüllner, M. W., & Veit‐Haibach, P. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.114.149997 · Cited by 138
Self-citationVariations in Clinical PET/CT Operations: Results of an International Survey of Active PET/CT Users
Beyer, T., Czernin, J., & Freudenberg, L. S. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.079624 · Cited by 136
Lasnon, C., Desmonts, C., Quak, E., Gervais, R., Dô, P., Dubos‐Arvis, C., & Aide, N. (2013) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-013-2391-1 · Cited by 126
Self-citationOptimum Lean Body Formulation for Correction of Standardized Uptake Value in PET Imaging
Tahari, A. K., Chien, D. C., Azadi, J. R., & Wahl, R. L. (2014) · Journal of Nuclear Medicine · doi:10.2967/jnumed.113.136986 · Cited by 123
Lovinfosse, P., Jánváry, Z. L., Coucke, P. A., Jodogne, S., Bernard, C., Hatt, M., Visvikis, D., Jansen, N., Duysinx, B., & Hustinx, R. (2016) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-016-3314-8 · Cited by 114
Desseroit, M.-C., Visvikis, D., Tixier, F., Majdoub, M., Perdrisot, R., Guillevin, R., Rest, C. C. L., & Hatt, M. (2016) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-016-3325-5 · Cited by 109
Cheebsumon, P., Yaqub, M. M., van Velden, F. H. P., Hoekstra, O. S., Lammertsma, A. A., & Boellaard, R. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-011-1899-5 · Cited by 108
Self-citationQuak, E., Le Roux, P.-Y., Hofman, M. S., Robin, P., Bourhis, D., Callahan, J., Binns, D., Desmonts, C., Salaun, P.-Y., Hicks, R. J., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3128-0 · Cited by 107
Self-citationSummary of the UPICT Protocol for 18F-FDG PET/CT Imaging in Oncology Clinical Trials
Graham, M. M., Wahl, R. L., Hoffman, J. M., Yap, J. T., Sunderland, J. J., Boellaard, R., Perlman, E. S., Kinahan, P. E., Christian, P. E., Hoekstra, O. S., et al. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.158402 · Cited by 104
Self-citationGraham, M. M., Badawi, R. D., & Wahl, R. L. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.074104 · Cited by 101
Sekine, T., Buck, A., Delso, G., ter Voert, E. E. G. W., Huellner, M. W., Veit‐Haibach, P., & Warnock, G. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.159228 · Cited by 94
Self-citationParvizi, N., Franklin, J. M., McGowan, D. R., Teoh, E., Bradley, K. M., & Gleeson, F. V. (2015) · European Journal of Radiology · doi:10.1016/j.ejrad.2015.06.025 · Cited by 91
Kalemis, A., Delattre, B. M. A., & Heinzer-Schweizer, S. (2012) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-012-0330-y · Cited by 88
Accurate PET/MR Quantification Using Time of Flight MLAA Image Reconstruction
Boellaard, R., Hofman, M. B. M., Hoekstra, O. S., & Lammertsma, A. A. (2014) · Molecular Imaging and Biology · doi:10.1007/s11307-013-0716-x · Cited by 87
Self-citationLeynes, A. P., Yang, J., Shanbhag, D., Kaushik, S. S., Seo, Y., Hope, T. A., Wiesinger, F., & Larson, P. E. Z. (2017) · Medical Physics · doi:10.1002/mp.12122 · Cited by 82
Mutatis Mutandis: Harmonize the Standard!
Boellaard, R. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.094763 · Cited by 78
Self-citationCheebsumon, P., Boellaard, R., Ruysscher, D. D., van Elmpt, W., van Baardwijk, A. A. W., Yaqub, M. M., Hoekstra, O. S., Comans, E. F. I., Lammertsma, A. A., & van Velden, F. H. P. (2012) · EJNMMI Research · doi:10.1186/2191-219x-2-56 · Cited by 75
Self-citationMulticenter Harmonization of 89Zr PET/CT Performance
Makris, N. E., Boellaard, R., Visser, E. P., de Jong, J. R., Vanderlinden, B., Wierts, R., der Veen, B. J. D. W., Greuter, H. N. J. M., Vugts, D. J., van Dongen, G. A. M. S., et al. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.113.130112 · Cited by 69
Self-citationCheebsumon, P., van Velden, F. H. P., Yaqub, M. M., Frings, V., de Langen, A. J., Hoekstra, O. S., Lammertsma, A. A., & Boellaard, R. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.088914 · Cited by 68
Self-citationBeyer, T., Lassen, M. L., Boellaard, R., Delso, G., Yaqub, M., Sattler, B., & Quick, H. H. (2016) · Magnetic Resonance Materials in Physics, Biology and Medicine · doi:10.1007/s10334-015-0505-4 · Cited by 66
Self-citationKuhnert, G., Boellaard, R., Sterzer, S., Kahraman, D., Scheffler, M., Wolf, J., Dietlein, M., Drzezga, A. E., & Kobe, C. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3165-8 · Cited by 65
Self-citationBoellaard, R., Rausch, I., Beyer, T., Delso, G., Yaqub, M., Quick, H. H., & Sattler, B. (2015) · Medical Physics · doi:10.1118/1.4930962 · Cited by 62
Self-citationZiegler, S., Jakoby, B., Braun, H., Paulus, D. H., & Quick, H. H. (2015) · EJNMMI Physics · doi:10.1186/s40658-015-0122-3 · Cited by 60
SUVref: reducing reconstruction-dependent variation in PET SUV
Kelly, M. D., & Declerck, J. M. (2011) · EJNMMI Research · doi:10.1186/2191-219x-1-16 · Cited by 58
Bellèvre, D., Blanc‐Fournier, C., Switsers, O., Dugué, A. E., Lévy, C., Allouache, D., Desmonts, C., Crouet, H., Guilloit, J., Grellard, J., et al. (2014) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-014-2689-7 · Cited by 58
Self-citationCurrent Image Acquisition Options in PET/MR
Boellaard, R., & Quick, H. H. (2015) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2014.12.001 · Cited by 56
Self-citationLasnon, C., Majdoub, M., Lavigne, B., Dô, P., Madelaine, J., Visvikis, D., Hatt, M., & Aide, N. (2016) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-016-3441-2 · Cited by 53
Self-citationErselcan, T., Turgut, B., Doğan, D. Ö., & Özdemir, S. (2002) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-0974-3 · Cited by 44
Does PET SUV Harmonization Affect PERCIST Response Classification?
Quak, E., Roux, P. L., Lasnon, C., Robin, P., Hofman, M. S., Bourhis, D., Callahan, J., Binns, D., Desmonts, C., Salaün, P., et al. (2016) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.171983 · Cited by 41
Self-citationLasnon, C., Salomon, T., Desmonts, C., Dô, P., Oulkhouir, Y., Madelaine, J., & Aide, N. (2016) · Annals of Nuclear Medicine · doi:10.1007/s12149-016-1135-2 · Cited by 41
Self-citationBurgos, N., Cardoso, M. J., Thielemans, K., Marc Modat, A., Dickson, J. C., Schott, J. M., Atkinson, D., Arridge, S., Hutton, B. F., & Sebastien Ourselin, A. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3082-x · Cited by 37
Lasnon, C., Enilorac, B., Popotte, H., & Aide, N. (2017) · EJNMMI Research · doi:10.1186/s13550-017-0279-y · Cited by 35
Self-citationA Digital Reference Object to Analyze Calculation Accuracy of PET Standardized Uptake Value
Pierce, L. A., Elston, B. F., Clunie, D., Nelson, D. P., & Kinahan, P. E. (2015) · Radiology · doi:10.1148/radiol.2015141262 · Cited by 35
Bergmann, H., Geist, B. K., Schaffarich, M. P., Hirtl, A., Hacker, M., Beyer, T., & Rausch, I. (2014) · Nuklearmedizin - NuclearMedicine · doi:10.3413/nukmed-0665-14-05 · Cited by 33
Rausch, I., Bergmann, H., Geist, B. K., Schaffarich, M. P., Hirtl, A., Hacker, M., & Beyer, T. (2014) · Nuklearmedizin - NuclearMedicine · Cited by 27
Lasnon, C., Quak, E., Roux, P. L., Robin, P., Hofman, M. S., Bourhis, D., Callahan, J., Binns, D., Desmonts, C., Salaün, P., et al. (2017) · EJNMMI Physics · doi:10.1186/s40658-017-0185-4 · Cited by 27
Self-citationQuak, E., Hovhannisyan, N., Lasnon, C., Fruchart, C., Vilque, J., Musafiri, D., & Aide, N. (2014) · Haematologica · doi:10.3324/haematol.2014.104125 · Cited by 25
Self-citationYang, J., Jian, Y., Jenkins, N. W., Behr, S. C., Hope, T. A., Larson, P. E. Z., Vigneron, D. B., & Seo, Y. (2017) · Radiology · doi:10.1148/radiol.2017161603 · Cited by 22
Methodological Aspects of Multicenter Studies with Quantitative PET
Boellaard, R. (2011) · Methods in molecular biology · doi:10.1007/978-1-61779-062-1_18 · Cited by 21
Self-citationKim, W. H., Kim, C. G., & Kim, D. (2012) · Nuclear Medicine and Molecular Imaging · doi:10.1007/s13139-012-0146-8 · Cited by 20
Lasnon, C., Houdu, B., Kammerer, E., Salomon, T., Devreese, J., Lebasnier, A., & Aide, N. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3214-3 · Cited by 17
Self-citationDecazes, P., Métivier, D., Rouquette, A., Talbot, J., & Kerrou, K. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.164913 · Cited by 16
Devriese, J., Beels, L., Maes, A. F., Wiele, C. V. D., Gheysens, O. S., & Pottel, H. (2016) · PubMed · Cited by 11
Burgos, N., Cardoso, M. J., Marc Modat, A., Punwani, S., Atkinson, D., Arridge, S., Hutton, B. F., & Sebastien Ourselin, A. (2015) · EJNMMI Physics · doi:10.1186/2197-7364-2-s1-a31 · Cited by 7
Research works printed but not linked: 2
- Quak E, Le Roux PY, Hofman MS, Robin P, Bourhis D, Callahan J, et al. Harmonizing FDG PET quantification while maintaining optimal lesion detection: prospective multicentre validation in 517 oncology patients. Eur J Nucl med Mol Imaging. 2015;42:2072–82. doi: 10.1007/s00259-015-3128-0 . · DOI · Paper page
- Barrington SF, Kluge R. FDG-PET for therapy monitoring in Hodgkin and non-Hodgkin lymphoma. Eur J Nucl Med Mol Imaging. 2017. doi: 10.1007/s00259-017-3690-8 . · DOI
Cited by
Sorted by citations
FDG PET/CT for assessing tumour response to immunotherapy
Aide, N., Hicks, R. J., Tourneau, C. L., Lheureux, S., Fanti, S., & Lopci, E. (2018) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-4171-4 · Cited by 266
Self-citationPapadimitroulas, P., Brocki, L., Christopher Chung, N., Marchadour, W., Vermet, F., Gaubert, L., Eleftheriadis, V., Plachouris, D., Visvikis, D., Kagadis, G. C., et al. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.03.009 · Cited by 226
Quantification, improvement, and harmonization of small lesion detection with state-of-the-art PET
van der Vos, C. S., Koopman, D., Rijnsdorp, S., Arends, A. J., Boellaard, R., van Dalen, J. A., Lubberink, M., Willemsen, A. T. M., & Visser, E. P. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3727-z · Cited by 206
Self-citationHarmonization strategies for multicenter radiomics investigations
Da‐ano, R., Visvikis, D., & Hatt, M. (2020) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aba798 · Cited by 167
Albert, N. L., Galldiks, N., Ellingson, B. M., van den Bent, M. J., Chang, S. M., Cicone, F., de Groot, J., Koh, E., Law, I. G., Rhun, É. L., et al. (2024) · The Lancet Oncology · doi:10.1016/s1470-2045(23)00525-9 · Cited by 198
Metadata
- Authors
- Aide, N., Lasnon, C., Veit-Haibach, P., Sera, T., Sattler, B., & Boellaard, R.
- Affiliations
- Inserm (FR)
- University Hospital Leipzig (DE)
- University Medical Center Groningen (NL)
- Corresponding author
- Aide, Nicolas
- Venue
- European Journal of Nuclear Medicine and Molecular Imaging
- Published
- 2017-06-16
- Volume
- 44
- Issue
- S1
- Pages
- 17-31
- ISSN
- 1619-7070 (ISSN-L)
- 1619-7089
- PMC
- PMC5541084
- OpenAlex
- W2625583840
- Cited by
- 344
- References
- 64
- Citations by year
- 2026: 37 · 2025: 49 · 2024: 37 · 2023: 33 · 2022: 30 · 2021: 54 · 2020: 32 · 2019: 26 · 2018: 33 · 2017: 12
- FWCI
- 4.26
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- European Journal of Nuclear Medicine and Molecular Imaging (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion, other-oa)
- Amsterdam UMC (VU Amsterdam) - Institutional Repository (publishedVersion)
- University of Groningen research database (University of Groningen / Centre for Information Technology) (publishedVersion, cc-by)
- SZTE Publicatio Repozitórium (University of Szeged) (acceptedVersion, other-oa)
- Zurich Open Repository and Archive (University of Zurich) (acceptedVersion, cc-by)
- HAL (submittedVersion, other-oa)
- Zurich Open Repository and Archive (University of Zurich) (submittedVersion, cc-by)
- University of Groningen research database (University of Groningen / Centre for Information Technology) (submittedVersion, cc-by)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Zurich Open Repository and Archive (University of Zurich)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Lung Cancer Diagnosis and Treatment
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
- Keywords
- PET quantification, method harmonization, FDG PET/CT, standardized uptake value, total lesion glycolysis, therapy response assessment, EORTC criteria, PERCIST, Deauville score, imaging biomarkers
- MeSH terms
- Humans, Magnetic Resonance Imaging, Neoplasms, Reference Standards, Societies, Medical, Multicenter Studies as Topic, Positron-Emission Tomography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review