External tissue support and fluid–structure simulation in blood flows
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yushkevich, P. A., Piven, J., Hazlett, H. C., Smith, R. G., Ho, S., Gee, J. C., & Gerig, G. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.015 · Cited by 8,868 · cited 1×
“Figure 2 depicts the methodology used to generate a computer model of the thoracic aorta: starting with the phase of the cardiac-gated CT data corresponding to diastole, a 3D segmentation is performed using a level-set method (Yushkevich et al. 2006; Xiong et al. 2010).”
MethodBiomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
Fung, Y.-C. (1993) · Springer eBooks · doi:10.1007/978-1-4757-2257-4 · Cited by 2,051
Chen, C.-H., Nevo, E., Fetics, B., Pak, P. H., Yin, F. C. P., Maughan, W. L., & Kass, D. A. (1997) · Circulation · doi:10.1161/01.cir.95.7.1827 · Cited by 1,307 · cited 1×
“Transfer functions can be utilized to extrapolate these peripheral measurements to central aortic pressure values (Chen et al. 1997).”
BackgroundFinite element modeling of blood flow in arteries
Taylor, C. A., Hughes, T. J. R., & Zarins, C. K. (1998) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/s0045-7825(98)80008-x · Cited by 726 · cited 1×
“The coupled momentum method is based on a stabilized finite element formulation (Taylor et al. 1998; Whiting and Jansen 2001) of the equations for an incompressible Newtonian fluid discretized on a fixed computational grid.”
MethodSelf-citationVignon-Clementel, I. E., Alberto Figueroa, C., Jansen, K. E., & Taylor, C. A. (2006) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2005.04.014 · Cited by 646 · cited 1×
“This study was further extended in Formaggia et al. (2007) and similar ideas can be found in Vignon-Clementel et al. (2006), Blanco et al. (2007), Blanco et al. (2009), and Papadakis (2009) using onedimensional or ordinary differential equations models for the downstream flows.”
ResultSelf-citationReview Paper: Continuum biomechanics of soft biological tissues
Humphrey, J. D. (2003) · Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.2002.1060 · Cited by 620 · cited 2×
“…constitutive laws developed for arterial walls—for example with exponential terms and anisotropic strain energy functions, see e.g. Fung (1993), Humphrey (2003), Holzapfel (2006) and references therein—but we found the above choice to give satisfactory results in the range of deformations…”
BackgroundA coupled momentum method for modeling blood flow in three-dimensional deformable arteries
Figueroa, C. A., Vignon-Clementel, I. E., Jansen, K. E., Hughes, T. J. R., & Taylor, C. A. (2006) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2005.11.011 · Cited by 547 · cited 3×
“Considering the wall to be a thin membrane of given thickness h, we define the vessel wall problem in the domain s = × h and we use the linear elastic model presented in Figueroa et al. (2006). This leads to a membrane stress tensor σ m in which the twice-normal component is assumed to vanish.”
MethodInfluentialSelf-citationPatient-Specific Modeling of Cardiovascular Mechanics
Taylor, C. A., & Figueroa, C. A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160521 · Cited by 451 · cited 2×
“Unlike other medical imaging modalities such as Doppler ultrasound and phase-contrast magnetic resonance imaging (PCMRI) that enable non-invasive measurement of blood flow (Taylor and Figueroa 2009), CT data do not provide velocity information.”
BackgroundSelf-citationHolzapfel, G. A. (2005) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2005.05.006 · Cited by 394 · cited 1×
“…laws developed for arterial walls—for example with exponential terms and anisotropic strain energy functions, see e.g. Fung (1993), Humphrey (2003), Holzapfel (2006) and references therein—but we found the above choice to give satisfactory results in the range of deformations considered with…”
Background
Cited by
Mechanics, mechanobiology, and modeling of human abdominal aorta and aneurysms
Humphrey, J. D., & Holzapfel, G. A. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.11.021 · Cited by 307
Quarteroni, A., Lassila, T., Rossi, S., & Ruiz-Baier, R. (2017) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2016.05.031 · Cited by 248
“by Robintype boundary conditions [100] can be tuned to mimic the global motion of the heart, but does not permit sliding contact between the heart and the pericardium.”
BackgroundThe cardiovascular system: Mathematical modelling, numerical algorithms and clinical applications
Quarteroni, A., Manzoni, A., & Vergara, C. (2017) · Acta Numerica · doi:10.1017/s0962492917000046 · Cited by 232
“To account for the effect of the tissues surrounding the artery, the algebraic law (1) is often prescribed at the external lateral surface Γext of Ωs, to mimic the elastic behavior of this tissue [380].”
BackgroundMethodInfluentialGeometric multiscale modeling of the cardiovascular system, between theory and practice
Quarteroni, A., Veneziani, A., & Vergara, C. (2016) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2016.01.007 · Cited by 204
“In [126], an algebraic law is proposed to mimic an elastic behavior of this tissue.”
BackgroundComputational Simulations for Aortic Coarctation: Representative Results From a Sampling of Patients
LaDisa, J. F., Alberto Figueroa, C., Vignon-Clementel, I. E., Jin Kim, H., Xiao, N., Ellwein, L. M., Chan, F. P., Feinstein, J. A., & Taylor, C. A. (2011) · Journal of Biomechanical Engineering · doi:10.1115/1.4004996 · Cited by 159
Self-citationAlimohammadi, M., Sherwood, J. M., Karimpour, M., Agu, O., Balabani, S., & Díaz-Zuccarini, V. (2015) · BioMedical Engineering OnLine · doi:10.1186/s12938-015-0032-6 · Cited by 158
“There is a growing amount of literature on FSI simulations of aortae [16,17,27-29], using various models for the structure of the vessel wall [30,31] in order to capture the”
MethodNguyen, T. D., Kadri, O. E., & Voronov, R. S. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.529365 · Cited by 19
Metadata
- Authors
- Moireau, P., Xiao, N., Astorino, M., Figueroa, C. A., Chapelle, D., Taylor, C. A., & Gerbeau, J.-F.
- Venue
- Biomechanics and Modeling in Mechanobiology
- Published
- 2011-02-10
- Volume
- 11
- Issue
- 1-2
- Pages
- 1-18
- ISSN
- 1617-7940 (ISSN-L)
- 1617-7959
- OpenAlex
- W2007466958
- Cited by
- 244
- References
- 26
- FWCI
- 12.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.