Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 346

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

CEM43°C thermal dose thresholds: a potential guide for magnetic resonance radiofrequency exposure levels?

Open access
van Rhoon, Gerard C., Samaras, Theodoros, Yarmolenko, Pavel S., Dewhirst, Mark W., Neufeld, Esra, Kuster, Niels · 2013 · European Radiology

Abstract

AbstractObjectiveTo define thresholds of safe local temperature increases for MR equipment that exposes patients to radiofrequency fields of high intensities for long duration. These MR systems induce heterogeneous energy absorption patterns inside the body and can create localised hotspots with a risk of overheating.MethodsThe MRI + EUREKA research consortium organised a “Thermal Workshop on RF Hotspots”. The available literature on thresholds for thermal damage and the validity of the thermal dose (TD) model were discussed.Results/ConclusionsThe following global TD threshold guidelines for safe use of MR are proposed:1.All persons: maximum local temperature of any tissue limited to 39 °C2.Persons with compromised thermoregulation AND(a)Uncontrolled conditions: maximum local temperature limited to 39 °C(b)Controlled conditions: TD < 2 CEM43°C3.Persons with uncompromised thermoregulation AND(a)Uncontrolled conditions: TD < 2 CEM43°C(b)Controlled conditions: TD < 9 CEM43°C The following definitions are applied:Controlled conditionsA medical doctor or a dedicated trained person can respond instantly to heat-induced physiological stressCompromised thermoregulationAll persons with impaired systemic or reduced local thermoregulationKey Points• Standard MRI can cause local heating by radiofrequency absorption. • Monitoring thermal dose (in units of CEM43°C) can control risk during MRI. • 9 CEM43°C seems an acceptable thermal dose threshold for most patients. • For skin, muscle, fat and bone,16 CEM43°C is likely acceptable.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00330-013-2825-y

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Cited by

See all 346

Metadata

Authors
van Rhoon, G. C., Samaras, T., Yarmolenko, P. S., Dewhirst, M. W., Neufeld, E., & Kuster, N.
Venue
European Radiology
Published
2013-04-04
Volume
23
Issue
8
Pages
2215-2227
ISSN
  • 0938-7994 (ISSN-L)
  • 1432-1084
OpenAlex
W1969496354
Cited by
346
References
29
FWCI
6.18
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: CEM43°C thermal dose thresholds: a potential guide for magnetic resonance radiofrequency exposure levels? https://app.cochat.ai/papers/10.1007/s00330-013-2825-y
The paper
van Rhoon, G. C., Samaras, T., Yarmolenko, P. S., Dewhirst, M. W., Neufeld, E., & Kuster, N. (2013). CEM43°C thermal dose thresholds: a potential guide for magnetic resonance radiofrequency exposure levels? European Radiology. https://doi.org/10.1007/s00330-013-2825-y

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.