CoChat

Laparoscopic evaluation of intestinal ischemia using fluorescein and ultraviolet light in a porcine model

McGinty, J. J., Hogle, N., Fowler, D. L · 2003 · Surgical Endoscopy And Other Interventional Techniques

The DOI matches its Crossref record; 20 of the 21 references it cites were found in a registry or an index.

Abstract

Background The laparoscopic use of fluorescein and ultraviolet light may be a useful diagnostic tool that potentially could reduce the time until diagnosis and the subsequent mortality of mesenteric ischemia.Methods Eight pigs were subjected to a pneumoperitoneum pressure of 7 mmHg, and another eight pigs were exposed to a pressure of 14 mmHg. A segment of small bowel was devascularized. Two filters were used to create ultraviolet light. Pigs from each pressure group were given various intravenous fluorescein doses. The ischemic segment of the small intestine and other structures were inspected laparoscopically with the filters attached. A videotape was evaluated by resident and attending surgeons.Results Ischemic bowel was seen as a darkened silhouette against the viable fluorescent tissue. Overall, the results show that the use of ultraviolet light and fluorescence in the laparoscopic model is adequate for allowing the identification of ischemic bowel.Conclusions The laparoscopic use of ultraviolet light combined with intravenous fluorescein dye is an effective diagnostic tool for evaluating mesenteric ischemia in pigs.

Overview

Integrity signals

Registry

Crossref · 10.1007/s00464-001-8255-y

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 20 references

Research works printed but not linked: 6

  1. J Ballard, 1993, Am Surg, 59, 309
  2. T Iberti, 1989, Surgery, 105, 686
  3. R Kaleya, 1992, Can J Surg, 35, 613
  4. A Mann, 1982, Surg Gynecol Obstet, 154, 53
  5. E Paes, 1988, Chirurg, 59, 828
  6. J Windsor, 1997, Surg Laparosc Endosc, 7, 480, 10.1097/00019509-199712000-00010 · doi:10.1097/00019509-199712000-00010

Cited by

See all 19

Metadata

Authors
McGinty, J. J., Hogle, N., & Fowler, D. L.
Affiliations
  • Allegheny Health Network (US)
  • NewYork–Presbyterian Hospital (US)
Venue
Surgical Endoscopy And Other Interventional Techniques
Published
2003-04-28
Volume
17
Issue
7
Pages
1140-1143
ISSN
  • 0930-2794 (ISSN-L)
  • 1432-2218
OpenAlex
W2092517474
Cited by
18
References
21
Citations by year
2025: 2 · 2022: 2 · 2020: 2 · 2016: 1 · 2015: 1 · 2014: 1 · 2012: 1
FWCI
0.34
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Surgical Endoscopy (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Abdominal vascular conditions and treatments
  • Health Sciences › Medicine › Gastroenterology › Gastrointestinal Bleeding Diagnosis and Treatment
  • Health Sciences › Medicine › Emergency Medicine › Appendicitis Diagnosis and Management
Keywords
mesenteric ischemia, intestinal ischemia, diagnostic laparoscopy, fluorescein, ultraviolet radiation, porcine model, pneumoperitoneum, fluorescence imaging
MeSH terms
Animals, Disease Models, Animal, Intestines, Ischemia, Laparoscopy, Swine, Ultraviolet Rays, Fluorescein

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Laparoscopic evaluation of intestinal ischemia using fluorescein and ultraviolet light in a porcine model. https://app.cochat.ai/papers/10.1007/s00464-001-8255-y
The paper
McGinty, J. J., Hogle, N., & Fowler, D. L. (2003). Laparoscopic evaluation of intestinal ischemia using fluorescein and ultraviolet light in a porcine model. Surgical Endoscopy And Other Interventional Techniques. https://doi.org/10.1007/s00464-001-8255-y

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.