Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose)
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222 · cited 3×
“CT examinations represent only 4–6% of all X-ray-based imaging studies in Germany [1] and in Britain [2].”
BackgroundDonnelly, L. F., Emery, K. H., Brody, A. S., Laor, T., Gylys-Morin, V. M., Anton, C. G., Thomas, S. R., & Frush, D. P. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760303 · Cited by 480 · cited 2×
“The major disadvantage of decreasing the mAs, they described, is an increase in noise and the associated potential for degradation of image quality [18].”
BackgroundHelical CT of the Body: Are Settings Adjusted for Pediatric Patients?
Paterson, A., Frush, D. P., & Donnelly, L. F. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760297 · Cited by 422 · cited 1×
“Paediatric spiral CT parameters are not adjusted on the basis of the examination type or age of the child [7].”
BackgroundDose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies
Gies, M., Kalender, W. A., Wolf, H., Suess, C., & Madsen, M. T. (1999) · Medical Physics · doi:10.1118/1.598779 · Cited by 306
Self-citationKalender, W. A., Wolf, H., Suess, C., Gies, M., Greess, H., & Bautz, W. A. (1999) · European Radiology · doi:10.1007/s003300050674 · Cited by 245 · cited 2×
“Our results agree well with previous cadaver examinations [11] and the results of our previous pa-”
BackgroundResultSelf-citationGreess, H., Wolf, H., Baum, U., Lell, M., Pirkl, M., Kalender, W., & Bautz, W. A. (2000) · European Radiology · doi:10.1007/s003300050062 · Cited by 230 · cited 2×
“In our previous patient study the average mAs reductions for adults were 22% in the thorax scan region and 15% in the abdomen scan region, and 25% in the pelvis scan region [13], respectively, compared with 23% in the thorax and the abdomen scan region for children, and 22% in the combined scan region of thorax and ab…”
BackgroundResultSelf-citationRadiation Effective Doses to Patients Undergoing Abdominal CT Examinations
Ware, D. E., Huda, W., Mergo, P. J., & Litwiller, A. L. (1999) · Radiology · doi:10.1148/radiology.210.3.r99mr05645 · Cited by 153 · cited 1×
“concern to the medical community [3,4], especially because the radiosensitivity of children is higher than that of adults [5]; thus, for paediatric imaging, it is of the ut-”
BackgroundKaul, A., Bauer, B., Bernhardt, J., Noßke, D., & Veit, R. (1997) · European Radiology · doi:10.1007/s003300050267 · Cited by 91 · cited 5×
“In the United States we H. Greess (✉ ) · A. Nömayr · U. Baum M. Lell · B. Böwing · W.A. Bautz Institute of Diagnostic Radiology, Friedrich Alexander University Erlangen–Nuremberg, Maximiliansplatz 1, 91054 Erlangen, Germany e-mail: holger.greess@idr.imed.uni-erlangen.de Tel.”
BackgroundInfluentialFeasibility of high-resolution, low-dose chest CT in evaluating the pediatric chest
Ambrosino, M. M., Genieser, N. B., Roche, K. J., Kaul, A., & Lawrence, R. M. (1994) · Pediatric Radiology · doi:10.1007/bf02017649 · Cited by 82
Rogers, L. F. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760287 · Cited by 80 · cited 3×
“The reason for the excess radiation dose is the common practice of using the same X-ray exposure factors for CT examinations of children as those used for adults [6].”
Background
Cited by
Strategies for CT Radiation Dose Optimization
Kalra, M. K., Maher, M. M., Toth, T. L., Hamberg, L. M., Blake, M. A., Shepard, J.-A., & Saini, S. (2004) · Radiology · doi:10.1148/radiol.2303021726 · Cited by 1,080
Accuracy of MSCT coronary angiography with 64-slice technology: first experience
Leschka, S., Alkadhi, H., Plass, A., Desbiolles, L., Grünenfelder, J., Marincek, B., & Wildermuth, S. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi261 · Cited by 960
Techniques and Applications of Automatic Tube Current Modulation for CT
Kalra, M. K., Maher, M. M., Toth, T. L., Schmidt, B., Westerman, B. L., Morgan, H. T., & Saini, S. (2004) · Radiology · doi:10.1148/radiol.2333031150 · Cited by 725
CT Dose Index and Patient Dose: They Are Not the Same Thing
McCollough, C. H., Leng, S., Yu, L., Cody, D. D., Boone, J. M., & McNitt-Gray, M. F. (2011) · Radiology · doi:10.1148/radiol.11101800 · Cited by 463
CT Angiography for Diagnosis of Pulmonary Embolism: State of the Art
Schoepf, U. J., & Costello, P. (2004) · Radiology · doi:10.1148/radiol.2302021489 · Cited by 407
ICRP Publication 121: Radiological Protection in Paediatric Diagnostic and Interventional Radiology
Khong, P.-L., Ringertz, H., Donoghue, V., Frush, D., Rehani, M., Appelgate, K., & Sanchez, R. (2013) · Annals of the ICRP · doi:10.1016/j.icrp.2012.10.001 · Cited by 363
Mulkens, T. H., Bellinck, P., Baeyaert, M., Ghysen, D., Van Dijck, X., Mussen, E., Venstermans, C., & Termote, J.-L. (2005) · Radiology · doi:10.1148/radiol.2363041220 · Cited by 354
Radiation Dose Reduction in Chest CT: A Review
Kubo, T., Lin, P.-J. P., Stiller, W., Takahashi, M., Kauczor, H.-U., Ohno, Y., & Hatabu, H. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.2556 · Cited by 256
Low-Dose Unenhanced Multidetector CT of Patients with Suspected Renal Colic
Tack, D., Sourtzis, S., Delpierre, I., de Maertelaer, V., & Gevenois, P. A. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.180.2.1800305 · Cited by 225
Assessment of radiation dose awareness among pediatricians
Thomas, K. E., Parnell-Parmley, J. E., Haidar, S., Moineddin, R., Charkot, E., BenDavid, G., & Krajewski, C. (2006) · Pediatric Radiology · doi:10.1007/s00247-006-0170-x · Cited by 196
“In general, multislice technology has increased the dose received by children [26, 27], and though some more recent technological advances such as mAs modulation offer hope for dose reduction [28], these are not yet in widespread use.”
BackgroundKalra, M. K., Maher, M. M., Toth, T. L., Kamath, R. S., Halpern, E. F., & Saini, S. (2004) · Radiology · doi:10.1148/radiol.2322031304 · Cited by 180
Lell, M. M., May, M., Deak, P., Alibek, S., Kuefner, M., Kuettner, A., Köhler, H., Achenbach, S., Uder, M., & Radkow, T. (2011) · Investigative Radiology · doi:10.1097/rli.0b013e3181f33b1d · Cited by 166
Self-citationCT Radiation Dose: Current Controversies and Dose Reduction Strategies
Costello, J. E., Cecava, N. D., Tucker, J. E., & Bau, J. L. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9720 · Cited by 159
“This can be similarly achieved with a low fixed tube current [23, 55] or use of ATCM techniques [38, 56], though modulation parameters, such as current range, must be adjusted to account for small pediatric BMI.”
Metadata
- Authors
- Greess, H., Nömayr, A., Wolf, H., Baum, U., Lell, M., Böwing, B., Kalender, W., & Bautz, W. A.
- Venue
- European Radiology
- Published
- 2002-02-02
- Volume
- 12
- Issue
- 6
- Pages
- 1571-1576
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W1985939449
- Cited by
- 192
- References
- 10
- FWCI
- 14.94
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.