CoChat

The detection and measurement of interleukin-6 in venous and capillary blood samples, and in sweat collected at rest and during exercise

Open access
Faulkner, Steve H., Spilsbury, Kate L., Harvey, James, Jackson, Andrew, Huang, Jingfeng, Platt, Mark, Tok, Alfred, Nimmo, Myra A. · 2014 · European Journal of Applied Physiology

The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.

Abstract

Purpose This study aimed to quantify the relationship between venous and capillary blood sampling methods for the measurement of plasma interleukin-6 (IL-6). A parallel study was conducted to determine the possibility of measuring IL-6 in sweat using an enzyme-linked immunosorbent assay (ELISA) and investigate the relationship between plasma- and sweat-derived measures of IL-6.Methods Twelve male participants were recruited for the measurement of IL-6 at rest and during exercise (study 1). An additional group of five female participants was recruited for the measurement of IL-6 in venous blood versus sweat at rest and following exercise (study 2). In study 1, venous and capillary blood samples were collected at rest and in response to exercise. In study 2, venous and sweat samples were collected following exercise.Results Mean plasma IL-6 concentration was not different between venous and capillary blood sampling methods either at rest (4.27 ± 5.40 vs. 4.14 ± 4.45 pg ml(-1)), during (5.40 ± 5.17 vs. 5.58 ± 6.34 pg ml(-1)), or in response to exercise (6.95 ± 6.37 vs. 6.99 ± 6.74 pg ml(-1)). There was no IL-6 detectable in sweat either at rest or following exercise.Conclusion There are no differences in the measurement of plasma IL-6 using either venous or capillary blood sampling methods. Capillary measurement represents a minimally invasive way of measuring IL-6 and detecting changes in IL-6, which are linked to fatigue and overtraining.

Overview

Integrity signals

Registry

Crossref · 10.1007/s00421-014-2851-8

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 1

  1. Cohen JW (1988) Statistical power analysis for the behavioural sciences, 2nd edn. Lawrence Erlbaum Associates, Hillside, NJ

Cited by

See all 37

Metadata

Authors
Faulkner, S. H., Spilsbury, K. L., Harvey, J., Jackson, A., Huang, J., Platt, M., Tok, A., & Nimmo, M. A.
Affiliations
  • Loughborough University (GB)
  • Nanyang Technological University (SG)
Corresponding author
Nimmo, Myra A.
Venue
European Journal of Applied Physiology
Published
2014-03-01
Volume
114
Issue
6
Pages
1207-1216
ISSN
  • 0020-9376 (ISSN-L)
  • 1439-6319
  • 1439-6327
OpenAlex
W2073487527
Cited by
37
References
46
Citations by year
2026: 1 · 2025: 1 · 2024: 4 · 2022: 2 · 2021: 1 · 2020: 3 · 2019: 2 · 2018: 7 · 2017: 4 · 2016: 3 · 2015: 6 · 2014: 3
FWCI
5.16
Type
journal article
Language
en
Open access
Licence
  • cc-by-nc-nd
  • www.springer.com/tdm (tdm)
Locations
  • European Journal of Applied Physiology (publishedVersion)
  • PubMed (publishedVersion)
  • Loughborough University Institutional Repository (Loughborough University) (submittedVersion, cc-by-nc-nd)
  • Loughborough University Research Repository (Loughborough University) (submittedVersion, cc-by-nc-nd)
  • Nottingham Trent University's Institutional Repository (Nottingham Trent Repository) (submittedVersion)
  • University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Exercise and Physiological Responses
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
Keywords
interleukin-6, capillary blood sampling, venous blood sampling, sweat, physical activity, plasma cytokines, minimally invasive sampling, fatigue, overtraining
MeSH terms
Adult, Blood Chemical Analysis, Blood Specimen Collection, Capillaries, Female, Humans, Male, Rest, Sweat, Veins, Exercise, Interleukin-6

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.