Validity of the Wescor's sweat conductivity analyzer for the assessment of sweat electrolyte concentrations

Boisvert, Paul, Candas, Victor · 1994 · European Journal of Applied Physiology and Occupational Physiology

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

The purpose of this study was to compare the "NaCl equivalent" values determined by the Wescor's sweat conductivity analyzer (Sweat-Chek) with the sweat Na+ and Cl- concentration values measured by conventional methods. The sweat was induced by 60-min exercise and collected by a closed-pouch collector. The "NaCl equivalent" values determined by the sweat conductivity analyzer (mean: 75 mmol.L-1, range: 38 - 122, n = 72) were significantly (P < 0.05) greater than Na+ concentration values (mean: 71 mmol.L-1, range: 24 - 123, n = 72) measured by flame photometry and Cl-concentration values (mean: 61 mmol.L-1, range: 18 - 100, n = 48) measured by coulometric titration. The difference were most accentuated for low concentration values. The 95% confidence-agreement intervals around the mean differences between methods were 11 mmol.L-1 (14%) for both Na+ and Cl-. The Sweat-Chek conductivity analyzer is a portable instrument which approximates the actual Na+ and Cl- concentrations in sweat but with a positive bias probably due to the other unmeasured anions present in sweat.

Overview

Integrity signals

Registry

Crossref · 10.1007/bf00609413

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 8 references

Research works printed but not linked: 1

  1. Hammond KB, Turcios NL, Gibson LE (1988) An evaluation of the Wescor Sweat-Chek Conductivity Analyzer. Pediat Pulm Suppl. 2: 139 (Abstract)

Cited by

See all 21

Metadata

Authors
Boisvert, P., & Candas, V.
Affiliations
Centre National de la Recherche Scientifique (FR)
Venue
European Journal of Applied Physiology and Occupational Physiology
Published
1994
Volume
69
Issue
2
Pages
176-178
ISSN
  • 0020-9376 (ISSN-L)
  • 0301-5548
  • 1439-6327
OpenAlex
W2009220371
Cited by
21
References
8
Citations by year
2026: 2 · 2021: 1 · 2020: 2 · 2019: 2 · 2018: 1 · 2017: 3 · 2015: 1 · 2014: 2 · 2012: 2
FWCI
0.00
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • European Journal of Applied Physiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
Keywords
sweat sodium, sweat chloride, measurement agreement, exercise-induced sweating, flame photometry, coulometric titration
MeSH terms
Chlorides, Electric Conductivity, Electrolytes, Humans, Male, Photometry, Sodium, Sweat, Exercise

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validity of the Wescor's sweat conductivity analyzer for the assessment of sweat electrolyte concentrations. https://app.cochat.ai/papers/10.1007/bf00609413
The paper
Boisvert, P., & Candas, V. (1994). Validity of the Wescor's sweat conductivity analyzer for the assessment of sweat electrolyte concentrations. European Journal of Applied Physiology and Occupational Physiology. https://doi.org/10.1007/bf00609413

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.