CoChat

The reproducibility of closed-pouch sweat collection and thermoregulatory responses to exercise?heat stress

Hayden, Gavin, Milne, Helen C., Patterson, Mark J., Nimmo, Myra A. · 2004 · European Journal of Applied Physiology

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Seven active male subjects cycled for 60 min at 29.5 (0.8)% peak work rate on three separate occasions in a hot environmental condition [36.0 (0.1) degrees C, 60 (1)% relative humidity] in order to determine the reproducibility of a closed-pouch sweat collection technique for sweat composition at the scapula, forearm and thigh. To confirm that sweat composition was not influenced by between-trial variations in sudomotor drive, local sweat rate, whole-body sweat rate, heart rate (HR), rectal temperature (T(re)) and mean skin temperature (T(sk)) responses were also measured, consequently reproducibility was also established for these variables. Sweat composition did not differ among trials, with the mean coefficients of variation (CVs) for sweat [Na(+)], [K(+)] and pH being 10.4 (7.4)%, 8.1 (6.5)% and 1.3 (1.1)%, respectively. Local sweat rates did not differ among the three trials (P>0.05) although whole-body sweat rate was reduced in the third trial (P<0.05). The mean CVs were 11.0 (7.8)% and 4.7 (1.6)% for local and whole-body sweat rates, respectively. Between-trial differences were not evident for T(re), T(sk) or HR with mean CVs of 0.3 (0.2)%, 0.7 (0.6)% and 3.9 (1.7)%, respectively, although HR tended to be greater in the first trial ( P=0.08). It is proposed that moderate variations in sweat composition were influenced by variations in the local sweat rate, which were induced by application of the pouch.

Overview

Integrity signals

Registry

Crossref · 10.1007/s00421-004-1057-x

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 9 references

Cited by

See all 50

Metadata

Authors
Hayden, G., Milne, H. C., Patterson, M. J., & Nimmo, M. A.
Affiliations
University of Strathclyde (GB)
Corresponding author
Nimmo, Myra A.
Venue
European Journal of Applied Physiology
Published
2004-05-01
Volume
91
Issue
5-6
Pages
748-751
ISSN
  • 0020-9376 (ISSN-L)
  • 1439-6319
  • 1439-6327
OpenAlex
W2017349430
Cited by
42
References
9
Citations by year
2026: 3 · 2025: 1 · 2023: 2 · 2022: 2 · 2021: 4 · 2020: 3 · 2018: 4 · 2017: 3 · 2015: 3 · 2013: 3 · 2012: 1
FWCI
0.62
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • European Journal of Applied Physiology (publishedVersion)
  • PubMed (publishedVersion)
  • University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
Keywords
sweat composition, reproducibility, exercise in the heat, thermoregulation, local sweat rate, heart rate, skin temperature, rectal temperature, sodium, potassium, sweat pH
MeSH terms
Adult, Body Temperature, Hot Temperature, Homeostasis, Humans, Male, Sensitivity and Specificity, Skin Temperature, Specimen Handling, Sweat, Sweating, Reproducibility of Results, Exercise

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The reproducibility of closed-pouch sweat collection and thermoregulatory responses to exercise?heat stress. https://app.cochat.ai/papers/10.1007/s00421-004-1057-x
The paper
Hayden, G., Milne, H. C., Patterson, M. J., & Nimmo, M. A. (2004). The reproducibility of closed-pouch sweat collection and thermoregulatory responses to exercise?heat stress. European Journal of Applied Physiology. https://doi.org/10.1007/s00421-004-1057-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.