Inadequacy of manual measurements compared to automated CT volumetry in assessment of treatment response of pulmonary metastases using RECIST criteria
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Statistical Methods for Rates and Proportions
Fleiss, J. L., Levin, B., & Paik, M. C. (2003) · Wiley Series in Probability and Statistics · doi:10.1002/0471445428 · Cited by 18,646
New Guidelines to Evaluate the Response to Treatment in Solid Tumors
Therasse, P., Arbuck, S. G., Eisenhauer, E. A., Wanders, J., Kaplan, R. S., Rubinstein, L., Verweij, J., Van Glabbeke, M., van Oosterom, A. T., Christian, M. C., et al. (2000) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/92.3.205 · Cited by 15,660
Practical Statistics for Medical Research.
Walter, S. D., & Altman, D. G. (1992) · Biometrics · doi:10.2307/2532320 · Cited by 11,668 · cited 1×
“Extended κ values for more than two raters were calculated as described by Fleiss and coworkers [12].”
MethodPractical Statistics for Medical Research
Altman, D. G. (1990) · doi:10.1201/9780429258589 · Cited by 10,668
Statistical Methods for Rates and Proportions.
Everitt, B. S., & Fleiss, J. L. (1981) · Biometrics · doi:10.2307/2530193 · Cited by 8,990
Reporting results of cancer treatment
Miller, A. B., Hoogstraten, B., Staquet, M., & Winkler, A. (1981) · Cancer · doi:10.1002/1097-0142(19810101)47:1<207::aid-cncr2820470134>3.0.co;2-6 · Cited by 7,793 · cited 1×
“In the 1970s, the World Health Organization (WHO) proposed uniform guidelines using bidimensional methods for evaluation of tumour response, which were based on manual measurements of the longest perpendicular tumour diameter in the axial plane [1].”
MethodPractical Statistics for Medical Research.
Bartko, J. J., & Altman, D. G. (1992) · Journal of the American Statistical Association · doi:10.2307/2290246 · Cited by 4,797
Small Pulmonary Nodules: Volumetrically Determined Growth Rates Based on CT Evaluation
Yankelevitz, D. F., Reeves, A. P., Kostis, W. J., Zhao, B., & Henschke, C. I. (2000) · Radiology · doi:10.1148/radiology.217.1.r00oc33251 · Cited by 579 · cited 3×
“In phantom studies and preliminary clinical settings, automated volumetry has been demonstrated to produce minimal errors, thus maintaining very high measurement reproducibility [6, 7, 20].”
BackgroundA biomathematical approach to clinical tumor growth
Schwartz, M. (1961) · Cancer · doi:10.1002/1097-0142(196111/12)14:6<1272::aid-cncr2820140618>3.0.co;2-h · Cited by 548 · cited 1×
“For an average metastasis size of 522mm(3) in this study and assuming a standard follow-up interval of 3 months, the calculated equivalent volume doubling times, resulting from the above 95% limits of interobserver agreement, would lie between 3,443 and 3,798 days, which is typical of benign lesions [20, 22].”
BackgroundErasmus, J. J., Gladish, G. W., Broemeling, L., Sabloff, B. S., Truong, M. T., Herbst, R. S., & Munden, R. F. (2003) · Journal of Clinical Oncology · doi:10.1200/jco.2003.01.144 · Cited by 476
Large sample variance of kappa in the case of different sets of raters.
Fleiss, J. L., Nee, J. C., & Landis, J. R. (1979) · Psychological Bulletin · doi:10.1037//0033-2909.86.5.974 · Cited by 398
Are Two-dimensional CT Measurements of Small Noncalcified Pulmonary Nodules Reliable?
Revel, M.-P., Bissery, A., Bienvenu, M., Aycard, L., Lefort, C., & Frija, G. (2004) · Radiology · doi:10.1148/radiol.2312030167 · Cited by 345 · cited 1×
“79 mm for first and second manual measurements respectively) clearly lie outside clinical acceptability, though they remain within the range of those reported by other investigators [5].”
ResultVolumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility
Wormanns, D., Kohl, G., Klotz, E., Marheine, A., Beyer, F., Heindel, W., & Diederich, S. (2004) · European Radiology · doi:10.1007/s00330-003-2132-0 · Cited by 289 · cited 2×
“In phantom studies and preliminary clinical settings, automated volumetry has been demonstrated to produce minimal errors, thus maintaining very high measurement reproducibility [6, 7, 20].”
BackgroundSelf-citationRatain, M. J., & Eckhardt, S. G. (2004) · Journal of Clinical Oncology · doi:10.1200/jco.2004.07.960 · Cited by 227 · cited 1×
“depict by conventional methods [4].”
Kostis, W. J., Yankelevitz, D. F., Reeves, A. P., Fluture, S. C., & Henschke, C. I. (2004) · Radiology · doi:10.1148/radiol.2312030553 · Cited by 206 · cited 1×
“In phantom studies and preliminary clinical settings, automated volumetry has been demonstrated to produce minimal errors, thus maintaining very high measurement reproducibility [6, 7, 20].”
BackgroundThiesse, P., Ollivier, L., Di Stefano-Louineau, D., Négrier, S., Savary, J., Pignard, K., Lasset, C., & Escudier, B. (1997) · Journal of Clinical Oncology · doi:10.1200/jco.1997.15.12.3507 · Cited by 168 · cited 1×
“In one study, manual measurement inaccuracy could be demonstrated to account for as many as 45% of misclassifications, along with other examiner-related errors [13].”
BackgroundWarr, D. G., McKinney, S., & Tannock, I. F. (1984) · Journal of Clinical Oncology · doi:10.1200/jco.1984.2.9.1040 · Cited by 151 · cited 1×
“These criteria were revised in 1994 to the “Response Evaluation Criteria in Solid Tumours” (RE CIST) using unidimensional manual measurements of the sum of the longest marker lesion diameters [2, 3].”
MethodMarten, K., Seyfarth, T., Auer, F., Wiener, E., Grillh�sl, A., Obenauer, S., Rummeny, E., & Engelke, C. (2004) · European Radiology · doi:10.1007/s00330-004-2389-y · Cited by 64 · cited 1×
“Like computer-aided algorithms for detection of pulmonary nodules, automated volumetry used for size assessment of solid tumours is a relatively new technology [7, 8, 16, 17].”
Self-citationMarten, K., Grillh�sl, A., Seyfarth, T., Obenauer, S., Rummeny, E. J., & Engelke, C. (2004) · European Radiology · doi:10.1007/s00330-004-2544-5 · Cited by 49 · cited 1×
“Like computer-aided algorithms for detection of pulmonary nodules, automated volumetry used for size assessment of solid tumours is a relatively new technology [7, 8, 16, 17].”
MethodSelf-citation
Cited by
Horeweg, N., van Rosmalen, J., Heuvelmans, M. A., van der Aalst, C. M., Vliegenthart, R., Scholten, E. T., ten Haaf, K., Nackaerts, K., Lammers, J.-W. J., Weenink, C., et al. (2014) · The Lancet Oncology · doi:10.1016/s1470-2045(14)70389-4 · Cited by 526
Pulmonary Ground-Glass Nodules: Increase in Mass as an Early Indicator of Growth
de Hoop, B., Gietema, H., van de Vorst, S., Murphy, K., van Klaveren, R. J., & Prokop, M. (2010) · Radiology · doi:10.1148/radiol.09090571 · Cited by 213
Lung nodules: size still matters
Larici, A. R., Farchione, A., Franchi, P., Ciliberto, M., Cicchetti, G., Calandriello, L., del Ciello, A., & Bonomo, L. (2017) · European Respiratory Review · doi:10.1183/16000617.0025-2017 · Cited by 201
RECIST revised: implications for the radiologist. A review article on the modified RECIST guideline
van Persijn van Meerten, E. L., Gelderblom, H., & Bloem, J. L. (2010) · European Radiology · doi:10.1007/s00330-009-1685-y · Cited by 191
“Marten [24] reported significantly better inter- and intra-observer variability and treatment response assessment for semi-automated than for manual volumetric measurements in small pulmonary metastases.”
Backgroundvan Riel, S. J., Sánchez, C. I., Bankier, A. A., Naidich, D. P., Verschakelen, J., Scholten, E. T., de Jong, P. A., Jacobs, C., van Rikxoort, E., Peters-Bax, L., et al. (2015) · Radiology · doi:10.1148/radiol.2015142700 · Cited by 189
Metadata
- Authors
- Marten, K., Auer, F., Schmidt, S., Kohl, G., Rummeny, E. J., & Engelke, C.
- Venue
- European Radiology
- Published
- 2005-12-06
- Volume
- 16
- Issue
- 4
- Pages
- 781-790
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W2023890601
- Cited by
- 162
- References
- 20
- FWCI
- 5.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.