CoChat

Accuracy and Reproducibility of Patient-Specific Hemodynamic Models of Stented Intracranial Aneurysms: Report on the Virtual Intracranial Stenting Challenge 2011

Cito, S., Geers, A. J., Arroyo, M. P., Palero, V. R., Pallarés, J., Vernet, A., Blasco, J., San Román, L., Fu, W., Qiao, A., Janiga, G., Miura, Y., Ohta, M., Mendina, M., Usera, G., Frangi, A. F. · 2015 · Annals of Biomedical Engineering

The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.

Abstract

Validation studies are prerequisites for computational fluid dynamics (CFD) simulations to be accepted as part of clinical decision-making. This paper reports on the 2011 edition of the Virtual Intracranial Stenting Challenge. The challenge aimed to assess the reproducibility with which research groups can simulate the velocity field in an intracranial aneurysm, both untreated and treated with five different configurations of high-porosity stents. Particle imaging velocimetry (PIV) measurements were obtained to validate the untreated velocity field. Six participants, totaling three CFD solvers, were provided with surface meshes of the vascular geometry and the deployed stent geometries, and flow rate boundary conditions for all inlets and outlets. As output, they were invited to submit an abstract to the 8th International Interdisciplinary Cerebrovascular Symposium 2011 (ICS'11), outlining their methods and giving their interpretation of the performance of each stent configuration. After the challenge, all CFD solutions were collected and analyzed. To quantitatively analyze the data, we calculated the root-mean-square error (RMSE) over uniformly distributed nodes on a plane slicing the main flow jet along its axis and normalized it with the maximum velocity on the slice of the untreated case (NRMSE). Good agreement was found between CFD and PIV with a NRMSE of 7.28%. Excellent agreement was found between CFD solutions, both untreated and treated. The maximum difference between any two groups (along a line perpendicular to the main flow jet) was 4.0 mm/s, i.e. 4.1% of the maximum velocity of the untreated case, and the average NRMSE was 0.47% (range 0.28-1.03%). In conclusion, given geometry and flow rates, research groups can accurately simulate the velocity field inside an intracranial aneurysm-as assessed by comparison with in vitro measurements-and find excellent agreement on the hemodynamic effect of different stent configurations.

Overview

Integrity signals

Registry

Crossref · 10.1007/s10439-014-1082-9

Cites

45 of 45 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 1

  1. Cito, S., A. J. Geers, M. P. Arroyo, J. Pallares, A. Vernet, V. R. Palero, J. Lobera, J. Blasco, L. San-Roman, and A. F. Frangi. Virtual Intracranial Stenting Challenge 2011. 8th International Interdisciplinary Cerebrovascular Symposium, Shanghai, China, 2011.

Cited by

See all 20

Metadata

Authors
Cito, S., Geers, A. J., Arroyo, M. P., Palero, V. R., Pallarés, J., Vernet, A., Blasco, J., San Román, L., Fu, W., Qiao, A., Janiga, G., Miura, Y., Ohta, M., Mendina, M., Usera, G., & Frangi, A. F.
Affiliations
  • University of Helsinki (FI)
  • Universitat Pompeu Fabra (ES)
  • Universidad de Zaragoza (ES)
  • Universitat Rovira i Virgili (ES)
  • Hospital Clínic de Barcelona (ES)
  • Beijing Union University (CN)
  • Beijing University of Technology (CN)
  • Otto-von-Guericke-Universität Magdeburg (DE)
  • Tohoku University (JP)
  • Universidad de la República de Uruguay (UY)
Corresponding author
  • Cito, S.
  • Geers, A. J.
Venue
Annals of Biomedical Engineering
Published
2014-08-13
Volume
43
Issue
1
Pages
154-167
ISSN
  • 0090-6964 (ISSN-L)
  • 1573-9686
OpenAlex
W2076604969
Cited by
20
References
45
Citations by year
2026: 1 · 2024: 1 · 2023: 1 · 2021: 2 · 2020: 1 · 2019: 3 · 2018: 3 · 2017: 2 · 2016: 3 · 2015: 3
FWCI
1.74
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Annals of Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
  • Research Explorer (The University of Manchester) (submittedVersion)
Topics
  • Health Sciences › Medicine › Clinical Neurology › Intracranial Aneurysms: Treatment and Complications
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cerebrovascular and Carotid Artery Diseases
  • Health Sciences › Medicine › Surgery › Aortic aneurysm repair treatments
Keywords
intracranial aneurysm, intracranial stenting, hemodynamics, computational fluid dynamics, reproducibility
MeSH terms
Intracranial Aneurysm, Cerebrovascular Circulation, Computer Simulation, Hemodynamics, Humans, Reproducibility of Results, Stents, Hydrodynamics, Patient-Specific Modeling

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.