The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
A New Method for Measuring Meal Intake in Humans via Automated Wrist Motion Tracking
Open accessAbstract
Measuring the energy intake (kcal) of a person in day-to-day life is difficult. The best laboratory tool achieves 95 % accuracy on average, while tools used in daily living typically achieve 60–80 % accuracy. This paper describes a new method for measuring intake via automated tracking of wrist motion. Our method uses a watch-like device with a micro-electro-mechanical gyroscope to detect and record when an individual has taken a bite of food. Two tests of the accuracy of our device in counting bites found that our method has 94 % sensitivity in a controlled meal setting and 86 % sensitivity in an uncontrolled meal setting, with one false positive per every 5 bites in both settings. Preliminary data from daily living indicates that bites measured by the device are positively related to caloric intake illustrating the potential of the device to monitor energy intake. Future research should seek to further explore the relationship between bites taken and kilocalories consumed to validate the device as an automated measure of energy intake.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prevalence and Trends in Obesity Among US Adults, 1999-2008
Flegal, K. M. (2010) · JAMA · doi:10.1001/jama.2009.2014 · Cited by 7,580
Long-term weight loss maintenance
Wing, R. R., & Phelan, S. (2005) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/82.1.222s · Cited by 1,941 · cited 1×
“Studies of individuals who have lost significant amounts of weight and maintained that weight loss indicate that a common behavior is self-monitoring of intake (Wing and Hill 2001; Wing and Phelan 2005).”
Self-monitoring in weight loss: a systematic review of the literature
Burke, L. E., Wang, J., & Sevick, M. A. (2011) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2010.10.008 · Cited by 1,203 · cited 1×
“A recent meta-review found that in all 15 studies reviewed, there was a significant relationship between self-monitoring dietary intake and weight loss (Burke et al. 2011).”
Physical Activity Assessment With Accelerometers: An Evaluation Against Doubly Labeled Water
Plasqui, G., & Westerterp, K. R. (2007) · Obesity · doi:10.1038/oby.2007.281 · Cited by 654
Measurement of energy expenditure
Levine, J. A. (2005) · Public Health Nutrition · doi:10.1079/phn2005800 · Cited by 401 · cited 1×
“energy change due to weight gain/loss) was shown to be 2–8 % error per day (Schoeller 1988).”
The Use of Mobile Devices in Aiding Dietary Assessment and Evaluation
Zhu, F., Bosch, M., Woo, I., Kim, S., Boushey, C. J., Ebert, D. S., & Delp, E. J. (2010) · IEEE Journal of Selected Topics in Signal Processing · doi:10.1109/jstsp.2010.2051471 · Cited by 355
Need for Technological Innovation in Dietary Assessment
Thompson, F. E., Subar, A. F., Loria, C. M., Reedy, J. L., & Baranowski, T. (2010) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2009.10.008 · Cited by 349
Black, A., & Cole, T. (2000) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1600970 · Cited by 247 · cited 1×
“A meta-analysis (Black and Cole 2000) of 25 studies using DLW in free living conditions found an 8–15 % range for repeatability of energy intake measurements.”
Use of technology in children’s dietary assessment
Boushey, C. J., Kerr, D. A., Wright, J., Lutes, K. D., Ebert, D. S., & Delp, E. J. (2009) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2008.65 · Cited by 231
Accuracy of a PDA-based dietary assessment program
Beasley, J., Riley, W. T., & Jean-Mary, J. (2005) · Nutrition · doi:10.1016/j.nut.2004.11.006 · Cited by 124
Cited by
Energy balance measurement: when something is not better than nothing
Dhurandhar, N. V., Schoeller, D., Brown, A. W., Heymsfield, S. B., Thomas, D., Sørensen, T. I. A., Speakman, J. R., Jeansonne, M., Allison, D. B., & the Energy Balance Measurement Working Group (2015) · International Journal of Obesity · doi:10.1038/ijo.2014.199 · Cited by 567
De Toro-Martín, J., Arsenault, B., Després, J.-P., & Vohl, M.-C. (2017) · Nutrients · doi:10.3390/nu9080913 · Cited by 492
Nutritional Risk Screening and Assessment
Reber, E., Gomes, F., Vasiloglou, M. F., Schuetz, P., & Stanga, Z. (2019) · Journal of Clinical Medicine · doi:10.3390/jcm8071065 · Cited by 485
RisQ: recognizing smoking gestures with inertial sensors on a wristband
Parate, A., Chiu, M.-C., Chadowitz, C., Ganesan, D., & Kalogerakis, E. (2014) · Proceedings of the 12th annual international conference on Mobile systems, applications, and services · doi:10.1145/2594368.2594379 · Cited by 282
Self-report-based estimates of energy intake offer an inadequate basis for scientific conclusions
Schoeller, D. A., Thomas, D., Archer, E., Heymsfield, S. B., Blair, S. N., Goran, M. I., Hill, J. O., Atkinson, R. L., Corkey, B. E., Foreyt, J., et al. (2013) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.113.062125 · Cited by 177
Metadata
- Authors
- Dong, Y., Hoover, A., Scisco, J., & Muth, E.
- Venue
- Applied Psychophysiology and Biofeedback
- Published
- 2012-04-10
- Volume
- 37
- Issue
- 3
- Pages
- 205-215
- ISSN
- 0363-3586 (ISSN-L)
- 1090-0586
- 1573-3270
- OpenAlex
- W2095344888
- Cited by
- 231
- References
- 11
- FWCI
- 11.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A New Method for Measuring Meal Intake in Humans via Automated Wrist Motion Tracking. https://app.cochat.ai/papers/10.1007/s10484-012-9194-1
- The paper
- Dong, Y., Hoover, A., Scisco, J., & Muth, E. (2012). A New Method for Measuring Meal Intake in Humans via Automated Wrist Motion Tracking. Applied Psychophysiology and Biofeedback. https://doi.org/10.1007/s10484-012-9194-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.