The reproducibility of closed-pouch sweat collection and thermoregulatory responses to exercise?heat stress
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Seven active male subjects cycled for 60 min at 29.5 (0.8)% peak work rate on three separate occasions in a hot environmental condition [36.0 (0.1) degrees C, 60 (1)% relative humidity] in order to determine the reproducibility of a closed-pouch sweat collection technique for sweat composition at the scapula, forearm and thigh. To confirm that sweat composition was not influenced by between-trial variations in sudomotor drive, local sweat rate, whole-body sweat rate, heart rate (HR), rectal temperature (T(re)) and mean skin temperature (T(sk)) responses were also measured, consequently reproducibility was also established for these variables. Sweat composition did not differ among trials, with the mean coefficients of variation (CVs) for sweat [Na(+)], [K(+)] and pH being 10.4 (7.4)%, 8.1 (6.5)% and 1.3 (1.1)%, respectively. Local sweat rates did not differ among the three trials (P>0.05) although whole-body sweat rate was reduced in the third trial (P<0.05). The mean CVs were 11.0 (7.8)% and 4.7 (1.6)% for local and whole-body sweat rates, respectively. Between-trial differences were not evident for T(re), T(sk) or HR with mean CVs of 0.3 (0.2)%, 0.7 (0.6)% and 3.9 (1.7)%, respectively, although HR tended to be greater in the first trial ( P=0.08). It is proposed that moderate variations in sweat composition were influenced by variations in the local sweat rate, which were induced by application of the pouch.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Even when testing conditions and sweat collection/analysis methodologies are standardized and well controlled, ~ 5 to 16% intra-individual day-to-day variability (CVs) in sweat [Na+] and [Cl−] is observed”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Hayden et al. 2004
Citations
Cites
Variations in Regional Sweat Composition in Normal Human Males
Patterson, M. J., Galloway, S. D. R., & Nimmo, M. A. (2000) · Experimental Physiology · doi:10.1111/j.1469-445x.2000.02058.x · Cited by 438 · cited 2×
“1991) has been validated against other local sweat collection (Boisvert and Candas 1994) and whole-body wash-down techniques (Patterson et al. 2000); however, the reproducibility of this technique has not yet been established.”
MethodSelf-citationShirreffs, S. M., & Maughan, R. J. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.1.336 · Cited by 251 · cited 1×
“Shirreffs and Maughan (1997) established the reproducibility of a whole-body wash-down technique for determination of sweat composition; however the reported coefficients of variation were high (15–23”
BackgroundInfluence of acclimatization on sweat sodium concentration.
Allan, J. R., & Wilson, C. G. (1971) · Journal of Applied Physiology · doi:10.1152/jappl.1971.30.5.708 · Cited by 171 · cited 2×
“This larger CV was possibly due to the considerable variation in sweat rate between trials, as it is well established that sweat rate changes will alter sweat [Na+] (Allan and Wilson 1971).”
BackgroundResponse of unacclimatized males to repeated weekly bouts of exercise in the heat.
Barnett, A., & Maughan, R. J. (1993) · British Journal of Sports Medicine · doi:10.1136/bjsm.27.1.39 · Cited by 71 · cited 3×
“This finding could imply a heat acclimation effect; however, no other physiological variables exhibited responses conducive to heat acclimation; similarly Barnett and Maughan (1993) reported no physiological refinements when exercise bouts were conducted on a weekly basis.”
BackgroundInfluentialEvidence for metaboreceptor stimulation of sweating in normothermic and heat‐stressed humans
Shibasaki, M., Kondo, N., & Crandall, C. G. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.00605.x · Cited by 67 · cited 2×
“If an exacerbated sympathetic nervous activity was evident in the first trial this may explain the reduced whole-body sweat rate between trials 1 and 3, considering the non-thermal drive for sweating has been linked to greater sympathetic nervous activity ( Shibasaki et al. 2001 ).”
BackgroundA simple and disposable sweat collector
Brisson, G. R., Boisvert, P., ronnet, F. P., Perrault, H., Boisvert, D., & Lafond, J. S. (1991) · European Journal of Applied Physiology · doi:10.1007/bf00233860 · Cited by 65 · cited 4×
“The determination of sweat composition using a closed-pouch sweat collector (Brisson et al. 1991) has been validated against other local sweat collection (Boisvert and Candas 1994) and whole-body wash-down techniques (Patterson et al.”
MethodInfluentialWILMORE, J. H., STANFORTH, P. R., TURLEY, K. R., GAGNON, J., DAW, E. W., LEON, A. S., RAO, D. C., SKINNER, J. S., & BOUCHARD, C. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199802000-00014 · Cited by 57 · cited 1×
“While this is the first investigation to ascertain the reliability of HR during exercise in a hot environment, the CV observed was similar to that reported in cooler conditions (Wilmore et al. 1998).”
ResultEffects of dietary sodium on body and muscle potassium content during heat acclimation
Armstrong, L. E., Costill, D. L., Fink, W. J., Bassett, D., Hargreaves, M., Nishibata, I., & King, D. S. (1985) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf02337183 · Cited by 57 · cited 2×
“Dietary Na intake has been reported to affect sweat [Na] during heat acclimation (Armstrong et al. 1985).”
BackgroundBoisvert, P., & Candas, V. (1994) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00609413 · Cited by 21 · cited 2×
“…of sweat composition using a closed-pouch sweat collector (Brisson et al. 1991) has been validated against other local sweat collection (Boisvert and Candas 1994) and whole-body wash-down techniques (Patterson et al. 2000); however, the reproducibility of this technique has not yet…”
Method
Cited by
Taylor, N. A., & Machado-Moreira, C. A. (2013) · Extreme Physiology & Medicine · doi:10.1186/2046-7648-2-4 · Cited by 490
“Readers need also to be aware that daily variations within individuals can approach 10% [255].”
BackgroundBaker, L. B. (2017) · Sports Medicine · doi:10.1007/s40279-017-0691-5 · Cited by 403
“absorbent patches [54] and approximately 8–12% for Parafilm-M pouches [134].”
BackgroundMethodPhysiological mechanisms determining eccrine sweat composition
Baker, L. B., & Wolfe, A. S. (2020) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04323-7 · Cited by 367
Bio-sensing textile based patch with integrated optical detection system for sweat monitoring
Morris, D., Coyle, S., Wu, Y., Lau, K. T., Wallace, G., & Diamond, D. (2009) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.02.032 · Cited by 235
Induction and decay of short-term heat acclimation
Garrett, A. T., Goosens, N. G., Rehrer, N. G., Patterson, M. J., & Cotter, J. D. (2009) · European Journal of Applied Physiology · doi:10.1007/s00421-009-1182-7 · Cited by 201
“Furthermore, the reliability studies in the present work indicated that no acclimation stimuli was reported for exercise fc, Tre and PV when post-acclimation, HSTs, took place 7 days apart and this is supported by previous research (Barnett and Maughan 1993; Pandolf 1998; Hayden et al. 2004).”
BackgroundResultInfluentialSelf-citationDissolution of materials in artificial skin surface film liquids
Stefaniak, A. B., & Harvey, C. J. (2006) · Toxicology in Vitro · doi:10.1016/j.tiv.2006.05.011 · Cited by 152
Sweat Mineral-Element Responses during 7 h of Exercise-Heat Stress
Montain, S. J., Cheuvront, S. N., & Lukaski, H. C. (2007) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.17.6.574 · Cited by 141
“2) to detect reductions in sweat mineral concentrations (9, 22) in excess of the anticipated within-subject coefficient of variation (11) (i.”
BackgroundMethodResultInfluentialCurto, V. F., Coyle, S. M., Byrne, R., Angelov, N., Diamond, D., & Benito‐Lopez, F. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.02.010 · Cited by 135
“Others sweat collection techniques involve the use of patches [4] and even a capsule configuration, made by a flexible adhesive membrane that is covered with an impermeable laboratory film paper, such as Parafilm”
MethodBaker, L. B., Ungaro, C. T., Sopeña, B. C., Nuccio, R. P., Reimel, A. J., Carter, J. M., Stofan, J. R., & Barnes, K. A. (2018) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00867.2017 · Cited by 116
“3% for RSR and REG sweat [Na ], respectively) were similar to the Parafilm-M closedpouch technique (20) and lower than the ventilated sweat capsule (22).”
BackgroundEffect of Heat Acclimation on Sweat Minerals
CHINEVERE, T. D., KENEFICK, R. W., CHEUVRONT, S. N., LUKASKI, H. C., & SAWKA, M. N. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181641c04 · Cited by 93
“In addition, eight subjects would provide sufficient power to detect a change in sweat sodium concentration equal to the typical day-today variability within subjects (~10%) (18).”
BackgroundMorris, C., Atkinson, G., Drust, B., Marrin, K., & Gregson, W. A. (2009) · Chronobiology International · doi:10.1080/07420520902885981 · Cited by 56
“…(i.e., .2 units) according to Borg’s (1982) 6–20-point category scale, and sweat loss (i.e., .0.3 kg) using within-subject standard deviations of 0.038C (Hayden et al., 2004), 2 beats . min21 (Garcin et al., 2003), 0.85 units (Bishop, 1997), and 0.07 kg (Schabort et al., 1998), respectively.”
InfluentialRepeatability of a running heat tolerance test
Mee, J. A., Doust, J., & Maxwell, N. (2015) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2015.02.010 · Cited by 55
“The CV of 0.3% and 1% for Trpeak and HRpeak respectively, compare favourably to the CV of 0.3% and 3.9% for mean Tr and mean HR reported during a 60 min, fixed intensity cycling protocol in hot humid conditions (Hayden et al., 2004).”
MethodInfluentialHarshman, S. W., Pitsch, R. L., Smith, Z. K., O’Connor, M. L., Geier, B. A., Qualley, A. V., Schaeublin, N. M., Fischer, M. V., Eckerle, J. J., Strang, A. J., et al. (2018) · PLOS ONE · doi:10.1371/journal.pone.0203133 · Cited by 51
Kenefick, R. W., Cheuvront, S. N., Elliott, L. D., Ely, B. R., & Sawka, M. N. (2012) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00456.2011 · Cited by 49
Marshall, H. C., Campbell, S. A., Roberts, C. W., & Nimmo, M. A. (2007) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2007.04.003 · Cited by 46
Self-citationSurface contamination artificially elevates initial sweat mineral concentrations
Ely, M. R., Kenefick, R. W., Cheuvront, S. N., Chinevere, T. D., Lacher, C. P., Lukaski, H. C., & Montain, S. J. (2011) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01437.2010 · Cited by 38
“Sweat samples were obtained using widely employed techniques (4, 9, 19), and mineral concentrations were measured using the most precise analytical technique available.”
Sweat sodium concentration during exercise in the heat in aerobically trained and untrained humans
Hamouti, N., Del Coso, J., Ortega, J. F., & Mora-Rodriguez, R. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-1911-6 · Cited by 36
Scalably Nanomanufactured Atomically Thin Materials‐Based Wearable Health Sensors
Zhang, R., Jiang, J. S., & Wu, W. (2021) · Small Structures · doi:10.1002/sstr.202100120 · Cited by 36
Rate normalization for sweat metabolomics biomarker discovery
Harshman, S. W., Strayer, K. E., Davidson, C. N., Pitsch, R. L., Narayanan, L., Scott, A. M., Schaeublin, N. M., Wiens, T. L., Phelps, M. S., O’Connor, M. L., et al. (2020) · Talanta · doi:10.1016/j.talanta.2020.121797 · Cited by 34
Measurement of sodium concentration in sweat samples: comparison of 5 analytical techniques
Goulet, E. D. B., Asselin, A., Gosselin, J., & Baker, L. B. (2017) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2017-0059 · Cited by 28
A Case-Series Observation of Sweat Rate Variability in Endurance-Trained Athletes
Smith, J. W., Bello, M. L., & Price, F. G. (2021) · Nutrients · doi:10.3390/nu13061807 · Cited by 25
“7% from the individuals’ average in those conditions) compared to previous research showing 5–7% variation [37,38].”
ResultMcDonald, P., Brown, H. A., Topham, T. H., Kelly, M. K., Jardine, W. T., Carr, A. J., Sawka, M. N., Woodward, A. P., Clark, B., & Périard, J. D. (2025) · Comprehensive physiology · doi:10.1002/cph4.70017 · Cited by 24
“Despite the 5%–7% day- to-day variability in individual WBSR (Baker et al. 2009; Hayden et al. 2004), several studies documented a lack of change in WBSR with exercise-HA (Shapiro et al. 1980; Pandolf et al. 1977; Roussey et al. 2021; Amano et al. 2015, 2016; Aoyagi et al. 1995a, 1998; Brock et al.…”
Relf, R., Willmott, A., Flint, M. S., Beale, L., & Maxwell, N. (2019) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2018.12.019 · Cited by 19
The Quantification of Body Fluid Allostasis During Exercise
Tam, N., & Noakes, T. D. (2013) · Sports Medicine · doi:10.1007/s40279-013-0089-y · Cited by 18
Willmott, A. G. B., Hayes, M., Dekerle, J., & Maxwell, N. (2015) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2015.08.008 · Cited by 20
The Effect of Heat Acclimation on Sweat Microminerals: Artifact of Surface Contamination
Ely, M. R., Kenefick, R. W., Cheuvront, S. N., Chinevere, T., Lacher, C. P., Lukaski, H. C., & Montain, S. J. (2013) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.23.5.470 · Cited by 16
“The denominator for the effect size estimate (i.e., SD) was set to 0.70 mmol/L (the between-subjects SD (Chinevere et al., 2008) and assumes that the within subjects SD would be smaller (Fraser, 2001; Hayden et al., 2004).”
BackgroundInfluentialThe effect of sweat sample storage condition on sweat content
Klous, L., Folkerts, M. A., Daanen, H. A. M., & Gerrett, N. (2021) · Temperature · doi:10.1080/23328940.2020.1867294 · Cited by 16
Relf, R. L., Eichhorn, G., Waldock, K., Flint, M. S., Beale, L., & Maxwell, N. (2020) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2020.102577 · Cited by 15
“Whilst reliability of a measurement is important in research designs, it cannot guarantee valid conclusions (Krippendorff, 2008), and therefore the occurrence of Type II errors (Hayden et al., 2004).”
BackgroundProgress in Personal Protective Equipment for Nanomaterials
Dolez, P. I. (2015) · Elsevier eBooks · doi:10.1016/b978-0-444-62747-6.00019-1 · Cited by 15
A new occupational heat tolerance test: A feasibility study
Watkins, E., Gibbons, J., Dellas, Y., Hayes, M., Watt, P., & Richardson, A. (2018) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2018.09.001 · Cited by 15
“(Hayden et al. 2004), 0.14 °C (0.4”
InfluentialReal-Time Sweat Analysis: Concept and Development of an Autonomous Wearable Micro-Fluidic Platform
Curto, V. F., Coyle, S. M., Byrne, R., Diamond, D., & Benito‐Lopez, F. (2011) · Procedia Engineering · doi:10.1016/j.proeng.2011.12.386 · Cited by 9
“Different sweat collection techniques have been employed over the years including whole body wash down technique [6], sweat collection patches [7] and a capsule inside a flexible adhesive membrane pasted onto the skin [8].”
MethodThe reliability of adolescent thermoregulatory responses during a heat acclimation protocol.
Brokenshire, C. S., Armstrong, N., & Williams, C. A. (2009) · Europe PMC (PubMed Central) · Cited by 8
The Impact of Nutritional Supplementation on Sweat Metabolomic Content: A Proof-of-Concept Study
Harshman, S. W., Browder, A. B., Davidson, C. N., Pitsch, R. L., Strayer, K. E., Schaeublin, N. M., Phelps, M. S., O’Connor, M. L., Mackowski, N. S., Barrett, K. N., et al. (2021) · Frontiers in Chemistry · doi:10.3389/fchem.2021.659583 · Cited by 7
Baker, L. B., Barnes, K. A., Sopeña, B. C., Nuccio, R. P., Reimel, A. J., & Ungaro, C. T. (2018) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.2017-0199 · Cited by 6
Reliability of a 60-min treadmill running protocol in the heat: The journal Temperature toolbox
Mündel, T., Gilmour, S. R., Kruger, M. C., & Thomson, J. S. (2022) · Temperature · doi:10.1080/23328940.2022.2143168 · Cited by 6
“[18] had participants cycle for 60 min at 30% peak work rate in 36°C and reported absolute variations of 0.”
Background‘My Sweat my Health’: Real Time Sweat Analysis Using Wearable Micro-fluidic Devices
Curto, V. F., Angelov, N., Coyle, S. M., Byrne, R. J., Hughes, S. M., Moyna, N. M., Diamond, D., & Benito‐Lopez, F. (2011) · International Conference on Pervasive Computing Technologies for Healthcare · doi:10.4108/icst.pervasivehealth.2011.246074 · Cited by 6
“Patterson et al. showed that inducing metabolic alkalosis through the ingestion of sodium bicarbonate led to increased blood and sweat pH [3].”
BackgroundDolez, P. I., Vinches, L., Perron, G., Vu‐Khanh, T., Plamondon, P., L’Éspérance, G., Wilkinson, K. J., Cloutier, Y., Dion, C., & Truchon, G. (2013) · PhareSST · doi:10.70010/xxto3021 · Cited by 6
“5 was measured for sweat during effort (Hayden et al., 2004).”
Dolez, P. I., Vinches, L., Perron, G., Vu‐Khanh, T., Plamondon, P., L’Éspérance, G., Wilkinson, K. J., Cloutier, Y., Dion, C., & Truchon, G. (2012) · PhareSST · doi:10.70010/otmt6454 · Cited by 5
McDONALD, P. J., John, K., Topham, T. H., Sawka, M. N., Clark, B., & Périard, J. D. (2026) · The Journal of Physiology · doi:10.1113/jp290089 · Cited by 3
“Indeed, the day-to-day variability in WBSR has been shown to range from 5% to 7% (Baker et al., 2009; Hayden et al., 2004).”
Freemas, J. A., Goss, C. S., Ables, R., Baker, T. B., Bruinvels, G., Mündel, T., Martin, B. J., Carter, S. J., Chapman, R. F., Khandpekar, O., et al. (2026) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00822.2025 · Cited by 2
Strategies to enhance performance in gaelic football players by reducing the risk of injuries
Newell, M. (2011) · Enlighten: Theses (The University of Glasgow) · Cited by 2
The effect of exercise on sodium balance in humans
Love, T. D. (2010) · OpenGrey (Institut de l'Information Scientifique et Technique) · Cited by 2
Fay, C. (2013) · Dublin City University Open Access Institutional Repository (Dublin City University) · Cited by 2
Ferrari, A., Ratel, S., Berthoin, S., Garnier, J.-P., & Baquet, G. (2026) · Frontiers in Physiology · doi:10.3389/fphys.2026.1809119 · Cited by 1
“Previous work using patch or closed-pouch collection has reported CVs of 8 – 16% for sweat [Na + ], indicating that the reproducibility of continuous measures is in a similar range and likely in fl uenced by the collection method (Baker et al., 2009; Hayden et al., 2004).”
Spontaneous self-draining droplet transport system on textile for moisture and thermal management
Chen, Y.-C., Weng, D.-H., & Liao, Y. (2023) · Journal of the Taiwan Institute of Chemical Engineers · doi:10.1016/j.jtice.2023.105317 · Cited by 1
Garrett, A. T., Rehrer, N. J., Patterson, M. J., Simpson, A., & Cotter, J. D. (2022) · Human performance in extreme environments · doi:10.7771/2327-2937.1140 · Cited by 1
“A comprehensive understanding of the variability and reproducibility of outcome measures is important for research design (Hayden et al., 2004) and to better understand confidence in the data generated.”
BackgroundResultInfluentialSelf-citationInduction and decay of heat acclimation
Garrett, A. T. (2007) · Otago University Research Archive (University of Otago) · Cited by 1
XiaoTian, H., Wook, Y., Zhang, S., & LiFang, J. (2026) · Frontiers in Physiology · doi:10.3389/fphys.2026.2002403
Physiological Aspects of Marathon Running, volume II
(2026) · Frontiers research topics · doi:10.3389/978-2-8325-8994-6
Metadata
- Authors
- Hayden, G., Milne, H. C., Patterson, M. J., & Nimmo, M. A.
- Affiliations
- University of Strathclyde (GB)
- Corresponding author
- Nimmo, Myra A.
- ORCID
- Nimmo, Myra A.
- Venue
- European Journal of Applied Physiology
- Published
- 2004-05-01
- Volume
- 91
- Issue
- 5-6
- Pages
- 748-751
- ISSN
- 0020-9376 (ISSN-L)
- 1439-6319
- 1439-6327
- OpenAlex
- W2017349430
- Cited by
- 42
- References
- 9
- Citations by year
- 2026: 3 · 2025: 1 · 2023: 2 · 2022: 2 · 2021: 4 · 2020: 3 · 2018: 4 · 2017: 3 · 2015: 3 · 2013: 3 · 2012: 1
- FWCI
- 0.62
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- European Journal of Applied Physiology (publishedVersion)
- PubMed (publishedVersion)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Keywords
- sweat composition, reproducibility, exercise in the heat, thermoregulation, local sweat rate, heart rate, skin temperature, rectal temperature, sodium, potassium, sweat pH
- MeSH terms
- Adult, Body Temperature, Hot Temperature, Homeostasis, Humans, Male, Sensitivity and Specificity, Skin Temperature, Specimen Handling, Sweat, Sweating, Reproducibility of Results, Exercise
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.