A comparison of six software packages for evaluation of solid lung nodules using semi-automated volumetry: What is the minimum increase in size to detect growth in repeated CT examinations
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
We compared interexamination variability of CT lung nodule volumetry with six currently available semi-automated software packages to determine the minimum change needed to detect the growth of solid lung nodules. We had ethics committee approval. To simulate a follow-up examination with zero growth, we performed two low-dose unenhanced CT scans in 20 patients referred for pulmonary metastases. Between examinations, patients got off and on the table. Volumes of all pulmonary nodules were determined on both examinations using six nodule evaluation software packages. Variability (upper limit of the 95% confidence interval of the Bland-Altman plot) was calculated for nodules for which segmentation was visually rated as adequate. We evaluated 214 nodules (mean diameter 10.9 mm, range 3.3 mm-30.0 mm). Software packages provided adequate segmentation in 71% to 86% of nodules (p < 0.001). In case of adequate segmentation, variability in volumetry between scans ranged from 16.4% to 22.3% for the various software packages. Variability with five to six software packages was significantly less for nodules >or=8 mm in diameter (range 12.9%-17.1%) than for nodules <8 mm (range 18.5%-25.6%). Segmented volumes of each package were compared to each of the other packages. Systematic volume differences were detected in 11/15 comparisons. This hampers comparison of nodule volumes between software packages.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
New Guidelines to Evaluate the Response to Treatment in Solid Tumors
Therasse, P., Arbuck, S. G., Eisenhauer, E. A., Wanders, J., Kaplan, R. S., Rubinstein, L., Verweij, J., Van Glabbeke, M., van Oosterom, A. T., Christian, M. C., et al. (2000) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/92.3.205 · Cited by 15,660 · cited 2×
“They are the major radiographic indicator of lung cancer and metastatic disease, despite the fact that most of them are caused by benign conditions [1–3].”
BackgroundMacMahon, H., Austin, J. H. M., Gamsu, G., Herold, C. J., Jett, J. R., Naidich, D. P., Patz, E. F., & Swensen, S. J. (2005) · Radiology · doi:10.1148/radiol.2372041887 · Cited by 1,574 · cited 2×
“[6].”
MethodSmall Pulmonary Nodules: Volumetrically Determined Growth Rates Based on CT Evaluation
Yankelevitz, D. F., Reeves, A. P., Kostis, W. J., Zhao, B., & Henschke, C. I. (2000) · Radiology · doi:10.1148/radiology.217.1.r00oc33251 · Cited by 579 · cited 3×
“They are the major radiographic indicator of lung cancer and metastatic disease, despite the fact that most of them are caused by benign conditions [1–3].”
BackgroundMethodVolumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility
Wormanns, D., Kohl, G., Klotz, E., Marheine, A., Beyer, F., Heindel, W., & Diederich, S. (2004) · European Radiology · doi:10.1007/s00330-003-2132-0 · Cited by 289 · cited 3×
“studies showed that a large degree of the interexamination variability of nodule volumetry can be explained by segmentation errors [4, 5], which were found to be common in irregularly shaped nodules.”
BackgroundMethodKostis, W. J., Yankelevitz, D. F., Reeves, A. P., Fluture, S. C., & Henschke, C. I. (2004) · Radiology · doi:10.1148/radiol.2312030553 · Cited by 206
Goodman, L. R., Gülsün, M., Washington, L., Nagy, P. G., & Piacsek, K. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.04.1821 · Cited by 144 · cited 1×
“[9].”
Gietema, H. A., Schaefer‐Prokop, C. M., Mali, W. P. T. M., Groenewegen, G., & Prokop, M. (2007) · Radiology · doi:10.1148/radiol.2452061054 · Cited by 137 · cited 2×
“, inspiration depth) and the software algorithm [4].”
BackgroundMethodSelf-citationComputer-aided detection and automated CT volumetry of pulmonary nodules
Marten, K., & Engelke, C. (2006) · European Radiology · doi:10.1007/s00330-006-0410-3 · Cited by 71 · cited 2×
“They are the major radiographic indicator of lung cancer and metastatic disease, despite the fact that most of them are caused by benign conditions [1–3].”
Background
Cited by
MacMahon, H., Naidich, D. P., Goo, J. M., Lee, K. S., Leung, A. N. C., Mayo, J. R., Mehta, A. C., Ohno, Y., Powell, C. A., Prokop, M., et al. (2017) · Radiology · doi:10.1148/radiol.2017161659 · Cited by 2,491
Self-citationCallister, M. E. J., Baldwin, D. R., Akram, A. R., Barnard, S., Cane, P., Draffan, J., Franks, K., Gleeson, F., Graham, R., Malhotra, P., et al. (2015) · Thorax · doi:10.1136/thoraxjnl-2015-207168 · Cited by 958
Self-citationEuropean position statement on lung cancer screening
Oudkerk, M., Devaraj, A., Vliegenthart, R., Henzler, T., Prosch, H., Heussel, C. P., Bastarrika, G., Sverzellati, N., Mascalchi, M., Delorme, S., et al. (2017) · The Lancet Oncology · doi:10.1016/s1470-2045(17)30861-6 · Cited by 587
Computer-aided Diagnosis: How to Move from the Laboratory to the Clinic
van Ginneken, B., Schaefer-Prokop, C. M., & Prokop, M. (2011) · Radiology · doi:10.1148/radiol.11091710 · Cited by 306
Self-citationvan Ginneken, B., Armato, S. G., de Hoop, B., van Amelsvoort-van de Vorst, S., Duindam, T., Niemeijer, M., Murphy, K., Schilham, A., Retico, A., Fantacci, M. E., et al. (2010) · Medical Image Analysis · doi:10.1016/j.media.2010.05.005 · Cited by 298
Self-citation
Metadata
- Authors
- de Hoop, B., Gietema, H., van Ginneken, B., Zanen, P., Groenewegen, G., & Prokop, M.
- Venue
- European Radiology
- Published
- 2008-11-19
- Volume
- 19
- Issue
- 4
- Pages
- 800-808
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W2129866184
- Cited by
- 159
- References
- 10
- FWCI
- 6.12
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.