The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
CT Angiography for Diagnosis of Pulmonary Embolism: State of the Art
Abstract
In daily clinical routine, computed tomography (CT) has practically become the first-line modality for imaging of pulmonary circulation in patients suspected of having pulmonary embolism (PE). However, limitations regarding accurate diagnosis of small peripheral emboli have so far prevented unanimous acceptance of CT as the reference standard for imaging of PE. The development of multi-detector row CT has led to improved visualization of peripheral pulmonary arteries and detection of small emboli. The finding of a small isolated clot at pulmonary CT angiography, however, may be increasingly difficult to correlate with results of other imaging modalities, and the clinical importance of such findings is uncertain. Therefore, the most realistic scenario to measure efficacy of pulmonary CT angiography when PE is suspected may be assessment of patient outcome. Meanwhile, the high negative predictive value of a normal pulmonary CT angiographic study and its association with beneficial patient outcome has been demonstrated. While the introduction of multi-detector row technology has improved CT diagnosis of PE, it has also challenged its users to develop strategies for optimized contrast material delivery, reduction of radiation dose, and management of large-volume data sets created at those examinations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wells, P. S., Anderson, D. R., Rodger, M., Stiell, I., Dreyer, J. F., Barnes, D., Forgie, M., Kovacs, G., Ward, J., & Kovacs, M. J. (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-135-2-200107170-00010 · Cited by 1,438
Remy-Jardin, M., Remy, J., Wattinne, L., & Giraud, F. (1992) · Radiology · doi:10.1148/radiology.185.2.1410342 · Cited by 788
Complications and validity of pulmonary angiography in acute pulmonary embolism.
Stein, P. D., Athanasoulis, C., Alavi, A., Greenspan, R. H., Hales, C. A., Saltzman, H. A., Vreim, C. E., Terrin, M. L., & Weg, J. G. (1992) · Circulation · doi:10.1161/01.cir.85.2.462 · Cited by 669
Four Multidetector-Row Helical CT: Image Quality and Volume Coverage Speed
Hu, H., He, H. D., Foley, W. D., & Fox, S. H. (2000) · Radiology · doi:10.1148/radiology.215.1.r00ap3755 · Cited by 509
Diagnosis of Pulmonary Embolism with Magnetic Resonance Angiography
Meaney, J. F. M., Weg, J. G., Chenevert, T. L., Stafford-Johnson, D., Hamilton, B. H., & Prince, M. R. (1997) · New England Journal of Medicine · doi:10.1056/nejm199705153362004 · Cited by 482
Performance evaluation of a multi-slice CT system
McCollough, C. H., & Zink, F. E. (1999) · Medical Physics · doi:10.1118/1.598777 · Cited by 386
Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements
Kalender, W. A., Wolf, H., & Suess, C. (1999) · Medical Physics · doi:10.1118/1.598738 · Cited by 345
Peripheral Pulmonary Arteries: How Far in the Lung Does Multi-Detector Row Spiral CT Allow Analysis?
Ghaye, B., Szapiro, D., Mastora, I., Delannoy, V., Duhamel, A., Remy, J., & Remy-Jardin, M. (2001) · Radiology · doi:10.1148/radiology.219.3.r01jn32629 · Cited by 344
A Noninvasive Strategy for the Treatment of Patients With Suspected Pulmonary Embolism
Hull, R. D. (1994) · Archives of Internal Medicine · doi:10.1001/archinte.154.3.289 · Cited by 309
Cited by
Machine learning for medical imaging
Erickson, B. J., Korfiatis, P., Akkus, Z., & Kline, T. L. (2017) · RadioGraphics · doi:10.1148/rg.2017160130 · Cited by 1,672
Machine learning and radiology
Wang, S., & Summers, R. M. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.02.005 · Cited by 697
Schoepf, U. J., Kucher, N., Kipfmueller, F., Quiroz, R., Costello, P., & Goldhaber, S. Z. (2004) · Circulation · doi:10.1161/01.cir.0000147612.59751.4c · Cited by 489
Self-citationBajc, M., Neilly, J. B., Miniati, M., Schuemichen, C., Meignan, M., & Jonson, B. (2009) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-009-1170-5 · Cited by 358
Quiroz, R., Kucher, N., Schoepf, U. J., Kipfmueller, F., Solomon, S. D., Costello, P., & Goldhaber, S. Z. (2004) · Circulation · doi:10.1161/01.cir.0000129302.90476.bc · Cited by 355
Self-citation
Metadata
- Authors
- Schoepf, U. J., & Costello, P.
- Venue
- Radiology
- Published
- 2004-02
- Volume
- 230
- Issue
- 2
- Pages
- 329-337
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1972070393
- Cited by
- 407
- References
- 19
- FWCI
- 24.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CT Angiography for Diagnosis of Pulmonary Embolism: State of the Art. https://app.cochat.ai/papers/10.1148/radiol.2302021489
- The paper
- Schoepf, U. J., & Costello, P. (2004). CT Angiography for Diagnosis of Pulmonary Embolism: State of the Art. Radiology. https://doi.org/10.1148/radiol.2302021489
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.