The detection and measurement of interleukin-6 in venous and capillary blood samples, and in sweat collected at rest and during exercise
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
Purpose This study aimed to quantify the relationship between venous and capillary blood sampling methods for the measurement of plasma interleukin-6 (IL-6). A parallel study was conducted to determine the possibility of measuring IL-6 in sweat using an enzyme-linked immunosorbent assay (ELISA) and investigate the relationship between plasma- and sweat-derived measures of IL-6.Methods Twelve male participants were recruited for the measurement of IL-6 at rest and during exercise (study 1). An additional group of five female participants was recruited for the measurement of IL-6 in venous blood versus sweat at rest and following exercise (study 2). In study 1, venous and capillary blood samples were collected at rest and in response to exercise. In study 2, venous and sweat samples were collected following exercise.Results Mean plasma IL-6 concentration was not different between venous and capillary blood sampling methods either at rest (4.27 ± 5.40 vs. 4.14 ± 4.45 pg ml(-1)), during (5.40 ± 5.17 vs. 5.58 ± 6.34 pg ml(-1)), or in response to exercise (6.95 ± 6.37 vs. 6.99 ± 6.74 pg ml(-1)). There was no IL-6 detectable in sweat either at rest or following exercise.Conclusion There are no differences in the measurement of plasma IL-6 using either venous or capillary blood sampling methods. Capillary measurement represents a minimally invasive way of measuring IL-6 and detecting changes in IL-6, which are linked to fatigue and overtraining.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“although IL-6 and TNF-α are not consistently detected (Dai et al. 2013; Faulkner et al. 2014).”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Faulkner et al. 2014
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Calculation of percentage changes in volumes of blood, plasma, and red cells in dehydration.
Dill, D. B., & Costill, D. L. (1974) · Journal of Applied Physiology · doi:10.1152/jappl.1974.37.2.247 · Cited by 3,384
Cytokines sing the blues: inflammation and the pathogenesis of depression
Raison, C. L., Capuron, L., & Miller, A. H. (2006) · Trends in Immunology · doi:10.1016/j.it.2005.11.006 · Cited by 3,009
Isaacson, P. G., Dogan, A., Price, S. K., & Spencer, J. (1989) · The American Journal of Surgical Pathology · doi:10.1097/00000478-198912000-00004 · Cited by 1,915
Pro‐ and anti‐inflammatory cytokine balance in strenuous exercise in humans
Ostrowski, K., Rohde, T., Asp, S., Schjerling, P., & Pedersen, B. K. (1999) · The Journal of Physiology · doi:10.1111/j.1469-7793.1999.287ad.x · Cited by 1,014
Muscle‐derived interleukin‐6: mechanisms for activation and possible biological roles
FEBBRAIO, M. A., & PEDERSEN, B. K. (2002) · The FASEB Journal · doi:10.1096/fj.01-0876rev · Cited by 875 · cited 1×
“In response to exercise, IL-6 undergoes the most dramatic increase of any cytokine, with the increase dependent on the duration and intensity of the exercise bout (Febbraio and Pedersen 2002; Fischer 2006), with high intensity exercise resulting in the most pronounced response (Leggate et al. 2010).”
BackgroundInterleukin-6 in acute exercise and training: what is the biological relevance?
Fischer, C. P. (2026) · PubMed · doi:10.22029/eir.2006.1620 · Cited by 825
Inflammatory Markers and Risk of Type 2 Diabetes
Wang, X., Bao, W., Liu, J., OuYang, Y.-Y., Wang, D., Rong, S., Xiao, X., Shan, Z.-L., Zhang, Y., Yao, P., et al. (2013) · Diabetes Care · doi:10.2337/dc12-0702 · Cited by 820
The major inflammatory mediator interleukin-6 and obesity
Eder, K., Baffy, N., Falus, A., & Fulop, A. K. (2009) · Inflammation Research · doi:10.1007/s00011-009-0060-4 · Cited by 433
Research works printed but not linked: 1
- Statistical Power Analysis for the Behavioural Sciences. J W Cohen, Lawrence Erlbaum AssociatesHillside, NJ2nd ed.Cohen JW., 1988. Statistical Power Analysis for the Behavioural Sciences. 2nd ed. Hillside, NJ: Lawrence Erlbaum Associates.
Cited by
Physiological mechanisms determining eccrine sweat composition
Baker, L. B., & Wolfe, A. S. (2020) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04323-7 · Cited by 367
Wearable sweat sensing for prolonged, semicontinuous, and nonobtrusive health monitoring
Moonen, E. J. M., Haakma, J. R., Peri, E., Pelssers, E., Mischi, M., & den Toonder, J. M. J. (2020) · VIEW · doi:10.1002/viw.20200077 · Cited by 86
Label-free electronic detection of interleukin-6 using horizontally aligned carbon nanotubes
Chen, H., Choo, T. K., Huang, J., Wang, Y., Liu, Y., Platt, M., Palaniappan, A., Liedberg, B., & Tok, A. I. Y. (2015) · Materials & Design · doi:10.1016/j.matdes.2015.11.029 · Cited by 61
Self-citationHighly manufacturable graphene oxide biosensor for sensitive Interleukin-6 detection
Huang, J., Chen, H., Niu, W., Fam, D. W. H., Palaniappan, A., Larisika, M., Faulkner, S. H., Nowak, C., Nimmo, M. A., Liedberg, B., et al. (2015) · RSC Advances · doi:10.1039/c5ra05854f · Cited by 50
Self-citationConformal and Disposable Antenna-Based Sensor for Non-Invasive Sweat Monitoring
Eldamak, A. R., & Fear, E. C. (2018) · Sensors · doi:10.3390/s18124088 · Cited by 51
Antiinflammatory Potential of Medicinal Plants: A Source for Therapeutic Secondary Metabolites
Bernstein, N., Akram, M., Daniyal, M., Koltai, H., Fridlender, M., & Gorelick, J. (2018) · Advances in agronomy · doi:10.1016/bs.agron.2018.02.003 · Cited by 56
Wolkow, A. P., Ferguson, S. A., Vincent, G. E., Larsen, B., Aisbett, B., & Main, L. C. (2015) · PLoS ONE · doi:10.1371/journal.pone.0138128 · Cited by 46
“However, recent evidence indicates a close correlation between venous and capillary plasma IL-6 responses during or post-exercise [39] and at rest [41].”
BackgroundWolkow, A., Aisbett, B., Reynolds, J., Ferguson, S. A., & Main, L. C. (2015) · Physiological Reports · doi:10.14814/phy2.12604 · Cited by 42
“However, recent evidence indicates a close correlation between venous and capillary plasma IL-6 responses at rest (Faulkner et al. 2014), as well as during and postexercise (Faulkner et al. 2014; Cullen et al. 2015).”
BackgroundResultWolkow, A. P., Aisbett, B., Reynolds, J., Ferguson, S. A., & Main, L. C. (2015) · International Archives of Occupational and Environmental Health · doi:10.1007/s00420-015-1085-3 · Cited by 38
Shiohara, T., Mizukawa, Y., Shimoda‐Komatsu, Y., & Aoyama, Y. (2018) · Allergology International · doi:10.1016/j.alit.2018.07.010 · Cited by 32
Automated in Vivo Nanosensing of Breath-Borne Protein Biomarkers
Chen, H., Li, J., Zhang, X., Li, X., Yao, M., & Zheng, G. (2018) · Nano Letters · doi:10.1021/acs.nanolett.8b01070 · Cited by 29
Distance-Based All-In-One Immunodevice for Point-of-Care Monitoring of Cytokine Interleukin‑6
Khachornsakkul, K., Dungchai, W., & Pamme, N. (2022) · ACS Sensors · doi:10.1021/acssensors.2c01122 · Cited by 29
Shimoda‐Komatsu, Y., Sato, Y., Yamazaki, Y., Takahashi, R., & Shiohara, T. (2017) · Experimental Dermatology · doi:10.1111/exd.13448 · Cited by 30
Glucose Counter-regulation After Acute Pancreatitis
Bharmal, S. H., Pendharkar, S. A., Singh, R. G., Cho, J., & Petrov, M. S. (2019) · Pancreas · doi:10.1097/mpa.0000000000001318 · Cited by 20
Coplanar Waveguide Based Sensor Using Paper Superstrate for Non-Invasive Sweat Monitoring
Riad, M. M. Y. R., & Eldamak, A. R. (2020) · IEEE Access · doi:10.1109/access.2020.3027033 · Cited by 18
“Human sweat is mainly composed of sodium, chloride, potassium, magnesium, zinc, iron, calcium, copper phosphate, uric acid, urea, lactic acid as well as amino acids [10].”
BackgroundWearable Sweat Management Technologies
Wei, L., Li, Z., Dai, Z., Ding, L., Wei, H., Li, J., Zhu, H., & Zhu, Y. (2024) · Advanced Materials Technologies · doi:10.1002/admt.202301812 · Cited by 21
Reichel, T., Held, S., Schwarz, A., Hacker, S., Wesemann, F., Donath, L., & Krüger, K. (2022) · European Journal of Applied Physiology · doi:10.1007/s00421-022-05068-1 · Cited by 15
“Many athletes are familiar with blood sampling from the earlobe, as this is also where lactate measurements are taken (Faulkner et al. 2014; Martinez-Navarro et al. 2021).”
BackgroundAncient roots – Modern applications: Mindfulness as a novel intervention for cardiovascular disease
Zieff, G. H. (2017) · Medical Hypotheses · doi:10.1016/j.mehy.2017.08.001 · Cited by 18
Matas, M., Tokmadžić, V. S., Kozmar, A., Likić, R., & Sekulić, A. (2019) · Medicine · doi:10.1097/md.0000000000017450 · Cited by 9
“1.([17,18]) We determined that a minimum of 20 participants was required per group for pair-wise comparisons of our samples.”
BackgroundGarcía‐Cruz, Á., Nessark, F., Lee, M., Zine, N., Sigaud, M., Pruna, R., Lopez, M., Marote, P., Bausells, J., Jaffrezic-Renault, N. J., et al. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.09.057 · Cited by 9
Improved synthesis and growth of graphene oxide for field effect transistor biosensors
Huang, J., Chen, H., Jing, L., Fam, D. W. H., & Tok, A. I. Y. (2016) · Biomedical Microdevices · doi:10.1007/s10544-016-0092-9 · Cited by 8
Self-citationStein, D. F., O’Connor, D., Blohmke, C. J., Sadarangani, M., & Pollard, A. J. (2016) · Vaccine · doi:10.1016/j.vaccine.2016.09.007 · Cited by 11
Mapping Multi-Modal Fatigue in Elite Soccer Through Sweat-Omics Perspectives: A Narrative Review
Gnanasigamani, M., Arslan, E., Soylu, Y., Kilit, B., & Chmura, P. (2025) · Biology · doi:10.3390/biology14081069 · Cited by 11
“Inflammatory cytokines such as IL-6 remain largely undetectable post-exercise in sweat across several studies [66], calling into question their suitability as fatigue indices under current assay limitations.”
Kistner, T. M., Tavormina, A., & Lieberman, D. E. (2024) · American Journal of Human Biology · doi:10.1002/ajhb.24131 · Cited by 8
“…we are confident that IL-6 concentrations in capillary blood reflect true exercise-dependent increases because there is a high correlation ( r >0.9) in the direction and magnitude of IL-6 changes derived from capillary samples and venous samples (Cullen et al., 2015; Faulkner et al., 2014).”
InfluentialMizukawa, Y., Yamazaki, Y., & Shiohara, T. (2018) · Archives of Dermatological Research · doi:10.1007/s00403-018-1882-0 · Cited by 6
Complete coverage of reduced graphene oxide on silicon dioxide substrates
Huang, J., Larisika, M., Chen, H., Faulkner, S. H., Nimmo, M. A., Nowak, C., & Tok, A. I. Y. (2014) · Chinese Physics B · doi:10.1088/1674-1056/23/8/088104 · Cited by 5
“Eventually, this RGO growth can be used to manufacture biosensor transducers for the study of important molecules such as Interleukin6[18].”
BackgroundSelf-citationBates‐Fraser, L. C., Moertl, K. M., Stopforth, C. K., Bartlett, D. B., Ondrak, K. S., Jensen, B. C., & Hanson, E. D. (2024) · Advanced Exercise and Health Science · doi:10.1016/j.aehs.2024.01.002 · Cited by 7
The Role of Sweat in the Pathogenesis of Atopic Dermatitis
Shiohara, T., Shimoda‐Komatsu, Y., Mizukawa, Y., Hayashida, Y., & Aoyama, Y. (2017) · Springer eBooks · doi:10.1007/978-981-10-5541-6_11 · Cited by 5
Hu, Y., Zhou, X., & Yang, Z. (2026) · Microchemical Journal · doi:10.1016/j.microc.2026.117414 · Cited by 2
Growth of Reduced Graphene Oxide
Huang, J., Chen, H., Fam, D. W. H., Faulkner, S. H., Niu, W., Larisika, M., Nowak, C., Nimmo, M. A., & Tok, A. I. Y. (2014) · MRS Proceedings · doi:10.1557/opl.2014.854 · Cited by 2
“The complete coverage of RGO on the substrate decreased the standard deviation of between measurement sites significantly, thus solving a critical problem for the practical use of RGO in electronics such as the development of biosensors[18-20] and microelectronics[14, 21].”
BackgroundSelf-citationComparison of biochemical parameters of the blood: fingerstick versus venous sampling
Olkhovik, A. Y., Сергеевич, С. П., Vasiliev, A., Denisov, D. G., & Emanuel, V. L. (2018) · Laboratory Service · doi:10.17116/labs2018725-11 · Cited by 1
Tapering strategies for elite endurance running performance
Spilsbury, K. L. (2016) · Loughborough University Institutional Repository (Loughborough University) · Cited by 1
Self-citationUltra-sensitive carbon based molecular sensors
Huang, J. (2014) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/62923
Self-citationShiohara, T., & Mizukawa, Y. (2018) · Journal of Cutaneous Immunology and Allergy · doi:10.1002/cia2.12026
Microstrip Sensors for Biomedical Engineering
Elsheakh, D. N., & Eldamak, A. R. (2024) · Springer eBooks · doi:10.1007/978-3-031-39824-7_18
Laborie, E. (2021) · theses.fr (ABES) · doi:10.70675/b6bfae86zb344z4e7bz8581z483b70c63f21 · Cited by 1
Metadata
- Authors
- Faulkner, S. H., Spilsbury, K. L., Harvey, J., Jackson, A., Huang, J., Platt, M., Tok, A., & Nimmo, M. A.
- Affiliations
- Loughborough University (GB)
- Nanyang Technological University (SG)
- Corresponding author
- Nimmo, Myra A.
- Venue
- European Journal of Applied Physiology
- Published
- 2014-03-01
- Volume
- 114
- Issue
- 6
- Pages
- 1207-1216
- ISSN
- 0020-9376 (ISSN-L)
- 1439-6319
- 1439-6327
- OpenAlex
- W2073487527
- Cited by
- 37
- References
- 46
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 4 · 2022: 2 · 2021: 1 · 2020: 3 · 2019: 2 · 2018: 7 · 2017: 4 · 2016: 3 · 2015: 6 · 2014: 3
- FWCI
- 5.16
- Type
- journal article
- Language
- en
- Open access
- green
- dspace.lboro.ac.uk
- Licence
- cc-by-nc-nd
- www.springer.com/tdm (tdm)
- Locations
- European Journal of Applied Physiology (publishedVersion)
- PubMed (publishedVersion)
- Loughborough University Institutional Repository (Loughborough University) (submittedVersion, cc-by-nc-nd)
- Loughborough University Research Repository (Loughborough University) (submittedVersion, cc-by-nc-nd)
- Nottingham Trent University's Institutional Repository (Nottingham Trent Repository) (submittedVersion)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Exercise and Physiological Responses
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Keywords
- interleukin-6, capillary blood sampling, venous blood sampling, sweat, physical activity, plasma cytokines, minimally invasive sampling, fatigue, overtraining
- MeSH terms
- Adult, Blood Chemical Analysis, Blood Specimen Collection, Capillaries, Female, Humans, Male, Rest, Sweat, Veins, Exercise, Interleukin-6
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.