Endothelial Glycocalyx: Permeability Barrier and Mechanosensor
Open accessThe DOI matches its Crossref record; 81 of the 81 references it cites were found in a registry or an index.
Abstract
Endothelial cells are covered with a polysaccharide rich layer more than 400 nm thick, mechanical properties of which limit access of circulating plasma components to endothelial cell membranes. The barrier properties of this endothelial surface layer are deduced from the rate of tracer penetration into the layer and the mechanics of red and white cell movement through capillary microvessels. This review compares the mechanosensor and permeability properties of an inner layer (100–150 nm, close to the endothelial membrane) characterized as a quasi-periodic structure which accounts for key aspects of transvascular exchange and vascular permeability with those of the whole endothelial surface layers. We conclude that many of the barrier properties of the whole surface layer are not representative of the primary fiber matrix forming the molecular filter determining transvascular exchange. The differences between the properties of the whole layer and the inner glycocalyx structures likely reflect dynamic aspects of the endothelial surface layer including tracer binding to specific components, synthesis and degradation of key components, activation of signaling pathways in the endothelial cells when components of the surface layer are lost or degraded, and the spatial distribution of adhesion proteins in microdomains of the endothelial cell membrane.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The endothelial glycocalyx: composition, functions, and visualization
Reitsma, S., Slaaf, D. W., Vink, H., van Zandvoort, M. A. M. J., & oude Egbrink, M. G. A. (2007) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-007-0212-8 · Cited by 1,980
Laurent, T. C., & Fraser, J. R. E. (1992) · The FASEB Journal · doi:10.1096/fasebj.6.7.1563592 · Cited by 1,880
A mechanosensory complex that mediates the endothelial cell response to fluid shear stress
Tzima, E., Irani-Tehrani, M., Kiosses, W. B., Dejana, E., Schultz, D. A., Engelhardt, B., Cao, G., DeLisser, H., & Schwartz, M. A. (2005) · Nature · doi:10.1038/nature03952 · Cited by 1,711
The Structure and Function of the Endothelial Glycocalyx Layer
Weinbaum, S., Tarbell, J. M., & Damiano, E. R. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151959 · Cited by 1,198
Microvascular fluid exchange and the revised Starling principle
Levick, J. R., & Michel, C. C. (2010) · Cardiovascular Research · doi:10.1093/cvr/cvq062 · Cited by 1,183
The spaces in a uniform random suspension of fibres
Ogston, A. G. (1958) · Transactions of the Faraday Society · doi:10.1039/tf9585401754 · Cited by 1,058
Michel, C. C., & Curry, F. E. (1999) · Physiological Reviews · doi:10.1152/physrev.1999.79.3.703 · Cited by 811
Self-citationRehm, M., Bruegger, D., Christ, F., Conzen, P., Thiel, M., Jacob, M., Chappell, D., Stoeckelhuber, M., Welsch, U., Reichart, B., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.684852 · Cited by 669
Nieuwdorp, M., van Haeften, T. W., Gouverneur, M. C. L. G., Mooij, H. L., van Lieshout, M. H. P., Levi, M., Meijers, J. C. M., Holleman, F., Hoekstra, J. B. L., Vink, H., et al. (2006) · Diabetes · doi:10.2337/diabetes.55.02.06.db05-1103 · Cited by 620
Heparan Sulfate Proteoglycan Is a Mechanosensor on Endothelial Cells
Florian, J. A., Kosky, J. R., Ainslie, K., Pang, Z., Dull, R. O., & Tarbell, J. M. (2003) · Circulation Research · doi:10.1161/01.res.0000101744.47866.d5 · Cited by 615
Cited by
Vascular Endothelial Cell Biology: An Update
Krüger-Genge, A., Blocki, A., Franke, R.-P., & Jung, F. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20184411 · Cited by 1,163
The glycocalyx: a novel diagnostic and therapeutic target in sepsis
Uchimido, R., Schmidt, E. P., & Shapiro, N. I. (2019) · Critical Care · doi:10.1186/s13054-018-2292-6 · Cited by 710
Endothelial Cell Metabolism in Normal and Diseased Vasculature
Eelen, G., de Zeeuw, P., Simons, M., & Carmeliet, P. (2015) · Circulation Research · doi:10.1161/circresaha.116.302855 · Cited by 627
Degradation of the endothelial glycocalyx in clinical settings: searching for the sheddases
Becker, B. F., Jacob, M., Leipert, S., Salmon, A. H. J., & Chappell, D. (2015) · British Journal of Clinical Pharmacology · doi:10.1111/bcp.12629 · Cited by 464
Role of Endothelial Cell Metabolism in Vessel Sprouting
De Bock, K., Georgiadou, M., & Carmeliet, P. (2013) · Cell Metabolism · doi:10.1016/j.cmet.2013.08.001 · Cited by 423
The cell biology of renal filtration
Scott, R. P., & Quaggin, S. E. (2015) · Journal of Cell Biology · doi:10.1083/jcb.201410017 · Cited by 372
Chappell, D., Bruegger, D., Potzel, J., Jacob, M., Brettner, F., Vogeser, M., Conzen, P., Becker, B. F., & Rehm, M. (2014) · Critical Care · doi:10.1186/s13054-014-0538-5 · Cited by 336
Derangement of the endothelial glycocalyx in sepsis
Iba, T., & Levy, J. H. (2019) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.14371 · Cited by 322
Enkavi, G., Javanainen, M., Kulig, W., Róg, T., & Vattulainen, I. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00538 · Cited by 289
Intrinsically disordered proteins drive membrane curvature
Busch, D. J., Houser, J. R., Hayden, C. C., Sherman, M. B., Lafer, E. M., & Stachowiak, J. C. (2015) · Nature Communications · doi:10.1038/ncomms8875 · Cited by 278
Modulation of Endothelial Glycocalyx Structure under Inflammatory Conditions
Kolářová, H., Ambrůzová, B., Švihálková Šindlerová, L., Klinke, A., & Kubala, L. (2014) · Mediators of Inflammation · doi:10.1155/2014/694312 · Cited by 257
Aldecoa, C., Llau, J. V., Nuvials, X., & Artigas, A. (2020) · Annals of Intensive Care · doi:10.1186/s13613-020-00697-1 · Cited by 253
Nanomedicines for renal disease: current status and future applications
Kamaly, N., He, J. C., Ausiello, D. A., & Farokhzad, O. C. (2016) · Nature Reviews Nephrology · doi:10.1038/nrneph.2016.156 · Cited by 250
Mind the gap: mechanisms regulating the endothelial barrier
Radeva, M. Y., & Waschke, J. (2018) · Acta Physiologica · doi:10.1111/apha.12860 · Cited by 249
“Therefore, it is likely that both synthesis and degradation of ESG can modulate the rate of molecule penetration.(70) Another factor regulating endothelial barrier stability is laminar shear stress sensed by the ESG.”
BackgroundDamage of the endothelial glycocalyx in chronic kidney disease
Padberg, J.-S., Wiesinger, A., di Marco, G. S., Reuter, S., Grabner, A., Kentrup, D., Lukasz, A., Oberleithner, H., Pavenstädt, H., Brand, M., et al. (2014) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2014.03.016 · Cited by 241
“In the past two decades, however, intravital microscopy studies revealed that the eGC represents a substantial intravascular compartment contributing significantly to vascular wall homeostasis [9,33].”
BackgroundXu, C., Chang, A., Hack, B. K., Eadon, M. T., Alper, S. L., & Cunningham, P. N. (2014) · Kidney International · doi:10.1038/ki.2013.286 · Cited by 207
Ando, Y., Okada, H., Takemura, G., Suzuki, K., Takada, C., Tomita, H., Zaikokuji, R., Hotta, Y., Miyazaki, N., Yano, H., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-35976-2 · Cited by 189
The Adaptive Remodeling of Endothelial Glycocalyx in Response to Fluid Shear Stress
Zeng, Y., & Tarbell, J. M. (2014) · PLoS ONE · doi:10.1371/journal.pone.0086249 · Cited by 188
“The adaptation of the glycocalyx to fluid shear stress involves a balance between the synthesis of glycocalyx components including both GAGs and core proteins, and their degradation that is modulated by enzymes such as heparinase and metalloproteases [4,6].”
BackgroundMechanosensing at the Vascular Interface
Tarbell, J. M., Simon, S. I., & Curry, F.-R. E. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071813-104908 · Cited by 180
“Curry FE, Adamson RH. Sphingosine-1-phosphate and the “albumin effect” on rat venular microvessels.”
BackgroundMethodInfluentialSelf-citationNanomechanics of the Endothelial Glycocalyx in Experimental Sepsis
Wiesinger, A., Peters, W., Chappell, D., Kentrup, D., Reuter, S., Pavenstädt, H., Oberleithner, H., & Kümpers, P. (2013) · PLoS ONE · doi:10.1371/journal.pone.0080905 · Cited by 170
“From a technical perspective it is possible that our AFM approach can detect thickness and stiffness only in more dense glycocalyx-layers close to the plasma membrane [7,39], thereby underestimating (cell type specific) heterogeneity of the looser outer regions of the eGC.”
BackgroundShear Stress and Atherosclerosis
Heo, K.-S., Fujiwara, K., & Abe, J.-I. (2014) · Molecules and Cells · doi:10.14348/molcells.2014.0078 · Cited by 169
“, 2013), glycocalyx (Curry and Adamson, 2012), intermediate filaments (Helmke et al.”
BackgroundDaiber, A., & Chlopicki, S. (2020) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2020.02.026 · Cited by 166
“endothelium [199], whereas, reciprocally, biglycan, a constituent of the glycocalyx of capillaries, inhibited platelet activation and, finally,”
BackgroundCardiovascular manifestations of the emerging dengue pandemic
Yacoub, S., Wertheim, H., Simmons, C. P., Screaton, G., & Wills, B. (2014) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2014.40 · Cited by 163
Perturbation of the microvascular glycocalyx and perfusion in infants after cardiopulmonary bypass
Nussbaum, C., Haberer, A., Tiefenthaller, A., Januszewska, K., Chappell, D., Brettner, F., Mayer, P., Dalla Pozza, R., & Genzel-Boroviczény, O. (2015) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2015.08.050 · Cited by 41
Metadata
- Authors
- Curry, F. E., & Adamson, R. H.
- Venue
- Annals of Biomedical Engineering
- Published
- 2011-10-19
- Volume
- 40
- Issue
- 4
- Pages
- 828-839
- ISSN
- 0090-6964 (ISSN-L)
- 1573-9686
- OpenAlex
- W2086946136
- Cited by
- 312
- References
- 81
- FWCI
- 5.50
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.