The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Transport in two-dimensional paper networks
Open accessAbstract
Two-dimensional paper networks (2DPNs) hold great potential for transcending the capabilities and performance of today’s paper-based analytical devices. Specifically, 2DPNs enable sophisticated multi-step chemical processing sequences for sample pretreatment and analysis at a cost and ease-of-use that make them appropriate for use in settings with low resources. A quantitative understanding of flow in paper networks is essential to realize the potential of these networks. In this report, we provide a framework for understanding flow in simple 2DPNs using experiments, analytical expressions, and computational simulations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Dynamics of Capillary Flow
Washburn, E. W. (1921) · Physical Review · doi:10.1103/physrev.17.273 · Cited by 7,141
Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable Bioassays
Martinez, A. W., Phillips, S. T., Butte, M. J., & Whitesides, G. M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200603817 · Cited by 2,874
Diagnostics for the Developing World: Microfluidic Paper-Based Analytical Devices
Martinez, A. W., Phillips, S. T., Whitesides, G. M., & Carrilho, E. (2010) · Analytical Chemistry · doi:10.1021/ac9013989 · Cited by 2,674
Three-dimensional microfluidic devices fabricated in layered paper and tape
Martinez, A. W., Phillips, S. T., & Whitesides, G. M. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0810903105 · Cited by 1,246
ImageJ, U.S. National Institutes of Health, Bethesda, Maryland, USA
Rasband, W. S. (2011) · Medical Entomology and Zoology · Cited by 1,221
FLASH: A rapid method for prototyping paper-based microfluidic devices
Martinez, A. W., Phillips, S. T., Wiley, B. J., Gupta, M., & Whitesides, G. M. (2008) · Lab on a Chip · doi:10.1039/b811135a · Cited by 695
The permeability of fibrous porous media
Jackson, G. W., & James, D. F. (1986) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.5450640302 · Cited by 646
Controlled reagent transport in disposable 2D paper networks
Fu, E., Lutz, B., Kauffman, P., & Yager, P. (2010) · Lab on a Chip · doi:10.1039/b919614e · Cited by 363
Self-citationAlava, M., & Niskanen, K. (2006) · Reports on Progress in Physics · doi:10.1088/0034-4885/69/3/r03 · Cited by 361
(2008) · Lab on a Chip · doi:10.1039/b814043j · Cited by 235
Imbibition in Porous Membranes of Complex Shape: Quasi-stationary Flow in Thin Rectangular Segments
Mendez, S., Fenton, E. M., Gallegos, G. R., Petsev, D. N., Sibbett, S. S., Stone, H. A., Zhang, Y., & López, G. P. (2010) · Langmuir · doi:10.1021/la902470b · Cited by 187
Lewis, H. B. (1952) · American Journal of Clinical Pathology · doi:10.1093/ajcp/22.1.63a · Cited by 144
Cited by
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 1,943
Recent Developments in Paper-Based Microfluidic Devices
Cate, D. M., Adkins, J. A., Mettakoonpitak, J., & Henry, C. S. (2015) · Analytical Chemistry · doi:10.1021/ac503968p · Cited by 1,236
Commercialization of microfluidic point-of-care diagnostic devices
Chin, C. D., Linder, V., & Sia, S. K. (2012) · Lab on a Chip · doi:10.1039/c2lc21204h · Cited by 1,124
Advances in paper-based point-of-care diagnostics
Hu, J., Wang, S., Wang, L., Li, F., Pingguan-Murphy, B., Lu, T. J., & Xu, F. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.10.075 · Cited by 956
A perspective on paper-based microfluidics: Current status and future trends
Li, X., Ballerini, D. R., & Shen, W. (2012) · Biomicrofluidics · doi:10.1063/1.3687398 · Cited by 813
Metadata
- Authors
- Fu, E., Ramsey, S. A., Kauffman, P., Lutz, B., & Yager, P.
- Venue
- Microfluidics and Nanofluidics
- Published
- 2010-06-23
- Volume
- 10
- Issue
- 1
- Pages
- 29-35
- ISSN
- 1613-4982 (ISSN-L)
- 1613-4990
- OpenAlex
- W2160470359
- Cited by
- 313
- References
- 12
- FWCI
- 11.10
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.